You are on page 1of 37

Combline Cavity Filter

Frequency range:400~11000MHz
Sainty-Tech Communications Limited

Features To Order :
● Center Frequency: 400MHz~11000MHz 5 FS 10 – 6575 / T 750 –O / O
● Typical 0.05dB Chebyshev response 12 3 4 5 6 7 8
● Sections 2~15 or more
● 3dB bandwidth: 1%~30% or more 1. Section Number
● Max VSWR 1.2:1 (typ1.5:1)。 2. Series Code(FS——“Combline”)
● Specific requirements on IL, power available 3. Package Code——type10
● Optimized structures for custom requirement 4. Center Frequency(6575MHz)
● 3FC parasitic passband (4Fc or more) 5. Designator of Bandwidth
6. Bandwidth(750MHz)
7. Input Connector (see Page29)
8. Output Connector (see Page29)

♦Specification
BW/Fc× Power Operating
Series Freq(MHz) VSWR Impedance Sections
100% Handling Temperature1)

FS 400-11000 1-30% 1.5:1 * 50Ω 2-15 -40~+60℃

Notes:* General power handling is 5W, optimized design can reach 300W or better.
1) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

28
Comline Cavity Filter
Sainty-Tech Communications Limited

♦Stopband Attenuation
•The right curve gives the stopband ♦Insertion Loss
attenuation for STC' s combline cavity filter. One of the characters of combline cavity filter is to
This curve shows the attenuation as multiples realize both narrow band and wide band design
of the 3dB bandwidth for FS series cavity
filter.The following formula is used in with low insertion loss.
calculating the stopband attenuation: •Typical Insertion Loss < 1.5dB
3dB Bw from Fc=
Fs − Fc •Broader passband lower IL
3dB BW •IL increase with the number of sections
Example: •1 section increase result 0.1dB IL increase
Center Frequency Fc=2600 MHz 10
3dB BW=200 MHz
20
Number of sections N=5
ATTENUATION(dB)
The attenuation at f1=2400 MHz: 30 2 2
2400 − 2600
R= = −1
200 40
The curve indicate attenuation is 30dB。
50 3 3

• Following formula used to calculate the


60 4 4
stopband attenuation approximately
5 7 7
LdB = 20×N×log10(2×|R|) 70 5
9 9
The result may be 5~10dB worse than the 13 13

actual one -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
♦Environmental Standard Special NUMBER OF 3dB BANDWIDTH
Vibration(5~2000Hz) 10G 20G
Shock(11 mSec) 10G 25G ♦Mechanical Features
Relative Humidity 0~90% 95% • Blind screw thread on the bottom it
Storage Temp -40~+100℃ -55~+125℃ can be determined by customers
• Width and Height shown in the
down left table
• Dimension:
L=(K)(N)+10(mm)
K=6~16 (TBD)
Example:
2.5GHz, N = 6, BW3dB= 1%
K=12
L=12×6+10 = 82 (mm)
W=40mm
H=18mm

♦Dimension ★Connectors
GHz
Freq 0.4-1 1-2 2-3 3-4 4-5 5-6 6-8 8-11 Code O OP P L N
mm
W 125 70 40 30 25 22 20 17
Connectors SMA(F) SMA(M) microstrip L16(F) N(F)
H mm 25 20 18 17 16 15 14 13

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


29
Interdigital Cavity Filter
Frequency range:600~18000MHz
Sainty-Tech Communications Limited

Features To order
● Frequency Range 600MHz~18000MHz 5 FD 10 – 8240 / T1200 –O / O
● Typical 0.05dB Chebyshev response 1 2 3 4 5 6 7 8
● Sections 2~11 or more
● %3dB Bandwidth 0.8%~80% or wider 1. Number of sections
● Maximum VSWR 1.3:1 (Typ 1.5:1)。 2. Series(FD——Interdigital)
● Specific requirements on IL, power available 3. Package Code——10
● Optimized structures for custom requirement 4. Center Frequency(8240MHz)
● 2×FC parasitic passband (2.5Fc or more) 5. Bandwidth Designator(same as LC
filter)
6. Bandwidth(1200MHz)
7. Input Connector (see Page 31)
8. Output Connector (see Page 31)

♦Specification
Power Operating
Series Freq(MHz) BW/Fc×100% VSWR Impedance sections
Handling Temp1)

FD 600-18000 0.8-80% 1.5:1 * 50Ω 2-11 -40~+60℃

Note:* General power handling is 5W, optimized design can reach 300W or better.
1) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

30
Interdigital Cavity Filter
Sainty-Tech Communications Limited

♦Stopband Attenuation ♦Insertion Loss


•The right curve gives the stopband attenuation for One of characters of interdigital cavity filter is
STC’s interdigital cavity filter. This curves show to realize broad passband with low
the attenuation as multiples of the 3dB bandwidth insertion loss
for FD series cavity filter.The following formula is •Typical insertion loss < 1dB
used in calculating the stopband attenuation: •Broader passband lower IL
3dB BW from Fc ( R )=
Fs − Fc • IL increase with the number of sections
3dB BW
Example:
Center Frequency F c=5600 MHz 20

ATTENUATION(dB)
3dB BW=500 MHz
Number of sections N=5 30
The attenuation at f1=6100 MHz:
2 2
6100 − 5600 40
R= = +1
500 3 3
The curve indicate attenuation is 30dB
50
•Following formula used to calculate the stopband 4 4
60
attenuation approximately 5 5
L
dB
= 20×N×log10(2×|R|)
6
6
70
This result may be 5~10dB worse than the
-4 -3 -2 -1 0 +1 +2 +3 +4
NUMBER OF 3dB BANDWIDTH
actual one
♦Environmental Standard Special
Vibration (5~2000Hz) 10G 20G
Shock (11 mSec) 10G 25G ♦Mechanical Features
Relative Humidity 0~90% 95% • Blind screw thread hole on the bottom
which can be determined by customers
Storage Temp -40~+100℃ -55~+125℃
• Width and height shown in the down left
table
• Dimension:
L=(K)(N)+10(mm)
K=6~14(TBD)
Example:
2.5GHz,6 sectoins, BW3dB = 3%,
K=10
L=10×6+10 = 70 (mm)
W=45mm
H=15mm

♦Dimension ★Connectors

FreqGHz 0.6-1 1-2 2-3 3-4 4-6 6-8 8-10 10-18 Code O OP P L N
mm
W 130 80 45 35 28 22 19 16
H mm
24 16 15 14 13 12 11 Connectors SMA(F) SMA(M) microstrip L16(F) N(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

