ACIH® Industrial Hospital Compressed Air Systems

ACIH Systems Regulation Reliable Construction


The ACIH industrial hospital The ACIH industrial hospital The ACIH systems are equipped with
compressed air systems were compressed air systems comply with the most up-to-date technology in
developed to meet the needs the Machinery Directive and the ACSS rotary screw compressors produced
imposed by hospital standards that ET 08/2010 technical specifications. by Gardner Denver in its plant in
prohibit the use of medicinal air for The ACIH systems resemble the Siemmern, Germany.
industrial purposes, requiring the requirements of standard ISO 7396-1 The ACIH integrates, in its whole, air
existence of an independent pertaining to redundancy, the treatment systems that ensure the
supply with features that are command, control and alarm systems continuous supply of excellent quality
appropriate to the equipment in order to ensure a continuous supply air without loss of their filtration
installed in hospital buildings. The of air to the various pneumatic systems capacity over 6,000 to 10,000 hours
design of ACIH systems is the including the supply of the autoclaves of continuous service, thanks to the
result of our experience of more for sterilization. filtering means free from binding
than 30 years related to compressed The design, production and assembly agents and the construction of their
air and associated with leading of the ACIH air systems follow the mechanical structure with stainless
global brands. standards defined by the Quality steel mesh.
Management System, ISO 9001:2008. We emphasize the importance of our
built-in filtration systems that are
properly sized to allow for very low
pressure drops which represent huge
energy savings over the years of use.
Basic configuration Compressors Electric switchboard
Rotary screw compressors equipped with ● Analogical control
● 1, 2, 3 or more air compressors
high efficiency motors, suction air filter for ● Digital control
● 1, 2, 3 compressed air treatment
dust protection, oil filter, high efficiency oil ● QuAir with digital console and
and drying units with an electronic
separator, air/oil and air/air heat communication with a PC
condensate drain, zero-loss
exchangers, cyclone separator and digital
● 1 electric control box
control panel with information on inlet
● 1, 2 or more compressed air tanks Automatic oil/water separator
pressure and network pressure, alarms
● 1 or 2 sets of pressure reducers
and alerts for preventive maintenance. The MEDIAR system comes equipped
including sterile filter, ball valves with a condensate treatment unit which
and manometer Tanks removes the oil, thereby allowing the
● 1 oil/water separator for ● Vertical configuration draining of condensates into the sanitary
condensate treatment ● Capacities of 100 to 3,000 litres network.
● 1 set of safety valves and safety ● Hot-dip galvanized internal and external The system includes a test valve to
devices for the good working and treatment collect and analyse a sample of
extended life of the equipment ● Epoxy external finish condensates before being introduced into
● Including safety accessories: the sanitary system.
Note: The configuration does not - safety valve, calibrated manometer
include the power switchboard for the
direct electrical supply to the - Manual bleeding valve Technical data
compressors and respective cables. ● Connection for complementary ● Normal service pressure: 8-10 bar or
Normally the supply comes directly from emergency groups 10-12 bar
3
a partial switchboard or a general ● Electronic condensate drains ● Normal capacities*: 15 to 720 m /h
switchboard from the customer plants. ● Power*: 2.2 to 110 kW, 400V, 50Hz
* Capacity and power per compressor
● Other capacities, pressures and
versions available as standard.

Central de Ar Comprimido Industrial Hospitalar ACIH 3.____/____D


ACIH with oil-free compressors
Upon request, the industrial hospital
Comp 3
compressed-air systems, ACIH, can
be built from totally oil-free
compressors to meet the most
Ft 1 Uta2 Ft 2
stringent requests of 100% oil-free air
Comp 2 Res 2
quality.
Válv. Rede

Comp 1 Res 1
Ft 1 Uta 1 Ft 2 ACIH also built considering
the preservation of nature
Composição:
3 compressores
Q.E. A 2 reservatórios

B
2 secadores de ar
2 filtros micrónicos
2 filtros submicronicos
All systems are designed to minimize
Sep condensados 1 quadro de comando
1 separador óleo/água
operating costs - less energy and
ACIH 3__/__D - 09-2011-SV
parts - saving the environment.

