CATALOGUE
HEAT PUMP & HEAT RECOVERY
ISO 9001 ISO 14001 ISO 9001 ISO 14001 ISO 9001 ISO 14001
Certified number: 01 100 89394 Certified number: 01 104 9245/01 Certified number: 01 100 79269 Certified number: CNBJ311153-UK Certified number: 15914Q10065R4M Certified number: 15912E10022R3M
Fujitsu General (Thailand) Co., Ltd. Fujitsu General (Shanghai) Co., Ltd. Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas.
• Specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorised dealer.
• iPhone and iPad are trademarks of Apple Inc., registered in the U.S. and other countries.
• Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.
• Actual products’ colors may be different from the colors shown in this printed material.
Distributed by :
Heat Recovery Modular type Heat Pump Modular type Heat Pump type Heat Pump type Heat Pump type
for simultaneous heating and cooling operation for heating or cooling operation for heating or cooling operation for heating or cooling operation for heating or cooling operation VENTILATION
DX-Kit for air handling applications ............................ 132
AIRSTAGETM OPTION
Auto Louver Grille Kit .................................................. 135
8 HP - 48 HP 34 Models 8 HP - 54 HP 39 Models 8 HP - 12 HP 3 Models 4 HP - 6 HP 6 Models 4 HP - 6 HP 3 Models
• Space saving combination: 8 HP to 48 HP/21 models • Space saving combination: 8 HP to 54 HP/24 models • 3 phase • Single phase, 3 phase • Single phase OPTIONAL PARTS LIST ................................................. 136
• Energy efficiency combination: 16 HP to 44 HP/13 models • Energy efficiency combination: 16 HP to 46 HP/15 models OPTIONAL PARTS ....................................................... 138
2 3
OUR SOLUTION FOR ALL PROPERTIES
Fujitsu General provides the best solutions suitable for properties.
4 5
NEW PRODUCTS
Centralized Control
Touch Panel Controller System Controller
• Up to 400 indoor units can be controlled System Controller Lite
• Control and monitor Fujitsu’s air conditioner via LAN or Internet. • Up to a maximum of 4 VRF network systems, 1600 indoor units, and
• Easy maintenance & installation 400 outdoor units can be controlled.*
• Simple BMS, 3rd party supported by Modbus communication can be
controlled.
Indoor Units For Light Commercial Convertor / Adaptor Service & Maintenance Tool
Various indoor units Various Convertors Service Tool & Web Monitoring Tool
• 4 types 35 models • 4 models of hardware and software are put on the market all together. • Extensive monitoring and analysis functions for installation and
• The substantial capacity range and maintenance
BACnet®Gateway KNX® Convertor External Switch
indoor unit type suit to various room • Troubleshooting is performed by
Controller
size and layout monitoring each air conditioning
• 4 types 1.1 kW indoor units unit remotely during periodical
Circular Flow Cassette Mini Duct Compact Floor system checks.
Software For VRF
• Automatic operation check for
refrigeration cycle.
6 7
Light Commercial Solutions
SMALL OFFICES
Comfortable office air
conditioning without airflow
feeling
Fujitsu General provides perfect total air conditioning systems that take into
account energy saving, low noise, comfortable airflow, small room application
and Centralized control for small-sized office buildings with many small rooms.
3.2 m
8.8 m
Human sensor
(option)
Up to 12 HP by compact
outdoor unit
Facilities
Small VRF system is suitable for the buildings with many
Lightning Ventilation Energy Recovery Ventilator
small rooms. Max. 30 indoor units can be connected.
8 9
Light Commercial Solutions
HOTELS
Guest room air conditioning
with excellent comfort, energy saving
and easy installation
Space saving
Fujitsu General provides perfect total air conditioning systems that take Mini duct type with 198 mm
into account comfort, energy saving, external appearance, safety and height and 450mm depth.
This can be installed in
easy installation for small low-rise hotels. narrow ceiling space easily.
Mini Duct
Appearance-oriented compact
outdoor unit
Due to the lowest and most compact design in the
industry, the appearance of hotel is not damaged even
when installed on the building.
Large space air conditioning in Ventilation of the whole Centralized control of air Safety measures
the reception and lobby hotel supported conditioning in shared spaces
Ultra-large duct type single split system suitable for Outdoor air processing is essential in hotel spaces Air conditioning in shared spaces such as lobbies Refrigerant leak detection system is provided. This system
large spaces with high ceilings with a high degree of airtightness. The DX-Kit can and hallways is controlled centrally. Temperature detects a refrigerant leak and then sounds an alarm to shut
link up with air conditioners to ensure sufficient and operating conditions can be managed off the leakage.
ventilation. This system can be expanded. without the adjustment by guests.
Refrigerant
leak detector
Large Duct
• Emergency stop in the event of an emergency
• Emergency stop function for each refrigerant system
System Controller (VRF system)
10 11
Light Commercial Solutions
12 13
Commercial Solutions
VRF system
Control unit
EEV unit
DX-Kit
Wired R.C.
Thermistor
8 HP - 48 HP 34 Models
• Space saving combination: 8 HP to 48 HP/21 models
System Controller
• Energy efficiency combination: 16 HP to 44 HP/13 models
(UTY-APGXZ1)
System Controller Lite
(UTY-ALGXZ1 & UTY-PLGXX2)
8 HP - 54 HP 39 Models
• Space saving combination: 8 HP to 54 HP/24 models
• Energy efficiency combination: 16 HP to 46 HP/15 models
14 15
AIRSTAGETM VRF SYSTEMS CAN BE DESIGNED TO
CREATE AN AIR CONDITIONING SOLUTION TO
SUIT MOST BUILDINGS REQUIREMENTS.
AIRSTAGE
TM
HIGH ENERGY EFFICIENCY
CORE TECHNOLOGY
MORE COMFORT
HIGH RELIABILITY
DESIGN FLEXIBILITY
EASY INSTALLATION
EASY SERVICE & MAINTENANCE
16 17
AIRSTAGE CORE TECHNOLOGY
TM
limitation 28
26
The minimum and maximum temperature ranges can
be limited, which provide further energy saving while 24
Auto-off timer
New wired remote controller is equipped with an OFF timer
function that automatically stops operation when a fixed time
has elapsed from the start of operation. This prevents waste of
energy.
Furthermore a new wired remote controller can set up the
interval of time in case operation stops. Set interval time hour (17:00 to 24:00)
ON Auto OFF
60%
1
40%
0 0%
Heat Recovery (10HP) Heat Pump (8HP) Heat Pump (6HP) Time
18 19
AIRSTAGE CORE TECHNOLOGY
TM
MORE COMFORT
Precision refrigerant flow control High
Hot
Hot ± 0.5°C
Precise and smooth refrigerant flow control is achieved by using Set temp.
a DC Inverter control in conjunction with individual indoor unit
electronic expansion valve control. This allows high precision Cold
comfortable temperature control of ±0.5°C.
Low
Thermal change of the room
*Simulation in heating operation.
Comfortable operation is
Reach the set achieved due to a small variation of
temperature quickly room temperature
Quiet operation
Low noise mode
Two low noise modes can be selected automatically by quiet priority setting and capacity priority
setting depending on the indoor environment and outside temperature load. This feature can be
controlled via outdoor unit external input and/or system controller.
Quiet priority setting Capacity priority setting
Air Air
conditioning conditioning
load factor Heat load load factor Heat load
20 21
AIRSTAGE CORE TECHNOLOGY
TM
HIGH RELIABILITY
Backup operation
If one compressor fails, backup operation will be performed by
the remaining compressors*.
*: Note: Backup operation may not be possible depending on the trouble state.
Outdoor unit rotational operation ensure no liquid refrigerant is being fed into the compressor.
Large sized
Accumulator
The compressor starting order is rotated so that the running time is shared.
Rotation
Liquid refrigerant
(stays inside of
accumulator)
DC DC DC DC DC DC
1 2 3 1 2 3
Corrosion resistant of the heat exchanger has been improved Cobalt Blue protection
by the introduction of blue fin treatment to the outdoor unit’s Standard chromate protection
heat exchanger.
Aluminium base material
Rotation Rotation
DC DC DC Hydrophilic coating
1 2 3
Note: Rotational operation is alternated by the start / stop timing of the compressor.
22 23
AIRSTAGE CORE TECHNOLOGY TM
DESIGN FLEXIBILITY
Overall piping length 1,000m Total pipe length
High capacity connection
1,000m max. AIRSTAGETM VR-II series AIRSTAGETM V-III series
Heat Recovery type Heat Pump type
8HP-48HP 8HP-54HP
Connectable indoor unit Connectable indoor unit
capacity range capacity range
Actual pipe length
50% to 150%*1 50% to 150%*3
165m Height difference
(VR-II, V-III) between outdoor and Connectable indoor Connectable indoor
indoor units unit number unit number
50m max. up to 64 up to 64
For the outdoor unit installed below
the indoor units: 40m max.
AIRSTAGETM J-IIIL series AIRSTAGETM J-III series
Heat Pump type Heat Pump type
8HP-12HP 4HP-6HP
Connectable indoor unit Connectable indoor unit
capacity range capacity range
Pipe length from first
separation tube to the Height difference
between indoor and
50% to 150% 50% to 150%*1 *1. Conditions of maximum connectable indoor unit
capacity ratio is as the chart below.
farthest indoor unit
indoor units *2. Only 4HP is 46%
60m max. 15m max.
Connectable indoor
unit number
Connectable indoor
unit number
*3. Max. capacities in the combinations including the
(VR-II) 18HP outdoor unit fall below 150%.
up to 30 up to 13 Maximum connectable
90m* max. Series
indoor unit capacity ratio
(V-III) Without 1.1kW With 1.1kW
models models*4
AIRSTAGETM J-IIS series
Heat Pump type VR-II 150% 130%
*: The limitation on the pipe J-IIIL 150% 150%
length between the farthest Connectable indoor unit
capacity range J-III 150% 150%
IU and the nearest IU
4HP-6HP
originated from the first
separation tube must be
50 %*
2
to 130 %*
1 J-IIS 130% 117%
24 25
AIRSTAGE CORE TECHNOLOGY
TM
EASY INSTALLATION
Easily transported Simple wiring work
Easily craned using lifting belt hooks Installation of the wiring systems is made easier as the
communication wiring can be installed continuously between
Design of outdoor unit allows for lifting
the indoor, outdoor and RB units.
straps to be used
or
Transporting by forklift
Transport with forklift is possible.
Easy evacuation - using vacuum Air Air
mode function
The vacuum mode function enables all expansion valves of
indoor units to be fully opened, making it easy to evacuate all
the air inside pipe lines and indoor units.
Air
Outdoor unit Vacuum pump
Can be transported in
a small elevator Automatic address setting
The address of the indoor unit, RB unit and signal amplifier can be set through the automatic function setting on the outdoor unit PCB.
1 Signal Amplifier
RB unit 3 7 1 0
Flexible installation by
4 way pipe direction
(J-IIIL is 3 way pipe direction.)
26 27
AIRSTAGE CORE TECHNOLOGY
TM
Service Tool
UTY-ASGXZ1
Outdoor unit Software
Transmission line
USB adaptor
(Locally purchased)
7-segment LED
Web
Monitoring Tool
Unit number
Error and
quantity Indoor unit
Wired Remote Controller annunciation
(Touch panel)
Error status / Error history
Error code
Abnormal indoor
unit address
28 29
The AIRSTAGE 5 Series has a total of 85 models
to meet the environmental and
building size requirements.
The AIRSTAGE series outdoor units were developed with structural designs and
AIRSTAGE
TM
AIRSTAGE™ LINE-UP
SERIES
HEAT RECOVERY TYPE AIRSTAGE VR-II
HEAT PUMP TYPE AIRSTAGE V-III
HEAT PUMP TYPE AIRSTAGE J-IIIL
HEAT PUMP TYPE AIRSTAGE J-III
HEAT PUMP TYPE AIRSTAGE J-IIS
30 31
AIRSTAGE Series TM
AIRSTAGE™ LINE-UP
Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series
matched to the size and application of the property.
kW class 12.1 14.0 15.5 22.4 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5 78.5 85.0 90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 139.0 143.0 147.0
Space
saving
AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH AJH432GALH
Heat Recovery
High
Efficiency
AJH144GALHH AJH198GALHH AJH216GALHH AJH234GALHH AJH252GALHH AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH342GALHH AJH360GALHH AJH378GALHH AJH396GALHH
Space
saving
AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH180LALBH AJH198LALBH AJH216LALBH AJH234LALBH AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH AJH342LALBH AJH360LALBH AJH378LALBH AJH396LALBH AJH414LALBH AJH432LALBH AJH450LALBH AJH468LALBH AJH486LALBH
Heat Pump
High
Efficiency
AJH144LALBHH AJH162LALBHH AJH180LALBHH AJH216LALBHH AJH234LALBHH AJH252LALBHH AJH270LALBHH AJH288LALBHH AJH306LALBHH AJH324LALBHH AJH342LALBHH AJH360LALBHH AJH378LALBHH AJH396LALBHH AJH414LALBHH
Space
saving
Heat Pump
AJH072LELAH AJH090LELAH AJH108LELAH
High
Efficiency
(Single phase)
AJH040LBLAH AJH045LBLAH AJH054LBLAH
Heat Pump
High
Efficiency
(3 phase)
AJH040LELAH AJH045LELAH AJH050LELAH
Space
Heat Pump saving
AJH040LCLAH AJH045LCLAH AJH054LCLAH
32 33
Features
(COP) 5
4.39 4.30 4.34 4.30
4.13 4.07 4.05 4.01 4.01 4.00 4.00
3.90 3.92 3.90 3.91 3.92 3.90 3.91 3.91 3.98 3.92
4
Space saving
Smart and cutting edge design
combination 3
Extensive lineup from 8HP to 48HP in 2HP increment
Connectable indoor unit capacity ratio up to 150%
2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 (HP)
System Outline 4
4.39
4.22
4.39 4.35 4.32 4.30
4.24 4.23 4.18 4.17
4.08 4.13 4.05
Space saving Energy efficiency
Energy efficiency
Simultaneous cooling and heating operation combination 3
using 1 refrigerant system
Cooling and heating can be freely selected for each indoor COP 12.6% UP
2
unit to provide simultaneous cooling and heating in rooms 16 22 24* 26 28 30 32 34 36 38 40 42 44 (HP)
with large temperature differences.
34 35
Features
RB Unit RB Unit
(Single type) (Multi type)
Capacity
speed control Max.3 or 8
Max. 8 indoor unit
indoor units
Comfortable space with 0.1Hz
small room temperature
changes and little energy Single Group Single
&
Group RB Unit less
loss is created by 0.1Hz connection connection connection connection connection*2
• The RB unit can be freely positioned between the first branch and the indoor unit.
