RECTIFICATION PROPOSED ‘Method Defect Description Rectification Tevel difference, Targe crack on retaining wall/ side wall of ramp/ ‘parapet wall; separation between ‘paving & drain; kerb cracked & settled Replace the affected portion of the elements after consolidating the ground Replace the affected area of premix after consolidating the 2 | Crack on the premix sone Map! plaster eracks on the 3 | wallsurface finish worn offf Hack & replace the plaster! surface finish surface finish chipped off 4 | cackins concrete Inject the crack with a low viscosity epoxy resin, Monitor in vuctural future for reappearance ‘Corrosion & pitting on side Face of 5 | beam/ Corrosion on anchor boll | Remove rust stains & apply anti-corrosion paint ‘Corrosion on weld joint at beam «6 _| Separation crack between Hack the plaster and provide wire mesh at the interface of structural member & wall concrete & masonry and re plaster the surface Map cracks; delamination of 7 | Sifcetinish on paving: foor | Hack & repair with polymer mfed mora! no shrink finish Crack on wallfvertical crack | ®" Place the conere " ‘Cracking and delamination on —_| Haack & repair with polymer modified mortar or non.shrink 8 | railing kerb/ railing anchorage’ grout afer treating the corroded anchorage! anchor plate! ‘russ anchorage anchor bolts ‘Crack’ separation? damagel 9 | watermarks/ paint peeling on false | Block the source of leakage. Replace the false ceiling panel ceiling Delamination of surface finish or 10 | taster on ker wall’ Noor Hack & replace the affected surface finish area 11 | Paiat peeling off on coluran Remove loose paint & apply a waterproof protective supporting cantilever Awning | coating 12 | Map ctacks with watermarks & | Grou seal the crack with a low viscosity flexible epoxy. efflorescence on RC slab soffit | Prevent ingress of water from top 13 | Crack on floor tiles Replace the floor tiles ‘Watermarks; water seepage: sins | APPLY waterproof prowetve coating onthe wall afer 14 | & paint popping up on wall/slab a = solfit 15 Delamination & cracking of plaster ‘on the wall at the interface of waterproofing membrane & plaster Hack & replace the waterproofing membrane & plaster at the interface Method Defect Description Rectification Level difference between side wall of driveway & kerb/ Crack Fill the cracW’ gap with non-shrink grout and raise the level 16 between kerb & side wall of driveway ‘with non-shrink grout or concrete topping, if required 0 Settlement at ground near BBQ pit platform 1 Fill the gap with soil and consolidate 18 Plaster popping up/ spalling on the slab soffit Hack & repair with polymer modified mortar or non-shrink ‘grout after treating corrosion in rebars, if any 19 Heavy corrosion with loss of metal ‘Remove the rust stains and apply anti-corrosion paint, Replace the member if loss of sectional area >20%. 20 Deflection of lamp posts besides Remove the lamp posts and consolidate the base. Re-fix the parapet/ retaining wall lamp posts upon consolidating and levelling the ground (Cracking and delamination of filler 21 | all under BBO pat Replace the filler wall afer consolidating the ground Mild to Heavy corrosion on steel 22 frames! corrosion with loss of ‘Strengthen / replace the heavily corroded frame members staircase members

You might also like