You are on page 1of 3
The BIDDER shall ensure the following documentation are prepared and submitted to 4.15 Final Documents: BIDDER shall submit the three copies of operation and maintenance manuals at the time of commissioning in addition to one copy two weeks before despatch. The manual shall be in sufficient detail with step by step instructions to enable others to inspect erect, commission, maintain, dismantle, repair, reassemble and adjust all parts of the equipment. Each manual shall also include a complete set of approved as built drawings together with performance / rating curves / charts of the equipment, maintenance schedule and test certificates wherever applicable. The BIDDER shall submit Quality assurance documentation specific for the project. 10.3. STP-ELECTRICAL REQUIREMENTS, SCOPE AND BRIEF DESCRIPTION OF WORK The scope of Contractor shall include Supply, Installation, Testing and Commissioning of all Electrical systems and equipment required for the STP. The major equipment/system covered under scope of work shall be as follows: 415 V Switchgear LT power & control and instrumentation cables and cable trays, trenches, cable racks with necessary fire barriers, fire proof sealing and coating systems, Supporting structures, cable laying & Termination and all other cable accessories. Control Panel Drive motors (LT) for all rotating mechanical equipment. Allumination system with Distribution Boards, light fixtures etc. Jarthing and lightning protection. Civil works for electrical equipment such as foundation, trenches, ete. Essential spares and special tools and tackles required for installat maintenance of electrical equipment. operation and 10.4, DETAILED SCOPE OF WORK - ELECTRICAL Power Supply Scheme The Purchaser shall provide 3Phase, 4wire, 415V, 50Hz Power Supply as single point supply. All further work will be in package vendor’s scope. LV Switchgear 415 V, 3 phase, 4 wire LV MCC shall feed all LV loads such as pump and other auxiliary loads. The MCC shall have incomer and required number of outgoing feeders. The MCC shall be sheet metal enclosed compartmentalized, fixed type. The panel shall have IPS2 rating with from 3b separation as per IEC. Fault level of offered MCC shall be 50 kA for Isec. Motors Induction motors for the pumps shall be rated for 415 V, 3 phase, 50 Hz. All the motors shall be suitable for supply variation conditions of +/- 10% voltage, +/- 5% frequency and 10% combined voltage and frequency. All offered motors shall have IE3 (or better) efficiency. Motors shall be minimum IPSS rated. For outdoor applications suitable Canopy shall be provided. Offered Motor shall be suitable for its application with Pump / VED ete. Selection of suitable Motor is package Vendor’s responsibility. Cables LV cables shall be of 1100V grade, Copper / Aluminum conductor, XLPE insulated, PVC inner sheath, armoured/unarmoured and FRLS PVC outer sheath, All power cables shall be 809 sized based on continuous current capacity, short-circuit rating and voltage drops. The suitable derating factors to account for grouping of cables, depth of lying, etc. shall be considered. Cables up to and including 16sq.mnm shall be of Copper conductor and 25 sq.mm, and above shall be of Aluminum conductor. The minimum size for Control cable shall be 1.5 sq.m, Lighting All indoor and outdoor areas shall be provided with AC lighting (Areas under package Vendor's scope) The lighting system shall comprise of fixtures for pump houses, indoor rooms and street light fixture along with associated Distribution Board. (DB). All fixtures shall be LED type only. The wiring of lighting circuit shall be done by wires in GI conduit for indoor areas and by armoured cables in outdoor areas. The illumination levels for various areas shall be as per IS. Earthing And Lightning Earthing system shall be designed on the basis of IS 3043 code of practice for safety earthing. The material of earthing conductors above ground shall be galvanised steel to prevent atmospheric corrosion and shall be of mild steel when buried in the ground or embedded in concrete. The earthing conductor shall be sized considering system fault level, corrosion factor and fault clearing time. Lightning protection shall be provided for buildings/structures covered under this package as applicable as per relevant IS /TEC standards. Civil Buildings / Civil Works All civil works for electrical equipment, ie. foundations, rooms, buildings, etc., covered under this package shall be carried out by the Contractor. Switchgear room shall be properly ventilated. The layout of this building shall consider operation / maintenance space as per TE rules. The dimension of building shall be subject to Purchaser's approval. 10.3.3 ELECTRICAL SYSTEM DESIGN a) General Standards The design, manufacture, assembly and testing as well as performance of the equipment shall conform to the relevant IS specifications (atest revision). In ease the Contractor is not in a position to comply fully with certain IS specifications, or in respect of certain items for which there are no IS specifications, the Contractor may base his proposals on IEC recommendations or other reputed national or international standards subject to the approval of the purchaser. All equipment supplied and all work done including system design and detailed engineering shall also comply with the statutory requirements of CEA rules / regulations. b)Climatie Conditions The climatic conditions generally prevailing at site have already been described in main volume. Electrical equipment selection and derating shall generally be based on ambient temperature of 50 deg. c. For specific hot areas the ambient temperature conditions shall be taken into consideration and equipment suitably derated where necessary. In hot areas of higher temperature conditions, the equipment shall be adequately protected against damage from radiant heat and hot air. ©) Make and Interchangeability The make of major equipment shall be limited to preferred makes indicated under chapter ‘List of preferred makes’. If the Bidder prefers to supply other than from the Preferred Makes list, it should be with the approval of the Purchaser. ‘Makes of all other equipment and accessories are subject to prior approval by the purchaser. Similar equipment and components shall be of same make, equipments of same type and rating shall be interchangeable. The purchaser has the option of instruments and controls and any other specialized items in the the Contractor shall have to supply equipment of the particular make, iffso required. 810 5.1 DESIGN CRITERIA Standard voltage levels The standardised voltage levels as given in the Table below shall be adopted: Sr.No. | Description Voltage level 1. Incoming supply 415 V, 3 phase, 4 win effectively earthed. S0Hz, Permissible variations: The system unit/plant equipment shall be designed suitable for variation in voltage and frequency as indicated in the table below: Sr. Description Voltage Frequency No 1. | Permissible variation with rated | +/- 10% 41-3 Hz performance/rated current 2. Permissible voltage dip at LT | -15% - switchgear bus for starting of largest LT motor Criteria for starting of motors: Motors upto and including 7.5 kW shall be with DOL start. ‘Motors rated 9.3 and above shall be star / delta (or other suitable method) started, sil

You might also like