• The maximum height difference between RB units is 15 m.
* 2. RB Unit is not necessary for cooling only use.
Inverter frequency
Small intake
airflow Heat •Up to 2 units can be
EEV exchanger
Distributor connected in series. RB unit Ceiling
Heat exchanger
Outdoor unit
36 37
Outdoor units lineup
• Combinations other than the followings are not recommended.
80 530
(Bolt pitch) 8-12 × 17 (Hole)
765 930
78.5kW (28HP) 85.0kW (30HP) 90.0kW (32HP) 95.0kW (34HP) 100.5kW (36HP)
1690
1576
1339
AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH
UNIT : AJH144/108GALH UNIT : AJH144/126GALH UNIT :AJH144/144GALH UNIT : AJH108/108/A90GALH UNIT : AJH108/108/108GALH
106.5kW (38HP) 112.0kW (40HP) 118.0kW (42HP) 123.5kW (44HP) 130.0kW (46HP)
B A C
765 1240
44.8kW (16HP) 62.4kW (22HP) 67.2kW (24HP) 72.8kW (26HP) 78.4kW (28HP)
1690
AJH144GALHH AJH198GALHH AJH216GALHH AJH234LALHH AJH252GALHH
UNIT : AJHA72/A72GALH UNIT : AJH126/A72GALH UNIT : AJHA72/A72/A72GALH UNIT : AJHA90/A72/A72LALH UNIT : AJHA90/A90/A72GALH
84.0kW (30HP) 90.4kW (32HP) 96.0kW (34HP) 102.4kW (36HP) 108.0kW (38HP)
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
199
38 39
Outdoor units specifications
Model name AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH AJH432GALH
Unit 1 AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJHA90GALH AJHA90GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH
Unit 2 AJHA72GALH AJHA90GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH108GALH AJH108GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH
Unit 3 AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH
Maximum Connectable Indoor Unit*1 15 16 17 21 24 32 30 32 35 39 42 45 48 50 53 57 60 63 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.2-75.6 28.0-84.0 30.8-92.2 33.5-100.5 36.5-109.5 39.3-117.7 42.5-127.5 45.0-135.0 47.5-142.5 50.3-150.7 53.3-159.7 56.0-168.0 59.0-177.0 61.8-185.2 65.0-195.0 67.5-202.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 67.0 73.0 78.5 85.0 90.0 95.0 100.5 106.5 112.0 118.0 123.5 130.0 135.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 75.0 81.5 87.5 95.0 100.0 106.5 112.5 119.0 125.0 131.5 137.5 145.0 150.0
Cooling 5.45 7.11 9.75 11.34 13.61 12.56 14.22 16.86 19.50 20.72 23.36 24.95 27.22 26.61 29.25 30.47 33.11 34.33 36.97 38.56 40.83
Input power kW
Heating 5.70 7.33 9.62 10.90 12.77 13.03 14.66 16.95 19.24 20.10 22.39 23.67 25.54 26.57 28.86 29.72 32.01 32.87 35.16 36.44 38.31
EER Cooling 4.11 3.94 3.44 3.53 3.31 4.01 3.94 3.65 3.44 3.52 3.36 3.41 3.31 3.57 3.44 3.50 3.38 3.44 3.34 3.37 3.31
W/W
COP Heating 4.39 4.30 3.90 4.13 3.92 4.34 4.30 4.07 3.90 4.05 3.91 4.01 3.92 4.01 3.90 4.00 3.91 4.00 3.91 3.98 3.92
Air flow rate High m3/h 11,100 11,100 11,100 13,000 13,000 11,100×2 11,100×2 11,100×2 11,100×2 13,000+11,100 13,000+11,100 13,000×2 13,000×2 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
Model name AJH144GALHH AJH198GALHH AJH216GALHH AJH234GALHH AJH252GALHH AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH342GALHH AJH360GALHH AJH378GALHH AJH396GALHH
Unit 1 AJHA72GALH AJH126GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJH144GALH AJH126GALH AJH144GALH
Unit 2 AJHA72GALH AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH
Unit 3 AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH
Maximum Connectable Indoor Unit*1 24 33 36 39 42 45 48 51 54 57 60 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 31.2-93.6 33.6-100.8 36.4-109.2 39.2-117.6 42.4-126.0 45.2-135.6 48.0-144.0 51.2-153.6 54.0-162.0 56.5-169.5 60.0-180.0 62.5-187.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 62.4 67.2 72.8 78.4 78.4 90.4 90.4 102.4 108.0 113.0 120.0 125.0
Capacity kW
Heating 50.0 70.0 75.0 81.5 88.0 88.0 101.5 101.5 115.0 121.5 126.5 135.0 140.0
Cooling 10.90 16.79 16.35 18.01 19.67 19.67 23.90 23.90 28.13 29.79 32.06 34.02 36.29
Input power kW
Heating 11.40 16.60 17.10 18.73 20.36 20.36 23.93 23.93 27.50 29.13 31.00 32.70 34.57
EER Cooling 4.11 3.72 4.11 4.04 3.99 3.99 3.78 3.78 3.64 3.63 3.52 3.53 3.44
W/W
COP Heating 4.39 4.22 4.39 4.35 4.32 4.32 4.24 4.24 4.18 4.17 4.08 4.13 4.05
Air flow rate High m3/h 11,100×2 13,000+11,100 11,100×3 11,100×3 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3
40 41
Features
combination 3
Excellent energy saving
Heat pump inverter type realizes the highly energy COP 17% UP
2
saving air conditioning for individual cooling and heating 16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)
operation by all inverter technology for seasonal efficiency.
High design flexibility for Energy saving technology that boosted operation efficiency
various building air conditioning
High design flexibly meets the various needs of high-rise Powerful large propeller fan
building air conditioning such as outdoor unit roof top By using CFD*1 technology, a newly designed fan achieves high performance
concentrated installation and each floor installation by and low noise operation. *1. CFD = Computational Fluid Dynamics
large capacity combination, sufficient connection capacity,
and high static pressure design.
3 phase DC fan motor
Efficiency is substantially improved by high efficient motor with sophisticated
driver control. In addition, low noise is realized by DC fan motor.
Easy installation and maintenance
The flexible communication method and piping
connections makes installation and maintenance easy Subcool heat exchanger
even for large systems. High Heat Exchange efficiency is achieved by using an internal projection
shape double pipe construction.
0.1Hz
Capacity
Large Office System configuration example ALL DC inverter compressor
• This system is used for medium-sized and large buildings. Large capacity high efficient DC twin rotary compressor
Connecting each outdoor unit makes it possible to create a high- with 0.1Hz steps compressor speed control Inverter frequency
capacity system.
• Connection of multiple indoor units using separation tubes and 4-face heat exchanger
headers. Heat exchange efficiency is significantly improved by the introduction of a
new 4-face heat exchanger that increases effective surface area.
Outdoor unit
Front intake port (corner cut air inhaling structure)
Separation tube Header
Larger
refrigerant flow
Large intake airflow
42 43
Outdoor units lineup
• Combinations other than the followings are not recommended.
80 530
(Bolt pitch) 8-12 × 17 (Hole)
765 930
78.0 kW (28HP) 85.0 kW (30HP) 90.0 kW (32HP) 95.0 kW (34HP) 100.0 kW (36HP)
1690
1576
1339
AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH
UNIT : AJH162/090LALBH UNIT : AJH144/126LALBH UNIT : AJH144/144LALBH UNIT : AJH162/144LALBH UNIT : AJH162/162LALBH
106.0 kW (38HP) 113.0 kW (40HP) 118.0 kW (42HP) 123.0 kW (44HP) 128.0 kW (46HP)
B A C
135.0 kW (48HP) 140.0 kW (50HP) 145.0 kW (52HP) 150.0 kW (54HP) 1000 (Bolt pitch)
80 840 (Bolt pitch)
8-12×7 (Hole)
765 1240
44.8 kW (16HP) 50.4kW (18HP) 55.9 kW (20HP) 67.2 kW (24HP) 72.8 kW (26HP)
1690
AJH144LALBHH AJH162LALBHH AJH180LALBH AJH216LALBHH AJH234LALBHH
UNIT : AJH072/072LALBH UNIT : AJH090/072LALBH UNIT : AJH108/072LALBH UNIT : AJH072/072/072LALBH UNIT : AJH090/072/072LALBH
78.3 kW (28HP) 84.8 kW (30HP) 89.4 kW (32HP) 95.9 kW (34HP) 100.5 kW (36HP)
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
199
44 45
Outdoor units specifications
Model name AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH180LALBH AJH198LALBH AJH216LALBH AJH234LALBH AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH AJH342LALBH AJH360LALBH AJH378LALBH AJH396LALBH AJH414LALBH AJH432LALBH AJH450LALBH AJH468LALBH AJH486LALBH
Unit 1 AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH090LALBH AJH126LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH162LALBH
Unit 2 AJH090LALBH AJH072LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH126LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH090LALBH AJH126LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH
Unit 3 AJH090LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH144LALBH AJH144LALBH AJH144LALBH AJH162LALBH
Maximum Connectable Indoor Unit*1 17 21 26 30 34 39 43 47 52 56 60 64 64 64 64 64 64 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.0-67.5 28.0-84.0 31.2-93.6 34.0-102.0 36.5-109.5 39.0-109.5 42.5-127.5 45.0-135.0 47.5-135.0 50.0-135.0 53.0-151.5 56.5-169.5 59.0-177.0 61.5-177.0 64.0-177.0 67.5-202.5 70.0-202.5 72.5-202.5 75.0-202.5
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.0 56.0 62.4 68.0 73.0 78.0 85.0 90.0 95.0 100.0 106.0 113.0 118.0 123.0 128.0 135.0 140.0 145.0 150.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 50.0 63.0 70.0 76.5 81.5 81.5 95.0 100.0 100.0 100.0 113.0 126.5 131.5 131.5 131.5 150.0 150.0 150.0 150.0
Cooling 5.20 7.28 8.96 10.96 13.01 16.56 14.56 16.16 18.24 20.29 23.84 23.97 26.02 29.57 33.12 31.12 31.25 33.30 36.85 40.40 39.03 42.58 46.13 49.68
Input power kW
Heating 5.17 7.25 8.65 11.17 13.63 13.63 14.50 16.34 18.42 20.88 20.88 24.80 27.26 27.26 27.26 28.13 32.05 34.51 34.51 34.51 40.89 40.89 40.89 40.89
EER Cooling 4.31 3.85 3.74 3.65 3.46 3.02 3.85 3.86 3.73 3.60 3.27 3.55 3.46 3.21 3.02 3.41 3.62 3.54 3.34 3.17 3.46 3.29 3.14 3.02
W/W
COP Heating 4.84 4.35 4.34 4.03 3.67 3.67 4.34 4.28 4.15 3.90 3.90 3.83 3.67 3.67 3.67 4.02 3.95 3.81 3.81 3.81 3.67 3.67 3.67 3.67
13,700+13,000+
Air flow rate High m3/h 11,100 11,100 13,000 13,000 13,700 13,700 11,100×2 13,000+11,100 13,000+11,100 13,000+11,100 13,700+11,100 13,700+13,000 13,700×2 13,700×2 13,700×2 13,700+11,100×2 13,700×2+11,100 13,700×2+11,100 13,700×2+11,100 13,700×3 13,700×3 13,700×3 13,700×3
11,100
Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm
Discharge Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Model name AJH144LALBHH AJH162LALBHH AJH180LALBHH AJH216LALBHH AJH234LALBHH AJH252LALBHH AJH270LALBHH AJH288LALBHH AJH306LALBHH AJH324LALBHH AJH342LALBHH AJH360LALBHH AJH378LALBHH AJH396LALBHH AJH414LALBHH
Unit 1 AJH072LALBH AJH090LALBH AJH108LALBH AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH108LALBH AJH126LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH AJH144LALBH AJH144LALBH
Unit 2 AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH AJH144LALBH
Unit 3 AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH
Maximum Connectable Indoor Unit*1 34 39 43 52 56 60 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 25.2-75.6 28.0-83.8 33.6-100.8 36.4-109.2 39.2-117.4 42.4-127.2 44.7-134.1 48.0-143.8 50.3-150.7 53.5-160.5 56.8-170.2 60.0-180.0 62.5-187.5 65.0-195.0
Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 50.4 55.9 67.2 72.8 78.3 84.8 89.4 95.9 100.5 107.0 113.5 120.0 125.0 130.0
Capacity kW
Heating 50.0 56.5 62.5 75.0 81.5 87.5 95.0 100.0 107.5 112.5 120.0 127.5 135.0 140.0 145.0
Cooling 10.40 12.48 14.16 15.60 17.68 19.36 21.36 23.12 25.12 26.88 28.88 30.88 32.88 34.93 36.98
Input power kW
Heating 10.34 12.42 13.82 15.51 17.59 18.99 21.51 22.47 24.99 25.95 28.47 30.99 33.51 35.97 38.43
EER Cooling 4.31 4.04 3.95 4.31 4.12 4.04 3.97 3.87 3.82 3.74 3.70 3.68 3.65 3.58 3.52
W/W
COP Heating 4.84 4.55 4.52 4.84 4.63 4.61 4.42 4.45 4.30 4.34 4.21 4.11 4.03 3.89 3.77
46 47
Features
1,428mm
16 %
System Outline
Space area
Compact Outdoor unit
The compact and low sound level enable the units to be
0.71m 2
Quiet design
Top class low sound operation has been achieved. This Advanced high efficiency technology
allows installation of the units to various places without a
special sound prevention work.
570mm
Large propeller fan DC inverter control
The high efficiency and the low sound Efficiency is improved by mounting of new
operation are mutually realized by active filter module.
reduction of a draft loss which are enabled
by the Fujitsu General's original blade
design and a large diameter propeller fan.
Small Office System configuration example
• This system is used for small and medium-sized buildings. 1
refrigerant system is used for each outdoor unit.
• Connection of multiple indoor units using separation tubes and
headers.
Subcool heat exchanger
Cooling performance is improved by
DC fan motor mounting of dual tube heat exchanger.
Miniaturized, low noise, high efficiency,
Pressure
Outdoor unit multi-stage DC fan motor is mounted.
effect
Enthalpy
Indoor unit
Liquid pipe Scroll compressor
Gas pipe The equipment of scroll compressor with a
Large heat exchanger wide range of rotational frequency from 15
Heat exchange performance is substantially 15-120
20 rps to 120 rps together with Fujitsu General's
unique sensorless sine wave control method
improved by mounting of 2.6-row large
heat exchanger. which smoothly control the input power run
Indoor unit into the motor realized a mutual
improvement on the energy efficient
operation and the low sound operation.
