Professional Documents
Culture Documents
Frequency range:400~11000MHz
Sainty-Tech Communications Limited
Features To Order :
● Center Frequency: 400MHz~11000MHz 5 FS 10 – 6575 / T 750 –O / O
● Typical 0.05dB Chebyshev response 12 3 4 5 6 7 8
● Sections 2~15 or more
● 3dB bandwidth: 1%~30% or more 1. Section Number
● Max VSWR 1.2:1 (typ1.5:1)。 2. Series Code(FS——“Combline”)
● Specific requirements on IL, power available 3. Package Code——type10
● Optimized structures for custom requirement 4. Center Frequency(6575MHz)
● 3FC parasitic passband (4Fc or more) 5. Designator of Bandwidth
6. Bandwidth(750MHz)
7. Input Connector (see Page29)
8. Output Connector (see Page29)
♦Specification
BW/Fc× Power Operating
Series Freq(MHz) VSWR Impedance Sections
100% Handling Temperature1)
Notes:* General power handling is 5W, optimized design can reach 300W or better.
1) Special requirement on operating temperature -55~+85℃ available
28
Comline Cavity Filter
Sainty-Tech Communications Limited
♦Stopband Attenuation
•The right curve gives the stopband ♦Insertion Loss
attenuation for STC' s combline cavity filter. One of the characters of combline cavity filter is to
This curve shows the attenuation as multiples realize both narrow band and wide band design
of the 3dB bandwidth for FS series cavity
filter.The following formula is used in with low insertion loss.
calculating the stopband attenuation: •Typical Insertion Loss < 1.5dB
3dB Bw from Fc=
Fs − Fc •Broader passband lower IL
3dB BW •IL increase with the number of sections
Example: •1 section increase result 0.1dB IL increase
Center Frequency Fc=2600 MHz 10
3dB BW=200 MHz
20
Number of sections N=5
ATTENUATION(dB)
The attenuation at f1=2400 MHz: 30 2 2
2400 − 2600
R= = −1
200 40
The curve indicate attenuation is 30dB。
50 3 3
actual one -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
♦Environmental Standard Special NUMBER OF 3dB BANDWIDTH
Vibration(5~2000Hz) 10G 20G
Shock(11 mSec) 10G 25G ♦Mechanical Features
Relative Humidity 0~90% 95% • Blind screw thread on the bottom it
Storage Temp -40~+100℃ -55~+125℃ can be determined by customers
• Width and Height shown in the
down left table
• Dimension:
L=(K)(N)+10(mm)
K=6~16 (TBD)
Example:
2.5GHz, N = 6, BW3dB= 1%
K=12
L=12×6+10 = 82 (mm)
W=40mm
H=18mm
♦Dimension ★Connectors
GHz
Freq 0.4-1 1-2 2-3 3-4 4-5 5-6 6-8 8-11 Code O OP P L N
mm
W 125 70 40 30 25 22 20 17
Connectors SMA(F) SMA(M) microstrip L16(F) N(F)
H mm 25 20 18 17 16 15 14 13
Features To order
● Frequency Range 600MHz~18000MHz 5 FD 10 – 8240 / T1200 –O / O
● Typical 0.05dB Chebyshev response 1 2 3 4 5 6 7 8
● Sections 2~11 or more
● %3dB Bandwidth 0.8%~80% or wider 1. Number of sections
● Maximum VSWR 1.3:1 (Typ 1.5:1)。 2. Series(FD——Interdigital)
● Specific requirements on IL, power available 3. Package Code——10
● Optimized structures for custom requirement 4. Center Frequency(8240MHz)
● 2×FC parasitic passband (2.5Fc or more) 5. Bandwidth Designator(same as LC
filter)
6. Bandwidth(1200MHz)
7. Input Connector (see Page 31)
8. Output Connector (see Page 31)
♦Specification
Power Operating
Series Freq(MHz) BW/Fc×100% VSWR Impedance sections
Handling Temp1)
Note:* General power handling is 5W, optimized design can reach 300W or better.
