Revision and Errata List

AISC Steel Design Guide 16, 1st Printing


April 12, 2010

The following list represents corrections to the first printing of the AISC Design Guide 16, Flush and
Extended Multiple-Row Moment End-Plate Connections.

Page(s) Item

11 In the left column, Equation 2-11 should read:


2
wt p 2  F 
Qmax,i  Fpy2  3 i 
4ai  wt p 
 

11 In the left column, Equation 2-13 should read:


3
 tp 
ai  3.682    0.085
 db 

11 In the right column, Equation 2-16 should read:


3
 tp 
3.682    0.085
ao   db 
Pext  Pf ,o
min

41 In the left column, section “4.2.2 Four-Bolt Extended Unstiffened Moment End-Plate
Connection (Table 4-3)” should be replaced with “4.2.2 Four-Bolt Extended Stiffened
Moment End-Plate Connection (Table 4-3).”

47 In the right column under Design Procedure 1, the equation “db = 7/8 in.” should be
replaced with “db = 5/8in.”