You are on page 1of 75

VRF

Variable Refrigerant Flow System

CATALOGUE
HEAT PUMP & HEAT RECOVERY

ISO 9001 ISO 14001 ISO 9001 ISO 14001 ISO 9001 ISO 14001
Certified number: 01 100 89394 Certified number: 01 104 9245/01 Certified number: 01 100 79269 Certified number: CNBJ311153-UK Certified number: 15914Q10065R4M Certified number: 15912E10022R3M
Fujitsu General (Thailand) Co., Ltd. Fujitsu General (Shanghai) Co., Ltd. Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.

FUJITSU GENERAL (Euro) GmbH participates in the ECP


programme for VARIABLE REFRIGERANT FLOW SYSTEMS
Check ongoing validity of certificate:
www.eurovent-certification.com

“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas.
• Specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorised dealer.
• iPhone and iPad are trademarks of Apple Inc., registered in the U.S. and other countries.
• Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.

• Actual products’ colors may be different from the colors shown in this printed material.
Distributed by :

15/F, Dominion Centre,


43-59 Queen's Road East,Hong Kong

Hotline : 2529 7555


Email : pic@alpha-genral.com

Website : http://www.general-aircon.com http://www.fujitsu-general.com/


Copyright© 2013-2017 Fujitsu General Limited. All rights reserved.
6EG009-1709E
CREATION
OF COMFORT
OUR SOLUTION FOR ALL PROPERTIES .............................. 4
NEW PRODUCTS ............................................................. 6
Light Commercial Solutions ........................................... 8
Commercial Solutions .................................................. 14

AIRSTAGETM CORE TECHNOLOGY


HIGH ENERGY EFFICIENCY ............................................ 18
MORE COMFORT ........................................................... 20
HIGH RELIABILITY ........................................................ 22
DESIGN FLEXIBILITY ..................................................... 24
EASY INSTALLATION ..................................................... 26
The AIRSTAGETM series provides high energy savings, comfort, and reliability to the end user. The design, installation, EASY SERVICE & MAINTENANCE .................................... 28
and servicing were developed based on the concepts of high flexibility and simplicity. We offer an abundant VRF
system lineup to match regional and customer needs by providing the best combination from low to high capacities AIRSTAGETM SERIES
and from giving priority to conserving installation space to giving priority to high efficiency. AIRSTAGETM LINE-UP ..................................................... 32
HEAT RICOVERY TYPE AIRSTAGETM VR-II ......................... 34
HEAT PUMP TYPE AIRSTAGETM V-III ............................... 42
HEAT PUMP TYPE AIRSTGAETM J-IIIL ............................... 48
HEAT PUMP TYPE AIRSTGAETM J-III ................................ 52
HEAT PUMP TYPE AIRSTGAETM J-IIS ............................... 56

AIRSTAGETM INDOOR UNITS


INDOOR UNITS LINE-UP ............................................... 62
4-way Flow Compact Cassette ...................................... 64
4-way Flow Cassette .................................................... 66
Circular Flow Cassette .................................................. 68

For LARGE BUILDING For SMALL BUILDING


Mini Duct ..................................................................... 70
Slim Duct / Slim Concealed Floor ................................. 72
Low Static Pressure Duct / Concealed Floor ................... 74
Medium Static Pressure Duct ....................................... 76
High Static Pressure Duct ............................................ 78
Large Airflow Duct ....................................................... 80
Compact Floor ............................................................. 84
Floor / Ceiling .............................................................. 86
Ceiling ......................................................................... 88
Compact Wall Mounted (EEV Internal) ........................ 90
Wall Mounted .............................................................. 92

AIRSTAGETM CONTROL SYSTEMS


BEST CONTROL SOLUTION FOR EACH PROPERTY.............. 98
CONTROL SYSTEM OVERVIEW ...................................... 100
COMPARISON TABLE OF CONTROLLERS ....................... 102
• Individual Controller ............................................. 104
• Centralized Controller ........................................... 110
• Convertor / Adaptor ............................................... 120

Heat Recovery Modular type Heat Pump Modular type Heat Pump type Heat Pump type Heat Pump type
for simultaneous heating and cooling operation for heating or cooling operation for heating or cooling operation for heating or cooling operation for heating or cooling operation VENTILATION
DX-Kit for air handling applications ............................ 132
AIRSTAGETM OPTION
Auto Louver Grille Kit .................................................. 135
8 HP - 48 HP 34 Models 8 HP - 54 HP 39 Models 8 HP - 12 HP 3 Models 4 HP - 6 HP 6 Models 4 HP - 6 HP 3 Models
• Space saving combination: 8 HP to 48 HP/21 models • Space saving combination: 8 HP to 54 HP/24 models • 3 phase • Single phase, 3 phase • Single phase OPTIONAL PARTS LIST ................................................. 136
• Energy efficiency combination: 16 HP to 44 HP/13 models • Energy efficiency combination: 16 HP to 46 HP/15 models OPTIONAL PARTS ....................................................... 138

P34~ P42~ P48~ P52~ P56~

2 3
OUR SOLUTION FOR ALL PROPERTIES
Fujitsu General provides the best solutions suitable for properties.

Solution Point Target Property

We provide Fujitsu General LIGHT COMMERCIAL


total solutions For Small offices,
for the property unique needs. Excellent Hotels, Shops
Energy Saving
and Restaurant etc.

We offer comfortable and economical air


conditioning systems focused on small to
Pleasant Easy medium-sized buildings.
Comfort Installation
THE
TOTAL SOLUTION
COMMERCIAL
For Large Building

High Enhanced We provide single and modular type VRF


Durability Safety systems designed for high efficiency,
comfort, freedom of design, easy installation
and high reliability.

4 5
NEW PRODUCTS

Small VRF AIRSTAGE™ J-IIIL Individual Control


Wired Remote Controller (Touch Panel) Simple Remote Controller
• Easy-to-use and highly-functional controllers • Up to 16 indoor units can be controlled
• Maintains 2 separate set points for heating and cooling. • Simple design to match the stylish interior.
• Automatically changes mode between heating and cooling. • Large LCD screen & simple operation buttons

Centralized Control
Touch Panel Controller System Controller
• Up to 400 indoor units can be controlled System Controller Lite
• Control and monitor Fujitsu’s air conditioner via LAN or Internet. • Up to a maximum of 4 VRF network systems, 1600 indoor units, and
• Easy maintenance & installation 400 outdoor units can be controlled.*
• Simple BMS, 3rd party supported by Modbus communication can be
controlled.

• 8 to 12 HP class 3 phase 3 models *: System controller lite = Up to a


• Compact Design maximum of 1 VRF network system, 400
indoor units, and 100 outdoor units can
• Small Room Application be controlled.
• Top Class Low Operating Sound
• Up to 30 units can be connected

Indoor Units For Light Commercial Convertor / Adaptor Service & Maintenance Tool
Various indoor units Various Convertors Service Tool & Web Monitoring Tool
• 4 types 35 models • 4 models of hardware and software are put on the market all together. • Extensive monitoring and analysis functions for installation and
• The substantial capacity range and maintenance
BACnet®Gateway KNX® Convertor External Switch
indoor unit type suit to various room • Troubleshooting is performed by
Controller
size and layout monitoring each air conditioning
• 4 types 1.1 kW indoor units unit remotely during periodical
Circular Flow Cassette Mini Duct Compact Floor system checks.
Software For VRF
• Automatic operation check for
refrigeration cycle.

Hardware For indoor unit


Wall Mounted

6 7
Light Commercial Solutions

SMALL OFFICES
Comfortable office air
conditioning without airflow
feeling

Fujitsu General provides perfect total air conditioning systems that take into
account energy saving, low noise, comfortable airflow, small room application
and Centralized control for small-sized office buildings with many small rooms.

Circular Airflow Cassette blows out in all directions without


temperature unevenness

Energy saving solution suitable for


meeting rooms and business Individual airflow direction control to prevent people from
being exposed to airflow
discussion rooms
When there are no people in the room, save operation
starts automatically to prevent unnecessary power
consumption by linking up with a human sensor and
external input/output kit.

Energy saving operation when


there are no people by linking
up with human sensor

3.2 m
8.8 m
Human sensor
(option)

1.1 kW personal air conditioning

Compact and low noise design


outdoor unit Centralized control of both air
This compact outdoor unit doesn’t take up much space conditioning and lighting Various range of low capacity
even if installed in a machine room or on the rooftop.
This unit secures enough static pressure even if there are It is possible to perform centralized control to stop the 1.1 kW indoor units to suit small
louvers. Low noise operation is possible at nighttime by operation of lighting and ventilation equipment in rooms or spaces.
a low noise mode. addition to air conditioners. This is useful in energy
saving management over the whole building.

System Controller Lite


VRF
Small VRF System
indoor units

Up to 12 HP by compact
outdoor unit
Facilities
Small VRF system is suitable for the buildings with many
Lightning Ventilation Energy Recovery Ventilator
small rooms. Max. 30 indoor units can be connected.

8 9
Light Commercial Solutions

HOTELS
Guest room air conditioning
with excellent comfort, energy saving
and easy installation
Space saving
Fujitsu General provides perfect total air conditioning systems that take Mini duct type with 198 mm
into account comfort, energy saving, external appearance, safety and height and 450mm depth.
This can be installed in 
easy installation for small low-rise hotels. narrow ceiling space easily.