48 49
Features
30 Pa 1080 480
1428
Top Class Low Operating Sound
480
516
Top class low operating sound is realized. Highly suited Sound Power level
38
to densely populated areas thanks to their low operating
sound.
66 dB(A) 77dB(A)
130
79
50
22
11dB(A)
50 51
Features
5.01
Fujitsu General provides air conditioning systems 4.70
4.86 7 % UP
for a wide range of applications 4.33 4.41 4.51 8 % UP
4.17 4.23 4.23
4.05 3.92 3.95
from small office buildings and stores to large houses. 3.88
3.71 3.71
3.45
System Outline
High Energy Efficiency
Heat pump inverter control is used to achieve an efficient 4HP 5HP 6HP 4HP 5HP 6HP J-II J-III J-II J-III
cooling and heating operation in any indoor unit
combination.
DC fan motor
Miniaturized, low noise, high efficiency,
multi-stage DC fan motor is mounted.
Pressure
effect
Large heat exchanger
Outdoor unit
Heat exchange performance is substantially
improved by mounting of 3-row large heat
Separation tube Header
exchanger.
Compressor
efficiency
Highly accurate parts
DC Twin Rotary compressor
Indoor unit
52 53
Long piping capability Specifications
Total pipe length
Our advanced refrigerant control technology allows us
180m max.
Rating Capacity range HP 4 5 6 4 5 6
to achieve a total refrigerant piping length of 180m. This Model name AJH040LBLAH AJH045LBLAH AJH054LBLAH AJH040LELAH AJH045LELAH AJH054LELAH
opens up new possibilities in system design. Maximum Connectable Indoor Unit 1-9 1-10 1-13 1-9 1-10 1-13
43(Liquid)
51(Gas)
A comfortable room condition is maintained during oil recovery Previous model J-III series (Heating operation)
(410)
370
mode because the product continues to operate without
40
stopping the cooling or heating operation.
32
36
970 32 370 12
ON ON
OFF
Time Time
Terminal blocks (Power)
1334
Easier Installation
1000
907
3-Way valve (Liquid)
111
wiring connection and address setting are correct by a
70
le port)
(Liquid valve)
(Gas valve)
ab
Ø28 (C
quick check run function.
297
279
120
21
25
95
155
142
131
87
Ø28 (Cable port) Ø28 (Cable port)
50
50
50
Ø28 (Cable port) 89 Pipe port 21 55 Ø28 (Cable port) 21 65 Ø28 (Cable port)
Pipe port Pipe port
A
Detail A
65 15
227
305
14
341
50
• Display connected indoor unit numbers
50
• Duplicately set address number of indoor unit can be 438 Pipe & cable port
displayed 622
54 55
Features
Height difference
998 mm
▲25%
System Outline Low sound level design
Significantly low sound level is improved by using
Light weight
Space saving and low sound level design DC twin rotary compressor, inverter technology, and
Economical individual air conditioning is realized by ALL-DC 87 kg advanced airflow structure design.
technology, large capacity DC twin rotary compressor, and
Cooling 56
3-row heat exchanger though the size is compact.
dB(A)
54
53
Flexible systems for homes, shops,
small-size buildingss air conditioning 51
Due to compact size design and flexible piping design,
J-IIS series can be installed easily at the place where the 4 HP 5 HP 6 HP 6 HP
installation space is limited such as homes, shops, and small
Previous model
offices. Multiple indoor units of various capacities and types
can be connected.
Advanced high efficiency technology
Outdoor unit
High efficiency
compressor motor
Separation tube Header DC fan motor
Miniaturized, low noise, high Optimized refrigerant
efficiency, multi-stage DC fan flow design
motor is mounted.
Highly accurate
parts
Indoor unit
Compact and
Liquid pipe high performance
Smooth airflow grille
Gas pipe
This grille was aerodynamically designed for
DC twin rotary compressor
good efficiency with little blow loss. Efficiency in all load regions is good.
Especially good performance from low
to medium at normal operation.
Indoor unit Large heat exchanger
Heat exchange performance is High
substantially improved by
mounting of 3-row large heat
Compressor
efficiency
exchanger.
56 57
Features
Piping length from first Note : Specifications are based on the following conditions.
separation tube to the Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
farthest indoor unit Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
40m max.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Height difference between The protective function may work when using it outside the operation range.
indoor and indoor units
ON ON
OFF
Time Time
Easier Installation
Connection check function : Possible to confirm whether Front view
wiring connection and address setting are correct by a Rear view
quick check run function. Side view
Bottom view
• Display connected indoor unit numbers
• Duplicately set address number of indoor unit can be
displayed Detail A
58 59
16 Types and 97 models available to meet
the requirements of any building design.
The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise
and to have user friendly operation. With a variety of indoor units and capacities
available, Fujitsu General has an indoor unit to match any requirement which is easy
AIRSTAGE
TM INDOOR UNITS LINE-UP
4-way Flow Compact Cassette
INDOOR UNITS
4-way Flow Cassette
Circular Flow Cassette
Mini Duct
Slim Duct / Slim Concealed Floor
Low Static Pressure Duct / Concealed Floor
Medium Static Pressure Duct
High Static Pressure Duct
Large Airflow Duct
Compact Floor
Floor / Ceiling
Ceiling
Compact Wall Mounted / Wall Mounted
60 61
AIRSTAGE Indoor units
TM
Capacity range (kW) 1.1 2.2 2.8 3.6 4.5 5.6 7.1 9.0 10.0 11.2 12.5 14.0 18.0 22.4 25.0 28.0
(Slim type)
AUXD18GALH AUXD24GALH
4-way Flow
(Slim type)
AUXM018GLAH AUXM024GLAH AUXM030GLAH
Circular Flow
(Large type)
AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH
Mini Duct
(With drain pump)
ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH
Slim Duct
(With drain pump)
ARXD04GALH*3 ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
(Compact type)
(Large type)
ARXN18GATH*2 ARXN24GATH*2 ARXN30GATH*2 ARXN34GATH*2 ARXN36GATH*2 ARXN45GATH*2
Floor
(Same as Ceiling models)
ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH
Compact Floor
AGHA004GCAH AGHA007GCAH AGHA009GCAH AGHA012GCAH AGHA014GCAH
Ceiling Ceiling
ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH
Wall Mounted
ASHA18GACH ASHA24GACH ASHA30GACH
Wall Mounted
570mm
High lift drain pump
Ceiling panel
in the compact cassette
Max.
category
(Easy installation by taking off 700mm
Models
ceiling panel of 600 x 600 size)
AUXB04GBLH
AUXB07GALH
AUXB09GALH
AUXB12GALH
Optional parts
AUXB14GALH
Air Outlet Shutter Plate : UTR-YDZB
AUXB18GALH Insulation Kit for High Humidity : UTZ-KXGC
AUXB24GALH Fresh Air Intake Kit : UTZ-VXAA
Specifications
Model name AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.1 5.0 6.3 8.0
2-stage turbo fan Quiet quality Input power W 23 25 25 29 35 36 84
High 530 540 550 600 680 710 1,030
High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and
Airflow rate Med m3/h 420 / 450*1 450 450 530 590 580 830
wing number (7 blades each)
An evenly spread air distribution across the heat Low 300 / 350*1 350 350 390 390 400 450
Designed by CFD-analysis (fluid) simulations
exchanger is possible due to the new 2 stage turbo fan High 34 34 35 37 38 41 50
Sound pressure dB
which produces two separate airflow streams. level
Med
(A)
28 / 30*1 30 30 34 34 35 44
Adoption of laminar wing Low 21 / 25*1 25 25 27 27 27 30
1-stage 2-stage turbo fan Laminar wing
Wind velocity Dimensions (H × W × D) mm 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570
Fast Quiet Airflow runs through smoothly
Heat exchange Weight kg 15 15 15 15 15 17 17
efficiency along the laminar wing
+
2-stage
= 20%UP
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 15.88 15.88
Slow Drain hose diameter (I.D./O.D.) 25 / 32
Model name UTG-UFGC-W
Previous turbo fan
In the case of a previous fan, the air outlet range was narrow as the Quiet Cassette Grille Dimensions (H×W×D) mm 50 × 700 × 700
airflow moved to the motor side which meant the velocity of air Spin direction Weight kg 2.6
passing through the heat exchanger was uneven. No airflow separation
Airflow direction Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
700
18 2.7 3.0
2 24 2.7 3.0
Grille cover
75
1 Maintenance of fan motor and fan
Maintenance of the fan motor and fan can be done easily after taking
135 250
off the panel as the bell mouth of the fan can be removed easily. 700 Top view
116
30
49
102
262
2 Air filter : standard equipment
108
222
146
30
40
245
Side view
124
58
Ceiling
During installation, maintenance and operation, the drain pump Control box
and kit can be checked easily. Liquid pipe Gas pipe Side view
64 65
AIRSTAGE Indoor unitsTM
Specifications
Model name AUXD18GALH AUXD24GALH AUXA18GALH AUXA24GALH AUXA30GALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0
High efficiency turbo fan with 3-dimensional blade Input power W 39 46 51 51 59 77 80 99 119
High 1,150 1,280 1,420 1,420 1,600 1,750 1,800 1,900 2,000
High efficiency airflow distribution has been achieved by the introduction of a 3
Previous turbo fan Airflow rate Med m3/h 940 1,040 1,230 1,230 1,300 1,300 1,300 1,370 1,370
dimensional blade which increases the air passing over the heat exchanger.
Air passing through the heat exchanger was uneven and the air would only flow Low 870 870 1,100 / 1,000*1 1,100 / 1,000*1 1,100 1,100 1,100 1,100 1,100
close to the ceiling. High 36 38 40 40 40 43 44 46 47
500mm 450mm
Sound pressure
Med
dB
30 33 36 36 38 38 38 39 39
level (A)
Low 29 29 33 / 31*1 33 / 31*1 33 33 33 33 33
Previous blade
3-dimensional blade Dimensions (H × W × D) mm 246 × 840 × 840 246 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840
Weight kg 22 22 27 27 27 27 27 27 27
Heat exchanger Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Heat exchanger < Motor side > Separation pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05
< Motor side > phenomenon of Drain hose diameter (I.D./O.D.) 25 / 32
Wind velocity
Fast Quiet airflow
Model name UTG-UGGA-W
causes noise
No airflow separation Cassette Grille Dimensions (H×W×D) mm 50 × 950 × 950
Uneven airflow
Slow Weight kg 5.5
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
: Spin direction : Airflow direction : Turbulent flow noise Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Rear part
Ceiling opening
Bottom view Round louver happens by spreading airflow widely
860 to 910
950
699
420
Adjustment of hanger position is High ceiling mode
607
possible after installation This cassette can be installed up to a height of 4.2m (36/45/54). Drain hose
358
The maximum height from floor to ceiling (m) (Control) Box
Model code
Detachable Standard mode High ceiling mode 358 278 60
Grille corner 18 3.0 3.5 40
24 3.0 3.5
289(256)
30 3.2 3.6
200
34 3.2 3.6
Adjustment can be done
just taking off the corner part 36 3.2 4.2
142
142
10
140
45 3.2 4.2 Liquid pipe
44
Ceiling Gas pipe
54 3.2 4.2 Wire hole
66 67
AIRSTAGE Indoor unitsTM
Specifications
Model name AUXM018GLAH AUXM024GLAH AUXM030GLAH AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 10.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0
orta ble! Note : Specifications are based on the following conditions. When AUX*018GLAH is connected to the outdoor unit other than J-IIIL, pipe diameter should
Comf
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. be Ø9.52/Ø15.88 (Liq/Gas)
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. When AUXK036GLAH, AUXK045GLAH, and AUXK054GLAH are connected to the outdoor unit
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. other than J-IIIL, gas pipe diameter should be Ø19.05.
768
768
950
direct blowing of cold air and by providing
950
298
200-205
200
256
Human sensor
(Option) Ceiling Ceiling Liquid pipe
39
39
Liquid pipe
Gas pipe Wire hole Gas pipe
68 69
AIRSTAGE Indoor units
TM
20 dB(A)
Auto Louver Grille Kit (Option)
• Thin design provides a comfortable
this model to install in a quiet location. living environment over a wide area.
at 04 model • Automatic louver grille provides
6-Step Speed comfortable air conditioning all the
Models (With drain pump)
High way down to the floor and matches
ARXK04GCLH the interior design well. (Optional)
ARXK07GCLH Med-H
ARXK09GCLH Med
ARXK04 ARXK07 ARXK09 ARXK12 ARXK14 ARXK18
ARXK12GCLH Med-L
Optional parts
ARXK14GCLH Low Remote Sensor Unit : UTY-XSZX
ARXK18GCLH IR Receiver Unit : UTB-YWC
Quiet
ARXK24GCLH Auto Louver Grille Kit : UTD-GXTA-W (for ARXK04/07/09/12/14GCLH)
* Compatible Remote Controller is as follows:
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 UTD-GXTB-W (for ARXK18GCLH)
UTD-GXTC-W (for ARXK24GCLH)
ARXK24
Specifications
Model name ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Large living space available Input power W 26 28 28 35 66 73 80
High 460 460 460 550 760 930 1,160
• Installation space can be reduced down to minimum Med-H 440 − − − − − −
depth 450mm height 198 mm and compact design (Unit: mm)
Airflow rate
Med
m3/h
420 420 420 480 560 740 960
• Minimum size: Depth 450mm, Height 198mm Volume Med-L 400 − − − − − −
Low 370 370 370 410 410 540 750
30% down compared with current model
Quiet 340 − − − − − −
• Lightweight: 16kg 10%down
Static pressure range 0 to 30 0 to 30 0 to 30 0 to 30 0 to 50 0 to 50 0 to 50
450
Pa
Standard static pressure 10 10 10 10 15 15 15
High 25 26 26 29 34 33 32
Med-H 24 25 25 27 31 30 30
198 225*
Sound pressure
level
Med
Med-L
Low
dB
(A)
23
22
21
24
23
22
24
23
22
26
25
24
28
26
24
28
26
24
28
27
25
Quiet 20 21 21 22 22 22 22
Dimensions (H × W × D) mm 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 900 × 450 198 × 1,100 × 450
600* Weight kg 14.5 15.5 15.5 16 16 19 22.5
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 9.52 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
*: Minimum installation dimension
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Optimum airflow path and low noise operation Easy design and maintenance for drain Dimensions (Unit: mm)
775 52
Low noise is realized drastically by stabilized airflow design By using the DC fan motor, it is possible to change the static pressure
range from 0 to 50 Pa*.
