INSTRUCTION
Solving alarm 2G Nokia "RSSI detected Rx signal difference exceeding Issued Date: 25/01/2017
threshold" Page: 1-6
Signature
TABLE OF CONTENTS
Table of Contents
1. PURPOSE .................................................................................................................................................. 3
2. SCOPE OF APPLICATION ...................................................................................................................... 3
3. REFERENCE DOCUMENTS ................................................................................................................... 3
4. CONTENT ................................................................................................................................................. 3
4.1 Introduce about the RSSI alarm ............................................................................................................... 3
4.1.1 What is the RSSI alarm ..................................................................................................................... 3
4.1.2 Detect RF module and corresponding port having problem ............................................................. 4
4.1.3 Analysis............................................................................................................................................. 5
4.2 Troubleshooting the alarm .................................................................................................................. 6
4.2.1 Detect the Port in RF Module having problem by Analysis step of 4.1.3 ................................... 6
4.2.2 Check if there is a power combining on the sector: ..................................................................... 6
4.2.3 Request NOC to send technician on site implement:................................................................... 6
1. PURPOSE
Instruct how to troubleshot and correct Alarm “RSSI detected Rx signal difference exceeding
threshold”, it should be used during monitoring of BTS Alarm.
2. SCOPE OF APPLICATION
This instruction is applied to engineers of BSS in Technical Department, NOC, Branch and all the
engineers of Viettel Cameroon in charge of RAN in Nokia Area.
3. REFERENCE DOCUMENTS
NED library – Nokia document.
4. CONTENT
The RSSI Alarm can be due to:
- Mismatch of power combining (between Software Configuration and Hardware Connections on site).
- Issue of Jumper and Connections between RF module and Antenna.
When the different between Rx level of main and diversity is exceeding 10dB, this alarm will appear.
Eg. Rx main =-85dBm, Rx Div = -110dBm)
Schema 2: Example Design Power Combining AD0067B (S1 on port 01&03; S2 on port 01&03)
4.1.3 Analysis
The case normal configuration:
In this case BTS 242 connect to port 3&4 of RF module including TRx 5,6,7,8,15,18.
The main Rxlevel is good (-89dBm) in Port 3.
The Div Rxlevel is bad (-120dBm) in port 4.
Conclusion: Port 4 have problem make Diversity receive signal is bad
4.2.2.1 Check if the Soft configuration don’t respect the Design as the corresponding CR correct it
4.2.2.2 If Soft configuration follow the design: Call region to check the connection on site and correct as in the design.
4.2.2.3 Check if alarm is clear If Alarm still not clear, move to 4.2.3
Notice: BSS need to be sure all the port in RF Module is all connect exactly as the design of Radio
Department.
4.2.3.2 Re-connect jumpers to corresponding port having bad Rxlevel, connect it correctly and tightly. Then
4.2.3.3 If the alarm still not clear, change jumper and repeat step 4.2.3.2.
4.2.3.4 If still not clear, change RF module and repeat step 4.2.3.3.