1) Special requirement on operating temperature -55~+85℃ available
30
Interdigital Cavity Filter
Sainty-Tech Communications Limited
ATTENUATION(dB)
3dB BW=500 MHz
Number of sections N=5 30
The attenuation at f1=6100 MHz:
2 2
6100 − 5600 40
R= = +1
500 3 3
The curve indicate attenuation is 30dB
50
•Following formula used to calculate the stopband 4 4
60
attenuation approximately 5 5
L
dB
= 20×N×log10(2×|R|)
6
6
70
This result may be 5~10dB worse than the
-4 -3 -2 -1 0 +1 +2 +3 +4
NUMBER OF 3dB BANDWIDTH
actual one
♦Environmental Standard Special
Vibration (5~2000Hz) 10G 20G
Shock (11 mSec) 10G 25G ♦Mechanical Features
Relative Humidity 0~90% 95% • Blind screw thread hole on the bottom
which can be determined by customers
Storage Temp -40~+100℃ -55~+125℃
• Width and height shown in the down left
table
• Dimension:
L=(K)(N)+10(mm)
K=6~14(TBD)
Example:
2.5GHz,6 sectoins, BW3dB = 3%,
K=10
L=10×6+10 = 70 (mm)
W=45mm
H=15mm
♦Dimension ★Connectors
FreqGHz 0.6-1 1-2 2-3 3-4 4-6 6-8 8-10 10-18 Code O OP P L N
mm
W 130 80 45 35 28 22 19 16
H mm
24 16 15 14 13 12 11 Connectors SMA(F) SMA(M) microstrip L16(F) N(F)
31
Coaxial Cavity Filter
Cavity Filter Frequency range:400~6000MHz
Sainty-Tech Communications Limited
Features To Order
• Center Frequency range 400MHz-6000MHz 5 CC 20 – 4575 / T 760 –O / O
• Typical 0.05dB Chebyshev response 12 3 4 5 6 7 8
• Sections 2 to 10 or more
• % 3dB bandwidth 0.6%-5% or wider 1. Number of sections
• Maximum VSWR 1.2:1 (Typ 1.3:1) 2. Series(CC——“Coaxial”)
• Specific requirements on IL, power handling 3. Package Code ——2
available 4. Center Frequency(4575MHz)
• Optimized structures for custom requirement 5. Bandwidth Designator(same as LC filter)
• 2.5FC parasitic passband (4Fc or more) 6. Bandwidth(760MHz)
7. Input connector (see Page33)
8. Output connector (see Page33)
♦Specification
MHz
Power Opreating
Series Freq BW/Fc×100% VSWR Impedance Sections
Handling Temp1)
Note:* General power handling is 5W; optimized design can reach 300W or better
1) Special requirement on operating temperature -55~+85℃ available
ATTENUATION(dB)
N=5 the attenuation at 1796MHz is:
1796 − 1832
R= = −2 , 30
18 2
The curve indicate the attenuation is 62dB。 2
40
• Following formula used to calculate the stopband
attenuation approximately 3 3
50
L(dB)=20×N×log10(2×|R|)
4 4
The result may be 4~9dB worse than the actual 60
5 5
Then the result of previous example is 60.2dB 6 6
70
-4 -3 -2 -1 0 +1 +2 +3 +4
♦Environmental Standard Special NUMBER OF 3dB BANDWIDTH
Vibration(5~2000Hz) 10G 20G
♦Machanical Features
Shock(11 mSec) 10G 25G •Blind screw thread hole on the
bottom, which can be determined by
Relative Humidity 0~90% 95% customer
Storage Temp -40~+100℃ -55~+125℃ •Dimension shown in the down left
table, custom structure available
•Dimension and height:
L=(K+4)×N + 4 (mm)
W=K+8 (mm)
K=12~30 (TBD)
Example:
Fc=900MHz,N=6,BW=2.8%:
K=21
L=25×6+4 = 154 (mm)
H=70 mm
W=29 mm
★Connectors
♦Dimension
FreqGHz 0.6-1 1-2 2-3 3-4 4-5 5-6 Code O OP P L N
H mm
70 40 30 25 21 19 Connectors SMA(F) SMA(M) Microstri L16(F) N(F)
33
Rectangular waveguide
Cavity Filter
Cavity Filter Frequency range:5000~18000MHz
Sainty-Tech Communications Limited
Features
To Order
