Automatic Bin

Switching
COMMANDbatch V1.7.5.0 & Later
4/8/13

Command Alkon Inc.


5168 Blazer Parkway
Dublin, Ohio 43017
1.800.624.1872
Fax: 614.793.0608
Part Number: 24999
© 2003-2013 Command Alkon Incorporated. All rights reserved.
Command Alkon Incorporated believes the statements contained herein are accurate as
of the date of publication of this document. HOWEVER, COMMAND ALKON
INCORPORATED HEREBY DISCLAIMS ALL WARRANTIES EITHER EXPRESSED OR IMPLIED,
INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANT OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE. In no event will Command Alkon Incorporated be
liable for any damages, including any lost profits, lost savings, or other incidental or
consequential damage arising out of the use of or inability to use any information
provided through this publication, even if Command Alkon Incorporated has been advised
of the possibility of such damages, or for any claim by any other party. Some states do
not allow the limitation or exclusion of liability or consequential damages, so the above
limitation may not apply.
This information is not intended to be an assertion of future action. The contents of this
document are for informational purposes only and are subject to change without notice.
Command Alkon Incorporated expressly reserves the right to change or withdraw current
products that may or may not have the same characteristics listed in this publication.
Should Command Alkon Incorporated modify its products in a way that may affect the
information contained in this publication, Command Alkon Incorporated assumes no
obligation whatever to inform any user of the modification.
This publication may contain technical inaccuracies or typographical errors. Command
Alkon Incorporated assumes no responsibility for any errors that may appear in this
manual. This publication is intended only for the direct benefit of users of Command
Alkon Incorporated products. This manual may not be used for any purposes other than
those for which it is provided. Information disclosed herein was originated by and is the
property of Command Alkon Incorporated, and, except for rights granted by written
consent, such information shall not be disclosed, disseminated, or duplicated in whole or
in part. Command Alkon Incorporated reserves all patent, proprietary, design,
manufacturing, use, and reproduction rights.
www.commandalkon.com
Command Alkon Incorporated
1800 International Park Drive, Suite 400
Birmingham, AL 35243-4232
(205) 879-3282
5168 Blazer Parkway
Dublin, OH 43017-1339
(614) 799-6650
For a list of all Command Alkon locations, go to:
http://www.commandalkon.com/locations.asp
COMMANDseries (and the names of its components, such as COMMANDconcrete and
COMMANDnetwork), Spectrum, Eagle, and COMMANDbatch are registered trademarks of
Command Alkon Incorporated. All rights reserved.
Windows is a registered trademark of Microsoft Corporation in the United States and
other countries.
Hydro-Control is a registered trademark of Hydronix Limited, United Kingdom.
Verifi is a registered trademark of RS Solutions, Cincinnati, Ohio, USA.

2 4/8/13
Contents

Contents ........................................................................................ 3

Introduction .................................................................................. 4
Purpose ................................................................................................ 4
Audience ............................................................................................... 4
Revision Summary ................................................................................. 4

Automatic Bin Switching ................................................................ 5


Setting Up Auto Bin Switching .................................................................. 5
Operation of Auto Bin Switching ............................................................... 6

4/8/13 3
Introduction

Topics in This Section


Purpose
Audience
Revision Summary

Purpose
This document explains how to configure the system to automatically select
an alternate feed source without operator intervention when a feed timeout
occurs.

Audience
This guide is intended to be used by Command Alkon installation and service
personnel, as well as plant personnel specifically authorized to install and
configure COMMANDbatch.

Revision Summary

CMDbatch
Date Version Revision
Mar. 8, 2005 1.03 Document created.
Mar. 17, 2005 1.03 Final draft released for COMMANDbatch V1.03.
Mar. 8, 2007 1.06 Improved Notes, Tips, Cautions, and Warnings with
better icons and formatting.
Sept. 4, 2007 1.06 Formatting changes.
Oct. 14, 2008 Corrected this revision summary.
Nov. 18, 2008 1.7.5.0 Added a note about auto bin switching when two
bins are active.
Apr. 8, 2013 1.8.5.4 Added scale/metered feed setups to this document.

4 4/8/13
Automatic Bin Switching

When Auto Bin Switching is enabled and a feed timeout occurs, the system
checks for an alternate source for the material. If an alternate source is
available, the remaining required material is fed from the alternate bin. Auto
Bin Switching can be set up so that no operator intervention is needed.

Note: In a 2-bin setup where both bins are active, Auto Bin Switching
allows feeding to switch to the second (or Fast Feed) bin if the
primary bin runs out of material.

Topics
Setting Up Auto Bin Switching
Operation of Auto Bin Switching

Setting Up Auto Bin Switching


1. On the Batching tab of the Plants form, check the “Allow Auto Bin
Switch” and “Bin Switch Automatic” boxes.
2. It is recommended that the “Bin Switch Permanent” box also be
checked so that the secondary bin becomes the primary bin after
bin switching has occurred.
Plants form - Alt Bin setup

3. Save your changes.


4. On the Flow tab of the Scales and Metered Feeds forms for the
appropriate scales/meters:

4/8/13 5
— (Scales): Enter a “Switch to Alt. Bin Below” flow rate and an “After
Delay” time.
— (Metered Feeds): Enter a “Switch to Alt. Source Below” flow rate
and an “After Delay” time.

Note: When the flow rate falls below the “Switch to Alt. Bin/Source
Below” rate for the number of seconds entered in the “After Delay”
field, the system switches to the alternate bin/source.

Scales form - Alt Bin setup

5. Save your changes.

Operation of Auto Bin Switching


When a feed timeout occurs, the system checks for an alternate source for the
material. If an alternate source is available, the remaining required material is
fed from the alternate bin. This happens without operator intervention.
However, if a feed timeout occurs and there are no remaining alternate feed
sources, the following message appears so that the operator can take action
the same way he would for manual bin switching.
No Alternate Bin Notification

Note: In a 2-bin setup where both bins are active, Auto Bin Switching
allows feeding to switch to the second (or Fast Feed) bin if the
primary bin runs out of material.