174
The change of static pressure range is possible by remote controller.
153
72
*: 0 to 30 Pa. (12) Rear view
295
30
450
Parts can be replaced from the
150
182
193
10
side of the body where
maintenance is easier 1 Refrigerant pipe flare connection (Liquid)
View A
30
A
B 49 2 Refrigerant pipe flare connection (Gas)
High efficient DC fan motor
Lower power consumption C 56 78 3 Drain hose connection
49 66
Top view Side view
85 92
V-shape heat exchanger
169 ARXK04-14 ARXK18 ARXK24
57
43
A P100×6=600 P100×8=800 P100×10=1000
198
168
150 B 650 850 1050
78
(Drain hose) C 752 952 1152
33
D D 650 850 1050
E
E 665 864 1064
F
F 700 900 1100
Front view
70 71
AIRSTAGE Indoor units
TM
Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize
Optional parts
Remote Sensor Unit : UTY-XSZX
IR Receiver Unit : UTB-YWC
with luxury interior.
Auto Louver Grille Kit : UTD-GXTA-W (for ARXD04/07/09/12/14GALH)
Slim Duct Auto Louver Grille UTD-GXTB-W (for ARXD18GALH)
Models (With drain pump) UTD-GXTC-W (for ARXD24GALH)
ARXD04GALH
ARXD07GALH
ARXD09GALH ARXD04 ARXD07 ARXD09 ARXD12 ARXD14 ARXD18
ARXD12GALH
ARXD14GALH
ARXD18GALH
ARXD24GALH ARXD24
Wired Remote Wireles Remote
Controller Controller
Slim Concealed Floor
Specifications
Model name ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Slim design Selectable with a wide range of Input power W 38 44 50 54 92 83 122
With a slim indoor design, this indoor can static pressure High 510 550 600 600 800 940 1,330
Airflow rate Med m3/h 400 / 470*1 490 550 510 710 840 1,240
be installed in narrow ceiling spaces. By using DC fan motor, it is possible to Low 320 / 440*1 440 480 450 610 750 1,100
Drain port change of static pressure range 0 to 90Pa. Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50
Pa
The change of static pressure range is Standard static pressure 25 25 25 25 25 25 25
possible by remote controller. Static pressure range High 26 28 29 30 34 34 35
Height Sound pressure dB
198mm 0 to 90 Pa level
Med
(A)
21 / 25*1 25 26 27 32 32 32
Low 20 / 22*1 22 24 24 28 28 29
*24 model is 0 to 50Pa Dimensions (H × W × D) mm 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 900 × 620 198 × 1,100 × 620
Drain pump
Drain pump Weight kg 17 17 17 18 18 22 26
built-in
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 15.88 15.88
High lift drain pump Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Air-intake Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Max. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Air intake direction can be selected
to match the installation site. 850mm
Bottom side Back side *Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Filter (Accessory) 51 G
174
152
71
30
ARXD04 / 07 / 09 / 12 / 14 / 18 ARXD24
Flexible installation Filter
(2pcs.)
Filter
(3pcs.)
(Bolt pitch)
377
Ceiling concealed 82
48
30
F E
(All surroundings) D
C
(Bolt pitch) ARXD04-14 ARXD18 ARXD24
10
Floor concealed 43 A 700 900 1100
163
119
198
168
89
78
55
47
78
72 73
AIRSTAGE Indoor unitsTM
Ceiling concealed
Models Height
ARXB07GALH 217mm
ARXB09GALH
ARXB12GALH Slim size (217mm) allows installation even where the space
above the ceiling is narrow.
ARXB14GALH
ARXB18GALH ARXB07GALH
ARXB09GALH
ARXB12GALH
ARXB14GALH
ARXB18GALH Floor concealed
Filter (Accessory)
ARXB07 / ARXB09 ARXB12 / ARXB14 / Filter
Filter ARXB18 (3pcs.)
Low noise level (2pcs.)
Low static pressure
A low noise level has been achieved for each capacity Normal mode Duct indoor unit
mode
Two-direction drain piping
Airflow drop
Airflow
prevention
Air-intake
Low noise
Model 79 12 14 18 Air intake direction can be selected to match the installation site.
realized
Static pressure
Pa 0 to 50
range
Optional parts
Noise level dB(A) 24 27 25 30 30
(Low speed) Remote Sensor Unit : UTY-XSZX
Static pressure (Pa) IR Receiver Unit : UTB-YWC
Bottom side Back side Drain Pump Unit : UTZ-PX1BBA
170
kW
Heating 2.8 3.2 4.0 5.0 6.3
Input power W 46 55 63 90 96 886 (596) 217
Control box
Airflow rate High 590 (164) (Bolt pitch) 194
370 (103) 440 (122) 800 (222) 890 (247)
3
m /h
Med (I/s) 310 (86) 370 (103) 500 (139) 750 (208) 810 (225)
1
Low 280 (78) 340 (94) 450 (125) 700 (194) 730 (203)
(Bolt pitch)
Brackets
3
390
Static pressure range 0 to 50 0 to 50 0 to 50 0 to 50 0 to 50 Brackets
Pa 2
587
595
Standard static pressure 25 25 25 25 25
364
Sound pressure level High 29 31 30 33 36
dB(A)
65 75
Med 26 29 28 32 34
166
Low 24 27 25 30 30
mm 24 47
Dimensions (H x W x D) 217 x 663 x 595 217 x 953 x 595
20
74 75
AIRSTAGE Indoor units
TM
ARXB45GATH
Easy setting by using remote controller Optional parts
Models (Medium Static Pressure Duct) Remote Sensor Unit : UTY-XSZX Flange (Round) : UTD-RF204
The change of static pressure
ARXA24GBLH range is possible by remote
Long Life Filter : UTD-LF25NA IR Receiver Unit : UTB-YWC
ARXA30GBLH Flange (Square) : UTD-SF045T Drain Pump Unit : UTZ-PX1NBA
controller
ARXA36GBLH
ARXA45GBLH
Specifications
Model name ARXB24GALH ARXB30GALH ARXB36GALH ARXB45GALH ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH
Feature Power source Single - phase, ~230V, 50Hz Single - phase, ~230V, 50Hz
Cooling 7.1 9.0 11.2 12.5 7.1 9.0 11.2 12.5
Capacity kW
Heating 8.0 10.0 12.5 14.0 8.0 10.0 12.5 14.0
Slim & Compact design Input power W 145 198 253 338 94 108 194 240
1,200 1,135mm High 1,100 1,410 1,710 1,970 1,280 1,410 1,840 1,970
In the case of bottom return air connection, not only does the
Control box is now included as Airflow rate Med m3/h 920 1,280 1,600 1,790 990 1,280 1,600 1,860
indoor unit design allow for installation in a narrow ceiling
part of the main chassis Low 810 1,150 1,470 1,670 840 1,150 1,470 1,640
space of up to 270mm, Further space savings have been
Static pressure range 0 to 80 0 to 80 0 to 80 0 to 80 0 to 150 0 to 150 0 to 150 0 to 150
achieved by mounting the electrical control box internally Standard static pressure
Pa
270mm 40 50 50 60 40 50 50 60
inside the chassis. High 31 34 37 41 31 34 37 41
Sound pressure dB
Med 27 32 35 38 27 32 35 38
level (A)
Low 25 29 33 36 23 29 33 36
One touch operating and easy to Dimensions (H × W × D) mm 270 × 1,135 × 700 270 × 1,135 × 700
install long life filter (Optional Parts)
Weight kg 39 42 42 42 36 40 40 40
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 19.05 19.05 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32 25 / 32
Low energy consumption by high Easy maintenance Note : Specifications are based on the following conditions.
efficiency DC fan motor See below for the case of rear suction type
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Improved motor efficiency 1
from previous model. Previous model 3
24 model 30 / 36 / 45 model
168
32 32
high-rise condominiums by low static ø200
(knock 1
pressure design. out hole)
240
240
138 264 264 264
281
New model 1 3
447(Bolt pitch)
82
138
700
4
It can also be installed in wide spade 3
2
when high static pressure is required,
such as for offices.
161
75
173
3 ø205 hole
1.Control box 2
2.Fan casing Front view
3.Fan
Bottom panel: P.C.D. ø225
4.Motor 240
2 pieces 1015 107
270
121 1135
76 77
AIRSTAGE Indoor units
TM
High Static Pressure Duct Easy installation (Compact size & Lightweight)
A compact size and lightweight (Unit:mm)
indoor unit has been developed
by reducing the basic chassis
Models Models and the overall material weight.
400
550
Models
450
ARXC36GBTH ARXC72GBTH ARXC96GATH
ARXC45GATH ARXC90GBTH 1,050 500 1,587 700
1,587 700
ARXC60GATH (ARXC36 / 45 / 60 type) (ARXC72 / 90 type) (ARXC96 type)
Optional parts
Long-Life Filter : UTD-LF60KA (For ARXC36 / 45 / 60)
IR Receiver Unit : UTB-YWC
Remote Sensor Unit : UTY-XSZX
ARXC96
Specifications
Model name ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH* ARXC90GBTH* ARXC96GATH*
Feature Power source Single - phase, ~230V, 50Hz
Cooling 11.2 12.5 18.0 22.4 25.0 28.0
Capacity kW
Heating 12.5 14.0 20.0 25.0 28.0 31.5
Static pressure selection Input power W 207 715 730 681 819 838
High 1,990 3,500 3,500 3,900 4,300 4,850
By using DC fan motor, it is possible to change static pressure range from 0 to 200Pa (ARXC36) / 300Pa (ARXC72 / 90 / 96).
Airflow rate Med m3/h 1,680 3,000 3,000 3,300 4,000 4,250
Low 1,330 2,460 2,460 3,000 3,500 3,600
[Pa]
Static pressure range 0 to 200 100 to 250 100 to 250 0 to 300 0 to 300 0 to 300
200 or 300 MAX. Pa
Standard static pressure 100 100 100 150 150 150
200 Pa High 42 49 49 47 48 48
Sound pressure dB
Med 36 45 45 43 46 45
(ARXC36 / 45 / 60 type) level (A)
Low 32 42 42 40 44 42
Dimensions (H × W × D) mm 400 × 1,050 × 500 400 × 1,050 × 500 400 × 1,050 × 500 450 × 1,587 × 700 450 × 1,587 × 700 550 × 1,587 × 700
MAX. Weight kg 40 46 46 84 84 105
300 Pa Connection
pipe diameter
Liquid
Gas mm
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
(ARXC72 / 90 type) Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *: ARXC60/72/90/96G cannot be connected to J-III series.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
MAX. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
0
[m3/h]
300 Pa Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
fan casing, has enabled less turbulent air flow. Low noise is realized from previous model.
527
427
504
404
by adopting a plastic case and a plastic fan.
411
311
327
227
71 Rear view 81 Rear view 81
Rear view
42
42
371 1587 1587
400 1,080(Bolt pitch) 356 450 8 1410(BOLT PITCH) 550 1410 (BOLT PITCH)
324 1,000 208 370 15 470 15 8
14 1250 149 1250 149
38
862 108 65 65
38
29
123
139
(ARXC36 type) (ARXC72 / 90 / 96 type)
653(BOLT PITCH) 29
41
New model
653(BOLT PITCH)
25
50
500(Bolt pitch)
50
25
1
700
700
585
2
(ARXC36GBTH)
50
25
3
50
25
4 P160×2 Ø3 150×7=1050 75 P160×2 P150×7=1050 75
Side view (R) =320 15 Side view (R) =320 15 1200 125
851 1200 125
295 350 35 1450 117 350 35 1450 117
1,050 85
Side view (L) Top view Side view (L) Top view Side view (L) Top view
1 Refrigerant piping flare connection (Liquid) 1 Refrigerant pipe flare connection (Liquid) 1 Refrigerant pipe flare connection (Liquid)
2 Refrigerant piping flare connection (Gas) 2 Refrigerant pipe flare connection (Gas) 2 Refrigerant pipe flare connection (Gas)
3 Drain piping connection 3 Drain hose 3 Drain hose
78 79
AIRSTAGE Indoor units
TM
ARXN018
ARXN024 ARXN030
Specifications
Model name ARXN018GLBH ARXN024GTBH ARXN030GTBH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0
Capacity kW
Heating 6.3 8.0 10.0
Large airflow volume Input power W 173 180 273
High 1,720 2,100 2,700
It can be installed in places such as early replacement of air Med-H - 2,050 2,390
required by large airflow volume. Airflow rate
Med
m3/h
1,470 1,860 2,080
Med-L - 1,660 1,770
Low 1,360 1,470 1,470
Quiet - 1,260 1,260
Static pressure range 0 to 80 0 to 100 0 to 100
Pa
Standard static pressure 50 50 50
High 36 37 41
Med-H - 35 38
Sound pressure Med dB 33 33 34
level Med-L (A) - 31 31
Low 30 28 28
Quiet - 26 26
Dimensions (H × W × D) mm 270 × 1,135 × 700 300 × 1,400 × 700 300 × 1,400 × 700
Weight kg 40 48 48
Connection Liquid (Flare) 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 15.88 15.88
Slim & Compact design Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
It can be installed in places such as early replacement of air required Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
by large airflow volume. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
(unit: mm) Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Dimensions
270 300
(Unit: mm)
168
Outlet 1295
32 32
ARXN018 ARXN024 / 030 ø200
Ø125
(knock 1
out hole)
240
240
281
3 Gas pipe
447(Bolt pitch)
Liquid pipe
Quiet operation
631
700
700
3
2 Air
Multistep airflow speed control allows this model
161
173
to install in a quiet location. Low noise
6-Step Speed
26 dB(A)
P.C.D. ø225 1015 107 240 1162
121 1135 270 Drain port Drain port
High 1400
Side view (L) Top view Side view (R) Side View (L) Top View Side View (R)
98
at 024/030 models Med-H
217
Med
Rear view Front View
Med-L
80 81
AIRSTAGE Indoor units
TM
Specifications
Model name ARXN18GATH ARXN24GATH ARXN30GATH ARXN34GATH ARXN36GATH ARXN45GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0 11.2 12.5
Capacity kW
Heating 6.3 8.0 10.0 11.2 12.5 14.0
Large airflow volume Input power W 154 205 306 432 572 572
High 2,280 2,640 3,200 3,720 4,120 4,120
It can be installed in places such as early replacement of air
Airflow rate Med m3/h ― ― ― ― ― ―
required by large airflow volume.