Mini Duct

Appearance-oriented compact
outdoor unit
Due to the lowest and most compact design in the
industry, the appearance of hotel is not damaged even
when installed on the building.

Card key switch available Comfortable airflow that


Using the card key prevents you switches up and down air
from forgetting to switch off the directions
air conditioner. The Auto Louver Grille Kit
achieves comfortable airflow by
adjusting the air direction.

Small VRF System Use of an external Simple Remote Controller with


connect switch sophisticated design

Large space air conditioning in Ventilation of the whole Centralized control of air Safety measures
the reception and lobby hotel supported conditioning in shared spaces
Ultra-large duct type single split system suitable for Outdoor air processing is essential in hotel spaces Air conditioning in shared spaces such as lobbies Refrigerant leak detection system is provided. This system
large spaces with high ceilings with a high degree of airtightness. The DX-Kit can and hallways is controlled centrally. Temperature detects a refrigerant leak and then sounds an alarm to shut
link up with air conditioners to ensure sufficient and operating conditions can be managed off the leakage.
ventilation. This system can be expanded. without the adjustment by guests.

Refrigerant
leak detector

Large Duct
• Emergency stop in the event of an emergency
• Emergency stop function for each refrigerant system
System Controller (VRF system)

10 11
Light Commercial Solutions

SHOPS, RESTAURANT COMPLEX


& COMPLEX BUILDING Small VRF system BUILDING
LAN
or Wireless
Fujitsu General provides perfect total air conditioning LAN
systems that offer smooth support by tenant, by purpose Tablet PC
and by customer visit frequency in shops and restaurants
with multiple lighting and a high density of customers.
Centralized control of Remote
air conditioning for monitoring
all tenants of air
Centralized control with simple touch conditioning
panel operation of scheduled operation by
tenant, centralized control and electricity
charge apportionment

High Static Pressure Duct

Appropriate air conditioning


in the atrium space
SHOPS
Appropriate air conditioning of the high ceiling and
glass-sided atrium space with a large duct system

Low outside air


temperature cooling air
conditioning support
Low outside air temperature cooling
operation is necessary in winter in stores
with a lot of heat inside. Air conditioning
For offices etc. For restaurant etc. system can be supported flexibility to allow
cooling operation at -15°C

Color variations by two panels


RESTAURANT Both black and white panels are available for Cassette
type. Black panel is suitable for the dark place such as a
30-150 Pa
restaurant with atmosphere. White panel is usually used
at bright areas such as offices. Medium Static Pressure Duct

12 13
Commercial Solutions

LARGE BUILDING Ventilation(AHU) linked with


VRF system
Fujitsu General’s DX-Kit enable other manufacture’s air handling
Fujitsu General provides modular type VRF systems that units(AHU) to be incorporated into a Fujitsu VRF system.
seek high efficiency, comfort, design freedom, easy Possible to control comfortable air conditioning and ventilation.
installation and reliability for skyscraper buildings. Indoor unit
Transmission line

VRF system

Individual air conditioning


system for large buildings
Capacities can be expanded up to simultaneous cooling
and heating with maximum 48HP. Large individual air
conditioning is supported. Air Handling
Unit

Control unit

EEV unit
DX-Kit
Wired R.C.
Thermistor

Smart and cutting edge design. Extensive lineup from 8 HP


to 48 HP in 2 HP increment. Connectable indoor unit capacity
ratio up to 150%

8 HP - 48 HP 34 Models
• Space saving combination: 8 HP to 48 HP/21 models
System Controller
• Energy efficiency combination: 16 HP to 44 HP/13 models
(UTY-APGXZ1)
System Controller Lite
(UTY-ALGXZ1 & UTY-PLGXX2)

Link up with a variety of BMS


Centralized control including facilities and equipment in addition to air
Abundant lineup suitable to match the operating environment conditioning is possible by linking up with MODBUS, BACnet, KNX and
other various interfaces.
VRF series lineup to meet various needs such as energy
saving-orientated models and models compatible with a high
outdoor air temperature of 52°C

Heat Pump Modular type for heating or cooling operation

8 HP - 54 HP 39 Models
• Space saving combination: 8 HP to 54 HP/24 models
• Energy efficiency combination: 16 HP to 46 HP/15 models

14 15
AIRSTAGETM VRF SYSTEMS CAN BE DESIGNED TO
CREATE AN AIR CONDITIONING SOLUTION TO
SUIT MOST BUILDINGS REQUIREMENTS.

Airstage VRF Systems can be designed to effectively provide an air

conditioning solution from a large domestic residence through to a

large scale commercial building.

AIRSTAGE
TM
HIGH ENERGY EFFICIENCY

CORE TECHNOLOGY
MORE COMFORT
HIGH RELIABILITY
DESIGN FLEXIBILITY
EASY INSTALLATION
EASY SERVICE & MAINTENANCE

16 17
AIRSTAGE CORE TECHNOLOGY
TM

HIGH ENERGY EFFICIENCY Operation Performance is Efficiently Controlled.

Room temperature set point (°C)


30
Heating Cooling

limitation 28
26
The minimum and maximum temperature ranges can
be limited, which provide further energy saving while 24

maintaining the comfort of the occupants. 22


20
18
16
14
12
10
Original Set Temp Set point limitation setting

Auto-off timer
New wired remote controller is equipped with an OFF timer
function that automatically stops operation when a fixed time
has elapsed from the start of operation. This prevents waste of
energy.
Furthermore a new wired remote controller can set up the
interval of time in case operation stops. Set interval time hour (17:00 to 24:00)
ON Auto OFF

Set off time


(30 to 240 minutes)
OFF
17:00 24:00

Energy saving management


A variety energy saving operations can be
set and managed depending on the season,
weather, and time period.
Highly Energy Efficiency New model
Excellent energy saving operation is
Significantly efficiency is improved by Previous model performed by using System Controller.
EER COP
using DC twin rotary compressor, inverter technology,
and large heat exchanger.

16%UP! 31%UP! 7%UP! (Screen image is Energy manager software(Option))


5
27%UP! 35%UP! System Controller

4.3 4.84 8%UP! 4.23


3.94 4.31 3.95
4
3.71 3.7 3.71
3.45
3.2
3
3.1 Capacity save operation Setting
Capacity
Capacity save
range
Operation capacity can be set in 5 steps for rated capability.
The power consumption at peak is cut down and the maximum
100% Setting
2 load is suppressed. level
80%

60%
1
40%

0 0%

Heat Recovery (10HP) Heat Pump (8HP) Heat Pump (6HP) Time

18 19
AIRSTAGE CORE TECHNOLOGY
TM

MORE COMFORT
Precision refrigerant flow control High

Hot
Hot ± 0.5°C
Precise and smooth refrigerant flow control is achieved by using Set temp.
a DC Inverter control in conjunction with individual indoor unit
electronic expansion valve control. This allows high precision Cold
comfortable temperature control of ±0.5°C.

Low
Thermal change of the room
*Simulation in heating operation.
Comfortable operation is
Reach the set achieved due to a small variation of
temperature quickly room temperature

Low sound level design 19 dB(A)


Small capacity indoor units respond for the demands of several At low mode
heating operation
applications.
These models will be able to offer greater audibility comfort by
operating at super low sound levels.
Especially, Wall mounted (EEV external) type is 19dB(A) when
low mode heating operation.

Small capacity indoor unit

Quiet operation
Low noise mode
Two low noise modes can be selected automatically by quiet priority setting and capacity priority
setting depending on the indoor environment and outside temperature load. This feature can be
controlled via outdoor unit external input and/or system controller.
Quiet priority setting Capacity priority setting

Air Air
conditioning conditioning
load factor Heat load load factor Heat load

Auto changeover function


100% down 100%
Capacity Capacity Alternated
At Auto setting, the cooling/heating mode is automatically switched Automatic cooling / heating operation for each room is possible automatically
according to the set temperature and room temperature. 0 0

2°C Operating 58dB Operating 58dB


sound sound
Heating Cooling 0
0.5°C Room A Room B 0
Set Temp. 24°C 18°C time Reset automatically time
- 0.5°C Quiet priority low noise mode
Capacity priority low noise mode

- 2°C time Dry Room C Room D Room E Fan


27°C OFF 23°C
Cooling operation Cooling fan operation
Heating operation Heating fan operation Previous model V-III series (Heating operation)
Non-stop oil recovery operation
A comfortable room condition is maintained during oil recovery
Auto changeover setting allows for the product to easily switch between mode because the product continues to operate without stopping
cooling and heating modes regardless of the operation mode of other the cooling or heating operation.
indoor units. This can be done via specific indoor unit with wired remote
*: AIRSTAGE VR-II series is not available. Operation stopped Non-stop oil
controller. This ensures comfortable operation all year round. at oil recovery recovery operation

Switching to cooling and ON ON


heating mode by specific
remote controller in the OFF
main room, etc. Time Time

20 21
AIRSTAGE CORE TECHNOLOGY
TM

HIGH RELIABILITY
Backup operation
If one compressor fails, backup operation will be performed by
the remaining compressors*.