31
Coaxial Cavity Filter
Cavity Filter Frequency range:400~6000MHz
Sainty-Tech Communications Limited

Features To Order
• Center Frequency range 400MHz-6000MHz 5 CC 20 – 4575 / T 760 –O / O
• Typical 0.05dB Chebyshev response 12 3 4 5 6 7 8
• Sections 2 to 10 or more
• % 3dB bandwidth 0.6%-5% or wider 1. Number of sections
• Maximum VSWR 1.2:1 (Typ 1.3:1) 2. Series(CC——“Coaxial”)
• Specific requirements on IL, power handling 3. Package Code ——2
available 4. Center Frequency(4575MHz)
• Optimized structures for custom requirement 5. Bandwidth Designator(same as LC filter)
• 2.5FC parasitic passband (4Fc or more) 6. Bandwidth(760MHz)
7. Input connector (see Page33)
8. Output connector (see Page33)

♦Specification

MHz
Power Opreating
Series Freq BW/Fc×100% VSWR Impedance Sections
Handling Temp1)

CC 400-6000 0.6-5% 1.3:1 * 50Ω 2-10 -40~+60℃

Note:* General power handling is 5W; optimized design can reach 300W or better
1) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


32
Coaxial Cavity Filter
Sainty-Tech Communications Limited

♦Stopband Attenuation ♦Insertion Loss


•The right curve gives the stopband attenuation for With high “Q” coaxial cavity filter can realize more
STC’s cavity filter. This curve shows the attenuation narrower passband than combline cavity filter at same
as multiples of the 3dB bandwidth for CC series cavity insertion loss
filter.Following formula is used in calculating the IL calculated as:
stopband attenuation:
IL = (Loss constants K)( N+0.5) +0.3
3dB BW fromFc( R ) =
Fs − Fc BW (%)
3dB BW BW(%)=BW/Fc×100
Example: K = 0.2 ~ 0.3
10
Center Frequency Fc=1832 MHz
3dB BW=18 MHz
20

ATTENUATION(dB)
N=5 the attenuation at 1796MHz is:
1796 − 1832
R= = −2 , 30
18 2
The curve indicate the attenuation is 62dB。 2
40
• Following formula used to calculate the stopband
attenuation approximately 3 3
50
L(dB)=20×N×log10(2×|R|)
4 4
The result may be 4~9dB worse than the actual 60
5 5
Then the result of previous example is 60.2dB 6 6
70
-4 -3 -2 -1 0 +1 +2 +3 +4
♦Environmental Standard Special NUMBER OF 3dB BANDWIDTH
Vibration(5~2000Hz) 10G 20G
♦Machanical Features
Shock(11 mSec) 10G 25G •Blind screw thread hole on the
bottom, which can be determined by
Relative Humidity 0~90% 95% customer
Storage Temp -40~+100℃ -55~+125℃ •Dimension shown in the down left
table, custom structure available
•Dimension and height:
L=(K+4)×N + 4 (mm)
W=K+8 (mm)
K=12~30 (TBD)

Example:
Fc=900MHz,N=6,BW=2.8%:
K=21
L=25×6+4 = 154 (mm)
H=70 mm
W=29 mm

★Connectors
♦Dimension
FreqGHz 0.6-1 1-2 2-3 3-4 4-5 5-6 Code O OP P L N

H mm
70 40 30 25 21 19 Connectors SMA(F) SMA(M) Microstri L16(F) N(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

33
Rectangular waveguide
Cavity Filter
Cavity Filter Frequency range:5000~18000MHz
Sainty-Tech Communications Limited

Features
To Order
• Center Frequency 5000~18000MHz
5 BJ 20 – 6000 / T 50 –O / O
• Typical TE101 design
12 3 4 5 6 7 8
• Section 2 to 10 or more
• %3dB BW: 0.3~4% or wider
1. Number of sections
• Maximum VSWR 1.2:1 (Typ1.3:1)。
2. Series(BJ—rectangular waveguide)
• Specific requirements on insertion loss, power
3. Package Code — 20
handling available
4. Center Frequency(6000MHz)
• Optimized structures for custom requirement
5. Bandwidth Designator(same as
• 1.4Fc parasitic passband
LC filter)
6. Bandwidth(50MHz)
7. Input connector
8. Output connector

★Connectors

Code O OP P B N
Connectors SMA(F) SMA(M) microstripp flange N(F)

♦Specification
Power Operating
Series FreqGHz BW/Fc×100% VSWR Impedance Sections
Handling Temp1)

BJ 5-18 0.3-4% 1.3:1 * 50Ω 2-10 -40~+60℃

Note:* General power handling is 20W; optimized design can reach better
1) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

34
Rectangular waveguide Cavity Filter
Sainty-Tech Communications Limited

♦Stopband Attenuation
♦Insertion Loss
•The right curve gives the stopband
With higher “Q” rectangular waveguide cavity filter can
attenuation for STC' s rectangular
waveguide cavity filter. This curve shows the realize more narrower passband than coaxial cavity filter
attenuation as multiples of the 3dB bandwidth with same insertion loss
for BJ series cavity filter.Following formula is IL calculated as:
used to calculating the stopband attenuation: K ( N+0.5)
3dB BW from Fc ( R )=
Fs − Fc IL =
BW(%)
+0.3
3dB BW BW%=BW/Fc×100
Example: K = 0.1
Center Frequency Fc=8000 MHz
3dB BW=30 MHz 10
N=5
The attenuation at 8045 MHz:
20

ATTENUATION(dB)
R = 8045 − 8000 = 1.5 30
30
2
2
The curve indicate the attenuation is 46dB 40
•Following formula used to calculate the 3 3
50
stopband attenuation approximately:
L(dB) = 20×N×log10(2×|R|) 4 4
The result may be 4~9dB worse than
60
5 5
actual 6 6
Then the result of previous example is 70
47.7dB -4 -3 -2 -1 0 +1 +2 +3 +4
NUMBER OF 3dB BANDWIDTH
♦Environmental Standard Special
Vibration(5~2000Hz) 10G 20G
Shock(11 mSec) 10G 25G ♦Machanical Features
Relative Humidity 0~90% 95% •Customer can determine blind screw
thread hole on the bottom
Storage Temp -40~+100℃ -55~+125℃
•Dimension shown in the down left
table, custom structure available
•Dimension and height:
L=(W-4)×N+4 (mm)
H= W/2 + 1 (mm)

Example:
Fc=8000MHz,N=5,BW=0.35%,
W = 33.9 (mm)
L=(33.9-4)×5+4 = 153.9(mm)
H = 17.9 (mm)