Low ― ― ― ― ― ―
Static pressure range 50 to 100 50 to 150 50 to 250 50 to 250 50 to 300 50 to 300
Pa
Standard static pressure 50 50 50 50 60 60
High 35 37 40 43 45 45
Sound pressure dB
Med ― ― ― ― ― ―
level (A)
Low ― ― ― ― ― ―
Dimensions (H × W × D) mm 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700
Weight kg 84 84 84 84 84 84
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. Large Airflow Duct can be connected to V-III series only.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Rear view
50 to 250 Pa 50 to 300 Pa
(30 / 34class) (36 / 45class) Air Flow
Top view
Optional parts
Remote Sensor Unit : UTY-XSZX Front view
82 83
AIRSTAGE Indoor units TM
Compact floor
Models (EEV internal)
AGHA004GCAH
AGHA007GCAH
AGHA009GCAH
AGHA012GCAH
AGHA014GCAH
Specifications
Model name AGHA004GCAH AGHA007GCAH AGHA009GCAH AGHA012GCAH AGHA014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.0
Capacity kW
Heating 1.3 2.8 3.2 4.0 4.5
2-Fan & Wide airflow Flexible & easy installation Input power W 12 / 14 16 17 22 29
High 380 / 430 470 500 590 670
Individual vertical airflow by 2-fan can control the whole room Due to compact and whole surface suction method model, floor, Med-H 350 420 450 520 590
comfortably. concealed, half concealed, or wall mounted installation can be Med 320 390 400 470 520
Airflow rate m3/h
available to match the room layout. Med-L 310 360 360 420 450
Low 280 330 330 390 390
Cooling Prevents cold air Beneath standard window Standard concave portion Quiet 210 270 270 340 340
from falling
(unit:mm) Min.900
High 35 / 36 37 38 42 46
Med-H 33 35 36 39 42
at stable
operation Min. 730 Max.
Max. 150 80 Dimensions (Unit: mm)
200
600
Med-H
Back view
Med
Med-L
1 6
Low
2 5
Quiet 3 Drain hose 4
Piping 740
* Compatible Remote Controller is as follows:
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 Front view Side view
84 85
AIRSTAGE Indoor units
TM
Models
ABHA12GATH
ABHA14GATH Super vane
ABHA18GATH 655 Double Louvre Super vane with newly developed special
ABHA24GATH configuration boosts airflow sending cool air quickly to every corner
of the room.
Floor standing
990
199
Specifications
Model name ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.5 5.6 7.1
Capacity kW
Heating 4.0 5.0 6.3 8.0
Flexible installation Input power W 30 42 74 99
High 660 780 1,000 1,000
Example for floor installation Example for ceiling installation
Airflow rate Med m3/h 570 640 720 820
Floor console Under ceiling Low 490 550 580 680
High 36 40 46 47
Sound pressure dB
Med 32 36 39 42
level (A)
Low 28 34 35 37
Dimensions (H × W × D) mm 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655
Weight kg 25 26 26 27
Connection Liquid (Flare) 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
5 steps selectable
3 2
1
4
86 87
AIRSTAGE Indoor units
TM
Fresh Max.
Models air
500mm
ABHA30GATH Indoor Outdoor
ABHA36GATH
ABHA45GATH
ABHA54GATH
Slim & Compact design
Specifications
Model name ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 9.0 11.2 12.5 14.0
Capacity kW
Heating 10.0 12.5 14.0 16.0
Installation Input power W 66 85 131 180
High 1,630 1,690 2,010 2,270
Open Concealed Wall mounted Airflow rate Med m3/h 1,370 1,400 1,600 1,780
(Field Supplied)
Low 1,140 1,170 1,230 1,280
High 42 45 48 51
Sound pressure dB
Med 38 38 42 45
level (A)
Low 33 34 35 36
Dimensions (H × W × D) mm 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700
Weight kg 46 48 48 48
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 19.05 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
General installation pattern Installation pattern where part Installation which fixes the indoor unit to the
Note : Specifications are based on the following conditions.
which suspends the indoor of the indoor unit is embedded wall by the use of wall brackets (Field supplied). Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
unit from the ceiling. into the ceiling. This type of installation can be used Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
when the ceiling space is insufficient.
low
air-f
nce
gd ista
Lon
5 steps selectable
High power DC fan motor
• High power • Wide rotation range • High efficiency
Up and down
3
1 Refrigerant piping flare connection (Liquid)
4 2 Refrigerant piping flare connection (Gas) 3
4 steps selectable 3 Drain piping connection 2 1 3
88 89
AIRSTAGE Indoor units TM
Models (EEV internal model) Though the indoor unit is compact, it features 790mm ensures that the air direction
corresponds to the mode selected.
a large, high pressure cross fan (90mm
ASHA07GACH diameter) in a centre mounted configuration
ASHA09GACH and a Lambda type heat exchanger to
ASHA12GACH provide plenty of power. 1
ASHA14GACH
2
Sw
3
ing
4
Step
Swing
Filter features
High quality air conditioning by incorporation of high performance
filter.
Deodorizing effect (Odor reduction rate) 790mm
Easy maintenance
Ammonia Trimethylamine
(ppm) (ppm) Easy maintenance
Ion Deodorization Filter 160 160 has been realized as the
With no filter
120
With no filter
120 New style high power DC fan motor front panel can removed
80 80 New filter for easy access.
The filter deodorizes by powerfully decomposing absorbed odors • High power Open panel
New filter
using the oxidizing and reducing effects of ions generated by the 40 40
• Wide rotation range
ultra-fine-particle ceramic. 0
0 30 60 120 (min)
0
0 30 60 120 (min)
• High efficiency
• Compact size
Hydrogen sulfate
(ppm)
Apple-catechin Filter 160
With no filter
120
Apple-catechin filter uses static electricity to clean fine particles 80 New filter Testing organization :
and dust in the air. 40 Environmental Sanitary Inspection Center
Symmetrical design
0 Test method :
0 30 60 120 (min) Symmetrical, clean design that suits all interiors.
Deodorization Test
275
Low 370/420*1 370/420*1 420 420
High 35 36 39 44
Sound pressure dB
Med 33 33 35 37
level (A)
Low 27/31*1 27/31*1 31 32
Dimensions (H × W × D) mm 275 x 790 x 215
Weight kg 9
470
Connection Liquid (Flare) 6.35 3
pipe diameter 530
Gas (Flare) mm 12.70
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7 660
EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts:
1 2
65
416 19
222 32
UPWARD
Vertical installation
Install the unit as confirmed direction.
wire
1 Refrigerant pipe flare connection (Liquid)
UPWARD wire
121
by more than 5°
Install the unit as confiremed direction .
97
Install the unit where it will not be tilted
65
OUTDOOR UNIT INDOOR UNIT
SIDE SIDE
90 91
AIRSTAGE Indoor units TM
Models
5 steps selectable
ASHA18GACH
ASHA24GACH
ASHA30GACH
4 steps selectable
Sw
provides powerful floor level heating directly at the occupants in the room
3 Step Ion Deodorization Filter
in g
Swing
4
2.5 2.5
33 32 31 30 29 15 16 17 18
o
46
Easy maintenance
Power diffuser (full open)
DC fan motor
998mm Simplification of drain pan cleaning improves
maintenance-ability.
92 93
AIRSTAGE Indoor units TM
Wall Mounted
Models
ASHA004GTAH
ASHA007GTAH
ASHA009GTAH
Specifications
Model name ASHA004GTAH ASHA007GTAH ASHA009GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8
Capacity kW
Heating 1.3 2.8 3.2
High efficient compact design Input power W 13 19 34
High 430 550 720
Ø5mm high density heat exchanger is mounted for the first time in the industry. Med-H 420 460 570
Med 390 420 500
Airflow rate m3/h
Med-L 380 390 410
Low 360 360 360
Quiet 330 330 330
High 31 35 43
High density heat exchanger Med-H 30 32 38
Sound pressure Med dB 28 30 34
Making the tube thin: level Med-L (A) 26 27 29
7 mm 5 mm Dimensions (H × W × D)
Low
Quiet
mm
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
Increase of heat exchanger volume
Weight kg 7.5 7.5 7.5
by high density and adopting sub
Connection Liquid (Flare) 6.35 6.35 6.35
heat exchanger pipe diameter Gas (Flare) mm 9.52 9.52 9.52
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - - -
Note : Specifications are based on the following conditions. When ASH*004GTAH, ASH*007GTAH, ASH*009GTAH are connected to the outdoor unit
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. other than J-IIIL, gas pipe diameter should be Ø12.70.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Med-H 262
Med
Med-L
Low
Quiet
Optimized design matches to a small room
* Compatible Remote Controller is as follows:
Efficient operation and refrigerant saving are realized by optimum
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 heat exchanger design suited for small rooms.
94 95
AIRSTAGE Indoor units TM
Wall Mounted
Models
ASHA012GCAH
ASHA014GCAH
Specifications
Model name ASHA012GCAH ASHA014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.0
Capacity kW
Heating 4.0 4.5
High efficient compact design Human sensor increases Input power W 25 36
High efficient compact design is realized by mounting a high density more energy saving High
Med-H
690
610
800
740
and large heat exchanger. Med 560 680
Energy saving operation starts automatically by Airflow rate m3/h
Compact body makes it possible to install inconspicuously even in a Med-L 530 610
detecting the motion of a person. 2 modes of save
meeting or office room and comfortable air conditioning is provided. Low 470 550
operation mode and stop mode can be selected. Human sensor
Quiet 330 330
High 40 44
People go out. People come back. Med-H 37 42
Sound pressure Med dB 35 40
level Med-L (A) 33 37
Low 30 34
Quiet 24 24
Dimensions (H × W × D) mm 268 × 840 × 203 268 × 840 × 203
Weight kg 8.5 8.5
Connection Liquid (Flare) 6.35 6.35
pipe diameter Gas (Flare) mm 12.70 12.70
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - -
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
High density heat exchanger
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Even temperature 6 Fan Speed Control
7 mm 5 mm
Making the Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
tube thin: Fan speed Low noise
Multistep airflow control
Increase of heat exchanger volume by high
density and adopting sub heat exchanger
Improved
heat exchanger is possible to suit the Quiet 24 dB(A) Dimensions (Unit: mm)
effectiveness
environment.
6-Step Speed
High
Heating Low
Vertical airflow provides Quiet
powerful floor level heating
268
* Compatible Remote Controller is as follows:
Power diffuser UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1
Cooling
Horizontal airflow does not blow
cool air directly at the occupants
Optional parts
in the room. Wired Remote Controller: UTY-RNRGZ2, UTY-RLRG
Wireless Remote Controller: UTY-LNHG
Power diffuser
Simple Remote Controller: UTY-RSRG, UTY-RHRG
96 97
AIRSTAGE Indoor units
TM
Wall Mounted
Models Models
ASHA18GBCH ASHA030GTAH
ASHA24GBCH ASHA034GTAH
ASHA18 ASHA24
ASHA030 ASHA034
Specifications
Model name ASHA18GBCH ASHA24GBCH ASHA030GTAH ASHA034GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0
Capacity kW
Heating 6.3 8.0 10.0 11.2
Powerful & Comfort airflow Input power W 32 60 74 103
High 840 1,100 1,440 1,620 / 1,520
Powerful Airflow Power diffuser
Med-H - - 1,200 1,300
(ASHA030GTAH) (ASHA18/24GBCH) Med 770 910 1,050 1,120
Airflow rate m3/h
Med-L - - 940 980
Vertical airflow Horizontal airflow Low 690 730 890 890
(24) (24) Quiet - - 700 700
High 41 48 53 55 / 54
Med-H - - 49 51
Airflow Sound pressure Med dB 39 43 45 47
320
340
Drastic low noise is realized by new
airflow structure. In addition, multistep -2 dB(A) High
25
Low
Quiet
1 Refrigerant piping flare connection (Liquid)
Current model New model 2 Refrigerant piping flare connection (Gas)
* Compatible Remote Controller is as follows:
(030/034class) UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 3 Drain piping connection
98 99
User friendly control system
provides individual control to centralized control
The AIRSTAGE control system can perform air conditioning control of individual
application, such as linking with the building control system, linking with a single split
AIRSTAGE
TM
CONTROL SYSTEM
CONTROL SYSTEMS
CONTROL SYSTEM OVERVIEW
INDIVIDUAL CONTROLLER
CENTRALIZED CONTROLLER
CONVERTOR / ADAPTOR
100 101
AIRSTAGE Control Systems TM
SHOP OFFICE
Individual Individual
Type Control
Centralized Control Integrating Control (Interface) Type Control
Centralized Control Integrating Control (Interface)
WHITE-USB-KEY
(Software Protection Key)
UTY-RNRGZ2, UTY-APGXZ1, UTY-VMSX, UTY-VKGX, UTY-RNRGZ2, UTY-RSRG, UTY-APGXZ1, UTY-ABGXZ1, UTY-VMSX UTY-VKGX
UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-VLGX UTY-LNHG UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-VLGX UTY-TERX
UTY-RLRG UTY-ALGXZ1 UTY-VMGX UTY-VKSX UTY-RLRG UTY-RHRG UTY-ALGXZ1 UTY-VBGX UTY-VMGX UTY-VKSX
WHITE-USB-KEY
Remote Management
102 103
AIRSTAGE Control Systems
TM
User’s needs are supported by offering a variety of controls, such as individual control,
central control and building management control options.