*: Note: Backup operation may not be possible depending on the trouble state.

Advanced refrigerant control


Innovative compressor control logic has been introduced in
order to balance the refrigerant mass flow rate of each outdoor ON ON ON ON ON OFF
unit by controlling the inverter speed.
DC DC DC DC DC DC
1 2 3 1 2 3

Master Slave 1 Slave 2 Load level Master Slave 1 Slave 2

Balance operation Unbalance operation


condition condition

Liquid flow back protection Completely


from
Evapolator
vapourised refrigerant
By adopting a large sized accumulator, the not completely
vapourised refrigerant stays inside of the accumulator to Compressor

Outdoor unit rotational operation ensure no liquid refrigerant is being fed into the compressor.
Large sized
Accumulator
The compressor starting order is rotated so that the running time is shared.
Rotation

Liquid refrigerant
(stays inside of
accumulator)

DC DC DC DC DC DC
1 2 3 1 2 3

Adoption of blue fin heat exchanger Blue fin heat exchanger

Corrosion resistant of the heat exchanger has been improved Cobalt Blue protection

by the introduction of blue fin treatment to the outdoor unit’s Standard chromate protection
heat exchanger.
Aluminium base material
Rotation Rotation
DC DC DC Hydrophilic coating
1 2 3

Note: Rotational operation is alternated by the start / stop timing of the compressor.

22 23
AIRSTAGE CORE TECHNOLOGY TM

DESIGN FLEXIBILITY
Overall piping length 1,000m Total pipe length
High capacity connection
1,000m max. AIRSTAGETM VR-II series AIRSTAGETM V-III series
Heat Recovery type Heat Pump type
8HP-48HP 8HP-54HP
Connectable indoor unit Connectable indoor unit
capacity range capacity range
Actual pipe length
50% to 150%*1 50% to 150%*3
165m Height difference
(VR-II, V-III) between outdoor and Connectable indoor Connectable indoor
indoor units unit number unit number

50m max. up to 64 up to 64
For the outdoor unit installed below
the indoor units: 40m max.
AIRSTAGETM J-IIIL series AIRSTAGETM J-III series
Heat Pump type Heat Pump type
8HP-12HP 4HP-6HP
Connectable indoor unit Connectable indoor unit
capacity range capacity range
Pipe length from first
separation tube to the Height difference
between indoor and
50% to 150% 50% to 150%*1 *1. Conditions of maximum connectable indoor unit
capacity ratio is as the chart below.
farthest indoor unit
indoor units *2. Only 4HP is 46%
60m max. 15m max.
Connectable indoor
unit number
Connectable indoor
unit number
*3. Max. capacities in the combinations including the
(VR-II) 18HP outdoor unit fall below 150%.
up to 30 up to 13 Maximum connectable
90m* max. Series
indoor unit capacity ratio
(V-III) Without 1.1kW With 1.1kW
models models*4
AIRSTAGETM J-IIS series
Heat Pump type VR-II 150% 130%
*: The limitation on the pipe J-IIIL 150% 150%
length between the farthest Connectable indoor unit
capacity range J-III 150% 150%
IU and the nearest IU
4HP-6HP
originated from the first
separation tube must be
50 %*
2
to 130 %*
1 J-IIS 130% 117%

*4. In the case of connectable indoor units, 1.1 kW models


60m or less.
and Cassette and / or Duct type of 9.0 kW class or
Connectable indoor
more, maximum connectable indoor unit capacity
unit number
ratio is 110%.
up to 8

High static pressure Wide operating range


Installation in extreme temperature conditions is possible due to an increase in operational range.
The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa to 82Pa.
This allows outdoor units to be installed within plant rooms in high rise buildings. AIRSTAGETM VR-II series AIRSTAGETM V-III series
Heat Recovery type Heat Pump type
Powerful discharge (°C) (°C)

air prevents a short-circuit. 80 Pa (VR-II) 60


50
Cooling
46°C
60
50
Cooling
46°C
Cooling &
82 Pa (V-III) 40
30
Heating Heating
40
30
Heating
21°C 21°C 21°C
20 20
10 10
Previous model VR-II, V-III 0 0
-10 -10
-20 -10°C -10°C -20 -15°C* 5
-20°C -20°C

AIRSTAGETM J-IIIL series AIRSTAGETM J-III series AIRSTAGETM J-IIS series


Heat Pump type Heat Pump type Heat Pump type
(°C) (°C) (°C)
60 Cooling 60 Cooling 60 Cooling
50 46°C 50 46°C 50 46°C
40 40 40
Heating Heating Heating
30 30 30
21°C 21°C 21°C
20 20 20 *5. Note : When a multiple outdoor unit
10 10 10 connection is used, operating range is
0 0 0 from -5°C to 46°C in cooling.
-10 -10 -5°C -10 -5°C *6. Note : When a multiple outdoor unit
Large diameter fan and DC motor has been utilized allowing an external static -20 -15°C -20 -20
connection is used, operating range is
-20°C -20°C -20°C
pressure of 80Pa to 82Pa. This is approximately 2.6 times greater than the previous model. from -5°C to 52°C in cooling.

24 25
AIRSTAGE CORE TECHNOLOGY
TM

EASY INSTALLATION
Easily transported Simple wiring work
Easily craned using lifting belt hooks Installation of the wiring systems is made easier as the
communication wiring can be installed continuously between
Design of outdoor unit allows for lifting
the indoor, outdoor and RB units.
straps to be used
or

Parallel connection Serial connection

Transporting by forklift
Transport with forklift is possible.
Easy evacuation - using vacuum Air Air

mode function
The vacuum mode function enables all expansion valves of
indoor units to be fully opened, making it easy to evacuate all
the air inside pipe lines and indoor units.

Air
Outdoor unit Vacuum pump

Can be transported in
a small elevator Automatic address setting
The address of the indoor unit, RB unit and signal amplifier can be set through the automatic function setting on the outdoor unit PCB.

Automatic address setting is Addresses are automatically


performed at outdoor unit distributed from outdoor unit.

1 Signal Amplifier

RB unit 3 7 1 0

Easy access Expansion of work space

By adopting a L-Shape front panel that can be removed, the work 3 7 1 0


space for installation and service has been significantly expanded by
this new design. For multiple installations, work is performed easily 2 4 5 6
and efficiently even in a narrow space.
Press the push button
switch of outdoor unit. 2 4 5 6
Reduced installation Manual address setting from indoor unit and remote controller is also possible.
intervals by front access

Easy commissioning by Service Tool


Flexible piping connection
Service tools can be used to check the refrigerant temperature,
Piping and wiring are available to the front, left and right, and pressure, and the operating status of the electronic expansion
bottom. valve, making it easy to determine whether the units are
connected properly.

Flexible installation by
4 way pipe direction
(J-IIIL is 3 way pipe direction.)

26 27
AIRSTAGE CORE TECHNOLOGY
TM

EASY SERVICE & MAINTENANCE


Design for Easy Maintenance Error diagnosis by Service Tool
7 segment LED is used to make it easy to check the details about the Connection to Service Tool
function setting status, refrigerant temperature, pressure, compressor
• Detail operation status and recent error history can be checked and analyzed by using the Service Tool.
operation time, and other factors for each model to make it easy to
• Last 5 min. operation memory can be also be recorded.
perform self-diagnostics.

Service Tool
UTY-ASGXZ1
Outdoor unit Software

Transmission line

USB adaptor
(Locally purchased)

Easy to read 7-segment LED : Confirm Movable PCB panel


Indoor unit
detailed operational and error status Easier for maintenance
without using any specific equipment. work behind the PCB

7-segment LED

• Operation mode status Remote monitoring


• Discharge temperature/Pressure status
• Compressor operation indication The Web Monitoring system allows you to Monitoring Side
• Address/type/number of outdoor unit view system operation anytime over the
internet, ensuring issue free operation.
The operating VRF network system in the
VRF Network System Side
building can be monitored real time over
the Internet.
Error status can be checked easily via the indoor unit wired controller Error status can be cheked easily by outdoor unit display Outdoor unit

An error code is displayed on a liquid crystal screen. Transmission line

Wired Remote Controller Simple Remote Controller Internet


or
System number Remote Public Telephone
001: Controller controller address USB adaptor
002: Indoor unit Error code Line
Error code (Locally purchased)

Web
Monitoring Tool
Unit number

Error and
quantity Indoor unit
Wired Remote Controller annunciation
(Touch panel)
Error status / Error history

Error code

Abnormal indoor
unit address

28 29
The AIRSTAGE 5 Series has a total of 85 models
to meet the environmental and
building size requirements.

The AIRSTAGE series outdoor units were developed with structural designs and

advanced inverter technology to

provide higher efficiency.

High durability technology has also been incorporated to

ensure long-term use.

AIRSTAGE
TM
AIRSTAGE™ LINE-UP

SERIES
HEAT RECOVERY TYPE AIRSTAGE VR-II
HEAT PUMP TYPE AIRSTAGE V-III
HEAT PUMP TYPE AIRSTAGE J-IIIL
HEAT PUMP TYPE AIRSTAGE J-III
HEAT PUMP TYPE AIRSTAGE J-IIS

30 31
AIRSTAGE Series TM

AIRSTAGE™ LINE-UP
Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series
matched to the size and application of the property.

