Socomec DIRIS Brochure PDF
Socomec DIRIS Brochure PDF
NEW
 Applications
DIRIS A41
Ethernet
DIRIS A40 DIRIS A40 DIRIS A40
diris_744_a_1_cat
RS485
Main
PC meter panel
appli_384_b
diris_581_e_1_gb_cat
ÂÂ Front panel
1 2 3 4 5 6 7
Pulse outputs
ÂÂPlug-in modules
2 configurable pulse outputs (type, weight and run) on ± kWh, ±kvarh and kVAh
diris_445_a_1_cat
DIRIS® A40 RS485 link with JBUS / MODBUS® protocol (speed up to 38400 bauds).
PROFIBUS® DP communication
diris_775_a_1_cat
Ethernet communication
diris_777_a_1_cat
2 inputs - 2 outputs
diris_449_a_1_cat
- remote control,
- timed remote control.
Memory
diris_682_a_1_cat
Temperature
diris_747_a_2_cat
Temperature indication
• Internal
• External sensor PT 100 (T°C 1)
• External sensor PT 100 (T°C 2)
• External sensor PT 100 (T°C 3)
diris_720_a_2_cat
trafo_077_b_2_cat
trafo_024_a_2_cat
diris_718_b_1_cat
ÂÂTerminals
DIRIS A40
DIRIS A40
DIRIS A41
DIRIS A41
0V - + 1 2 3 4 5 6 7 8
1
diris_571_a_1_x_cat
diris_572_a_1_x_cat
diris_573_a_1_x_cat
0n + - + -
RS485 R = 120 0/4-20 mA 0/4-20 mA
OUT 1 OUT 2 OUT 1 OUT 2
DIRIS A40 / A41 DIRIS A40 / A41 DIRIS A40 / A41
RS485 link. 1 - 2: pulse output n°1. 5 - 6: analogue output n°1.
R = 120 Ω: internal resistance for the 3 - 4: pulse output n°2. 7 - 8: analogue output n°2.
RS485 link.
9 10 11 12 17 18 19 20 21 22 23 24 25 26
diris_683_a_1_x_cat
+ - sensor 1 sensor 2
OUT 1 OUT 2
diris_753_a_1_gb_cat
IN
A-Cd A-Cd
synchro 27 28 29 30
1 3 14 15 16 DIRIS A40 / A41 sensor 3
diris_574_b_1_x_cat
- + - + DIRIS A40/A41
17 - 18: synchronisation input.
IN 1 IN 2 Sensor 1 Sensor 2 Sensor 3
DIRIS A40 / A41 19: Red 23: Red 27: Red
9 - 10: relay output n°1. 20: Red 24: Red 28: Red
11 - 12: relay output n°2. 21: White 25: White 29: White
13 - 14: opto input n°1. 22: White 26: White 30: White
15 - 16: opto input n°2.
Ethernet Module Ethernet module + RS485 JBUS /
MODBUS gateway
10 BASE T 10 BASE T 0V - +
diris_751_b_1_gb_cat
diris_752_a_1_x_cat
ÂÂElectrical characteristics
Current measurement on insulated inputs (TRMS) 2 inputs / 2 outputs module: Outputs (alarms / control)
Via CT primary 10 000 A Number of relays 2(1)
Via CT secondary 1 or 5 A Type 250 VAC - 5 A - 1150 VA
Measurement range 0 … 11 kA
Input consumption ≤ 0.1 VA 2 inputs / 2 outputs module: Phototransistor inputs
Measurement updating period 1s Number 2(1)
Accuracy 0.2 % Power supply 10 … 30 VDC
Sustained overload 6A Minimal signal width 10 ms
intermittent overload 10 In for 1 s Minimum length between 2 impulses 18 ms
Type phototransistor
Voltage measurements (TRMS)
Direct measurement between phases 50 … 700 VAC Pulse outputs module
Direct measurement between phase and neutral 28 … 404 VAC Number of relays 2
VT primary 500 000 VAC Type 100 VDC - 0.5 A - 10 VA
VT secondary 60, 100, 110, 173, 190 VAC Max. number of operations ≤ 108
Frequency 50 / 60 Hz
Analogue output module
Input consumption ≤ 0.1 VA
Number of outputs 2(2)
Measurement updating period 1s
Type insulated
Accuracy 0.2 %
Scale 0 / 4 … 20 mA
Sustained overload 760 VAC
Load resistance 600 Ω
Current-voltage product Maximum current 30 mA
Limitation for 1A CT 10 000 000
JBUS / MODBUS communication module
Limitation for 5A CT 10 000 000
Link RS485
Power measurement Type 2 … 3 half duplex wires
Measurement updating period 1s Protocol JBUS/MODBUS® in RTU mode
Accuracy 0.5 % JBUS/MODBUS speed
®
1400 … 38400 bauds
ÂÂ Case
+ 0.8 Type Panel mounting
92 - 0.0
Dimensions W x H x D 96 x 96 x 60 mm
Case protection index IP30
Front protection rating IP52
Display type LCD
Terminal blocks type fixed or pull-out
Voltage and other connection section 0.2 … 2.5 mm2
Current connection section 0.5 … 6 mm2
Weight 400 g
96 DIR
IS
A4
0 92
+ 0.8
- 0.0
35
diris_582_d_1_x_cat
60
96
Recommendation: when disconnecting the DIRIS, the secondaries of each current transformer must be short-circuited. This operation can be carried out automatically by a product in
the SOCOMEC catalogue, PTI: consult us.