BACnet® Gateway
(Field supplied)
Max. controllable UTY-VBGX Hardware
Wired Remote Controller
UTY-RNRG System Controller Software 1600
Indoor units
*
BMS/BAS *2
UTY-APGXZ1 / UTY-ALGXZ1 (Lite edition) Network Convertor
(BMS/LONWORKS®)
*: Lite edition is max. controllable 400 indoor units
Remote/ UTY-VLGX
Monitoring side
Simple Remote Controller
UTY-RSRG Internet or MODBUS® Convertor
UTY-RHRG Public
Without operation mode Telephone UTY-VMGX
Line
BMS, Home automation system
Max. controllable MODBUS® Convertor For indoor unit
Wireless
Remote Controller Touch Panel Controller 400
Indoor units
UTY-VMSX
or
UTY-DTGGZ1
UTY-LNHG
MODBUS® Interface
FJ-RC-MBS-1 *1. USB Adaptor: Echelon® U10 USB Network Interface
Central Remote *2. BMS/BAS: Building Management System/Building Automation System
Max. controllable
Controller
IR Receiver Unit
UTB-YWC For Duct type
UTY-DCGG 100
Indoor units KNX® Convertor For VRF
UTY-LRHGB1 For Cassette type UTY-VKGX
For Duct For Cassette
104 105
AIRSTAGE Control Systems TM
Type
Wired Remote Controller System Controller Lite System Controller
Wired Remote Controller Simple Remote Controller Simple Remote Controller *1 Wireless Remote Controller Group Remote Controller Central Remote Controller Touch Panel Controller
(Touch panel)
Model name UTY-RNRGZ2 UTY-RLRG UTY-RSRG UTY-RHRG UTY-LNHG UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-ALGXZ1 UTY-APGXZ1
Max. controllable remote controller groups 1 1 1 1 1 8 100 400 400 1600
Max. controllable indoor units 16 16 16 16 16 128 100 400 400 1600
Max. controllable groups — — — — — — 16 400 400 1600
On / Off
Operation mode setting —
Fan speed setting
Room temp. setting
Air conditioning control function
Cooling/heating priority —
Address display —
Room temp — — — — — —
Multi language — — — — —
Summer time — — — — —
Name registration — — — — —
Backlight — — — — —
2D floor layout / 3D building display — — — — — — — — —
Period Week Week — — — Week Week Year Year Year
Schedule
timer On/off, Temp,
8 4 — — — 4 20 20 144 144
Mode, Times per day
Timer
On/off timer — — — — — — —
Sleep timer — — — — — — — — —
Program timer — — — — — — — — —
Auto off timer — — — — — — —
Day off — — — —
Min. unit of timer setting (Minutes) 10 • 30 30 — — 5 10 10 10 10 10
Status monitoring system — — — — — —
Electricity charge apportionment — — — — — — —
Error history — — —
Emergency stop — — — — — — *2 *2 — —
Control
Remote management — — — — — — —
Energy saving management — — — — — — — —
E-mail notification for malfunction — — — — — — —
Key lock
— — —
Child lock Child lock Child lock Password setting Password setting Password setting Password setting
*1 “Operation mode” setting is not available for this model. *2 This function is available only through external input control. : Supported : Optional function — : Not supported yet
106 107
AIRSTAGE Control Systems Individual Controller
TM
Wired Remote Controller (Touch Panel) Various energy saving control Simplified installation
Max. controllable
• Maintains 2 separate set points for heating and cooling. • The faulty wiring can be prevented by using non-polar 2-wire.
UTY-RNRGZ2 • Automatically changes mode between heating and cooling.
* This function is not available for some models.
Easy operation by high-definition large STN-LCD touch panel screen I.U. Y1Y2 Y3 I.U. Y1Y2 Y3
Cooling set temp. 27˚C, Heating set temp. 26˚C
• Easy finger touch operation with LCD panel
• Built-in weekly/Daily timer (ON/OFF, Temp., Mode)
• Backlight enables easy operation in a darkened room
• Room temperature display non-polar
Auto 2-wire
• Control up to 16 indoor units
Operation Start
Changeover
• Corresponds to 12 different languages
Change over
(English, Chinese, French, German, Spanish, Russian, Polish, Italian, Greek, Portuguese, Turkish and Dutch) OK OK
Cooling Set Point
• 2-wire type
Heating Set Point
Change over
High performance and compact size Various convenient functions • The indoor unit automatically is turned off when it reaches to the
preset operating time frame.
• In addition to the individual control, various energy saving controls Displays setting status and Limitations • The time frame of the “Auto off timer” can be flexibly scheduled.
can be realized using one remote controller only. • Can be set off time 30 to 240 minutes
• The remote controller settings can be
easily checked
Individual Thermo Weekly Auto off
control sensor timer timer
Auto Address Setting/Setting Position Notification
Set interval time (17:00 to 24:00) • Reduce errors and install time compared with the current
specification Rotary SW
ON OFF ON Auto OFF ON Auto OFF • When will be set remote controller groups, can also be set
automatically new Wired remote controller address
Accurate and comfortable control 1 hour 1 hour • After auto address setting of new wired remote controller groups,
what number can also confirm addresses
• Indoor temperature can be detected accurately by the inclusion of a Normal Time Over Time Address → 04 03 02 01
thermo sensor in the body of the wired controller.
8 17 24
Ex.) At interval time hour (17:00 to 24:00) to prevent forgetting to turn off
Summer Time display Set off time : 1 hour The appropriate indoor unit
performs the air blow and
• This function can be set easily from 2 schedules Weekly Timer LED lamps blink.
Menu screen
• 2 schedules such as for the summer and winter can be set.
• 8 setting changeable per day of week (Setting items: On/Off, 05
Temperature, Mode, Time)
Ex)
Easy Maintenance
Error History Display
• The errors that occur in the indoor unit or
Child lock
remote controller are saved as a history.
• Lock / unlock method: Push the ON/ • A maximum of 32 error incidents can be
OFF button and the screen (4 seconds) saved.
Set Temperature Auto Return
• The setting temperature automatically returns to the previous
setting temperature.
• The time range in which the set temperature can be changed is 10 to
120 minutes.
Room temperature sensor Room temperature
display Set Temperature Upper and Lower Limit Setting
• The set temperature range can be set for each operation mode.
Name Registration
(Cooling / Heating / Auto).
Backlight • Remote controller names can be Initial Setting Page 1/ 3
108 109
AIRSTAGE Control Systems Individual Controller
TM
16 16
indoor units indoor units
UTY-RLRG UTY-RSRG
UTY-RHRG (Without Operation mode)
• Various timer setup (ON / OFF / WEEKLY) are possible.
• The room temperature can be controlled by detecting the temperature accurately with Built-in thermo sensor.
• When a failure occurs, the error code is displayed. Compact remote controller provides access to basic functions
• Error history. (Last 16 error codes can be accessed.)
• Up to 16 indoor units can be controlled with one remote controller.
• 2-wire type
• Suitable for hotels or offices as it is easily operated with no complex functions.
• Stylish design: Simple design to match the stylish interior.
• Large LCD screen & simple operation buttons
• Backlight: White colored backlight on monitor enable easy operation in dark.
• 2-wire type
UTY-RSRG UTY-RHRG
Without Operation mode
Functions Functions
High performance and compact size High visibility and Corresponding to various applications
In addition to the individual control, weekly timer, and various energy easy operation • Vertical louver control:
saving controls can be realized using only one remote controller. • “Mode”, “Set Temp”, and “Fan” are Vertical air flow direction can be adjusted for Duct types with
displayed at large size on the top screen. auto louver and Cassette types, which are installed in hotels and
• Each function to be set is indicated by conference rooms, can be adjusted.
Individual Thermo Weekly Auto OFF an icon. Sophisticated control buttons
control sensor timer timer Simple operation with easy
• Control guide is displayed and operation
4-way navigation pad
is simple and straightforward.
Set contents can be displayed
clearer with large LCD.
Weekly timer function Set temperature upper and lower limit setting
• Not only time setting On / Off, but also setting of the operation • The set temperature range can be set for each operation mode.
Room temperature
mode and set temperature can be set by Weekly timer function. (Cooling / Heating / Auto)
sensor
ON OFF ON OFF During Cooling During Heating
24°C 30°C 30°C
25°C
Working hour Working hour 25°C
Specifications Specifications
Model name UTY-RLRG Model name UTY-RSRG UTY-RHRG
Power Supply DC 12V Power Supply DC 12V
Dimensions (H x W x D) mm 120 × 120 × 17 Dimensions (H x W x D) mm 120 × 75 × 19.4
Weight g 170 Weight g 120
DC12V is supplied by indoor unit. DC12V is supplied by indoor unit.
110 111
AIRSTAGE Control Systems Individual Controller
TM
16 4
indoor units daily timers
UTY-LNHG UTB-YWC
Simple and sophisticated operations Necessary to control for all Duct types* by Wireless Remote Controller
with a choice of 4 daily timers *Only Large Airflow Duct can not be connected to IR Receiver Unit.
• A single controller controls up to 16 indoor units. • Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.
Functions
Wiring connection
Functions
T imer setting
60min.
IR Receiver Unit
Address setting UTY-LRHGB1
2˚C
1˚C During installation work, address setting can be performed using the
Wireless Remote Controller, thus eliminating manual switch setting. Cassette type indoor unit can be controlled
with Wireless Remote Controller
Heating operation
Transmission line
When the sleep timer is set, the set temperature automatically drops
1˚C every 30 minutes. The set temperature can drop to a max. of 4˚C.
Indoor unit
Outdoor unit
1˚C
2˚C
Functions
3˚C Wireless
4˚C Remote Controller
30min.
60min.
90min.
T imer setting Wireless
Remote Controller
Specifications Specifications
Model name UTY-LNHG Model name UTY-LRHGB1
Power Supply 1.5V (R03 / LR03 / AAA) × 2 Power Supply DC 5V
Dimensions (H x W x D) mm 170 × 56 × 19 Dimensions (H x W x D) mm 193.9 × 193.9 × 31.2
Weight g 85 Weight g 140
112 113
AIRSTAGE Control Systems Centralized Controller
TM
8 64 100 16
remote controller group R.C. in a VRF indoor units groups
groups network system
UTY-CGGG UTY-DCGG
Group control of indoor units with simple operation Central control of small- and medium-sized buildings and tenants. The operation
• Up to 8 remote controller groups can be controlled by one Group Remote Controller.
status of all connected indoor units can be viewed at a glance on a large LCD monitor
• Up to 64 Group Remote Controllers can be connected in one VRF network system. to simplify individual control to batched control.
• Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers
to a VRF network system. • Individual control and monitor of 100 indoor units
(Network Convertor allows up to 4 Group Remote Controllers) • 5 inch TFT color screen
• User friendly view and easy operation
• External input / output contact
• Detachable power supply unit
• Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)
Functions Functions
Group : 3F
Single Group Remote Controller controls and monitors up to 8 remote controller groups. • It allows multiple indoor
Group : Division A Group : Division B Group : Division C
units grouping (Max.16
Refrigerant Refrigerant groups controlled)
system 1 system 2 • Interlock with external
device
Hotel Group : 2F
Restaurant
Lounge
Functions
Office room
• Diverse control of indoor units • Remote controller prohibition • Weekly timer • Error history • Automatic clock adjustment
Network (All, On / Off, Mode, Temp, Timer, Filter)
Lobby Convertor
Group Remote Controller 1:
To control office room, lounge,
Restaurant restaurant and lobby
(8 remote controller groups)
Easy Installation
• The control panel and power supply unit can be installed separately. • Automatic or manual indoor unit registration
• For flexibility in installation, the Control panel can be built into the
High performance and compact size Built-in weekly timers wall or fix on the wall. Indoor unit registration
ON / OFF, Operating mode, Room temperature and Fan speed setting The weekly timer is provided as a standard function. Setting pattern 1 Setting pattern 2
can be controlled / monitored centrally or individually. 1. The timer can be set up for up to 4 times per day. Ceiling
Indoor unit registration
start
(On / Off, operating mode, set temperature) Power supply unit
Power supply unit
Central ON/OFF Weekly 2. Allows separate settings for each day of the week.
control control timer Control panel Wall Control panel
Specifications
Model name UTY-DCGG
Control Panel Power Supply Unit
Specifications
Power Supply DC 5 V 100-240V, 50-60Hz, Single phase
Model name UTY-CGGG Dimensions (H x W x D) mm 120 x 162 x 25.7 99 x 135 x 39.2
Power Supply DC 12V Weight g 308 355
Dimensions (H x W x D) mm 120 × 120 × 18 <PACKING LIST>
Weight g 200 Packing List Control Panel / Power Supply Unit / Connecting cable, etc.
DC12V is supplied by indoor unit.
114 115
AIRSTAGE Control Systems Centralized Controller
TM
400 100 400 • Control and monitor Fujitsu’s air conditioner via LAN or Internet.
indoor units outdoor units groups
• Allow user or tenant to manage only assigned equipment by their PC or tablet from anywhere.
UTY-DTGGZ1 • Error contents are notified automatically by E-mail at error occurrence to handle the trouble promptly.
Functions PC
Staff / Employee
Group A
Additional languages function
Group B
Corresponds to 7 different languages, English, Chinese, French, Monitoring from web site
German, Spanish, Russian, Polish as standard.
Additional language can be integrated on remote device by
creating language database.
It allows multiple indoor unit grouping
Additional language is displayed on only the remote device, and
Write
Touch Panel Controller cannot be added other languages.
116 117
AIRSTAGE Control Systems Centralized Controller
TM
Providing function Automatic clock adjustment Anti freeze setting Electricity charge apportionment
Display
Key lock -
Error Password setting
Current time
Day of week
Cooling/heating priority
Users can choose from 4 low noise levels, depending on the installation Quiet priority setting
environment. Address display
Air
The operaion time can be set using the timer. conditioning Room temp
load factor Heat load
Multi language
100% down Summer time
Capacity
0 Time zone setting
Block (Tenant) A
Operating 58dB Name registration
sound
0 Backlight
Block (Tenant) B
time
Quiet priority low noise mode Language setting 7 7+other
118 119
AIRSTAGE Control Systems Centralized Controller
TM
VRF Network
Click & Operate the whole building ! Properties can be shown using one of the four Click & Operate any specified unit(s)!
displays of site, building, floor, or list.
Remote controller prohibition Data base import/export
This prohibits changes to the operation mode, temperature, Imports/exports registration data, layout data, and image data.
start/stop, etc. Only the administrator can make this setting.
The display is easily changed by pressing the button.
Web Operation
PC and smartphones can be used as
simple remote controller.
Batched control of freely WAN*1 (Intranet)
defined groups (Indoor unit user setting is necessary to ON/OFF
operate it from System Controller side) Temperature setting
Check remaining amount*2
Wi-Fi LAN (Intranet)
Batched control of freely selected units Mode setting
HUB
Fan speed
Building view Louver setting
Wireless LAN access point System Controller
*2: prepaid AC function
The floor layout drawing
Note: can be imported to easily
2D floor layout / 3D building make the settings for the PC
display are not available for Click & Operate the whole floor ! actual building.
System Controller Lite. *1:For connection via the Internet, the following setting is necessary.
Floor view ・Fix IP address (or similar)
Click & Operate the unit !
Batched control of freely selected units ・Open the router’s port of No.80.
