FEATURES
• 150 psi to 20000 psi range
• Flush mount design
• High frequency
• No internal dead volume
• mV/V output
• Subminiature footprint
• 1 % accuracy
• CE approved
Model G
Characteristic Measure
Strained gage type Bonded foil
Excitation (calibration) 5 Vdc OPTION CODES
Bridge resistance 350 ohm Range Code Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
Shunt calibration data Included grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Electrical termination (std) Four twisted leads (1.83 m [5 ft]) with
external balance board 150, 200, 250, 300, 400, 500, 600, 750, 1000,
Pressure ranges 1500, 2000, 2500, 3000, 4000, 5000, 6000,
7500, 10000, 15000, 20000 psig
1a. 60 °F to 160 °F
MECHANICAL SPECIFICATIONS 1f. 70 °F to 250 °F
1b. 30 °F to 130 °F
Temperature 1g. 70 °F to 325 °F
Characteristic Measure 1c. 0 °F to 185 °F
compensation 1h. 70 °F to 400 °F
1d. -20 °F to 130 °F
Media Gases, liquids compatible with wetted 1i. -65 °F to 250 °F
1e. -20 °F to 200 °F
material
Internal
Overload, safe 50 % over capacity 2u. Unamp., mV/V output
amplifiers
Wetted parts material 17-4 PH stainless steel
Electrical Four twisted leads 1.83 m [5 ft]
Case material Stainless steel termination 6d. Microtec DR-4S-4H 4-pin (max 250 °F)2
WIRING CODES
Wire Cable/unamplified
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output
For reference only Transducers have a small electrical balance circuit board
(approximately 1.0 in long by 0.38 in wide) located in the lead
wire that is two feet from the transducer body.
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for
reference only. DO NOT USE this document as product
installation information.
• Complete installation, operation and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.