• Center Frequency 5000~18000MHz
5 BJ 20 – 6000 / T 50 –O / O
• Typical TE101 design
12 3 4 5 6 7 8
• Section 2 to 10 or more
• %3dB BW: 0.3~4% or wider
1. Number of sections
• Maximum VSWR 1.2:1 (Typ1.3:1)。
2. Series(BJ—rectangular waveguide)
• Specific requirements on insertion loss, power
3. Package Code — 20
handling available
4. Center Frequency(6000MHz)
• Optimized structures for custom requirement
5. Bandwidth Designator(same as
• 1.4Fc parasitic passband
LC filter)
6. Bandwidth(50MHz)
7. Input connector
8. Output connector
★Connectors
Code O OP P B N
Connectors SMA(F) SMA(M) microstripp flange N(F)
♦Specification
Power Operating
Series FreqGHz BW/Fc×100% VSWR Impedance Sections
Handling Temp1)
Note:* General power handling is 20W; optimized design can reach better
1) Special requirement on operating temperature -55~+85℃ available
34
Rectangular waveguide Cavity Filter
Sainty-Tech Communications Limited
♦Stopband Attenuation
♦Insertion Loss
•The right curve gives the stopband
With higher “Q” rectangular waveguide cavity filter can
attenuation for STC' s rectangular
waveguide cavity filter. This curve shows the realize more narrower passband than coaxial cavity filter
attenuation as multiples of the 3dB bandwidth with same insertion loss
for BJ series cavity filter.Following formula is IL calculated as:
used to calculating the stopband attenuation: K ( N+0.5)
3dB BW from Fc ( R )=
Fs − Fc IL =
BW(%)
+0.3
3dB BW BW%=BW/Fc×100
Example: K = 0.1
Center Frequency Fc=8000 MHz
3dB BW=30 MHz 10
N=5
The attenuation at 8045 MHz:
20
ATTENUATION(dB)
R = 8045 − 8000 = 1.5 30
30
2
2
The curve indicate the attenuation is 46dB 40
•Following formula used to calculate the 3 3
50
stopband attenuation approximately:
L(dB) = 20×N×log10(2×|R|) 4 4
The result may be 4~9dB worse than
60
5 5
actual 6 6
Then the result of previous example is 70
47.7dB -4 -3 -2 -1 0 +1 +2 +3 +4
NUMBER OF 3dB BANDWIDTH
♦Environmental Standard Special
Vibration(5~2000Hz) 10G 20G
Shock(11 mSec) 10G 25G ♦Machanical Features
Relative Humidity 0~90% 95% •Customer can determine blind screw
thread hole on the bottom
Storage Temp -40~+100℃ -55~+125℃
•Dimension shown in the down left
table, custom structure available
•Dimension and height:
L=(W-4)×N+4 (mm)
H= W/2 + 1 (mm)
Example:
Fc=8000MHz,N=5,BW=0.35%,
W = 33.9 (mm)
L=(33.9-4)×5+4 = 153.9(mm)
H = 17.9 (mm)
♦Specification
FreqGHz 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-18
mm
W 49.5 42.5 37.6 33.9 31 28.7 26.9 25.3 24.0 22.8 20
35
Dielectric Loaded
Cavity Filter
Cavity Filter Frequency range:1500~18000MHz
Sainty-Tech Communications Limited
Features To Order
● Center Frequency 1500MHz~18000MHz 5 HD 10 – 8200 / H50 –O / O
● Typical 0.05dB Chebyshev response 1 2 3 4 5 6 7 8
Quasi-elliptical response and linear 1. Number of sections
phase design available 2. Series
● Sections 2~8 or more 3. Outline code (10—“Parallel”;20—“in line”)
● % 3dB BW: 1‰~6‰(or wider) 4. Center Frequency(8200MHz)
● VSWR 1.2:1 (Typ 1.3:1) 5. Bandwidth designator(same as LC filter)
● Flexiable structure design 6. Bandwidth(50MHz)
● Dielectric temperature compensation 7. Input Connector ( see Page 38)
design perfect temperature stability 8. Output Connector (see Page 38)