♦Specification
FreqGHz 5-6 6-7 7-8 8-9 9-10 10-11 11-12 12-13 13-14 14-15 15-18
mm
W 49.5 42.5 37.6 33.9 31 28.7 26.9 25.3 24.0 22.8 20

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

35
Dielectric Loaded
Cavity Filter
Cavity Filter Frequency range:1500~18000MHz
Sainty-Tech Communications Limited

Features To Order
● Center Frequency 1500MHz~18000MHz 5 HD 10 – 8200 / H50 –O / O
● Typical 0.05dB Chebyshev response 1 2 3 4 5 6 7 8
Quasi-elliptical response and linear 1. Number of sections
phase design available 2. Series
● Sections 2~8 or more 3. Outline code (10—“Parallel”;20—“in line”)
● % 3dB BW: 1‰~6‰(or wider) 4. Center Frequency(8200MHz)
● VSWR 1.2:1 (Typ 1.3:1) 5. Bandwidth designator(same as LC filter)
● Flexiable structure design 6. Bandwidth(50MHz)
● Dielectric temperature compensation 7. Input Connector ( see Page 38)
design perfect temperature stability 8. Output Connector (see Page 38)
● Parasitic passband lower to 1.15×Fc
● Custom outline available

HD10 Outline Drawing

HD20 Outline Drawing

♦Specification

BW/Fc× Power Operating


Series Freq(MHz) VSWR Impedance Sections
100% Handling Temp1)

HD 1500-18000 1‰-8‰ 1.3:1 * 50Ω 2-8 -40~+60℃

Note:* General power handling is 5W; optimized design can reach 10W
1) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


36
Dielectric Loaded Cavity Filter
Sainty-Tech Communications Limited

♦Environmental standard special ♦Insertion Loss


Vibration(5~2000Hz) 10G 20G With high “Q” dielectric cavity filter can realize very
Shock(11mSec) 10G 25G narrow band. Adjustable dielectric temperature coefficient
Humidity 0~90% 95% can satisfy the requirement for wide operating temp
Storage Temp -40~+100℃ -55~+125℃ The IL calculated as:
( (Loss constants K)( N+0.5)
IL=
♦Stopband Attenuation +0.3
BW(%)
The right two cluster of curves give the attenuation for
STC’s HD series cavity filter. Those curves show BW(%)=BW 3dB/Fc×100
the attenuation as multiples of the 3Db bandwidth for Loss constants K = 0.1 ~ 0.2
HD series cavity filter. Following formula is used in
calculating the stopband attenuation:
3dB BW from Fc (R)=
Fs − Fc
% 3dB Bandwidth 1‰~3‰
3dB BW
10
Example:
Center Frequency Fc=4300 MHz 20
3dB BW=20 MHz 2
30 2
DEGRESSION(dBc)

3
N=6
The attenuation at f=4250 MHz: 3
40 4
4250 − 4300
R= = −2 . 5 4
20 50
5
The curve indicate the attenuation 64dBc at f
60 5

♦Machanical Features
• Two options,Blind screw thread hole and through 70 6
6
hole, for customer. please contact the factory for the
hole size 80
-5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
•Height shown in the table of dimension
NUMBER OF 3dB BANDWIDTH
• Dimension:
L:
Type 10:L=(K+3.5)×0.5N+(0~4.5)(mm)
Type 20:L=(K+3.5)×N+(0~4.5)(mm) % 3dB Bandwidth 3‰~6‰
W:
10
Type 10:W =K×2+(9~11.5)(mm)
Type 20:W =K+(6~8)(mm)
K=10~39(see table of dimension) 20
Example:(type 10) 2
DEGRESSION(dBc)

Fc=8.15GHz,N=6,BW3dB=5‰,Then 30 2
K=11
L=(11+3.5)×3+2.5=46(mm) 40 3
W=11×2+10=32(mm)
3
H=12(mm) 50 4

60 4 5

5
70 6
6
80
-5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
HD20 Outline Drawing
NUMBER OF 3dB BANDWIDTH

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

37
Dielectric Loaded Cavity Filter
Sainty-Tech Communications Limited

♦Dimension ♦Typical Curves


6HD10–4310.9/T15–O/O (69×47.5×18mm)
GHz
Freq 1.5-3 3-5 5-7 8-11 11-18
mm
H 32 18 13 12 12
Kmm 39 18 13 11 10
Note:H without the height of screw

★Connectors

Code O OP P L N

Connector SMA(F) SMA(M) Microstrip L16(F) N(F)

4HD10–6072/T22.3–O/O (37.5×37.5×13mm) 4HD10–8330.25/T17.11–O/O (32×32×12mm)

6HD10–8297.1/T15.6–O/O (46×32×12mm) 6HD10–9899.8/T35.6–O/O (45×31×12mm)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

38
HL Series
Helical Cavity Filter
Helical Cavity Filter Frequency range:30~550MHz
Sainty-Tech Communications Limited

Features To Order
● Frequency Range 30MHz~550MHz 5 HL 10 – 200 / T5.5 –O / O
● Typical 0.05dB Cheybshev response 12 3 4 56 7 8
● Sections 2~6 or more
● % 3dB BW: 1~3% or wider 1. Number of sections
● Maximum VSWR 1.5:1 (Typ) 2. Series Code
● Specific requirement on insertion loss, power 3. Package Code
handling available 4. Center Frequency(200MHz)
● Optimized structures for custom requirement 5. Bandwidth designator (same as LC
● Perfect temperture stability filter)
● Lowest parasitic passband 2FC (2.5Fc or more) 6. Bandwidth(5.5MHz)
7. Input connector (see page 40)
8. Output connector (see page 40)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

39
Helical Cavity Filter
Sainty-Tech Communications Limited

♦Specification Standard Special


Center Freq(Fc) 30~550MHz 20~600MHz ♦Insertion Loss
% 3dB BW 2~6 0.9~7
VSWR 1.5:1 1.2:1
Insertion loss at center frequency calculated:
IL see right formula ――
(Loss constant K)( N+0.5)
Stopband Att see right curve ――
BW(%)
Average Power(W) (3×%BW) / K 20
BW(%)=BW3dB/Fc×100
Peak Power(W) 15×%BW 100
Parasitic Passband 2.5×Fc (3~4)×Fc
Operatinf Temp -40~+60℃ -55~+85℃ Loss constant
Note:K is loss constant , see right table Center 30 51 70 101 301
Freq to to to to to
♦Environmental Standard Special
(MHz) 50 70 100 300 600
Vibration(5~2000Hz) 10G 20G
Shock(11 mSec) 10G 25G K 1.9 1.6 1.5 1.4 1.0
Relative Humidity 0~90% 95%
Storage Temp -40~+100℃ -55~+125℃
♦Stopband Attenuation
•The right curve gives the stopband attenuation for 10
STC’s helical cavity filter. This curve shows the
20
attenuation as multiples of the 3dB bandwidth for HL
ATTENUATION(dB)

series cavity filter. Following formula is used in 30 2 2


calculating the stopband attenuation:
3dB BW from Fc (R)=
Fs − Fc 40
3dB BW
3 3
50
Example:
Center Frequency Fc=140 MHz 60 4 4
3dB BW=2 MHz 5 6 6 5
70
N=4 -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5
The attenuation at Fs of f1=135 MHz is: NUMBER OF 3dB BANDWIDTH
R= 135 − 140 = −2.5
2
The curve indicate the attenuation 54dB at f1