Outdoor units range


HP 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

kW class 12.1 14.0 15.5 22.4 28.0 33.5 40.0 45.0 50.4 55.9 61.5 67.0 73.5 78.5 85.0 90.0 95.0 100.5 107.0 112.0 118.5 123.5 130.0 135.0 139.0 143.0 147.0

Space
saving
AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH AJH432GALH

Heat Recovery

High
Efficiency
AJH144GALHH AJH198GALHH AJH216GALHH AJH234GALHH AJH252GALHH AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH342GALHH AJH360GALHH AJH378GALHH AJH396GALHH

Space
saving
AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH180LALBH AJH198LALBH AJH216LALBH AJH234LALBH AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH AJH342LALBH AJH360LALBH AJH378LALBH AJH396LALBH AJH414LALBH AJH432LALBH AJH450LALBH AJH468LALBH AJH486LALBH

Heat Pump

High
Efficiency
AJH144LALBHH AJH162LALBHH AJH180LALBHH AJH216LALBHH AJH234LALBHH AJH252LALBHH AJH270LALBHH AJH288LALBHH AJH306LALBHH AJH324LALBHH AJH342LALBHH AJH360LALBHH AJH378LALBHH AJH396LALBHH AJH414LALBHH

Space
saving
Heat Pump
AJH072LELAH AJH090LELAH AJH108LELAH

High
Efficiency
(Single phase)
AJH040LBLAH AJH045LBLAH AJH054LBLAH

Heat Pump
High
Efficiency
(3 phase)
AJH040LELAH AJH045LELAH AJH050LELAH

Space
Heat Pump saving
AJH040LCLAH AJH045LCLAH AJH054LCLAH

32 33
Features

HEAT RECOVERY TYPE Efficiency in actual operation


Top class high COP is achieved for all combinations by our unique heat exchanger structure,
high efficient DC twin compressor, and our own technologies.

(COP) 5
4.39 4.30 4.34 4.30
4.13 4.07 4.05 4.01 4.01 4.00 4.00
3.90 3.92 3.90 3.91 3.92 3.90 3.91 3.91 3.98 3.92
4
Space saving
Smart and cutting edge design
combination 3
Extensive lineup from 8HP to 48HP in 2HP increment
Connectable indoor unit capacity ratio up to 150%
2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 (HP)

(COP) 5 For 24 HP Combination

System Outline 4
4.39
4.22
4.39 4.35 4.32 4.30
4.24 4.23 4.18 4.17
4.08 4.13 4.05
Space saving Energy efficiency

Energy efficiency
Simultaneous cooling and heating operation combination 3
using 1 refrigerant system
Cooling and heating can be freely selected for each indoor COP 12.6% UP
2
unit to provide simultaneous cooling and heating in rooms 16 22 24* 26 28 30 32 34 36 38 40 42 44 (HP)
with large temperature differences.

Annual cooling operation


Use annual cooling operation for the rooms and other Energy saving technology that boosted operation efficiency
spaces that require constant temperature control
throughout the year.

Powerful large propeller fan


Handles changes in the temperature difference By using CFD*1 technology, a newly designed fan
The operation mode can be freely changed when there achieves high performance and low noise operation.
are large temperature differences during the day, such as *1. CFD = Computational Fluid Dynamics
between seasons.

3 phase DC fan motor


Efficiency is substantially improved by high efficient
motor with sophisticated driver control. In addition,
low noise is realized by DC fan motor.

Subcool heat exchanger


High Heat Exchange efficiency is achieved by using
Heat exchanger an internal projection shape double pipe
Large Building High pressure liquid
construction.
Low pressure gas
4 way valve
High pressure gas
Compressor
Outdoor unit
Sine-wave DC inverter control
High efficiency is realized by adoption of reduced
RB unit switching loss IPM.
Heat
exchanger
Indoor unit
EEV High efficient compressor
Cooling Heating Large capacity DC inverter
compressor
Our Heat recovery systems achieve high operating energy efficiency Large capacity high efficient DC twin rotary
by drawing heat from the room to be cooled and transferring it as compressor with excellent intermediate capability.
energy for rooms that are to be heated.

Our Heat recovery systems High


Heating & Cooling 4-face heat exchanger
achieve high operating energy Heat exchange efficiency is significantly improved by
efficiency by drawing heat Mainly Cooling Mainly Heating
the introduction of a new 4-face heat exchanger that
from the room to be cooled
increases effective surface area.
and transferring it as energy
COP

for rooms that are to be


No-Heat Recovery model
heated.

Front intake port


0 50 100 (%) (corner cut air inhaling structure)
Heating ratio
In multiple outdoor unit installations, the unique front intake
design improves airflow into the Heat Exchanger.

34 35
Features

All inverter compressor Flexible piping connection


Large capacity DC inverter A more flexible refrigerant piping work is possible by the use of various piping and RB Unit
compressor connections, for adjustments to the floor layout and building structure.

Large capacity high efficient


DC twin rotary compressor
with excellent intermediate
capability. Separation tube

RB Unit RB Unit
(Single type) (Multi type)

High efficient compressor

Capacity
speed control Max.3 or 8
Max. 8 indoor unit
indoor units
Comfortable space with 0.1Hz
small room temperature
changes and little energy Single Group Single
&
Group RB Unit less
loss is created by 0.1Hz connection connection connection connection connection*2

steps compressor speed


control. Individual Simultaneous Individual Simultaneous Cooling
Application cooling and cooling and heating cooling and heating cooling and heating only
heating

• The RB unit can be freely positioned between the first branch and the indoor unit.
• The maximum height difference between RB units is 15 m.
* 2. RB Unit is not necessary for cooling only use.
Inverter frequency

Flexible installation of RB unit


Multiple outdoor operation control
When multiple outdoor units are connected a sophisticated Height
operation is performed by each compressor. Rather than
running one compressor at full load and distributing 198mm
refrigerant to one heat exchanger, this control method
operates all compressors at part load and distributes
refrigerant to all of the heat exchangers which allows for • Small & slim design saves space RB unit (single type) RB unit (multi type)
the overall system efficiency to be improved. • A drain pipe is not required
• The control box position can be changed to meet the installation
conditions
Compressor Load level Easy to maintenance in a narrow space
High efficient operation Inefficient operation

Heat exchanger refrigerant control


Installation possible from either side for Installation possible on the
The heat exchanger in the outdoor unit is split into freedom of the control box upper-side for use in
narrow space
two parts (Top and Bottom). The efficiency of the heat • Maintenance can be • Electrics box can be
exchanger has been improved by adopting an optimum Fan • Small design saves space performed from the side. temporarily fixed by sliding
refrigerant path control where the refrigerant is distributed High efficient refrigerant flow control • A drain pipe is not required down.
more into the top heat exchanger as this is where there is a • Simple installation series connection design
greater air flow intake.
Large intake Larger • Parts can be replaced easily even at narrow
refrigerant
airflow flow space in the ceiling.
•2-way connection

Small intake
airflow Heat •Up to 2 units can be
EEV exchanger
Distributor connected in series. RB unit Ceiling

Heat exchanger
Outdoor unit

36 37
Outdoor units lineup
• Combinations other than the followings are not recommended.

Space saving combination Dimensions


8,10,12HP : AJHA72GALH / AJHA90GALH / AJH108GALH (Unit : mm)
22.4kW (8HP) 28.0kW (10HP) 33.5kW (12HP) 40.0kW (14HP) 45.0kW (16HP)

690 (Bolt pitch)

80 530
(Bolt pitch) 8-12 × 17 (Hole)

AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH


UNIT : AJHA72GALH UNIT : AJHA90GALH UNIT : AJH108GALH UNIT : AJH126GALH UNIT : AJH144GALH

732 (Bolt pitch)


50.4kW (18HP) 56.0kW (20HP) 61.5kW (22HP) 67.0kW (24HP) 73.0kW (26HP)

765 930

AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH


UNIT : AJHA90/A72GALH UNIT : AJHA90/A90GALH UNIT : AJH108/A90GALH UNIT : AJH108/108GALH UNIT : AJH144/90GALH

78.5kW (28HP) 85.0kW (30HP) 90.0kW (32HP) 95.0kW (34HP) 100.5kW (36HP)

1690
1576

1339
AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH
UNIT : AJH144/108GALH UNIT : AJH144/126GALH UNIT :AJH144/144GALH UNIT : AJH108/108/A90GALH UNIT : AJH108/108/108GALH

106.5kW (38HP) 112.0kW (40HP) 118.0kW (42HP) 123.5kW (44HP) 130.0kW (46HP)

B A C

AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH


UNIT : AJH144/108/A90GALH UNIT : AJH144/108/108GALH UNIT : AJH144/144/A90GALH UNIT : AJH144/144/108GALH UNIT : AJH144/144/126GALH 14,16HP : AJH126GALH / AJH144GALH (Unit : mm)

135.0kW (48HP) 1000 (Bolt pitch)


80 840 (Bolt pitch)
8-12×7 (Hole)

732 (Bolt pitch)


AJH432GALH
UNIT : AJH144/144/144GALH

765 1240

Energy efficiency combination

44.8kW (16HP) 62.4kW (22HP) 67.2kW (24HP) 72.8kW (26HP) 78.4kW (28HP)