● Parasitic passband lower to 1.15×Fc
● Custom outline available
♦Specification
Note:* General power handling is 5W; optimized design can reach 10W
1) Special requirement on operating temperature -55~+85℃ available
3
N=6
The attenuation at f=4250 MHz: 3
40 4
4250 − 4300
R= = −2 . 5 4
20 50
5
The curve indicate the attenuation 64dBc at f
60 5
♦Machanical Features
• Two options,Blind screw thread hole and through 70 6
6
hole, for customer. please contact the factory for the
hole size 80
-5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
•Height shown in the table of dimension
NUMBER OF 3dB BANDWIDTH
• Dimension:
L:
Type 10:L=(K+3.5)×0.5N+(0~4.5)(mm)
Type 20:L=(K+3.5)×N+(0~4.5)(mm) % 3dB Bandwidth 3‰~6‰
W:
10
Type 10:W =K×2+(9~11.5)(mm)
Type 20:W =K+(6~8)(mm)
K=10~39(see table of dimension) 20
Example:(type 10) 2
DEGRESSION(dBc)
Fc=8.15GHz,N=6,BW3dB=5‰,Then 30 2
K=11
L=(11+3.5)×3+2.5=46(mm) 40 3
W=11×2+10=32(mm)
3
H=12(mm) 50 4
60 4 5
5
70 6
6
80
-5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
HD20 Outline Drawing
NUMBER OF 3dB BANDWIDTH
37
Dielectric Loaded Cavity Filter
Sainty-Tech Communications Limited
★Connectors
Code O OP P L N
38
HL Series
Helical Cavity Filter
Helical Cavity Filter Frequency range:30~550MHz
Sainty-Tech Communications Limited
Features To Order
● Frequency Range 30MHz~550MHz 5 HL 10 – 200 / T5.5 –O / O
● Typical 0.05dB Cheybshev response 12 3 4 56 7 8
● Sections 2~6 or more
● % 3dB BW: 1~3% or wider 1. Number of sections
● Maximum VSWR 1.5:1 (Typ) 2. Series Code
● Specific requirement on insertion loss, power 3. Package Code
handling available 4. Center Frequency(200MHz)
● Optimized structures for custom requirement 5. Bandwidth designator (same as LC
● Perfect temperture stability filter)
● Lowest parasitic passband 2FC (2.5Fc or more) 6. Bandwidth(5.5MHz)
7. Input connector (see page 40)
8. Output connector (see page 40)
39
Helical Cavity Filter
Sainty-Tech Communications Limited
♦Dimension
32
Sections 2 3 4 5 6
L(mm) 64 92 120 150 178
3.3
♦Connectors
Code O OP P L N L
L+19
Connectors SMA(F) SMA(M) Microstrip L16(F) N(F)
• Outline Drawing:
Example:
Fc=60MHz,N=5,
L=150(mm) without connector
W=74(mm)
H=32(mm)
4HL10-77.05/T3.9-O/O
6HL10-75.65/U2-O/O
4HL10-121.17/U2.5-O/O 3HL10-527.17/T4.8-O/O
Features To Order
● Suspended Substrate Design SSLPF – U4000 –O / O
● Cutoff Frequency: 800MHz~18000MHz 1 2 3 4 5
● Broad Band, Low Insertion Loss 1. Series Number
● Typical 0.05dB Chebyshev response 2. Designator of Bandwidth
● Quasi-elliptical response design and excellent shape factor 3. Cutoff Frequency(4000MHz)
● Maximum VSWR 2:1 within passband (typical 1.5:1) 4. Input Connector (see page 44)
● Perfect Temperature Stability 5. Output Connector (see page 44)
● 2FC parasitic passband or more
♦Typical Plots
SSLPF-U4000-O/O
Narrow Span Wide Span
♦Connectors
Code O OP P L N
44
Suspended Substrate SSHPF series
Suspended substrate highpass filter
Highpass Filter Frequency range:800~18000MHz
Sainty-Tech Communications Limited
♦Features To Order
● Suspended Substrate Design SSHPF – U6000 –O / O
● Cutoff Frequency Range 800MHz~18000MHz 1 2 3 4 5
● Broad Band Low Insertion Loss 1.Series Number