♦Dimension
32
Sections 2 3 4 5 6
L(mm) 64 92 120 150 178
3.3

FreqMHz 30-50 50-65 65-100 100-550


W(mm) 100 74 60 48
W
1
3i
t
y
p
c
a
l

♦Connectors
Code O OP P L N L
L+19
Connectors SMA(F) SMA(M) Microstrip L16(F) N(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


40
Helical Cavity Filter
Sainty-Tech Communications Limited

♦Machanical Features ♦Typical Plot


• Two options for mounting, blind screw thread hole
and through hole which can be determined by 4HL10-57.53/T0.63-O/O
customer

• Width and Length shown in the table of dimension

• Outline Drawing:
Example:
Fc=60MHz,N=5,
L=150(mm) without connector
W=74(mm)
H=32(mm)

Narrow Span Wide Span


4HL10-189.63/T6.2-O/O

4HL10-77.05/T3.9-O/O

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


41
Helical Cavity Filter
Sainty-Tech Communications Limited

6HL10-75.65/U2-O/O

Narrow Span Wide Span

4HL10-121.17/U2.5-O/O 3HL10-527.17/T4.8-O/O

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


42
Suspended Substrate SSLPF series Suspended substrate
lowpass filter
Lowpass Filter Frequency range:800~18000MHz
Sainty-Tech Communications Limited

Features To Order
● Suspended Substrate Design SSLPF – U4000 –O / O
● Cutoff Frequency: 800MHz~18000MHz 1 2 3 4 5
● Broad Band, Low Insertion Loss 1. Series Number
● Typical 0.05dB Chebyshev response 2. Designator of Bandwidth
● Quasi-elliptical response design and excellent shape factor 3. Cutoff Frequency(4000MHz)
● Maximum VSWR 2:1 within passband (typical 1.5:1) 4. Input Connector (see page 44)
● Perfect Temperature Stability 5. Output Connector (see page 44)
● 2FC parasitic passband or more

♦Typical Specification (Impedance 50Ω)


Freq IL VSWR Cutoff Freq Stopband Power Dimension(mm)
P/N Range (dB) (TYP) Attenuation Handling
(GHz)
(GHz) (dB) (W) L W H
SSLPF–U1000–O/O DC-1 1.0 1.5:1 1.15-3 50 15 63 45 11
SSLPF–U2000–O/O DC-2 1.0 1.5:1 2.3-5 50 15 59 42 11
SSLPF–U3000–O/O DC-3 1.0 1.5:1 3.4-6.7 50 15 57 37 11
SSLPF–U4000–O/O DC-4 1.0 1.5:1 4.6-8.6 50 15 55 30 11
SSLPF–U5000–O/O DC-5 1.0 1.5:1 5.8-10.8 50 15 44 30 11
SSLPF–U6000–O/O DC-6 1.0 1.5:1 6.9-13 50 15 40 27 11
SSLPF–U7000–O/O DC-7 1.0 1.7:1 8-15 50 15 37 27 11
SSLPF–U8000–O/O DC-8 1.0 1.7:1 9.2-16 50 15 33 27 11
SSLPF–U9000–O/O DC-9 1.0 1.7:1 10.4-16.5 50 15 33 27 11
SSLPF–U10000–O/O DC-10 1.0 1.8:1 11.5-17 50 15 31 25 11
SSLPF–U11000–O/O DC-11 1.0 1.8:1 12.7-17.5 45 15 30 25 11
SSLPF–U12000–O/O DC-12 1.0 1.8:1 13.8-20 40 15 30 23 11
SSLPF–U13000–O/O DC-13 1.0 1.8:1 15-18.8 40 15 28 23 11
SSLPF–U14000–O/O DC-14 1.0 1.8:1 16.1-19.6 40 15 28 20 11
SSLPF–U15000–O/O DC-15 1.0 1.9:1 17.3-21 40 15 27 20 11
SSLPF–U16000–O/O DC-16 1.0 1.9:1 18.4-21.5 40 15 26 19 11
SSLPF–U17000–O/O DC-17 1.0 1.9:1 19.6-22 40 15 26 19 11
SSLPF–U18000–O/O DC-18 1.0 1.9:1 20.7-24 40 15 25 15 11
Note:
1. Only typical products are listed on this table,custom cutoff frequency available with temperature range
of -55~+85℃.
♦Enviromental Standard Special ♦Mechanical Features
Vibration(5~2000Hz) 10G 20G • Dimension see the table boue 43
Shock(11 mSec) 10G 25G • Two options for mounting, blind screw thread
Humidity 0~90% 95% hole and through hole
Storage Temperature -40~+100℃ -55~+125℃

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


43
Suspended substrate lowpass filter
Sainty-Tech Communications Limited

♦Typical Plots
SSLPF-U4000-O/O
Narrow Span Wide Span

♦Connectors

Code O OP P L N

Connector SMA(F) SMA(M) microstrip L16(F) N(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

44
Suspended Substrate SSHPF series
Suspended substrate highpass filter
Highpass Filter Frequency range:800~18000MHz
Sainty-Tech Communications Limited

♦Features To Order
● Suspended Substrate Design SSHPF – U6000 –O / O
● Cutoff Frequency Range 800MHz~18000MHz 1 2 3 4 5
● Broad Band Low Insertion Loss 1.Series Number
● Typical 0.05dB Chebyshev Response 2. Designator of Bandwidth(same as LC
● Quasi-elliptical design excellent shape factor highpass filter on page 17)
● Maximum VSWR 1.5:1( Typ 2:1) 3. Cutoff Frequency(6000MHz)
● Perfect Temperature Stability 4. Input connector (see page 45)
5. Output connector (see page 45)

♦Typical Specification ( Impedance 50Ω)


Freq Stopband Stopband Power Dimension(mm)
IL VSWR
Part Number Range Freq Attenuation Handling
(dB) (TYP)
(GHz) (GHz) (dB) (W) L W H