1690
AJH144GALHH AJH198GALHH AJH216GALHH AJH234LALHH AJH252GALHH
UNIT : AJHA72/A72GALH UNIT : AJH126/A72GALH UNIT : AJHA72/A72/A72GALH UNIT : AJHA90/A72/A72LALH UNIT : AJHA90/A90/A72GALH

84.0kW (30HP) 90.4kW (32HP) 96.0kW (34HP) 102.4kW (36HP) 108.0kW (38HP)

B A C

AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH342GALHH A B C


UNIT : AJHA90/A90/A90GALH UNIT : AJH126/A90/A72GALH UNIT : AJH126/A90/A90GALH UNIT : AJH126/126/A72GALH UNIT : AJH126/126/A90GALH Front side knockout position Left side knockout position Bottom side knockout position
73 Ø 34.5
Power supply cable port Pipe port
43 Ø 43.7 Top view
113.0kW (40HP) 120.0kW (42HP) 125.0kW (44HP) Power supply cable port
Ø 50
Power supply Ø 22.2 Ø 34.5
Transmission cable port Ø 50 Power supply cable port
cable port

80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port

82
Ø 22.2
95

Ø 22.2
75

Pipe port Transmission Transmission


cable port cable port
42 197
10

AJH360GALHH AJH378GALHH AJH396GALHH


UNIT : AJH144/126/A90GALH UNIT : AJH126/126/126GALH UNIT : AJH144/126/126GALH 125
100

199

38 39
Outdoor units specifications

Space Saving Combination


Rating Capacity range HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

Model name AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH AJH432GALH
Unit 1 AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJHA90GALH AJHA90GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH
Unit 2 AJHA72GALH AJHA90GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH108GALH AJH108GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH
Unit 3 AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH
Maximum Connectable Indoor Unit*1 15 16 17 21 24 32 30 32 35 39 42 45 48 50 53 57 60 63 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.2-75.6 28.0-84.0 30.8-92.2 33.5-100.5 36.5-109.5 39.3-117.7 42.5-127.5 45.0-135.0 47.5-142.5 50.3-150.7 53.3-159.7 56.0-168.0 59.0-177.0 61.8-185.2 65.0-195.0 67.5-202.5

Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 67.0 73.0 78.5 85.0 90.0 95.0 100.5 106.5 112.0 118.0 123.5 130.0 135.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 75.0 81.5 87.5 95.0 100.0 106.5 112.5 119.0 125.0 131.5 137.5 145.0 150.0
Cooling 5.45 7.11 9.75 11.34 13.61 12.56 14.22 16.86 19.50 20.72 23.36 24.95 27.22 26.61 29.25 30.47 33.11 34.33 36.97 38.56 40.83
Input power kW
Heating 5.70 7.33 9.62 10.90 12.77 13.03 14.66 16.95 19.24 20.10 22.39 23.67 25.54 26.57 28.86 29.72 32.01 32.87 35.16 36.44 38.31
EER Cooling 4.11 3.94 3.44 3.53 3.31 4.01 3.94 3.65 3.44 3.52 3.36 3.41 3.31 3.57 3.44 3.50 3.38 3.44 3.34 3.37 3.31
W/W
COP Heating 4.39 4.30 3.90 4.13 3.92 4.34 4.30 4.07 3.90 4.05 3.91 4.01 3.92 4.01 3.90 4.00 3.91 4.00 3.91 3.98 3.92
Air flow rate High m3/h 11,100 11,100 11,100 13,000 13,000 11,100×2 11,100×2 11,100×2 11,100×2 13,000+11,100 13,000+11,100 13,000×2 13,000×2 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3

Sound pressure level*2 / Cooling 56 / 77 58 / 79 59 / 80 60 / 81 61 / 82 60 / 81 61 / 82 62 / 83 62 / 83 63 / 84 63 / 84 64 / 84.5 64 / 85 63 / 85 64 / 85 64 / 85 65 / 85.5 65 / 86 65 / 86 65 / 86 66 / 87


dB (A)
Power level Heating 58 / 80 59 / 81 61 / 83 61 / 83 61 / 83 62 / 84 62 / 84 63 / 85 64 / 86 63 / 85 64 / 86 64 / 86 64 / 86 65 / 87.2 65 / 87 65 / 87 66 / 87.7 65 / 87 66 / 88 66 / 88 66 / 88
Maximum external static pressure Pa 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
Compressor motor output kW 7.5 7.5 7.5 11.0 11.0 7.5×2 7.5×2 7.5×2 7.5×2 11.0+7.5 11.0+7.5 11.0×2 11.0×2 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Dimensions Width mm 930 930 930 1,240 1,240 930×2 930×2 930×2 930×2 1,240+930 1,240+930 1,240×2 1,240×2 930×3 930×3 1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×3 1,240×3
Depth 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765
Weight kg 262 262 262 286 286 262×2 262×2 262×2 262×2 286+262 286+262 286×2 286×2 262×3 262×3 286+262×2 286+262×2 286×2+262 286×2+262 286×3 286×3
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant
Charge kg(CO2eq-T) 11.8 (24.6) 11.8 (24.6) 11.8 (24.6) 11.8 (24.6) 11.8 (24.6) 11.8×2 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter Discharge Gas mm 15.88 19.05 19.05 22.22 22.22 22.22 22.22 28.58 28.58 28.58 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92
Suction Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
Operation range Heating ˚C -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Cooling/Heating -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21

Energy Efficiency Combination


Rating Capacity range HP 16 22 24 26 28 30 32 34 36 38 40 42 44

Model name AJH144GALHH AJH198GALHH AJH216GALHH AJH234GALHH AJH252GALHH AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH342GALHH AJH360GALHH AJH378GALHH AJH396GALHH
Unit 1 AJHA72GALH AJH126GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJH144GALH AJH126GALH AJH144GALH
Unit 2 AJHA72GALH AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH
Unit 3 AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH
Maximum Connectable Indoor Unit*1 24 33 36 39 42 45 48 51 54 57 60 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 31.2-93.6 33.6-100.8 36.4-109.2 39.2-117.6 42.4-126.0 45.2-135.6 48.0-144.0 51.2-153.6 54.0-162.0 56.5-169.5 60.0-180.0 62.5-187.5

Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 62.4 67.2 72.8 78.4 78.4 90.4 90.4 102.4 108.0 113.0 120.0 125.0
Capacity kW
Heating 50.0 70.0 75.0 81.5 88.0 88.0 101.5 101.5 115.0 121.5 126.5 135.0 140.0
Cooling 10.90 16.79 16.35 18.01 19.67 19.67 23.90 23.90 28.13 29.79 32.06 34.02 36.29
Input power kW
Heating 11.40 16.60 17.10 18.73 20.36 20.36 23.93 23.93 27.50 29.13 31.00 32.70 34.57
EER Cooling 4.11 3.72 4.11 4.04 3.99 3.99 3.78 3.78 3.64 3.63 3.52 3.53 3.44
W/W
COP Heating 4.39 4.22 4.39 4.35 4.32 4.32 4.24 4.24 4.18 4.17 4.08 4.13 4.05
Air flow rate High m3/h 11,100×2 13,000+11,100 11,100×3 11,100×3 11,100×3 11,100×3 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×2+11,100 13,000×3 13,000×3

Sound pressure level*2 / Cooling 59 / 80 61 / 82 61 / 82 62 / 83 62 / 83 63 / 84 63 / 84 64 / 85 64 / 85 64 / 86 65 / 86 65 / 86 65 / 86


dB (A)
Power level Heating 61 / 83 63 / 85 63 / 85 63 / 85 63 / 85 64 / 86 64 / 86 65 / 87 65 / 87 65 / 87 65 / 87 66 / 88 66 / 88
Maximum external static pressure Pa 80 80 80 80 80 80 80 80 80 80 80 80 80
Compressor motor output kW 7.5×2 11.0+7.5 7.5×3 7.5×3 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Dimensions Width mm 930×2 1,240+930 930×3 930×3 930×3 930×3 1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×2+930 1,240×3 1,240×3
Depth 765 765 765 765 765 765 765 765 765 765 765 765 765
Weight kg 262×2 286+262 262×3 262×3 262×3 262×3 286+262×2 286+262×2 286×2+262 286×2+262 286×2+262 286×3 286×3
Note : Specifications are based on the following conditions.
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Charge kg(CO2eq-T) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Liquid 12.70 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Connection pipe diameter Discharge Gas mm 22.22 28.58 28.58 28.58 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92
Suction Gas 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27
*1 : Minimum connectable indoor unit number is 2.
Cooling -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46 -10 to 46
*2 : The noise value is the value when measured in an anechoic room.
Operation range Heating ˚C -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
When measured in the actual installed state, surrounding noise and reflections are
Cooling/Heating -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 -10 to 21 received and the measured value is usually larger than the indicated value.