● Typical 0.05dB Chebyshev Response 2. Designator of Bandwidth(same as LC
● Quasi-elliptical design excellent shape factor highpass filter on page 17)
● Maximum VSWR 1.5:1( Typ 2:1) 3. Cutoff Frequency(6000MHz)
● Perfect Temperature Stability 4. Input connector (see page 45)
5. Output connector (see page 45)
Note:Only typical products are listed on the table ,custom cutoff frequency available with operating temp range -55~+85℃
45
Suspended substrate highpass filter
Sainty-Tech Communications Limited
♦Typical Plot
P/N:SSHPF-U5650-O/O
♦Connectors
Code O OP P L N
Outline Drawing
Note:Custom outline available
46
Coaxial Cavity Diplexer
Cavity Diplexer Frequency range:400~6000MHz
Sainty-Tech Communications Limited
Features To Order
• Coxial cavity filter design operating frequency 5 CB 20 – 1.7&1.82 / T 30 –O&O / O
400MHz~6000MHz 12 3 4 5 6 7 8
• Number of sections of each channel 2~10 (or 1. Number of sections
2. series(CB—“parallel”;CL—“in line”)
more)
• %3dB Bandwidth 0.6%~5%(or wider)
3. Package code——20
4. Center Frequency(1.7 和 1.82GHz)
• Maximum VSWR 1.2:1(Typ 1.3:1) 5. Bandwidth designator(same as LC
• Specific requirements on IL, power handling filter)
available 6. Bandwidth(30MHz)
• Optimized structures for custom requirement 7. Input connector (see page 47)
♦Specification
Freq Power Operating
Series FreqMHz BW/Fc×100% VSWR Impedance sections
Separation1) Handling Temp2)
Note:* General power handling is 10W, optimized design can reach 300W or better
1) Frequency Separation defined as (Fc2-Fc1)/BW3dB, BW3dB is the wider one of the two channel
2) Special requirement on operating temperature -55~+85℃ available
47
Coaxial Cavity Diplexer
Sainty-Tech Communications Limited
ISOLATION(dB)
N=6
The co-channel isolation at 4675 MHz is: 30
2
2
4675 − 5000 40
R= = −1.55
210 3
50 3
The curve indicate 64dB at 4675 MHz
4 4
•Following formula used to calculate the co-channel 60
5 5
isolation approximately: 6 6
L(dB)= 20×N×log10(2×|R|) 70
-4 -3 -2 -1 0 +1 +2 +3 +4
The result may be 4~9dB worse than actual one NUMBER OF 3dB BANDWIDTH
Then the result of previous example is 59dB.
♦Environmental Standard Special
♦Machamical ★Connectors
Package CB CL Code O OP P L
48
Rectangular Waveguide Diplexer Series
Cavity Diplexer Frequency range:5000~18000MHz
Sainty-Tech Communications Limited
Features To Order
• Frequency Range 5000MHz~18000MHz 5RB 20 – 8.5&8.65 / T 30 –O&O / O
• Section Number: 2~10 or more 12 3 4 5 6 7 8
• 3dB Bandwidth(%): 0.3%~4% or more
• Maximum VSWR 1.2:1 (Typ 1.3:1). 1. Number of Section
•Special requirements on IL or power handling available 2. Series(RB—“Parallel”;RL—“in line”)
• Custom optimized configuration available. 3. Package Code ——20
• The center frequency of two channel must be separated 4. Center Frequency(8.5 & 8.65GHz)
enough and can not fell into the parasitic band at same 5. Designator of Bandwidth
time 6. Bandwidth(30MHz)
7. Input Connector
8. Output Connector
♦Specification
BW/Fc× Freq Power Operating
Series FreqGHz VSWR 1) Impedance Section 2)
100% Separation Handling Temp
Note:* The average power handling is 20W in general, optimized design available for the customer.
1) Operating temperature -55~+85℃ available for the customers’ requirement.