SSHPF – U1000–O/O 1-3 1.0 1.5:1 DC-0.85 50 15 40 40 11

SSHPF – U2000–O/O 2-6 1.0 1.5:1 DC-1.7 50 15 40 33 11

SSHPF – U3000–O/O 3-9 1.0 1.5:1 DC-2.6 50 15 37 30 11

SSHPF – U4000 –O/O 4-12 1.0 1.5:1 DC-3.4 50 15 35 27 11

SSHPF – U5000–O/O 5-16 1.0 1.6:1 DC-4.2 50 15 33 26 11

SSHPF – U6000–O/O 6-18 1.0 1.8:1 DC-4.75 50 15 30 25 11

SSHPF – U7000–O/O 7-18 1.0 1.8:1 DC-5.9 50 15 30 25 11

SSHPF – U8000–O/O 8-18 1.0 1.8:1 DC-6.8 50 15 30 24 11

SSHPF – U9000–O/O 9-18 1.0 1.8:1 DC-7.6 50 15 30 24 11

SSHPF– U10000–O/O 10-18 1.0 1.8:1 DC-8.5 50 15 28 22 11

SSHPF– U11000 –O/O 11-18 1.0 1.8:1 DC-9.3 50 15 28 21 11

SSHPF– U12000 –O/O 12-18 1.0 1.8:1 DC-10.2 50 15 26 20 11

Note:Only typical products are listed on the table ,custom cutoff frequency available with operating temp range -55~+85℃

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

45
Suspended substrate highpass filter
Sainty-Tech Communications Limited

♦Enviromental Standard Special ♦Mechanical Features


Vibration(5~2000Hz) 10G 20G •Dimension see page 45
Shock(11 mSec) 10G 25G •Two options for mounting, blind screw thread
Humidity 0~90% 95% hole and through hole
Storage Temperature -40~+100℃ -55~+125℃

♦Typical Plot
P/N:SSHPF-U5650-O/O

♦Connectors

Code O OP P L N

Connector SMA(F) SMA(M) microstrip L16(F) N(F)

Outline Drawing
Note:Custom outline available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

46
Coaxial Cavity Diplexer
Cavity Diplexer Frequency range:400~6000MHz
Sainty-Tech Communications Limited

Features To Order
• Coxial cavity filter design operating frequency 5 CB 20 – 1.7&1.82 / T 30 –O&O / O
400MHz~6000MHz 12 3 4 5 6 7 8
• Number of sections of each channel 2~10 (or 1. Number of sections
2. series(CB—“parallel”;CL—“in line”)
more)
• %3dB Bandwidth 0.6%~5%(or wider)
3. Package code——20
4. Center Frequency(1.7 和 1.82GHz)
• Maximum VSWR 1.2:1(Typ 1.3:1) 5. Bandwidth designator(same as LC
• Specific requirements on IL, power handling filter)
available 6. Bandwidth(30MHz)
• Optimized structures for custom requirement 7. Input connector (see page 47)

• The center frequency of two channel must be


8. Output connector (see page 47)

separated enough and not fell into the


parasitic band (Fc2=2.5Fc1 ) at same time.

♦Specification
Freq Power Operating
Series FreqMHz BW/Fc×100% VSWR Impedance sections
Separation1) Handling Temp2)

CB、CL 400-6000 0.6-5% 1.3:1 >2.4:1 * 50Ω 2-10 -40~+60℃

Note:* General power handling is 10W, optimized design can reach 300W or better
1) Frequency Separation defined as (Fc2-Fc1)/BW3dB, BW3dB is the wider one of the two channel
2) Special requirement on operating temperature -55~+85℃ available

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

47
Coaxial Cavity Diplexer
Sainty-Tech Communications Limited

♦Co-Channel Isolation ♦Insertion Loss


•The right curve gives the co-channel isolation. This Coaxial cavity diplexer consist of two
curves show the co-channel isolation as multiples of the filters ,“T” combiner. Thereby the
3dB bandwidth for CB(CL) series diplexer. Following calculation of insertion loss of diplexer
formula used in calculating the co-channel isolation: can refer to the method of calculation of
R=
Fs − Fc Example: coaxial cavity filter.
3dB BW
10
Center Frequency Fc=5000 MHz
3dB BW=210 MHz 20

ISOLATION(dB)
N=6
The co-channel isolation at 4675 MHz is: 30
2
2
4675 − 5000 40
R= = −1.55
210 3
50 3
The curve indicate 64dB at 4675 MHz
4 4
•Following formula used to calculate the co-channel 60
5 5
isolation approximately: 6 6
L(dB)= 20×N×log10(2×|R|) 70
-4 -3 -2 -1 0 +1 +2 +3 +4
The result may be 4~9dB worse than actual one NUMBER OF 3dB BANDWIDTH
Then the result of previous example is 59dB.
♦Environmental Standard Special

Vibration(5~2000Hz) 10G 20G


♦Machanical
• There are blind screw thread of fixing
Shock(11 mSec) 10G 25G for customer requirements
• Dimension
Relative Humidity 0~90% 95% Length L、Width W and Height H can r
Storage Temp -40~+100℃ -55~+125℃ efer to the section of coxial cavity
filter and:
L:
CB:L=Lcc;
CL: L≈2Lcc;
W and H:
CB:
F-F W= Wcc,H=2Hcc
E-E W=2Wcc,H= Hcc。
CL:W= Wcc,H= Hcc。

Note:Left figure is the type F-F of CB


series

♦Machamical ★Connectors
Package CB CL Code O OP P L

Type Parallel In line Connectors SMA(F) SMA(M) Microstrip L16(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

48
Rectangular Waveguide Diplexer Series
Cavity Diplexer Frequency range:5000~18000MHz
Sainty-Tech Communications Limited

Features To Order
• Frequency Range 5000MHz~18000MHz 5RB 20 – 8.5&8.65 / T 30 –O&O / O
• Section Number: 2~10 or more 12 3 4 5 6 7 8
• 3dB Bandwidth(%): 0.3%~4% or more
• Maximum VSWR 1.2:1 (Typ 1.3:1). 1. Number of Section
•Special requirements on IL or power handling available 2. Series(RB—“Parallel”;RL—“in line”)
• Custom optimized configuration available. 3. Package Code ——20
• The center frequency of two channel must be separated 4. Center Frequency(8.5 & 8.65GHz)
enough and can not fell into the parasitic band at same 5. Designator of Bandwidth
time 6. Bandwidth(30MHz)
7. Input Connector
8. Output Connector

♦Specification
BW/Fc× Freq Power Operating
Series FreqGHz VSWR 1) Impedance Section 2)
100% Separation Handling Temp

RB、RL 5-18 0.3-4% 1.3:1 >2.2:1 * 50Ω 2-10 -40~+60℃

Note:* The average power handling is 20W in general, optimized design available for the customer.
  1) Operating temperature -55~+85℃ available for the customers’ requirement.

