Professional Documents
Culture Documents
Ficha - Control - Temperatura Equipel PDF
Ficha - Control - Temperatura Equipel PDF
Foreword:
In response to the demands from the emerging market, Delta temperature controller R&D
team will launch the competitive Delta DTD series temperature controller in the second season
of 2007. DTD series temperature controller offers relay and voltage pulse output and saves a
group of alarm output with multiple modes. For controls on other physical quantity, DTD series
are equipped with analog input function. Delta DTD series temperature controller will be very
competitive in the market.
Table of Content:
Foreword, table of content………………………………………………… 1
Appearance …………………………………………………………… 2
Features …………………………………………………………… 3
Electrical specifications……………………………………………………… 4
DTA/DTB/DTD comparison table …………………………………… 5
Ordering information………………………………………………………… 6
Launch schedule………..………………………………………………… 6
Dimension …………………………………………………………… 6
w w w . d e l t a w w . c o m 1
Newsletter
New Product Release
Product Introduction
DTD
w w w . d e l t a w w . c o m 2
Newsletter
New Product Release
Features:
1. Two panel sizes: 48mm*48mm (1/16 DIN), 48mm*96mm (1/8 DIN), meets the demand
from the market.
2. Offering PID, ON/OFF, manual and PID programmable control, for multiple
applications.
3. Built in with various kinds of sensors, for flexible switching.
4. A group of alarm output with 8 modes, for more choices of applications.
5. The set value is stored in EEPROM (4K bits) and can be written repeatedly for 1
million times and stored for 10 years. The data are more stable.
6. The key locked function makes the controller safer than other controllers.
7. Waterproof panel (IP66)
Terminal definition
DTD 4848
w w w . d e l t a w w . c o m 3
Newsletter
New Product Release
Electrical Specifications:
Input power AC 100 ~240V (-15% ~ +10%), 50/60Hz
Voltage range Normal rated voltage 85% ~ 110%
Power consumption 5VA typical
Display method 7-segment LED display
present value: red , set value: green
Input sensor Thermocouple: K, J, T, E, N, R, S, B, L, U, Txk
Platinum RTD: JPt100, Pt100
Linear analog input: 0 ~ 5V, 0 ~ 10V, 0 ~ 20mA, 4 ~ 20mA, 0 ~ 50mV
Control method PID, ON/OFF, manual, 1 x 8 procedure
Control output type Relay: SPST, Max. 250V, 5A
Voltage pulse output: DC14V, Max. load current 40mA
Alarm output Relay output : SPST, 250V, 3A
Display accuracy 1 digit after decimal point, or no decimal point
Sampling frequency 0.4 second
Vibration resistance 10 ~ 55Hz 10m/s2 each in X, Y and Z directions 10 min
2
Shock resistance Max. 300m/ s 3 times in each of the 3 axes, 6 directions
Operation
0°C ~ +50°C
temperature
Storage
-20°C ~ +65°C
temperature
Operation Altitude 2,000m or less
Operation humidity 35% ~ 85% RH (non-condensing)
w w w . d e l t a w w . c o m 4
Newsletter
New Product Release
w w w . d e l t a w w . c o m 5
Newsletter
New Product Release
Ordering information:
DTD □ □ □ □ □
Œ • Ž
Dimension:
w w w . d e l t a w w . c o m 6