120 121
AIRSTAGE Control Systems Centralized Controller
TM
charge apportionment function, used energy apportionment ratio will be System Controller Number of floor per 1 site
Number of floor per 1 building
200
50
-
-
-
-
-
-
-
-
-
-
-
-
Site
provided, calculating in detail the energy consumed by the units used by Power supervision
3D graphical layout view - - - - - -
distribution 2D graphical layout view - - - - - -
each tenant. This information is then used to calculate the charges for the board
Tenant A-1 Tenant A-2 Tenant A-3
List display - - - - -
electricity consumed for air conditioning by each tenant from the total Tree display
Group display
-
-
-
-
-
-
-
-
-
-
Power
electricity charges in the bill from the electric power company. (See figure distribution Error
Error notification - - - - -
Outdoor Tenant A-4 Tenant A-5 Tenant A-6 Audible alarm - - - - -
board
at right) unit
management
Error e-mail notification - - - - -
The detailed calculation takes into consideration such things as unused History
Error history
Operation history
-
-
-
-
-
-
-
-
-
-
rooms and nighttime electricity charges and shows them in a charges Control history - - - - -
Tenant B-1 Tenant B-2 Tenant B-3 On/Off - - - - -
calculation sheet. Operation mode - - - - -
Room temperature - - - - -
Fan speed - - - - -
3Ø, 4 wire 400V, 50Hz Individual Air flow direction - - - - -
Tenant C-1 Tenant C-2 Tenant C-3 1Ø, 2wire 230V, 50Hz control Economy mode - - - - -
Room temperature set point limitation - - - - -
Operation Test operation - - - - -
control Antifreeze - - - - -
Outdoor unit low noise setting - - - - -
Remote control prohibition setting - - - - -
Individual
Remote management
Temperature upper and lower limit setting - - - - -
for System Controller for System Controller Lite UTY-PLGXA2 management
Filter sign reset - - - - -
Memory operation - - - - -
Other Pattern operation - - - - -
System Controller may be used on site or remotely Remote central control Remote central control Web operation - - - - -
over various networks for remote central control. 1 VRF Controller can be monitored from any number 1 VRF Explorer can control or monitor up to 10 sites. Annual Schedule - - - - -
of VRF Explorers (Up to 5 connections simultaneously). Special day setting - - - - -
System Controller requires On /off per day 72 - 72 - - - -
Schedule On / off per week 504 - 504 - - - -
2 softwares working together. VRF Controller runs VRF Explorer Building Management Company A
(In charge of the day shift)
VRF Explorer
Day off - - - - -
VRF Explorer VRF Controller Building management company,
on site and communicate with VRF system. VRF VRF Explorer
A maximum of
management center, etc. Min. unit of timer setting (Minutes) 10 - 10 - - - -
10 locations, such as Low noise mode Weekly schedule - - - - -
Explorer runs remotely and provides user interface offices or factories
Remote monitoring - - - - -
Building
and communicate with the VRF Controller. VRF Management Company B
(In charge of the night shift) Internet
or
Office Management Center
Remote
managemment
Remote operation control
Remote function setting
-
-
-
-
-
-
-
-
-
-
Controller and VRF Explorer program may run in a VRF Explorer
Telephone Line
or
LAN
VRF Controller Internet
or
Web Remote Controller - - - - -
Telephone Line Apportionment charge/bill calculation - - - - -
single PC or in different PCs separated by network. or
LAN Tenant (block) setting - - - - -
Electricity
By using VRF Explorer software, one PC can Security Company
VRF Explorer
charge
Common facilities apportionment setting
Rated power consumption allotment setting
-
-
-
-
-
-
-
-
-
-
apportionment
perform central control of 10 VRF system sites with Headquarters
Management Center
Individual calculation at cooling and heating - * - - - -
Electricity meter supported - - - - -
max. 20 buildings per site. Indoor unit rotation - - - - -
Peak cut control - - - - -
Energy Outdoor unit capacity save - - - - -
saving Record of energy saving operation - - - - -
management Energy saving information - - - - -
Power consumption monitor - - - - -
Energy saving management
for System Controller UTY-PEGX for System Controller Lite UTY-PLGXE2 Electricity meter supported - - -
External Device Monitor - - - - -
Control Control - - - - -
saving operation is performed while keeping users comfortable. A power meter is connected to detect the total power consumption : Available. - : Not available. *:Power calculation application software is necessary, please contact the local FGL representative.
while shifting the indoor unit set temperature, set the indoor unit
forced thermostat off, and taking other measures to carefully control
the power consumed while Personal computer system requirements
Forced thermostat off range
maintaining comfort and The required PC specifications are shown in the following table.
Outdoor unit stop range Target power consumption
conducting control to System Controller System Controller Lite
maintain the target power • Microsoft® Windows® 7 Home Premium (32-bit or 64-bit) SP1, Windows® 7 Professional (32-bit or 64-bit) SP1
Energy saving graph data:
consumption set for each Operating system
• Microsoft® Windows® 8.1 (32-bit or 64-bit), Windows® 8.1 Pro (32-bit or 64-bit)
This graph compares the electricity • Microsoft® Windows® 10 Home (32-bit or 64-bit), Windows® 10 Pro (32-bit or 64-bit)
consumption with the previous month time. The indoor units to Ideal control line [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish
and previous year to make it easy to be controlled can be freely (Use of average
power consumption) CPU Intel® CoreTM i3 2 GHz or higher
analyze the energy saving effect. grouped and the control Memory • 2 GB or more (for Windows® 7 [32-bit]) • 4 GB or more (for Windows® 7 [64-bit], Windows® 8.1, and Windows® 10)
Energy Saving Management Main Screen level can be set. Shows change in power consumption by time
HDD 40 GB or more of free space355
Display 1024 x 768 or higher resolution
•Ethernet port (for getting access to the Internet using LAN) or •Ethernet port (for getting access to the Internet using LAN) or
Indoor unit rotation operation Outdoor unit capacity save Modem (for getting access to the Internet using Public Telephone Line) Modem (for getting access to the Internet using Public Telephone Line)
•USB ports (Maximum of 6 ports) •USB ports (Maximum of 6 ports)
The operation of indoor units can be automatically rotated within a Outdoor unit capacity save switches the outdoor unit capability upper Interface (Required only for the Server PC that works as VRF Controller) (Required only for the Server PC that works as VRF Controller)
- Maximum of 2 USB ports are required for WHITE-USB-KEY/WibuKey connection - Maximum of 4 USB ports are required for WHITE-USB-KEY/WibuKey connection
group in accordance with the set annual schedule to reduce power limit to suppress power consumption during hot summers and cold - Maximum of 4 USB ports are required for Echelon® U10 USB Network Interface - 1 USB port is required for Echelon® U10 USB Network Interface
consumption while maintaining comfort. The indoor unit operation winters by averaging the power saving effect of each refrigerant * Maximum number of required USB port depends on the applicable system configuration. * The maximum number of required USB port depends on the applicable system configuration.
stoppage rate can be selected. system. You can select from 50% or more of the capacity upper limit. Graphic accelerator Microsoft® DirectX® 9.0c compatible
Software Adobe® Reader® 9.0 or later
Outdoor unit • Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)re.
Hot day of
Power consumption
122 123
AIRSTAGE Control Systems Convertor / Adaptor
TM
UTY-ABGXZ1 UTY-VBGX
• It is possible to connect medium to large sized BMS to VRF network system via BACnet®, a global standard for open networks. • BACnet® Gateway enables to connect a BMS and FG VRF system.
• A maximum of 1600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 100 outdoor units for one network • A maximum of 128 indoor units and 32 refrigerant system can be connected to a single BACnet® Gateway.
system) can be connected to one BACnet® Gateway. WHITE-USB-KEY • Compatible with BACnet® (ANSI / ASHRAE-135-2010) application specific controller (B-ASC).
• It is possible to control or monitor VRF network system from BMS via BACnet® Gateway. (Software Protection Key) • Compatible with BACnet®/IP over Ethernet.
• Compatible with BACnet® (ANSI / ASHRAE-135-2012) application specific controller (B-ASC).
• Compatible with BACnet®/IP over Ethernet.
• Scheduling function, Alarm & Event functions as well as Electricity Change Apportionment function are provided in BACnet® Gateway.
• Connection between VRF network system to personal computer is possible via small U10 USB interface. However, both U10 USB
Functions
interface & personal computer are field supplied items.
• Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
Installation example
Max.128 indoor units &
Max.32 refrigerant system
Security system
BACnet® Operator
Workstation (B-OWS) Automatic fire alarm interface
VRF network system 1 BACnet®
®
BACnet BACnet ® Operator
Windows bind VRF Outdoor unit
Lighting facilities Number of controllable indoor units 128 Power Supply 208-240V 50/60Hz, single phase
Number of controllable refrigerant system 32 Power Consumption W 4.6 (max)
VRF network system 2
Number of controllable VRF network 1 Dimensions (H x W x D) mm 59.6 × 270.4 × 176
Security system Number of connectable units / one VRF etwork 4 Weight g 1,200
USB adaptor
(Field supplied)
BACnet® Gateway Automatic fire alarm interface
Indoor unit Outdoor unit (UTY-ABGXZ1)
124 125
AIRSTAGE Control Systems Convertor / Adaptor
TM
9 128 100 1
units to one VRF indoor units outdoor units Single indoor unit
UTY-VMGX FJ-RC-MBS-1
The MODOBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. The Modbus Interface allows a complete integration of
• Compact and lightweight design
air conditioners into Modbus Networks.
• Direct connection to MODBUS Network • Simple installation due to small and compact size.
• Up to 128 indoor units can be controlled in one MODBUS Convertor • No separate external power supply required.
• The MODBUS Convertor permits central monitoring and control of air conditioners from BMS or Central Controller. • The Modbus Interface permits central monitoring and control of air conditioners from BMS.
Functions Functions
Max. 63
Modbus Network
MODBUS Network Modbus Interface The Modbus Interface can be used with
VRF System (Lon Network) or without Wired Remote Controller.
BMS/Central
Controller
Controller VRF Indoor unit
MODBUS Convertor
BMS/Central Lighting facilities
for VRF VRF Indoor unit VRF Indoor unit
Controller Security system
VRF Indoor unit
Automatic fire alarm interface VRF Outdoor unit
Windows bind
* BMS : Bulding Management System Wired Remote
Controller Split Indoor unit
Specifications
Model name UTY-VMGX
Specifications
Power Supply 220-240V 50/60Hz
Input power W Max. 2 Model name FJ-RC-MBS-1
Dimensions (H x W x D) mm 54 × 260 × 150 Dimensions (H x W x D) mm 93 × 53 × 58
Weight g 1,100 Weight g 85
1 1
Single indoor unit group
UTY-VMSX FJ-RC-KNX-1i
The MODBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. The KNX Interface allows a complete integration of air
• Simple installation due to small and compact size.
conditioners with KNX Network systems.
• No separate external power supply required. • Simple installation due to small and compact size.
• The MODBUS Convertor must be connected one by one in the indoor unit. • No separate external power supply required (just KNX bus power).
• The MODBUS Controller permits central monitoring and control of air conditioners from BMS/Central/Home Controller. • Can be used for single indoor units and group controlled (up to 16) indoor units
Functions Functions
Specifications
Model name UTY-VMSX Temperature Operating / Packaged ºC 0~46 / -10~60
Specifications
Power Supply DC12V Humidity Operating / Packaged % 0~95 / 0~95
Input Power W Max. 1.2 Maximum Connectable indoor unit number Model name FJ-RC-KNX-1i
1
Dimensions (H x W x D) mm 140 × 117 × 43 per 1 MODBUS Convertor Dimensions (H x W x D) mm 70 × 70 × 28
Weight g 200 Weight g 70
126 127
AIRSTAGE Control Systems Convertor / Adaptor
TM
128 100 1
indoor units outdoor units Single indoor unit
UTY-VKGX UTY-TFSXZ1
It is possible to control the VRF system from central / home controller via KNX network. • It is the most advanced solution to remotely manage an Air Conditioning system using
all sort of mobile devices such as Smartphones, and tablets.
• New KNX Convertor enables to connect central/home controller and FG VRF system. • No separate external power supply required
• A maximum of 128 indoor units and 100 outdoor units can be connected to single KNX Convertor. • Can be used for single indoor units and multi system indoor units
Functions
Functions
Central / Home
Registrable Download Free
Controller
128 indoor units
100 outdoor units
Wireless LAN
Specifications Interface
Router
Smartphone (Locally purchased)
Smartphone
1
Single indoor unit
Router
(Locally purchased)
Indoor unit
Central / Home
Controller
KNX Convertor
Multiple air conditioning management
for indoor unit Outdoor unit Smartphone • Multiple air conditioning management at difference locations.
Specifications
Model name UTY-VKSX
Specifications
Power Supply (DC12V)
Input power W 0.6 Model name UTY-TFSXZ1
Dimensions (H x W x D) mm 140 × 117 × 43 Dimensions (H x W x D) mm 71 × 38 × 15
Weight g 250 Weight g 85
128 129
AIRSTAGE Control Systems Convertor / Adaptor
TM
1 16 100
Single indoor unit single indoor units Network Convertors
UTY-VTGX UTY-VTGXV
DC power supply type AC power supply type
Functions Functions
Installation example
• 2 types of 1 remote controller type and 2 remote controllers type are available.
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote controllers type.
Indoor unit
Internet Smartphone
Basic control
• Turning the units on and off • Room temperature display (Application screen image)
• Mode control (Heat, Cool, Dry, Auto, Fan) • Set temperature control
• 2-wire and 3-wire type of the wired remote controller can be • A central control can be provided for the single split systems. (Up to
• Fan speed setting • Multi Language
connectable. 100 units of Network Convertor is connectable in one VRF network
• Louver position (Airflow direction setting) • One Scene and Timer
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote system)
controllers type.
Up to 100 units of
Network Converter
Specifications
Model name UTY-VTGX UTY-VTGXV
Specifications
Power Supply polar 3-wire DC12V non-polar 2-wire DC12V 220-240V 50/60Hz, Single phase
Model name FJ-RC-WIFI-1 Input power W Max. 1.2 Max. 3
Dimensions (H x W x D) mm 108 × 70 × 28 Dimensions (H x W x D) mm 140 × 117 × 43 54 × 260 × 150
Weight g 80 Weight g 250 1,100
130 131
AIRSTAGE Control Systems Convertor / Adaptor
TM
16 4 1
single indoor Group Remote group
units Controllers
UTY-VGGXZ1 UTY-TERX
• This Network Convertor is to be used for connecting single split system or • In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the
Group Remote Controller (UTY-CGGY / UTY-CGGG) with the VRF network system. ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations
• Please select the function by switching the dip switch during the installation. such as hotel rooms.
• Card-key or other sensor switches are available as a locally purchased parts.
• 2-wire type
• The set temperature can be specified at two points for cooling and heating individually (4 points).
Functions
Installation example
Human sensor catches movements of
Functions people in a room, and operates with lower
capacity when people come back to the
SAVE ! AUTO RESTART
room, it automatically returns to previous +2°C *Max. 30°C
Used for connecting single split system operation mode.
Cooling/Dry
Set temp. Human sensor equipment needs to be
Network Convertor purchased locally. The above example
• Split type systems can be centrally controlled from Touch Panel Heating indicated that a signal is sent to this
Controller or System Controller through connection to the VRF’s Set temp. -4°C *Max. 16°C External Switch Controller if human
sensor does not detect for 20 minutes.
network convertor. Human sensor is not mounted on the
• On / Off Control, Master control, Room temperature and Fan speed Normal operation Saving operation Normal operation External Switch Controller.
setting via the Network Convertor are available.