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

49
Rectangular Waveguide Diplexer
Sainty-Tech Communications Limited

♦Co-Channel Isolation ♦Insertion Loss


•The right curve gives the co-channel isolation of Rectangular waveguide cavity diplexer consists of
channel 1&2. This curves show the co-channel as two cavity filters 'T" combiner. Thereby the
multiples of the 3dB R for RB(RL) series diplexer. calculation of insertion loss of diplexer can refer to
Following formula used in calculating the co-channel the method of calculation of Rectangular cavity filter
isolation ( When two channel differ in the number of
sections there are two co-channel isolations G1、G2):
10
R=
Fs − Fc
3dB BW
20
Example:

ISOLATION(dB)
Center Frequency Fc=8000 MHz 30
3dB BW=30 MHz 2 2
N=5 40
The co-channel isolation at f=8060 MHz is: 3
50 3
8060 − 8000 4
R= =2 4
30 60
The curve indicate isolation 61dB at f=8060 MHz
5 5
6 6
•Following formula used to calculate the 70
-4 -3 -2 -1 0 +1 +2 +3 +4
co-channel isolation approximately: NUMBER OF 3dB BANDWIDTH
L(dB) = 20×N×log10(2×|R|)
The result may be 4~9dB worse than actual one ♦Machanical
Then the result of previous example is 60.2dB • There is a design of blind screw thread
♦Environmental Standard Special hole for fixing for custom requirement
• Dimension
Vibration(5~2000Hz) 10G 20G
Length L 、 Width W and Height H
Shock(11 mSec) 10G 25G please refer to the section of
rectangular waveguid cavity filter and:
Relative Humidity 0~90% 95% L:
Storage Temp -40~+100℃ -55~+125℃ RB:L=LRB;
RL: L≈2LRB;
W and H:
RB:
Type E-E :W=2WRB,H=HRB;
Type F-F :W= WRB,H=2HRB。
RL:W=WRB,H=HRB。

Note:Left figure is the type E-E of RB


series

♦Mechanical ★Connectors

Series RB RL Code O OP P B N
Type Parallel In line Connector SMA(F) SMA(M) Microstrip Flange N(F)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


50
Electronically tunable VT30-90~VT550-865
Electronically tunable filter
Bandpass Filter Frequency range:30~1000MHz
Sainty-Tech Communications Limited

Features
Double Tuning 0.1dB Chebyshev response
High Q PIN diode tuning
Tuning Voltage: 0.3-20V(DC)
Input P-1: +10dBm(fc≥90MHz),
Selection Guide:
0dBm(fc<90MHz)
VT30-110 (30~110MHz),VT90-200(90~200MHz),
Tuning speed ≤50us(fc>30MHz)
VT200-400(200~400MHz),VT400-700(400~700MHz) ,
Typical 2~3 octave bandwidth coverage
VT550-865(550~865MHz)
within 30~1000MHz
Note:Custom frequency band available
small size microstrip output Ordering information:VT30-110-5-A, means: VT30-110
Operating Temperature:-40℃~+85℃
series, 5% 3dB bandwidth, A type package.

Specification
Electronical (Zo=50Ω)
Parameter
%3dB Bandwidth 3~10%
Fractional BW ripple1) ≤1%
I.L at center frequency2) 2~6dB
I.L variance 3) ≤2dB
Shape Factor (BW30/BW3) ≤7:1
Maximum VSWR 2.0:1max
Input P-1 +10dBm(TYP, fO≥90MHz)
0dBm(TYP, f<90MHz)
Tuning Voltage (VT): 0.3~20V

Note: 1) This is the difference of %3dB bandwidth within the frequency band, see Page 60-61 for typical curves
2) Insertion loss at center frequency is typical value, the wider passband the lower IL. Following method is used to calculate
insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB.
3) See Page 52-53 for typical curves

Environmental Standard Special Standard Special

Vibration(5~2000Hz) 10G 20G Operating Temp -40~+60℃ -40~+85℃

Shock(11 mSec) 30G 50G Storage Temp -40~+100℃ -55~+125℃

Relative Humidity 0~90% 95%

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


51
VT30-90~VT550-865 electronically tunable bandpass filters
Sainty-Tech Communications Limited

Outline and Pinout


Package A (for VT30-110 series) Package B (for VT90-200~VT550-865 series)
2
19 8

3.5
15 12.5 35 8.5

4-M1.6 2 15 12
16.5 deep 4

4-M2 2
Tolerance 0.5mm deep 5
31

1 RF input 5 RF output
1 RF input 2 RF output
2、4 Ground 3 Tuning port VT
3 Tuning port VT Housing grouded

Note
1. Custom outline available
2. The tuning voltage can be modified for custom requirement
3. Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
4. RF input and output ports are interchangeable

Typical Curve

P/N:VT30-110-5-A P/N:VT30-110-5-A

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

52
VT30-90~VT550-865 electronically tunable bandpass filters
Sainty-Tech Communications Limited

P/N:VT200-400-4-B P/N:VT200-400-4-B

P/N:VT400-700-4-B P/N:VT400-700-4-B

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


53
Digitally tuned LBM017A-85~LBM700A-85
Digitally tuned Hopping filter
Hopping filter Frequency range:30~700MHz
Sainty-Tech Communications Limited

Features
Tuning Control: 8 bit parallel(TTL Level compatible)
Wide dynamic :Input P-1 =30dBm
2 ploe 0.1dB Chebyshev Response
Tuned speed ≤10us(fc>30MHz)
Up to 250 steps(Fc<120MHz) in band. Selection Guide:
Typical 2~3 octave bandwidth coverage within LBM017A-85(40~110MHz), LBM037A-85(30~90MHz),
30~700MHz LBM038A-85(30~110MHz), LBM039A-85(90~200MHz),
High bias voltage low bias current (100V/1.5mA) LBM040A-85(200~400MHz),LBM041A-85(225~450MHz)
Package : Pins or SMA connector LBM041A512-85(225~512MHz),
Small DIP package LBM700A-85(400~700MHz)
Operating Temperature range:-40℃~+85℃
Specification
Electrical
Parameters
%3dB Bandwidth 3~10%
Fractional BW flatness1) ≤1%
I.L at center frequency2) 2~6dB
3)
I.L variance ≤2dB
Shape Factor (BW30/BW3) ≤7:1
LBM017A-85
Impedance 50Ω
VSWR 2.0:1max
4)
Input P-1 +30dBm(TYP)
DC power: +5V/90mA
Vbb:+15~100V/1.5mA

