Professional Documents
Culture Documents
Heat Exchanger E-101 (Energy Balance)
Heat Exchanger E-101 (Energy Balance)
1) E-101
Inlet Stream
Stream 7 31
Ethanol 0 0.00E+00 -
Outlet Stream
Stream 8 18
Ethanol 0 - 0 0.00E+00
ethane 7.889E-07 1.04E-01 2.85E-06 8.12E-02
water 2.395E-01 3.82E-02 1.538E-03 3.56E-02
Total Cp 6.18E-02 3.01E-02
Energy, Q (kJ/s) 1.76E+02 1.59E+02
Total Energy, Q
(MW)
Qtotal = Qout- Qin
=
2) E-102
Inlet Stream
Stream 8 6
Outlet Stream
Stream 9 17
Total Energy, Q
(MW)
=(
3) E-103
Inlet Stream
Stream 9
Composition Cp (kJ/mol.°C)
Carbon monoxide 2.96E-02
hydrogen 2.89E-02
methane 4.18E-02
methanol 5.46E-02
carbon dioxide 3.56E-02
Ethanol 0.00E+00
ethane 6.73E-02
water 3.45E-02
Total Cp 2.92E-01
Energy, Q (kJ/s) 8.70E+04
Total Energy, Q (MW) 8.70E+04
Outlet Stream
Stream 10
Temperature (°C) 35
Composition Cp (kJ/mol.°C)
Carbon monoxide 2.91E-02
hydrogen 2.88E-02
methane 3.62E-02
methanol 4.59E-02
carbon dioxide 3.61E-02
Ethanol 0.00E+00
ethane 5.42E-02
water 3.37E-02
Total Cp 2.64E-01
Energy, Q (kJ/s) 2.01E+04
Total Energy, Q (MW) 2.01E+04
Qtotal = Qout-Qin
= (2.01E+04) – (8.70E+04)
= -6.69E+04