In TNC neutral system it is recommanded to use functional earth module.
1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class 1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class 1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class
N P1 P1
P1 L1 L1
L1 S1 S2 S1 S2
S1 S2 N L2
L2
L3
1 1 1 1 1 1
diris_392_d_1_gb_cat
diris_393_d_1_gb_cat
diris_394_d_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
3/4 wires with 3 CTs 3 wires with 2 CTs 3 wires with 2 CTs
1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class 1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class
1 = Fus. 0.5 A gG / BS88 2 A gG / 0.5 A CC Class P1
N P1 L1 L1
P1 S1 P1
L1 S1 S2 L2 L2
S1 S2 S1 S2
L2 P1 L3 L3
P1 L3 S1 S2
S1 S2
1 1 1 1 1 1
1 1 1
diris_395_d_1_gb_cat
diris_396_d_1_gb_cat
diris_397_d_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2 V1 V2 V3 VN S1 S2 S1 S2 S1 S2
I1 I2 I3 I1 I2 I3 I1 I2 I3
Use of 2 CTs reduces by 0.5% the accuracy of Use of 2 CTs reduces by 0.5% the accuracy of
the phase, whose current is worked out by vector the phase, whose current is worked out by vector
calculation. calculation.
1 1 1
diris_575_b_1_gb_cat
V1 V2 V3 VN S1 S2 S1 S2 S1 S2 S1 S2
I1 I2 I3 IN
Additional information
Communication via RS485 link Voltage transformer for HV networks AC & DC auxiliary power supply
L1
L2 110 / 400 VAC (IEC)
L3 120 / 350 VDC (IEC)
LIYCY-CY
diris_400_g_1_gb_cat
diris_399_b_1_x_cat
diris_398_c_1_x_cat
0V - + A U X
ON V1 V2 V3 N
RS485
It is recommended that the auxiliary power supply be
protected by the use of 500 mA gG fuses.
 References
diris_744_a_1_cat
DIRIS A41
with CT on the
Basic device DIRIS A40 neutral
Auxiliary power supply Us Reference Reference
110 ... 400 VAC / 120 ... 350 VDC 4825 0201 4825 0202
12 ... 48 VDC 4825 1201 4825 1202
Options
Accessories
To be ordered To be ordered
Description of accessories in multiples of Reference in multiples of Reference
IP65 protection 1 4825 0089 1 4825 0089
Panel mounting kit for a 144 x 96 mm cutout 1 4825 0088 1 4825 0088
Fuse combination switches for the protection of voltage inputs (type RM) 3 poles 4 5601 0018 4 5601 0018
Fuse combination switches for the protection of the auxiliary supply (type RM) 1 pole + neutral 6 5601 0017 6 5601 0017
Fuses type gG 10x38 0.5 A 10 6012 0000 10 6012 0000
Current transformers range See page 334 See page 334
(1) Ease of integration for additional functions (maximum 4 on A40 and 3 on A41).
 Ethernet Webserver
Instantaneous report of measurements Power and Energy
diris_867_a_1_gb_cat
diris_776_a_1_cat
diris_869_a_1_gb_cat
Panels for viewing all average and instantaneous electrical Viewing of average and instantaneous energy consumptions.
values.
The last 10 alarms are date and time registered. Duration and limit reached
(low limit value / high limit value), as well as the related output alarm number
are also displayed. Data can be extracted in *.csv format.