Note: 1) This is the difference of % 3dB bandwidth within the frequency band, see Page 56 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method is used to
calculate insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB
3) See typical curves on page 56
4) Decided by the bias voltage, refer to the “Input P-1 --- Bias voltage”typical curve on page 55

Environmental Standard Special Standard Special

Vibration(5~2000Hz) 10G 20G Operating Temp -40~+60℃ -40~+85℃

Shock(11 mSec) 30G 50G Storage Temp -40~+100℃ -55~+125℃

Relative HUmidity 0~90% 95%

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


54
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Com

Dimension and Pinout


LBM017A-85~LBM700A-85 have a same outline and pinout as LBM034A~LBM700A

LBM017A-85~LBM700A-85 Vbb=15~100V。

Note: A0~A7 are 8 control bit lines. Tune words from 00000000 to 11111010 results in the tuned frequency from lowest to
highest
⎛ f desired − f low ⎞
Tuneword = ⎜ ⎟ ×250 (Note: It will be 200 for LBM039A-85~LBM700A-85)
⎜ f −f ⎟
⎝ high low ⎠

Example:The tuneword of LBM037A-85 at fc=50MHz is:

Tuneword = ⎛⎜
50 − 30 ⎞ ×250=83D=53H

⎝ 90 − 30 ⎠
Notes
The accuracy of tune words is assured only with Vbb=85V which is the case of manufacture. A low Vbb can cause errors of tune
words so that you must declare to the factory of the exact Vbb used to adjust the errors before delivery.
1) The Input P-1 decided by the bias voltage, refer to the “Input P-1-Bias voltage”typical curve on this page
2) Replacement alternative for MICRO-POLE series of POLE/ZERO
3) Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
Typical Curves

Input power (P-1) via Vbb


LBM017A -85(40-110MHz) LBM037A-85 (30-90MHz)
35 35

30 30
Input power(dBm)

Input power(dBm)

Hz Hz
0M 0M
25 f= 4 z 25 f= 3
6 0 MH Hz
f= 0M
20 Hz 20 f= 6
0M Hz
1 1 0M
f= f= 9
15 15
10 10
15 30 45 60 85 100 15 30 45 60 85 100
Bias Voltage (V) Bias Voltage (V)
LBM039A -85(90-200MHz) LBM040A-85 (200-400MHz)
35 35

30 30
Input power(dBm)
Input power(dBm)

z
MH
MHz f=2
00
25 f=90 25
Hz
Hz =3 00M
20 50M 20 f Hz
f=1 z 400M
=
0MH f
15 f=20 15

10 10
15 30 45 60 85 100 15 30 45 60 85 100

Bias Voltage (V) Bias Voltage (V)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


55
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Communications Limited

%3dB bandwidth Insertion loss vs. Frequency


LBM037A-85 (30-90MHz) LBM037A-85 (30-90MHz)
5.5 -3.0
3dB Bandwidth %

Insertion Loss (dB)


5.0 -3.5
4.5 -4.0

4.0 -4.5

3.5 -5.0
30 50 70 90 30 50 70 90
frequency(MHz)
frequency(MHz)

LBM039A-85 (90-200MHz) LBM039A-85 (90-200MHz)


5.5 -3.0
Insertion Loss (dB)
3dB Bandwidth %

5.0 -3.5
4.5 -4.0
4.0
-4.5
3.5
90 120 150 180 200 -5.0
frequency(MHz) 90 120 150 180 200
frequency(MHz)
LBM040A-85 (200-400MHz) LBM040A-85 (200-400MHz)
5.5 -4.0
3dB Bandwidth %

Insertion Loss(dB)

5.0 -4.5

4.5 -5.0

4.0 -5.5

3.5 -6.0
200 250 300 350 400 200 250 300 350 400
frequency(MHz) frequency(MHz)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

56
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Communications Limited

P/N:LBM017A-85 P/N:LBM017A-85

LBM037A-85 LBM037A-85

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

57
LBM017A-85~LBM700A-85 Digitally tuned Hopping filter
Sainty-Tech Communications Limited

P/N:LBM040A-85 P/N:LBM040A-85

LBM041A512-85 LBM041A512-85

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

58
Miniature Digitally DVT30-90~DVT550-865
Digitally tuned Fliter
Tuned Filters Frequency range:30~1000MHz
Sainty-Tech Communications Limited

Features
High “Q” varactor tuning circuit
Tuning control: 8 bit parallel (TTL compatible)
Input P-1: +10dBm(fc≥90MHz),
0dBm(fc<90MHz)
DC Power: 3~3.6V/10~15mA Selection Guide:
Double tuned 0.1dB Chebyshev response DVT30-90 (30~90MHz), DVT30-110 (30~110MHz)
Tuning Speed ≤50us(fc>30MHz) DVT90-200(90~200MHz),
Up to 251 tuning step DVT200-400(200~400MHz)
Typical 2~3 octave band cover the frequency DVT400-700(400~700MHz) ,
band 30~1000MHz DVT550-865(550~865MHz)
SMT Package (non-hermetic) Note: Custom frequency bands availalbe
Operating Temperature Range:-40℃~+85℃

Specification Example:DVT30-90-5 means DVT30-90 series with


Electronical 5% 3dB bandwidth.
Parameter
3dB Bandwidth(%) 3~10%
%3dB Bandwidth flatness1) ≤1%
Insertion Loss at center frequency2) 2~6dB
IL variance3) ≤2dB
Shape factor (BW30/BW3) ≤7:1
Impedance 50Ω
Maximum VSWR 2.0:1max
Input P-1 +10dBm(TYP, fc≥90MHz)
0dBm(TYP, fc<90MHz)
DC Power(Vcc): +3.3V/15mA

Note: 1) difference of % 3dB bandwidth within the frequency band, see Page60-61 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method used to calculate
insertion loss:IL ×BW3dB%=20~25, For example % BW is 5% then IL is 4~5dB
3) See Page 60-61 for the typical curves

Enviromental Standard Special Standard Special


Vibration(5~2000Hz) 10G 20G Operating Temperature -40~+60℃ -40~+85℃
Shock(11 mSec) 30G 50G Storage Temperature -40~+100℃ -55~+125℃
Humidity 0~90% 95%