40 41
Features

HEAT PUMP TYPE Efficiency in actual operation


Top class high COP is realized for all combinations by our unique heat exchanger structure,
high efficient DC twin compressor, and other our own technologies.
(COP) 5 4.84
4.35 4.34 4.34 4.28
4.03 4.15 4.02 3.95
3.90 3.90 3.83 3.81 3.81 3.81 3.67 3.67 3.67 3.67
4 3.67 3.67 3.67 3.67 3.67
Space saving
Smart and cutting edge design combination 3
Extensive lineup from 8HP to 54HP in 2HP increment
Connectable indoor unit capacity ratio up to 150% 2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 (HP)

(COP) 5 4.84 4.84 For 24 HP Combination


4.55 4.52 4.63 4.61
4.42 4.45 4.30 4.34 Space saving Energy efficiency
4.21 4.11
4.03 3.89
System Outline Energy efficiency
4 3.77

combination 3
Excellent energy saving
Heat pump inverter type realizes the highly energy COP 17% UP
2
saving air conditioning for individual cooling and heating 16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)
operation by all inverter technology for seasonal efficiency.

High design flexibility for Energy saving technology that boosted operation efficiency
various building air conditioning
High design flexibly meets the various needs of high-rise Powerful large propeller fan
building air conditioning such as outdoor unit roof top By using CFD*1 technology, a newly designed fan achieves high performance
concentrated installation and each floor installation by and low noise operation. *1. CFD = Computational Fluid Dynamics
large capacity combination, sufficient connection capacity,
and high static pressure design.
3 phase DC fan motor
Efficiency is substantially improved by high efficient motor with sophisticated
driver control. In addition, low noise is realized by DC fan motor.
Easy installation and maintenance
The flexible communication method and piping
connections makes installation and maintenance easy Subcool heat exchanger
even for large systems. High Heat Exchange efficiency is achieved by using an internal projection
shape double pipe construction.

Sine-wave DC inverter control


High efficiency is realized by adoption of reduced switching loss IPM.

0.1Hz

High efficient & Large capacity

Capacity
Large Office System configuration example ALL DC inverter compressor
• This system is used for medium-sized and large buildings. Large capacity high efficient DC twin rotary compressor
Connecting each outdoor unit makes it possible to create a high- with 0.1Hz steps compressor speed control Inverter frequency
capacity system.
• Connection of multiple indoor units using separation tubes and 4-face heat exchanger
headers. Heat exchange efficiency is significantly improved by the introduction of a
new 4-face heat exchanger that increases effective surface area.

Outdoor unit
Front intake port (corner cut air inhaling structure)
Separation tube Header

Advanced energy saving control


Multiple outdoor operation control Heat exchanger refrigerant control
This control method operates all compressors at part load and The efficiency of the top and bottom heat exchanger in the outdoor
distributes refrigerant to all heat exchangers to improve the overall unit has been improved by adopting an optimum refrigerant path
Indoor unit
system efficiency. control.
Liquid pipe
Gas pipe High efficient refrigerant flow control
Fan

Larger
refrigerant flow
Large intake airflow

Indoor unit Small intake airflow


Compressor Load level EEV Heat exchanger
Heat exchanger Distributor
High efficient operation Inefficient operation Outdoor unit

42 43
Outdoor units lineup
• Combinations other than the followings are not recommended.

Space saving combination Dimensions


8,10HP : AJH072LALBH / AJH090LALBH (Unit : mm)
22.4kW (8HP) 28.0kW (10HP) 33.5kW (12HP) 40.0kW (14HP) 45.0kW (16HP)

690 (Bolt pitch)

80 530
(Bolt pitch) 8-12 × 17 (Hole)

AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH


UNIT : AJH072LALBH UNIT : AJH090LALBH UNIT : AJH108LALBH UNIT : AJH126LALBH UNIT : AJH144LALBH

732 (Bolt pitch)


50.0 kW (18HP) 56.0kW (20HP) 62.4 kW (22HP) 68.0 kW (24HP) 73.0 kW (26HP)

765 930

AJH162LALBH AJH180LALBH AJH198LALBH AJH216LALBH AJH234LALBH


UNIT : AJH162LALBH UNIT : AJH090/090LALBH UNIT : AJH126/072LALBH UNIT : AJH126/090LALBH UNIT : AJH144/090LALBH

78.0 kW (28HP) 85.0 kW (30HP) 90.0 kW (32HP) 95.0 kW (34HP) 100.0 kW (36HP)

1690
1576

1339
AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH
UNIT : AJH162/090LALBH UNIT : AJH144/126LALBH UNIT : AJH144/144LALBH UNIT : AJH162/144LALBH UNIT : AJH162/162LALBH

106.0 kW (38HP) 113.0 kW (40HP) 118.0 kW (42HP) 123.0 kW (44HP) 128.0 kW (46HP)

B A C

AJH342LALBH AJH360LALBH AJH378LALBH AJH396LALBH AJH414LALBH


UNIT : AJH162/090/090LALBH UNIT : AJH144/126/090LALBH UNIT : AJH144/144/090LALBH UNIT : AJH162/144/090LALBH UNIT : AJH162/162/090LALBH 12,14,16,18HP : AJH108LALBH / AJH126LALBH / AJH144LALBH / AJH162LALBH (Unit : mm)

135.0 kW (48HP) 140.0 kW (50HP) 145.0 kW (52HP) 150.0 kW (54HP) 1000 (Bolt pitch)
80 840 (Bolt pitch)
8-12×7 (Hole)

732 (Bolt pitch)


AJH432LALBH AJH450LALBH AJH468LALBH AJH486LALBH
UNIT : AJH144/144/144LALBH UNIT : AJH162/144/144LALBH UNIT : AJH162/162/144LALBH UNIT : AJH162/162/162LALBH

765 1240

Energy efficiency combination

44.8 kW (16HP) 50.4kW (18HP) 55.9 kW (20HP) 67.2 kW (24HP) 72.8 kW (26HP)

1690
AJH144LALBHH AJH162LALBHH AJH180LALBH AJH216LALBHH AJH234LALBHH
UNIT : AJH072/072LALBH UNIT : AJH090/072LALBH UNIT : AJH108/072LALBH UNIT : AJH072/072/072LALBH UNIT : AJH090/072/072LALBH

78.3 kW (28HP) 84.8 kW (30HP) 89.4 kW (32HP) 95.9 kW (34HP) 100.5 kW (36HP)

B A C

AJH252LALBHH AJH270LALBHH AJH288LALBHH AJH306LALBHH AJH324LALBHH A B C


UNIT : AJH108/072/072LALBH UNIT : AJH126/072/072LALBH UNIT : AJH108/108/072LALBH UNIT : AJH126/108/072LALBH UNIT : AJH108/108/108LALBH Front side knockout position Left side knockout position Bottom side knockout position
73 Ø 34.5
Power supply cable port Pipe port
43 Ø 43.7 Top view
107.0 kW (38HP) 113.5 kW (40HP) 120.0 kW (42HP) 125.0 kW (44HP) 130.0 kW (46HP) Power supply cable port
Ø 50
Power supply Ø 22.2 Ø 34.5
Transmission cable port Ø 50 Power supply cable port
cable port

80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port

82
Ø 22.2
95

Ø 22.2
75

Pipe port Transmission Transmission


cable port cable port
42 197
10

AJH342LALBHH AJH360LALBHH AJH378LALBHH AJH396LALBHH AJH414LALBHH


UNIT : AJH126/108/108LALBH UNIT : AJH126/126/108LALBH UNIT : AJH126/126/126LALBH UNIT : AJH144/126/108LALBH UNIT : AJH144/144/126LALBH 125
100

199

44 45
Outdoor units specifications

Space Saving Combination


Rating Capacity range HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54

Model name AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH180LALBH AJH198LALBH AJH216LALBH AJH234LALBH AJH252LALBH AJH270LALBH AJH288LALBH AJH306LALBH AJH324LALBH AJH342LALBH AJH360LALBH AJH378LALBH AJH396LALBH AJH414LALBH AJH432LALBH AJH450LALBH AJH468LALBH AJH486LALBH
Unit 1 AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH090LALBH AJH126LALBH AJH126LALBH AJH144LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH144LALBH AJH162LALBH AJH162LALBH AJH162LALBH
Unit 2 AJH090LALBH AJH072LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH126LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH090LALBH AJH126LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH144LALBH AJH144LALBH AJH162LALBH AJH162LALBH
Unit 3 AJH090LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH090LALBH AJH144LALBH AJH144LALBH AJH144LALBH AJH162LALBH
Maximum Connectable Indoor Unit*1 17 21 26 30 34 39 43 47 52 56 60 64 64 64 64 64 64 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 11.2-33.6 14.0-42.0 16.8-50.2 20.0-60.0 22.5-67.5 25.0-67.5 28.0-84.0 31.2-93.6 34.0-102.0 36.5-109.5 39.0-109.5 42.5-127.5 45.0-135.0 47.5-135.0 50.0-135.0 53.0-151.5 56.5-169.5 59.0-177.0 61.5-177.0 64.0-177.0 67.5-202.5 70.0-202.5 72.5-202.5 75.0-202.5

Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 22.4 28.0 33.5 40.0 45.0 50.0 56.0 62.4 68.0 73.0 78.0 85.0 90.0 95.0 100.0 106.0 113.0 118.0 123.0 128.0 135.0 140.0 145.0 150.0
Capacity kW
Heating 25.0 31.5 37.5 45.0 50.0 50.0 63.0 70.0 76.5 81.5 81.5 95.0 100.0 100.0 100.0 113.0 126.5 131.5 131.5 131.5 150.0 150.0 150.0 150.0
Cooling 5.20 7.28 8.96 10.96 13.01 16.56 14.56 16.16 18.24 20.29 23.84 23.97 26.02 29.57 33.12 31.12 31.25 33.30 36.85 40.40 39.03 42.58 46.13 49.68
Input power kW
Heating 5.17 7.25 8.65 11.17 13.63 13.63 14.50 16.34 18.42 20.88 20.88 24.80 27.26 27.26 27.26 28.13 32.05 34.51 34.51 34.51 40.89 40.89 40.89 40.89
EER Cooling 4.31 3.85 3.74 3.65 3.46 3.02 3.85 3.86 3.73 3.60 3.27 3.55 3.46 3.21 3.02 3.41 3.62 3.54 3.34 3.17 3.46 3.29 3.14 3.02
W/W
COP Heating 4.84 4.35 4.34 4.03 3.67 3.67 4.34 4.28 4.15 3.90 3.90 3.83 3.67 3.67 3.67 4.02 3.95 3.81 3.81 3.81 3.67 3.67 3.67 3.67

13,700+13,000+
Air flow rate High m3/h 11,100 11,100 13,000 13,000 13,700 13,700 11,100×2 13,000+11,100 13,000+11,100 13,000+11,100 13,700+11,100 13,700+13,000 13,700×2 13,700×2 13,700×2 13,700+11,100×2 13,700×2+11,100 13,700×2+11,100 13,700×2+11,100 13,700×3 13,700×3 13,700×3 13,700×3
11,100

Sound pressure level*2 / Cooling 56 / 77 58 / 79 57 / 78 60 / 81 62 / 83 63 / 84 61 / 82 61 / 82 62 / 83 63 / 84 64 / 85 64 / 85 65 / 88 66 / 87 66 / 87 65 / 86 65 / 86 66 / 87 66 / 87 67 / 87 67 / 88 67 / 88 67 / 88 68 / 89


dB (A)
Power level Heating 58 / 80 59 / 81 60 / 83 62 / 84 64 / 86 64 / 86 62 / 84 63 / 85 64 / 86 65 / 87 65 / 87 66 / 88 67 / 89 67 / 89 67 / 89 66 / 88 67 / 89 68 / 90 68 / 90 68 / 90 69 / 91 69 / 91 69 / 91 69 / 91
Maximum external static pressure Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5 7.5 11.0 11.0 11.0 11.0 7.5×2 11.0+7.5 11.0+7.5 11.0+7.5 11.0+7.5 11.0×2 11.0×2 11.0×2 11.0×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Dimensions Width mm 930 930 1,240 1,240 1,240 1,240 930×2 1,240+930 1,240+930 1,240+930 1,240+930 1,240×2 1,240×2 1,240×2 1,240×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×2+930 1,240×2+930 1,240×3 1,240×3 1,240×3 1,240×3
Depth 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765
Weight kg 252 252 275 275 275 275 252×2 275+252 275+252 275+252 275+252 275×2 275×2 275×2 275×2 275+252×2 275×2+252 275×2+252 275×2+252 275×2+252 275×3 275×3 275×3 275×3
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7
Charge kg(CO2eq-T) 11.7 (24.4) 11.7 (24.4) 11.8 (24.6) 11.8 (24.6) 11.8 (24.6) 11.8 (24.6) 11.7×2 (24.4×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×2 (24.6×2) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
(24.6+24.4) (24.6+24.4) (24.6+24.4) (24.6+24.4) (24.6+24.4×2) (24.6×2+24.4) (24.6×2+24.4) (24.6×2+24.4) (24.6×2+24.4)

Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm
Discharge Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -15 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

Energy Efficiency Combination


Rating Capacity range HP 16 18 20 24 26 28 30 32 34 36 38 40 42 44 46

Model name AJH144LALBHH AJH162LALBHH AJH180LALBHH AJH216LALBHH AJH234LALBHH AJH252LALBHH AJH270LALBHH AJH288LALBHH AJH306LALBHH AJH324LALBHH AJH342LALBHH AJH360LALBHH AJH378LALBHH AJH396LALBHH AJH414LALBHH
Unit 1 AJH072LALBH AJH090LALBH AJH108LALBH AJH072LALBH AJH090LALBH AJH108LALBH AJH126LALBH AJH108LALBH AJH126LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH AJH144LALBH AJH144LALBH
Unit 2 AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH AJH144LALBH
Unit 3 AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH072LALBH AJH108LALBH AJH108LALBH AJH108LALBH AJH126LALBH AJH126LALBH AJH126LALBH
Maximum Connectable Indoor Unit*1 34 39 43 52 56 60 64 64 64 64 64 64 64
Indoor unit connectable capacity Cooling kW 22.4-67.2 25.2-75.6 28.0-83.8 33.6-100.8 36.4-109.2 39.2-117.4 42.4-127.2 44.7-134.1 48.0-143.8 50.3-150.7 53.5-160.5 56.8-170.2 60.0-180.0 62.5-187.5 65.0-195.0

Power source 3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
Cooling 44.8 50.4 55.9 67.2 72.8 78.3 84.8 89.4 95.9 100.5 107.0 113.5 120.0 125.0 130.0
Capacity kW
Heating 50.0 56.5 62.5 75.0 81.5 87.5 95.0 100.0 107.5 112.5 120.0 127.5 135.0 140.0 145.0
Cooling 10.40 12.48 14.16 15.60 17.68 19.36 21.36 23.12 25.12 26.88 28.88 30.88 32.88 34.93 36.98
Input power kW
Heating 10.34 12.42 13.82 15.51 17.59 18.99 21.51 22.47 24.99 25.95 28.47 30.99 33.51 35.97 38.43
EER Cooling 4.31 4.04 3.95 4.31 4.12 4.04 3.97 3.87 3.82 3.74 3.70 3.68 3.65 3.58 3.52
W/W
COP Heating 4.84 4.55 4.52 4.84 4.63 4.61 4.42 4.45 4.30 4.34 4.21 4.11 4.03 3.89 3.77

13,000+ 13,000+ 13,000×2+ 13,000×2+


Air flow rate High m3/h 11,100×2 11,100×2 13,000+11,100 11,100×3 11,000×3 13,000×3 13,000×3 13,000×3 13,000×3 13,700+13,000×2 13,700×2+13,000
11,100×2 11,100×2 11,100 11,100

Sound pressure level*2 / Cooling 59 / 80 60 / 81 60 / 81 61 / 82 62 / 83 61 / 82 63 / 84 61 / 82 63 / 84 63 / 83 64 / 84 64 / 85 65 / 88 66 / 87 66 / 87


dB (A)
Power level Heating 61 / 83 62 / 84 62 / 85 63 / 85 63 / 85 64 / 86 65 / 87 64 / 87 65 / 88 65 / 88 65 / 88 66 / 88 67 / 89 68 / 90 68 / 90
Maximum external static pressure Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5×2 7.5×2 11.0+7.5 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Dimensions Width mm 930×2 930×2 1,240+930 930×3 930×3 1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×3 1,240×3 1,240×3 1,240×3 1,240×3 1,240×3
Note : Specifications are based on the following conditions.
Depth 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Weight kg 252×2 252×2 275+252 252×3 252×3 275+252×2 275+252×2 275×2+252 275×2+252 275×3 275×3 275×3 275×3 275×3 275×3
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Refrigerant 11.8+11.7 11.8+11.7×2 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7
Charge kg(CO2eq-T) 11.7×2 (24.4×2) 11.7×2 (24.4×2) 11.7×3 (24.4×3) 11.7×3 (24.4×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3) 11.8×3 (24.6×3)
(24.6+24.4) (24.6+24.4×2) (24.6+24.4×2) (24.6×2+24.4) (24.6×2+24.4)
*1 : Minimum connectable indoor unit number is 2.
Liquid 12.70 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm However ARXC72 and ARXC90 can be used signal connection.
Discharge Gas 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27
*2 : The noise value is the value when measured in an anechoic room.
Cooling -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range ˚C When measured in the actual installed state, surrounding noise and reflections are
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 received and the measured value is usually larger than the indicated value.

46 47
Features

HEAT PUMP TYPE Compact Design


This model is much more compact than conventional 12HP comparable
outdoor unit. Inconspicuous installation is available even on the roof.

Fujitsu General provides air conditioning systems


for a wide range of applications Model / 12HP class
from small office buildings and stores to large houses.
Height difference

1,428mm
16 %
System Outline
Space area
Compact Outdoor unit
The compact and low sound level enable the units to be
0.71m 2

installed to various environment with restriction and/or 27%


limited spaces such as mechanical rooms and or rooftops.

Small room application


Up to 30 indoor units can be connected by the optimum Current model
heat exchanger structure. Available to various small rooms.

Quiet design
Top class low sound operation has been achieved. This Advanced high efficiency technology
allows installation of the units to various places without a
special sound prevention work.