49
Rectangular Waveguide Diplexer
Sainty-Tech Communications Limited
ISOLATION(dB)
Center Frequency Fc=8000 MHz 30
3dB BW=30 MHz 2 2
N=5 40
The co-channel isolation at f=8060 MHz is: 3
50 3
8060 − 8000 4
R= =2 4
30 60
The curve indicate isolation 61dB at f=8060 MHz
5 5
6 6
•Following formula used to calculate the 70
-4 -3 -2 -1 0 +1 +2 +3 +4
co-channel isolation approximately: NUMBER OF 3dB BANDWIDTH
L(dB) = 20×N×log10(2×|R|)
The result may be 4~9dB worse than actual one ♦Machanical
Then the result of previous example is 60.2dB • There is a design of blind screw thread
♦Environmental Standard Special hole for fixing for custom requirement
• Dimension
Vibration(5~2000Hz) 10G 20G
Length L 、 Width W and Height H
Shock(11 mSec) 10G 25G please refer to the section of
rectangular waveguid cavity filter and:
Relative Humidity 0~90% 95% L:
Storage Temp -40~+100℃ -55~+125℃ RB:L=LRB;
RL: L≈2LRB;
W and H:
RB:
Type E-E :W=2WRB,H=HRB;
Type F-F :W= WRB,H=2HRB。
RL:W=WRB,H=HRB。
♦Mechanical ★Connectors
Series RB RL Code O OP P B N
Type Parallel In line Connector SMA(F) SMA(M) Microstrip Flange N(F)
Features
Double Tuning 0.1dB Chebyshev response
High Q PIN diode tuning
Tuning Voltage: 0.3-20V(DC)
Input P-1: +10dBm(fc≥90MHz),
Selection Guide:
0dBm(fc<90MHz)
VT30-110 (30~110MHz),VT90-200(90~200MHz),
Tuning speed ≤50us(fc>30MHz)
VT200-400(200~400MHz),VT400-700(400~700MHz) ,
Typical 2~3 octave bandwidth coverage
VT550-865(550~865MHz)
within 30~1000MHz
Note:Custom frequency band available
small size microstrip output Ordering information:VT30-110-5-A, means: VT30-110
Operating Temperature:-40℃~+85℃
series, 5% 3dB bandwidth, A type package.
Specification
Electronical (Zo=50Ω)
Parameter
%3dB Bandwidth 3~10%
Fractional BW ripple1) ≤1%
I.L at center frequency2) 2~6dB
I.L variance 3) ≤2dB
Shape Factor (BW30/BW3) ≤7:1
Maximum VSWR 2.0:1max
Input P-1 +10dBm(TYP, fO≥90MHz)
0dBm(TYP, f<90MHz)
Tuning Voltage (VT): 0.3~20V
Note: 1) This is the difference of %3dB bandwidth within the frequency band, see Page 60-61 for typical curves
2) Insertion loss at center frequency is typical value, the wider passband the lower IL. Following method is used to calculate
insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB.
3) See Page 52-53 for typical curves
3.5
15 12.5 35 8.5
4-M1.6 2 15 12
16.5 deep 4
4-M2 2
Tolerance 0.5mm deep 5
31
1 RF input 5 RF output
1 RF input 2 RF output
2、4 Ground 3 Tuning port VT
3 Tuning port VT Housing grouded
Note
1. Custom outline available
2. The tuning voltage can be modified for custom requirement
3. Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
4. RF input and output ports are interchangeable
Typical Curve
P/N:VT30-110-5-A P/N:VT30-110-5-A
52
VT30-90~VT550-865 electronically tunable bandpass filters
Sainty-Tech Communications Limited
P/N:VT200-400-4-B P/N:VT200-400-4-B
P/N:VT400-700-4-B P/N:VT400-700-4-B
Features
Tuning Control: 8 bit parallel(TTL Level compatible)
Wide dynamic :Input P-1 =30dBm
2 ploe 0.1dB Chebyshev Response
Tuned speed ≤10us(fc>30MHz)
Up to 250 steps(Fc<120MHz) in band. Selection Guide:
Typical 2~3 octave bandwidth coverage within LBM017A-85(40~110MHz), LBM037A-85(30~90MHz),
30~700MHz LBM038A-85(30~110MHz), LBM039A-85(90~200MHz),
High bias voltage low bias current (100V/1.5mA) LBM040A-85(200~400MHz),LBM041A-85(225~450MHz)
Package : Pins or SMA connector LBM041A512-85(225~512MHz),
Small DIP package LBM700A-85(400~700MHz)
Operating Temperature range:-40℃~+85℃
Specification
Electrical
Parameters
%3dB Bandwidth 3~10%
Fractional BW flatness1) ≤1%
I.L at center frequency2) 2~6dB
3)
I.L variance ≤2dB
Shape Factor (BW30/BW3) ≤7:1
LBM017A-85
Impedance 50Ω
VSWR 2.0:1max
4)
Input P-1 +30dBm(TYP)
DC power: +5V/90mA
Vbb:+15~100V/1.5mA
Note: 1) This is the difference of % 3dB bandwidth within the frequency band, see Page 56 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method is used to
calculate insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB
3) See typical curves on page 56
4) Decided by the bias voltage, refer to the “Input P-1 --- Bias voltage”typical curve on page 55
LBM017A-85~LBM700A-85 Vbb=15~100V。
Note: A0~A7 are 8 control bit lines. Tune words from 00000000 to 11111010 results in the tuned frequency from lowest to
highest
⎛ f desired − f low ⎞
Tuneword = ⎜ ⎟ ×250 (Note: It will be 200 for LBM039A-85~LBM700A-85)
⎜ f −f ⎟
⎝ high low ⎠
Tuneword = ⎛⎜
50 − 30 ⎞ ×250=83D=53H
⎟
⎝ 90 − 30 ⎠
Notes
The accuracy of tune words is assured only with Vbb=85V which is the case of manufacture. A low Vbb can cause errors of tune
words so that you must declare to the factory of the exact Vbb used to adjust the errors before delivery.
