Job Job no

Part of structure Calc sheet


no
Dwg ref Calculations by Checked by Date

MEMBER CALCULATIONS
S REF

5PC2 5 - Pile Group


Pile : f 500mm Bored Pile
Min. Column Size : Xmin = 250mm Ymin = 250mm

Xmin
Y
A

Column a
av Depth = 1,500 mm

a = 450 mm
2b 0

X X
L
Y min

b0 = 1,061 mm

L = 3,022 mm
b0

Spun Pile b0 A
a 2b0 Y a
L

LOADING

Pile capacity = 1,730 kN

Ultimate load per pile = 1.5 x 1,730 = 2,595 kN

BENDING

Taking bending moment to the face of the column and allowing 75 mm pile ecc.

Mult = 2 x 2,595 x ( b0 - Xmin/ 2 + 75 ) x 10


-3
= 5,248 kNm

b = 3,022 mm , d = 1,500 - 100 - 25 x 1.5 = 1,363 mm


Mult / bd2 = 0.94 , As req'd = 0.25% bd = 10,294 mm2
As min = 0.13% bh = 5,893 mm2
Provide 25 T 25 ( B ) As prov'd = 12,272 mm2
Job Job no

Part of structure Calc sheet


no
Dwg ref Calculations by Checked by Date

MEMBER CALCULATIONS
S REF

5PC2

SHEAR

( a ) ) At Section A - A

Vult = 2 x 2,595 = 5,190 kN, v = Vult / bd = 1.26 N /mm2

As prov'd = 12,272 mm2, 100As / bd = 0.30

vc = [ 0.79 x (100As/bd)1/3 / 1.25 ] x (35/25)1/3 = 0.47 N /mm2

av = ( b0 ) - ( Xmin / 2 ) - ( 0.5 - 0.2 ) x 500 + 75 = 861 mm

Enhanced shear strength = ( 2d /av ) vc = 1.49 N / mm2 > 1.26 N / mm2

Asv req'd = 861 x 3,022 x ( 1.26 - 1.49 ) / ( 0.87x 460 ) = 2,601 mm2 for the
strip between Section A - A and the adjacent column face. [ Cl. 3.4.5.9 of BS 8110 : Part 1 ]

2 rows of T16 8 - leg shear links ( Asv = 3,217 mm2 )


will do this.

Provide T16 - 400 Bothways shear links.


Asv/sv pro 4.02 .

( b ) Check on Punching Shear

Maximum ultimate column load = 5 x 2,595 = 12,975 kN

For column, assuming that fcu = 45 N / mm2, fy = 460 N / mm2 and Asc prov'd = 6% of
cross-sectional area of the column,

Minimum cross-sectional area of column required for resisting the above column load

= 12,975 x 103 / [ 0.35 x 45 x ( 1 - 6% ) + 0.67 x 460 x 6% ] = 389,675 mm2

Minimum column perimeter = ( 389,675 )1/2 x 4 = 2,497 mm

Punching shear around column perimeter = 12,975 x103 / ( 2,497 x 1,363 )


= 3.81 N /mm2

For pile cap, fcu = 35 N /mm2, 0.8(fcu)1/2 = 4.73N/mm2 > 3.81 N /mm2

O.K.
Job Job no

Part of structure Calc sheet


no
Dwg ref Calculations by Checked by Date

MEMBER CALCULATIONS
S REF

5PC2

REINFORCEMENT DETAILS Nominal reinft. Req'd


= 0.13% x 1,000 x 1,500
T16 - 100 T1 = 1,950 mm2 / m
25 T25 B1 Provide T16 - 100 ( Top )
H2 H1

6 T16 ( H1 )
Lacer Bars 6 T16 ( H2 ) Lacer Bars

T16 - 100 T2

25 T25 B2
1 1

H24 H1

Column starter bars

T16 - 100

T16 - 100
T16 - 400 links (B/W)
Depth

H2
H1

25 T25
100

25 T25

1 - 1