You are on page 1of 1

The motor lead extension(MLE) is used to link the power cable and the motor.

We have different
temperature grade,120℃,204 ℃, 232℃, 250℃. We provide galvanized steel armor, stainless steel
armor or monel armor for corrosive medium.
The MLE pothead is a key part to connect the motor with the power cable. The pothead types include 114,
116, 138, and are compatible with Reda 375, 456, 540, 562 and centrilift series.

Conductor Cross
Rated Voltage
Model (AWG) Section Number /Diameter Temperature
(kV)
(mm2) n/D (℃)

4# 20 1/5.19

5# 16 1/4.62
QYJYEQ
6# 13 1/4.12 120

7# 10 1/3.6 204 3

4# 20 1/5.19
232 6

5# 16 1/4.62
QYJYFQX 250

6# 13 1/4.12

7# 10 1/3.6

Note:
QYJYEQ--Polyimide compound film sintering/EPR compound insulated lead sheathed, galvanizing steel
armored with interlock ESP flat motor lead extension cable.

QYJYFQX--Polyimide F46 compound film sintering/ F46 compound insulated lead sheathed stainless
steel armored with interlock ESP flat motor lead extension cable.