1) The Input P-1 decided by the bias voltage, refer to the “Input P-1-Bias voltage”typical curve on this page
2) Replacement alternative for MICRO-POLE series of POLE/ZERO
3) Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
Typical Curves
30 30
Input power(dBm)
Input power(dBm)
Hz Hz
0M 0M
25 f= 4 z 25 f= 3
6 0 MH Hz
f= 0M
20 Hz 20 f= 6
0M Hz
1 1 0M
f= f= 9
15 15
10 10
15 30 45 60 85 100 15 30 45 60 85 100
Bias Voltage (V) Bias Voltage (V)
LBM039A -85(90-200MHz) LBM040A-85 (200-400MHz)
35 35
30 30
Input power(dBm)
Input power(dBm)
z
MH
MHz f=2
00
25 f=90 25
Hz
Hz =3 00M
20 50M 20 f Hz
f=1 z 400M
=
0MH f
15 f=20 15
10 10
15 30 45 60 85 100 15 30 45 60 85 100
4.0 -4.5
3.5 -5.0
30 50 70 90 30 50 70 90
frequency(MHz)
frequency(MHz)
5.0 -3.5
4.5 -4.0
4.0
-4.5
3.5
90 120 150 180 200 -5.0
frequency(MHz) 90 120 150 180 200
frequency(MHz)
LBM040A-85 (200-400MHz) LBM040A-85 (200-400MHz)
5.5 -4.0
3dB Bandwidth %
Insertion Loss(dB)
5.0 -4.5
4.5 -5.0
4.0 -5.5
3.5 -6.0
200 250 300 350 400 200 250 300 350 400
frequency(MHz) frequency(MHz)
56
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Communications Limited
P/N:LBM017A-85 P/N:LBM017A-85
LBM037A-85 LBM037A-85
57
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Communications Limited
P/N:LBM040A-85 P/N:LBM040A-85
LBM041A512-85 LBM041A512-85
58
Miniature Digitally DVT30-90~DVT550-865
Digitally tuned Fliter
Tuned Filters Frequency range:30~1000MHz
Sainty-Tech Communications Limited
Features
High “Q” varactor tuning circuit
Tuning control: 8 bit parallel (TTL compatible)
Input P-1: +10dBm(fc≥90MHz),
0dBm(fc<90MHz)
DC Power: 3~3.6V/10~15mA Selection Guide:
Double tuned 0.1dB Chebyshev response DVT30-90 (30~90MHz), DVT30-110 (30~110MHz)
Tuning Speed ≤50us(fc>30MHz) DVT90-200(90~200MHz),
Up to 251 tuning step DVT200-400(200~400MHz)
Typical 2~3 octave band cover the frequency DVT400-700(400~700MHz) ,
band 30~1000MHz DVT550-865(550~865MHz)
SMT Package (non-hermetic) Note: Custom frequency bands availalbe
Operating Temperature Range:-40℃~+85℃
Note: 1) difference of % 3dB bandwidth within the frequency band, see Page60-61 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method used to calculate
insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB
3) See Page 60-61 for the typical curves
Pin 1 2 3 4 5 6 7
Descrip Gnd A7 A6 A5 A4 A3 A2
Pin 8 9 10-13 14 15 16
Descrip A1 A0 N/C Vcc GND GND
Pin 17 18-28 29 30
Descrip RF GND RF GND
Vcc=+2.7~3.3V
DVT30-90~DVT550-865
Outline tolerance 0.5mm;
Example:If you wish to tune to 50MHz using a 30 to 90 MHz filter, the tune word is:
⎛ 50 − 30 ⎞ ×250=83D=53H
⎜ ⎟
⎝ 90 − 30 ⎠
Notes
1) The relationship between tuneword and frequency is only an approximate one.