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


59
DVT30-90~DVT550-865digitally tuned filter
Sainty-Tech Communications Limited

Package Outline Pinout


DVT30-90~DVT550-865

Pin 1 2 3 4 5 6 7
Descrip Gnd A7 A6 A5 A4 A3 A2
Pin 8 9 10-13 14 15 16
Descrip A1 A0 N/C Vcc GND GND
Pin 17 18-28 29 30
Descrip RF GND RF GND
Vcc=+2.7~3.3V

DVT30-90~DVT550-865
Outline tolerance 0.5mm;

Orientation dot pin 1


Bottom
A0~A7 are 8 control bit lines. Tune words from 00000000 to 11111010 results in the tuned frequency from lowest to highest. The
binary tuning word is determined by the following relationship:
⎛ f desired − f low ⎞
Tuneword = ⎜ ⎟ ×250
⎜ f −f ⎟
⎝ high low ⎠

Example:If you wish to tune to 50MHz using a 30 to 90 MHz filter, the tune word is:
⎛ 50 − 30 ⎞ ×250=83D=53H
⎜ ⎟
⎝ 90 − 30 ⎠
Notes
1) The relationship between tuneword and frequency is only an approximate one.
2) Replacement alternative for MICRO-POLE series of POLE/ZERO
3) Zero DC resistance at both I/O port, additional DC blocking capacitance needed if necessary
4) RF input and output ports are interchangeable
5) Special frequency bands are available
Typical Plots

%3dB Bandwidth vs. Frequency Insertion Loss vs. Frequency


DVT30-90-5 DVT30-90-5
6.0 -2.0
Insertion Loss (dB)
3dB Bandwidth %

5.5 -2.5

5.0 -3.0

4.5 -3.5

4.0 -4.0
30 50 70 90 30 50 70 90
frequency(MHz) frequency(MHz)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


60
DVT30-90~DVT550-865digitally tuned filter
Sainty-Tech Communications Limited

%3dB Bandwidth vs. Frequency Insertion Loss vs. Frequency


DVT90-200-5 DVT90-200-5
5.5 -3.0

Insertion Loss (dB)


3dB Bandwidth %

5.0 -3.5

4.5 -4.0

4.0 -4.5

3.5 -5.0
90 120 150 180 200 90 120 150 180 200
frequency(MHz) frequency(MHz)

DVT200-400-4 DVT200-400-4
5.5 -2.5
3dB Bandwidth %

Insertion Loss(dB)
5.0 -3.0

4.5 -3.5

4.0 -4.0

3.5 -4.5
200 250 300 350 400 200 250 300 350 400
frequency(MHz) frequency(MHz)

P/N:DVT30-90-5 P/N:DVT30-90-5

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


61
DVT30-90~DVT550-865digitally tuned filter
Sainty-Tech Communications Limited

P/N:DVT200-400-4 P/N:DVT200-400-4

P/N:DVT400-700-4 P/N:DVT550-865-4

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

62
Multiband Digitally tunned LBM042A~LBM043A
Digitally tuned hopping filter
Hopping filter Frequency range:1.5~450MHz
Sainty-Tech Communications Limited

Features
Tuning control:10 bit parallel(TTL compatible) Selection Guide:
Cascaded 2 pole 0.1dB chebyshev response LBM042A:1.5~4MHz,4~10MHz,10~30MHz
Tuning speed ≤10us(fc>30MHz) LBM043A:30~90MHz,90~200MHz,201~450MHz
Full band covering:
Notes:1) 250 hopping steps in each single band for fc<90MHz,
LBM042A SW (1.5~30MHz)、
LBM043A USW(30~450MHz) 200 hopping steps for fc>90MHz;
I/O Impedance:50Ω 2) Customized frequency band available within 700MHz.
Package:SMA (F) or pins
Operating Temperature:-40℃~+85℃

Specification
Electronical
Parameter
Tuning Range 1.5~30MHz(LBM042A),
30~450MHz(LBM043A)
3dB Bandwidth(%) 3~10%
Fractional BW variance1) ≤1%
I.L at Center frequency2) 7~8dB
Shape Factor (BW30/BW3) ≤7:1
Impedance 50Ω
Maximum VSWR 2.0:1max
Input P-13) 30dBm(TYP, fc≥30MHz)
DC power4): +5V/270mA
Vbb:+15~100V/5mA

Note:
1) This is the difference of % 3dB bandwidth within the frequency band, see Page 56 for typical curves
2) Insertion loss at center frequency is typical one, the wider passband the lower IL. Following method
used to calculate insertion loss not including the switching loss:IL ×BW3dB%=20~25, For example % BW
is 5% then IL is 4~5dB , Loss of switch is about 3dB;
3) Decided by the bias voltage, refer to the “Input P-1-Bias voltage”typical curve on page 55
4) Current saving mode available, which can low the current down to 90mA

Environmental Standard Special

Vibration(5~2000Hz) --------------------------------------------------------------- 10G 20G

Shock(11 mSec) --------------------------------------------------------------- ----- 30G 50G

Relative Humidity------------------------------------------------------------------- 0~90% 0~90%

Operating Temperature--------------------------------------------------------–40~+60℃ –40~+85℃

Storage Temperature----------------------------------------------------------–40~+100℃  –55~+125℃

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com


63
LBM042A~LBM043A digitally tuned hopping filter
Sainty-Tech Communications Limited

Outline Drawing
16 12 4

6 ,5
119

PI N1 PI N15

119 ,5
115

M2 .5

(unit:mm)
Pinout
LBM042A~LBM043A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+5V GND A7 A6 A5 A4 A3 A2 A1 A0 N/C A8 A9 Vbb GND
Note: 1) A8~A9 are sub-band selection control bit lines. The words of Sub1, Sub2, Sub3 are 00B, 01B, 10B respectively. The
word 11B is for blocking
2) A0~A7 are 8 inband control bit lines. 0000000 control the lowest frequency FAH( < 90MHz) or C8H(>90MHz) control the
highest frequency
3) The binary tuning word is determined by both inband tuneword and frequency band selection word
⎛ f desired − f low ⎞
Tuning word in sub-band= ⎜ ⎟ ×( hopping step of subband)
⎜ f −f ⎟
⎝ high low ⎠

Example:If you wish to calculate the tune word of LBM043A at fc=100MHz,


⎛ 100 − 90 ⎞ ×200=18D=12H ,
Tuning word in sub-band = ⎜ ⎟
⎝ 200 − 90 ⎠
Band selection word is 01B
Then the full tuneword of A0~A9 at center frequency 100MHz is 49H
Application Note
Please refer to the application notes of LBM017A-85~LBM700A-85 series (Page55)

●TEL:+86-25-52635773 ●FAX: +86-25-52635773 ●http://www.sainty-tech.com ●E-mail: sales@sainty-tech.com

64

You might also like