Typical ACIH diagram with 3 compressors + 2 tanks + 2 treatment units


Other configurations available: E.g.: 3 compressors + 3 tanks + 3 treatment units
Safe and Simple Assembly Preventive Maintenance
The system is pre-assembled. Only the The maintenance of the ACIH
connection of the compressors to the compressed air system is carried out
tanks; from the tanks to the treatment regularly by technicians who are certified
unit modules connection to the air by Ultra-Controlo so as to ensure that the
network are needed. system is always in its initial conditions of
It can include all connection cables and use.
flexible hoses and drainage kit with all Behind each ACIH, there is a team of
pipes and pneumatic tubes and competent professionals who are trained
accessories. by the manufacturers of the main
The ACIH is adjusted and tested at the components to take care of the equipment
factory and is ready to be installed at and ensure its correct maintenance.
any given location. With a reduced number of parts used and
In medium and large systems, the pre- which are easy to access, maintenance
installation, the initial start-up and the has never been so simple and economic. With the Gardner Denver screw
training of staff is supervised by our compressors, preventive maintenance
skilled technicians. is carried out in the blink of an eye,
saving on service and parts!
Proven quality, year after year
► Gardner Denver compressors are in the hospital field for decades, all over the world!
► Hundreds of compressors installed in Portugal, working 24h/7 days a week.
► ACIH compressors air-end has 2 years guarantee and can be extended for 5 years!
► Service Centre for hospital air systems compressors, certified under ISO 9001:2008 and ISO 13485:2003
Compressor Compressor
flow Motor power flow Motor power
Model Tank Model Tank
m3/h kW m3/h kW
ACIH litres ACIH litres
10bar 400V/50Hz 13bar 400V/50Hz

3.15/500D 3x14,4 3x2,2 2x500 3.50/800D 3x51 3x7,5 2x800


3.20/500D 3x21,6 3x3,0 2x500
3.80/1000D 3x79,2 3x11 2x1000
3.30/500D 3x31,8 3x4,0 2x500
3.40/800D 3x40,8 3x5,5 2x800 3.110/1000D 3x108 3x15 2x1000
3.60/800D 3x63,6 3x7,5 2x800
3.140/1000D 3x140,4 3x18,5 2x1000
3.100/1000D 3x96,1 3x11 2x1000
3.130/1000D 3x135,6 3x15 2x1000 3.160/1000D 3x156,6 3x22 2x1000
3.170/1000D 3x164,4 3x18,5 2x1000 3.260/1500D 3x262,8 3x30 2x1500
3.200/1000D 3x192,6 3x22 2x1000
3.320/1500D 3x319,2 3x37 2x1500
3.300/1500D 3x301,7 3x30 2x1500
3.370/1500D 3x371,4 3x37 2x1500 3.360/2000D 3x367,8 3x45 2x2000
3.420/2000D 3x421,2 3x45 2x2000
3.500/2000D 3x496,2 3x55 2x2000
3.450/2000D 3x445,2 3x45 2x2000
3.600/2000D 3x572,4 3x55 2x2000 3.630/2000T 3x630,6 3x75 3x2000

3.750/2000T 3x748,8 3x75 3x2000


Authorized
We design and build ACIH industrial hospital compressed air systems Distributor
according to your needs. For details consult our Engineering department.

Note: This brochures contain author reights and so is prohibited any extraction of its content, images or photographs. We reserve the right to change it without previous
notice

Ultra-Controlo - Projectos
Industriais, Lda. Tel: +351-219154355
Parque Industrial Quinta Lavi, Armz 8 Fax: +351-219259002
Abrunheira Email: international@ultra-controlo.com
2710-089 Sintra - PORTUGAL Web: www.ultracontrolo.com.pt

ACIH_rev.2_20092011

You might also like