• One Network Convertor can be used to connect and control up to 16
Specifications
single units. Group of Single Split
Single Split
Model name UTY-TERX
Power Supply DC 6.5-16V
VRF network system Dimensions (H x W x D) mm 140 × 117 × 43
USB Weight g 250
Adaptor
DC12V is supplied by indoor unit.
System Controller
Big Multi
Signal Amplifier
Please consult your distributor for connectable split type air conditioner.
Up to 100 Network Convertors may be connected in single VRF network system.
One Network Convertor is considered as a single refrigerant system,
irrespective of the number of connected single models.
UTY-VSGXZ1
Used for connecting • Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers.
• Up to 40 signal amplifiers can be installed in a VRF network system.
Group Remote Controller • A signal amplifier is required,
4 Group Remote Controllers can be connected to a single Network (1) When the total wiring length of the transmission line exceeds 500m.
Group (2) When the total number of units on the transmission line exceeds 64.
Convertor (UTY-VGGXZ1). Remote Controller
UTY-CGGY
UTY-CGGG
Functions
Installation example
Network Convertor
B
VRF network system
C
* 2 refrigerant circuits can be covered by a single Network Convertor (UTY-VGGXZ1) .
Up to a total of 16 Network Convertors (UTY-VGGXZ1) and System Controller
A D
adaptors can be connected in a single VRF network system.
Signal Amplifier
Specifications Specifications
Model name UTY-VGGXZ1 Model name UTY-VSGXZ1
Power Supply 208-240V 50/60Hz, Single phase Power Supply 208-240V 50/60Hz, Single phase
Input power W 8.5 Input power W 4.5
Dimensions (H x W x D) mm 67 × 288 × 211 Dimensions (H x W x D) mm 67 × 288 × 211
Weight g 1,500 Weight g 1,500
132 133
EFFECTIVE FRESH AIR TREATMENT
To facilitate the use of third party air handling units of various cooling capacity range
VENTILATION
Outdoor Air Unit
DX-Kit for airhandling applications
134 135
Ventilation
One VRF system can provide air conditioning and air supply at the same time. High speed
(Constant)
High speed
(Constant)
Outdoor Air Unit can be connected in a same VRF*1 system as one AC Motor
of indoor unit series and can create fresh and comfortable air supply
together from our high advanced technology. VRF system Damper opening small (Field supplied) Damper opening large (Field supplied)
Duct Group Central Touch Panel System Controller
Remote Controller Remote Controller Controller System Controller Lite
*1. Connectable VRF series:J-IIS, J-II, V-II, V-lll, J-lll, J-lllL (Software)
In J-II series alone, OAU is prohibit to connect under
the ambient temperature of Indoor unit Indoor unit
40°C or higher.
Top class compact design * The temperature setting is discharged air temperature setting.
Fan The air volume is set to a constant speed.
Heat
• Top class lightweight compact design at just 425 mm in height,
Exchanger 55 kg in weight for ARXH072 type. This unit can be installed
Outdoor Air Unit Fresh Fresh
Air Air easily even at narrow space.
Outdoor Air
Unit
1367 mm
Wired R.C. Wired R.C. Wired R.C.
* Make sure the connected capacity is within the range of 50% to 100% of the outdoor
unit capacity. In addition, if there are mixed connections with indoor units, make the
55kg 425 mm
Outdoor Air Unit connection capacity 30% or less of the outdoor unit capacity. (072 type)
572 mm
(ARXH072 type)
Specifications
Dimensions (Unit : mm)
Static Pressure Standard (range) Pa 185 (50-185) 200 (50-200) 200 (50-240)
Sound Pressure Level Side view (R)
dB (A) 42 44 47
Dimensions (H x W x D) mm 425×1,367×572 425×1,367×572 450×1,583×700 Side view (L) Top view
Weight kg 48 55 71
Connection Pipe Diameter (Small / Large) mm Ø9.52/ Ø19.05 Ø12.70/ Ø22.22 Ø12.70/ Ø22.22 (Drain hose)
Cooling 5 to 43 5 to 43 5 to 43
Operation Range ºCDB Front view
Heating -7 to 21 -7 to 21 -7 to 21
Refrigerant R410A R410A R410A
ARXH072GTAH ARXH096GTAH
Note : Specif ications are based on the followin g conditions .
Main drain port
Main
Cooling : Outdoor temperatur e of 33°CDB / 28°CWB. drain port
Safety
drain port
136 137
Ventilation
EEV unit
UTP-VX30A Control unit
UTY-VDGX
UTP-VX60A
Installation Limitation
UTP-VX90A
Multiple temperature sensors optimally control 50% –100% of outdoor unit capacity Within 30% of total capacity
the air handling unit and fan coil unit. [For 2EEV units connection (option)]
Arrangement as part of a VRF system • Separation Tube : UTP-LX180A 50%– 100% of outdoor unit capacity
AHU Thermistor
Transmission line
When connecting to an air handling unit, Indoor
Piping and wiring length
unit
the supply air temperature is controlled
DX-Kit by the discharge sensor. Air Handling Unit
EEV unit
VRF system
Max. piping length 5 m Control unit
Max. wiring length 10 m
Air Handling
FCU Unit
When connecting to a fan coil unit, the Control unit Max. wiring length 10 m
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor
Specifications
EEV unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A×2
Supports a wide range of capacity classes A variety of controls to match the application Power source V/Ø/Hz 230/1/50
Connectable capacity class kW 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0
• 2 EEV units can be connected in parallel and up to 20 HP (50 kW) • Central control using our VRF controllers or central management 5.6 6.3 8 10 12.5 14 22.4 25 40 50.4
Cooling
large capacity units. (Separation Tube of UTP-LX180A is required.) controllers (5.1-5.9) (6.0-7.1) (7.2-9.0) (9.1-11.1) (11.2-13.2) (13.3-18.0) (18.1-23.7) (23.8-28.0) (28.1-44.7) (44.8-50.4)
Capacity kW
• Connectable capacity range: 5 kW to 50 kW Heating
6.3 7.1 9 11.2 14 16 25 28 45 56.5
(5.7-6.7) (6.8-8.0) (8.1-10.0) (10.1-12.4) (12.5-15.0) (15.1-20.0) (20.1-26.5) (26.6-31.5) (31.6-49.9) (50.0-56.5)
EEV unit Transmission line Airflow Rate(Reference value) m3/h 1,060 1,200 1,520 1,600 2,000 2,240 3,560 4,000 6,400 8,000
External I/O
Dimensions (H × W × D) mm 160 × 220 × 90 (160 × 220 × 90)× 2
Interface Thermistor Weight kg 2 2×2
Piping (Option)
EEV unit DX-Kit Connection
AHU or FCU AHU or FCU Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 12.70 12.70 12.70 12.70
VRF Controller Modbus network
pipe diameter
(40 – 50 kW class)
(Future release)
138 139
Auto Louver Grille Kit (Option)
Models
UTD-GXTA-W
UTD-GXTB-W
UTD-GXTC-W
Feature
AIRSTAGE
TM
• Operation with indoor unit W2
Fitting Flame
Auto Louver can be operated by synchronizing remote controller of
indoor unit. Grille
OPTION
• Auto airflow direction and auto swing
• 4 steps selectable H1 H2
• Auto-closing louver
W1 D1 D2
When operation of indoor unit is stopped, the louver will
automatically close.
Unit: mm
Specifications
Model name UTD-GXTA-W UTD-GXTB-W UTD-GXTC-W
ARXD04/07/09/12/14GALH ARXD18GALH ARXD24GALH
Applicable Indoor Unit
ARXK04/07/09/12/14GCLH ARXK18GCLH ARXK24GCLH
Power source Connecting with Control box of indoor unit
Fixing of Auto Louver Grille Screw fixing to Flange or Square Duct
Extension Square Duct Limit 1.0m (Max. duct length between indoor unit and Grille)
Dimensions (H × W × D) mm 180 × 683 × (84+9) 180 × 883 × (84+9) 180 × 1083 × (84+9)
Net 2.0 2.5 3.0
Weight kg
Gross 3.0 3.5 4.0
Color White
Louver Motor Stepping Motor
Accessories Fitting Flame, etc.
°C 18 to 32
Operation Cooling
% RH 80% or less
Range
Heating °C 16 to 30
*: The Auto Louver Grille Kit can also be installed to ARXD07/09/12/14/18/24LATH revision code B models. Please refer to the Design & Technical manual for ”revision code “ details.
140 141
AIRSTAGE Option TM
Others
IR Receiver
UTY-RNRGZ2 Unit UTY-LRHGB1 UTY-LBHXD UTB-YWC
Wired
Remote
Controller
Human
UTY-RLRG Sensor Kit UTY-SHZXC
Simple Remote
Remote Sensor
UTY-RSRG, UTY-RHRG, UTY-RSKG, UTY-RHKG New amenity space can be UTY-XSZX
Controller 2-wire type 3-wire type Unit offered by installing the
Remote sensor.
Wireless UTG-UKGC-W
Remote
Controller UTY-LNHG
UTG-UKGA-B
Cassette
Grille UTG- UTG-UKGC-W
UTG-UFGD-W UTG-UGGA-W
UFGD-W UTG-UKGA-B
Group
Remote
Controller UTY-CGGG + UTY-VGGXZ1 UTG-UGGA-W
Central Auto
Remote Louver UTD-GXTA-W
Controller UTY-DCGG Grille Kit UTD-GXTB-W(18)
UTD-GXTC-W(24)
Touch
Long Life
Panel UTD- UTD-
UTY-DTGGZ1 Filter
Controller LF25NA LF60KA
System
Controller,
UTD-
System Flange SF045T UTD-
UTY-APGXZ1, UTY-ALGXZ1
Controller UTD- RF204
Lite RF204
Interface
Drain
UTY- Pump UTZ- UTR-
UTY-TFSXZ1 UTY-TFSXZ1 UTY-TFSXZ1 Unit
TFSXZ1 PX1NBA DPB24T
Wireless
LAN
Interface Indoor unit 950
600
Panel
Wide 600
Panel UTG-AKXA-W
FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1 UTG-AKXA-W
UTG-AGYA-W
(mm)
(mm)
Insulation
MODBUS
for High UTZ- UTZ- UTZ-
Interface FJ-RC-MBS-1 FJ-RC-MBS-1 FJ-RC-MBS-1 FJ-RC-MBS-1 UTZ-KXRA
Humidity For Compact Cassette type / KXGC KXRA KXRA
Cassette type
External Half
Switch Concealed This kit is used to half
Controller UTY-TERX Kit UTR-STA
conceal floor type indoor
unit into the wall.
142 143
AIRSTAGE Option TM
OPTIONAL PARTS
WHITE-USB-KEY
(Software Protection Key)
MODBUS® Interface KNX® Convertor for VRF KNX® Convertor for Indoor Unit KNX® Interface
FJ-RC-MBS-1 UTY-VKGX UTY-VKSX FJ-RC-KNX-1i
Simple Remote Controller Wireless Remote Controller IR Receiver Unit
UTY-RHRG UTY-LNHG UTB-YWC
Without operation mode For All Duct types except Large Airflow Duct
UTY-PTGXA
Panels
System Controller Lite System Controller
UTY-ALGXZ1 UTY-APGXZ1
For Cassette type
Cassette Grille Cassette Grille Cassette Grille Cassette Grille
UTG-UFGC-W UTG-UGGA-W UTG-UKGC-W UTG-UKGA-B
UTY-PLGXR2 UTY-PEGXZ1 For Compact For Cassette type For Circular Flow For Circular Flow
Cassette type Cassette type Cassette type
UTY-PLGXA2
UTY-PLGXE2
UTY-PLGXX2
144 145
AIRSTAGE Option TM
OPTIONAL PARTS
Others
UTY-XWZXZC UTY-XWZXZF
For RB unit For Central Remote Controller For Touch Panel Controller
Long-Life Filter Auto Louver Grille Kit Drain Pump Unit
UTY-XWZXZ6 UTY-XWZXZ7 UTY-XWZXZA
UTD-LF25NA UTD-LF60KA UTD-GXTA-W (for ARXD04/07/09/12/14, ARXK04/07/09/12/14) UTZ-PX1BBA
For Medium Static For High Static UTD-GXTB-W (for ARXD18, ARXK18) For Low Static Pressure Duct type
Pressure Duct type Pressure Duct type UTD-GXTC-W (for ARXD24, ARXK24) UTY-XWZXZB UTY-XWZXZ8
For Slim Duct type / Mini Duct type UTZ-PX1NBA
For Medium Static Pressure Duct
UTY-XWZXZA
Function
Input
UTY-XWZXZD
Operation / Stop
UTY-XWZXZB
For Compact Cassette type
UTY-XWZXZ7 *2
All On / All Off
50 UTY-XWZXZ8 *2
UTY-XWZXZD
Fresh Air Intake Kit Air Outlet Shutter Plate Air Outlet Shutter Plate Forced Stop
UTY-XWZXZB
Cooling/ UTY-XWZXZ6
UTY-XWZXZ6 UTY-XWZXZ6
Heating Priority UTY-XWZXZB
* Not applicable for VRF V-II tropical and V-III tropical series
Outdoor Unit
Operation Peak UTY-XWZXZ6
Control
Power Usage
*2
Information from UTY-XWZXZF
*2
Electricity Meter
For Ceiling type For Floor type
Output
*2: Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary : Dry Contact : Apply Voltage
because Touch Panel Controller has an external input terminal block.
146 147
AIRSTAGE Option TM
OPTIONAL PARTS
Total cooling capacity of indoor unit kW 28.0 or less 28.1 to 56.0 56.1 or more
Header
3-6 Branches UTR-H0906L UTR-H1806L
UTP-BX090A UTP-BX180A UTP-BX567A UTP-LX180A for DX-Kit Model name
3-8 Branches UTR-H0908L UTR-H1808L
Suction Suction Suction
Gas Pipe Gas Pipe Gas Pipe Total cooling capacity of indoor unit kW 28.0 or less 28.1 to 56.0
Discharge Discharge
Gas Pipe Gas Pipe
EV Kit
Liquid Pipe Liquid Pipe
Liquid Pipe Liquid Pipe Model name UTR-EV09XB UTR-EV14XB
ASHE004GTAH AGHE004GCAH
ASHE012GCAH AGHE012GCAH
Application Model ASHE007GTAH AGHE007GCAH
ASHE014GCAH AGHE014GCAH
ASHE009GTAH AGHE009GCAH
148 149