You are on page 1of 1

ONE-WAY SLAB DESIGN

(1/24) (1/10) (1/11) (1/11) (1/11) (1/11) (1/11)

(1/16) (1/16) (1/16)

2.60 m 2.60 m 2.60 m

DESIGN DETAILS:
Main bar, fy = 276
Diameter = 16
Secondary bar, fy = 276
Diameter = 12
fc'= 28
DL = 9.8816
LL = 4.8

SLAB THICKNESS COMPUTATION


Beam = 450
Stringer = 300
Spacing= 2.6

Interior span (L/28)


Ln = 2225
Min h = 63.117346939

Exterior span (L/24)


Ln = 2225
Min h = 73.636904762
Use h = 100

TEMPERATURE BAR SPACING


Smax 1 = 450 450
Smax 2 = 5h 500
Smax 1 = Ab/pgh 1117.010721
Sgovern = Min[ Smax 1-3] 450

Main Bar Spacing


wd = 12.2816 Smax 1 = 450 450
wu = 22.41792 Smax 2 = 3h 300
pmin = 0.0050724638 pg 0.0018
conc cover = 40 Smax 3 = Ab/pgh 1117.011
m = 11.596638655 Sgovern = Min[ Smax 1-3] 300
d= 52

Moments
Negative Positive Negative
(Exterior) (Interior) (Interior)
Coefficient = 1/24 1/14 1/10
Ln (m) = 2.225 2.225 2.225
Mu (KN) = 4.6242798 7.9273368 11.09827
X = 0.0068847128 0.011802365 0.016523
Preq = 0.0071839598 0.012744079 0.01851
4/3p = 0.0095786131 0.016992105 0.02468
use p = 0.0071839598 0.012744079 0.01851
Sreq'd = 538.22343997 303.4017338 208.8922
Smax = 300 300 300
Suse = 300 300 208.8922
Say = 300 300 200

You might also like