2) Replacement alternative for MICRO-POLE series of POLE/ZERO
3) Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
4) RF input and output ports are interchangeable
5) Special frequency bands are available
Typical Plots
5.5 -2.5
5.0 -3.0
4.5 -3.5
4.0 -4.0
30 50 70 90 30 50 70 90
frequency(MHz) frequency(MHz)
5.0 -3.5
4.5 -4.0
4.0 -4.5
3.5 -5.0
90 120 150 180 200 90 120 150 180 200
frequency(MHz) frequency(MHz)
DVT200-400-4 DVT200-400-4
5.5 -2.5
3dB Bandwidth %
Insertion Loss(dB)
5.0 -3.0
4.5 -3.5
4.0 -4.0
3.5 -4.5
200 250 300 350 400 200 250 300 350 400
frequency(MHz) frequency(MHz)
P/N:DVT30-90-5 P/N:DVT30-90-5
P/N:DVT200-400-4 P/N:DVT200-400-4
P/N:DVT400-700-4 P/N:DVT550-865-4
62
Multiband Digitally tunned LBM042A~LBM043A
Digitally tuned hopping filter
Hopping filter Frequency range:1.5~450MHz
Sainty-Tech Communications Limited
Features
Tuning control:10 bit parallel(TTL compatible) Selection Guide:
Cascaded 2 pole 0.1dB chebyshev response LBM042A:1.5~4MHz,4~10MHz,10~30MHz
Tuning speed ≤10us(fc>30MHz) LBM043A:30~90MHz,90~200MHz,201~450MHz
Full band covering:
Notes:1) 250 hopping steps in each single band for fc<90MHz,
LBM042A SW (1.5~30MHz)、
LBM043A USW(30~450MHz) 200 hopping steps for fc>90MHz;
I/O Impedance:50Ω 2) Customized frequency band available within 700MHz.
Package:SMA (F) or pins
Operating Temperature:-40℃~+85℃
Specification
Electronical
Parameter
Tuning Range 1.5~30MHz(LBM042A),
30~450MHz(LBM043A)
3dB Bandwidth(%) 3~10%
Fractional BW variance1) ≤1%
I.L at Center frequency2) 7~8dB
Shape Factor (BW30/BW3) ≤7:1
Impedance 50Ω
Maximum VSWR 2.0:1max
Input P-13) 30dBm(TYP, fc≥30MHz)
DC power4): +5V/270mA
Vbb:+15~100V/5mA
Note:
1) This is the difference of % 3dB bandwidth within the frequency band, see Page 56 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method
used to calculate insertion loss not including the switching loss:IL ×BW3dB%=20~25, For example % BW
is 5% then IL is 4~5dB , Loss of switch is about 3dB;
3) Decided by the bias voltage, refer to the “Input P-1-Bias voltage”typical curve on page 55
4) Current saving mode available, which can low the current down to 90mA
Outline Drawing
16 12 4
6 ,5
119
PI N1 PI N15
119 ,5
115
M2 .5
(unit:mm)
Pinout
LBM042A~LBM043A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+5V GND A7 A6 A5 A4 A3 A2 A1 A0 N/C A8 A9 Vbb GND
Note: 1) A8~A9 are sub-band selection control bit lines. The words of Sub1, Sub2, Sub3 are 00B, 01B, 10B respectively. The
word 11B is for blocking
2) A0~A7 are 8 inband control bit lines. 0000000 control the lowest frequency FAH( < 90MHz) or C8H(>90MHz) control the
highest frequency
3) The binary tuning word is determined by both inband tuneword and frequency band selection word
⎛ f desired − f low ⎞
Tuning word in sub-band= ⎜ ⎟ ×( hopping step of subband)
⎜ f −f ⎟
⎝ high low ⎠
64