MEMBER CALCULATIONS
S REF
Xmin
Y
A
Column a
av Depth = 1,500 mm
a = 450 mm
2b 0
X X
L
Y min
b0 = 1,061 mm
L = 3,022 mm
b0
Spun Pile b0 A
a 2b0 Y a
L
LOADING
BENDING
Taking bending moment to the face of the column and allowing 75 mm pile ecc.
MEMBER CALCULATIONS
S REF
5PC2
SHEAR
( a ) ) At Section A - A
Asv req'd = 861 x 3,022 x ( 1.26 - 1.49 ) / ( 0.87x 460 ) = 2,601 mm2 for the
strip between Section A - A and the adjacent column face. [ Cl. 3.4.5.9 of BS 8110 : Part 1 ]
For column, assuming that fcu = 45 N / mm2, fy = 460 N / mm2 and Asc prov'd = 6% of
cross-sectional area of the column,
Minimum cross-sectional area of column required for resisting the above column load
For pile cap, fcu = 35 N /mm2, 0.8(fcu)1/2 = 4.73N/mm2 > 3.81 N /mm2
O.K.
Job Job no
MEMBER CALCULATIONS
S REF
5PC2
6 T16 ( H1 )
Lacer Bars 6 T16 ( H2 ) Lacer Bars
T16 - 100 T2
25 T25 B2
1 1
H24 H1
T16 - 100
T16 - 100
T16 - 400 links (B/W)
Depth
H2
H1
25 T25
100
25 T25
1 - 1