CERTIFICATE OF CALIBRATION Issued By Transmille Ltd. Certificate Number 39334 Date of Issue 02 August 2019 Transmille Lid. Unit 4, Select Business Centre Page 1 of 2 Pages Lodge Road EINEM Staplchurst, Kent. TN12 00W. ‘www.transmille.com TEL 01580 890700 FAX 01580 890711 2 Approved Signatory IGA. Shapland COMA Bally — OSA Hawkins JJ. Baley Customer: PHOENIX CALIBRATION D.R., SRL MANZANAA SOLAR 3, ZONA FRANCA LOS ALCARNZOS STO, DGO| Date Received : 24 July 2018 Instrument: System 1D ‘TER104060 Job Number 72472-2 Deseription Thermocouple Adaptor Ref. Number ‘Manufacturer Transmille Site ‘Mode! Number THERM Location Serial Number 104060 Last Calibration Certificate: 34413 Procedure Version : 3.04/N Last Calibration Date 26/09/2017 Environmental Conditions Temperature: 20°C +/- 1°C Mains Voltage: © 230V +/-12V Relative Humidity -40% +/- 20% Mains Frequency : 50Hz +/- 1Hz Comments Instrument was allowed to stabilise for at least 12 hours before calibration Thermocouple voltages converted to temperature using BS tables. Reference temperature of 0'C used for the thermocouple CJC. Calibration information The instrument was calibrated against laboratory standards whose values are traceable to recognised National Standards. The uncertainty limits quoted refer to the measured values only, with no account being taken of the instruments ability to maintain its calibration. The reported expanded uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%. The uncertainty evaluation has been carried out in accordance with UKAS requirements, Calibrated By : J. 0. Bain Date of Calibration : 02 August 2019 ‘This centficat is issued in azcordance with the laboratory accrediation requirements ofthe United Kingdom Accreditation Service. It provides traceability of measurement to the SI system of units andlor to units of measurement realised atthe National Physieal Laboratory or other ‘recognised national metrology institutes. This certificate may not be reproduced her than in full except with the prior writen approval ofthe igsuing laboratory. | CERTIFICATE OF CALIBRATION | Certificate Number oe 38334 UKAS Accredited Calibration Laboratory No. 0324 ~ AAS FOUND RESULTS i ce Paige 2 612 Pages Test Title Applied Value Reading Uncertainties CJC Temp Correction _-20.00°C 20.00°C 20.12°C Temperature Output ~140°C Type K -4.6690mV -4.6687mV #1.5UV -50°C Type K -1.8890mV =1.8880mV 21.40 O°C Type kK 0.000 omv -0.0002mV #1.4uV 100°C Type K 4.095 OmV 4.094 7mV 214 200°C Type K 8.137 omVv 8.137 omVv +1.5uV 500°C Type K 20.640 Omv 20.640 OmV 21.5uV 700°C Type K 29.128 Omv 29.128 2mv 21.6uV 100°C Type K 41.269 OmV 41.269 amv 21.6uV 1250°C Type K 50.633 OmV 50.633 OmV 217 -180°C Type J -7.4020mVv -7.4015mVv +1.5uV 400°C Type J 21.846 OmV 21.845 7mV 21.5uV 750°C Type J 42.283 OmV 42.283 1mV 21.6uV -200°C Type T -6.6030mV -5.6027mV 21.5uV O°C Type T 0.000 omv -0.0002mVv 21.4 400°C Type T 20.869 omv 20.868 6mV 21.5uV -50°C Type R -0.2260mV -0.2260mVv 21.4uV 1700°C Type R 20.215 0mV 20.215 0mV #1.5uV -50°C Type S -0.2360mVv -0.2361mV #1.4uV 1700°C Type S 17.942 OmV 17.941 mV #1.5uV -270°C Type N -4.3452mV -4.3449mV t14uV 1900°C Type N 47.502 OmV 47.501 OmV #17uV 0°C Type 8 0.000 omv -0.0001mv 1.4uV 1800°C Type B 13.585 OmV 13.584 mV 4.5uV O°C Type E 0.000 omv -0.0002mVv #14 400°C Type E 28.943 OmV 28.943 1mv #1.6uV 800°C Type E 61.022mV 61.022mV 22.10 Thermocouple Reference Tables EN60584-1 : 1996 Equivalent to EN60584-1 : 1995 & IEC60584-1 : 1995 Replacing document BS4937 Parts 1-8 End of results

You might also like