570mm
Large propeller fan DC inverter control
The high efficiency and the low sound Efficiency is improved by mounting of new
operation are mutually realized by active filter module.
reduction of a draft loss which are enabled
by the Fujitsu General's original blade
design and a large diameter propeller fan.
Small Office System configuration example
• This system is used for small and medium-sized buildings. 1
refrigerant system is used for each outdoor unit.
• Connection of multiple indoor units using separation tubes and
headers.
Subcool heat exchanger
Cooling performance is improved by
DC fan motor mounting of dual tube heat exchanger.
Miniaturized, low noise, high efficiency,

Pressure
Outdoor unit multi-stage DC fan motor is mounted.
effect

Separation tube Header

Cooling performance improved

Enthalpy

Indoor unit
Liquid pipe Scroll compressor
Gas pipe The equipment of scroll compressor with a
Large heat exchanger wide range of rotational frequency from 15
Heat exchange performance is substantially 15-120
20 rps to 120 rps together with Fujitsu General's
unique sensorless sine wave control method
improved by mounting of 2.6-row large
heat exchanger. which smoothly control the input power run
Indoor unit into the motor realized a mutual
improvement on the energy efficient
operation and the low sound operation.

48 49
Features

Long piping capability Specifications


Total pipe length
Our advanced refrigerant control technology allows us to
400m max.
Rating Capacity range HP 8 10 12
achieve a total refrigerant piping length of 400 m. This Model name AJH072LELAH AJH090LELAH AJH108LELAH
opens up new possibilities in system design. Maximum Connectable Indoor Unit 1-20 1-25 1-30

Power source 3-phase, ~400V, 50Hz


Actual piping length Height difference between Cooling 22.4 28.0 33.5
outdoor and indoor units
Capacity Nominal Heating kW 22.4 28.0 33.5
120m max. 50m max. Max Heating 25.0 31.5 37.5
Cooling 6.30 8.59 10.42
For the outdoor unit installed
below the indoor units: Input power Nominal Heating kW 4.65 6.61 8.18
40 m max. Max Heating 5.45 8.29 10.25
EER Cooling 3.56 3.26 3.22
Nominal Heating W/W 4.82 4.24 4.10
COP
Max Heating 4.56 3.80 3.66
Air flow rate m3/h 8,400 9,000 11,000
External static pressure(Max.) Pa 20 30 30
Sound pressure level / Cooling 52 / 66 54/69 59/73
dB (A)
Power level Heating 54 /- 57/- 61/-
Height 1,428 1,428 1,428
Dimensions Width mm 1,080 1,080 1,080
Depth 480 480 480

Up to 30 units can be connected Weight kg 170 177 178


Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant
The combination of the smallest but adequate capacity Charge kg(CO2eq-T) 7.0 (14.6) 7.5 (15.7) 7.5 (15.7)
indoor unit and a new outdoor unit with the optimum Connection pipe Liquid 9.52 9.52 12.70
mm
heat exchanger structure has realized the industry’s top diameter Gas 19.05 22.20 28.58
class connection of 30 units. Total pipe length 400 400 400
m
Max. Height difference 50/40 (Outdoor unit: Upper/Lower)
Cooling -15 to 46 -15 to 46 -15 to 46
Operation range ˚C
Piping length from first Heating -20 to 21 -20 to 21 -20 to 21
separation tube to the Height difference between
farthest indoor unit indoor and indoor units Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
90m max. 50m* max. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.

*: Only when new indoor units


and J-IIIL series are combined

High Static Pressure Dimensions


External static pressure is available up to 30 Pa. (only 12HP)
Models : AJH072LELAH / AJH090LELAH / AJH108LELAH (Unit : mm)

30 Pa 1080 480

196 688 196

1428
Top Class Low Operating Sound

480

516
Top class low operating sound is realized. Highly suited Sound Power level

38
to densely populated areas thanks to their low operating
sound.

66 dB(A) 77dB(A)

130
79

50
22
11dB(A)

Current model (8HP)

50 51
Features

HEAT PUMP TYPE Efficiency in actual operation


Top class high COP is achieved for all models by large heat exchanger,
high efficient DC twin compressor, and our own technologies.

High EER / COP ■EER / ■COP


[3-phase] [Single phase] 6HP class

5.01
Fujitsu General provides air conditioning systems 4.70
4.86 7 % UP
for a wide range of applications 4.33 4.41 4.51 8 % UP
4.17 4.23 4.23
4.05 3.92 3.95
from small office buildings and stores to large houses. 3.88
3.71 3.71
3.45

System Outline
High Energy Efficiency
Heat pump inverter control is used to achieve an efficient 4HP 5HP 6HP 4HP 5HP 6HP J-II J-III J-II J-III
cooling and heating operation in any indoor unit
combination.

Flexible systems for small- and Advanced high efficiency technology


medium-size buildings air conditioning
Space saving design and long piping design allow for
flexible installation on the roofs or balconies of small-
and medium-size buildings.
Multiple indoor units of various capacities and types can
be connected.

Large propeller fan DC inverter control


High performance and low noise realized by large Efficiency is improved by mounting of new
propeller and optimization of angle. active filter module.

DC fan motor
Miniaturized, low noise, high efficiency,
multi-stage DC fan motor is mounted.

Small Office System configuration example


• This system is used for small and medium-sized buildings. 1
refrigerant system is used for each outdoor unit. Subcool heat exchanger
Cooling performance is improved by
• Connection of multiple indoor units using separation tubes and mounting of dual tube heat exchanger.
headers.

Pressure
effect
Large heat exchanger
Outdoor unit
Heat exchange performance is substantially
improved by mounting of 3-row large heat
Separation tube Header
exchanger.

High efficiency DC twin rotary compressor Cooling performance improved


compressor motor Efficiency in all load regions is good. Especially good
performance from low to medium at normal operation. Enthalpy

Indoor unit Optimized refrigerant


High
Liquid pipe flow design
Gas pipe

Compressor
efficiency
Highly accurate parts
DC Twin Rotary compressor

Indoor unit

Compressor capacity High

52 53
Long piping capability Specifications
Total pipe length
Our advanced refrigerant control technology allows us
180m max.
Rating Capacity range HP 4 5 6 4 5 6
to achieve a total refrigerant piping length of 180m. This Model name AJH040LBLAH AJH045LBLAH AJH054LBLAH AJH040LELAH AJH045LELAH AJH054LELAH
opens up new possibilities in system design. Maximum Connectable Indoor Unit 1-9 1-10 1-13 1-9 1-10 1-13

Power source Single-phase, ~230V, 50Hz 3-phase, ~400V, 50Hz


Actual piping length Height difference between Cooling 12.1 14.0 15.5 12.1 14.0 15.5
outdoor and indoor units Capacity kW
Heating 13.6 16.0 18.0 13.6 16.0 18.0
120m max. 50m max. Input power
Cooling
kW
2.90 3.57 4.18 2.79 3.46 3.99
Heating 2.80 3.55 4.26 2.71 3.40 4.08
For the outdoor unit installed
below the indoor units: EER Cooling 4.17 3.92 3.71 4.33 4.05 3.88
40 m max. W/W
COP Heating 4.86 4.51 4.23 5.01 4.70 4.41
Air flow rate m3/h 6,200 6,400 6,900 6,200 6,400 6,900
Sound pressure level / Cooling 50 / 66 51 / 67 53 / 69 50 / 66 51 / 67 53 / 69
dB (A)
Power level Heating 52 / 68 53 / 69 55 / 71 52 / 68 53 / 69 55 / 71
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,334 1,334 1,334 1,334 1,334 1,334
Dimensions Width mm 970 970 970 970 970 970
Depth 370 370 370 370 370 370
Weight kg 117 117 119 119 119 119
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant
Charge kg(CO2eq-T) 4.8 (10.0) 5.3 (11.1) 5.3 (11.1) 4.8 (10.0) 5.3 (11.1) 5.3 (11.1)
Connection pipe Liquid 9.52 9.52 9.52 9.52 9.52 9.52
mm
diameter Gas 15.88 15.88 19.05 15.88 15.88 19.05
Total pipe length 180 180 180 180 180 180
m
Max. Height difference 50/40 (Outdoor unit: Upper/Lower) 50/40 (Outdoor unit: Upper/Lower)
Cooling -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21

Note : Specifications are based on the following conditions.


Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Piping length from first Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
separation tube to the Height difference between Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
farthest indoor unit indoor and indoor units The protective function may work when using it outside the operation range.

40m max. 15m max.


Dimensions

Models : AJH040LBLAH / AJH045LBLAH / AJH054LBLAH / AJH040LELAH / AJH045LELAH / AJH054LELAH (Unit : mm)

166 650 154

Non-stop oil recovery operation

43(Liquid)
51(Gas)
A comfortable room condition is maintained during oil recovery Previous model J-III series (Heating operation)

(410)
370
mode because the product continues to operate without

40
stopping the cooling or heating operation.

32
36
970 32 370 12

Operation stopped Non-stop oil


at oil recovery recovery operation Terminal blocks (Transmission)

ON ON

OFF
Time Time
Terminal blocks (Power)

1334
Easier Installation

1000
907
3-Way valve (Liquid)

Connection check function : Possible to confirm whether 3-Way valve (Gas)

111
wiring connection and address setting are correct by a

70
le port)

(Liquid valve)

(Gas valve)
ab
Ø28 (C
quick check run function.

297
279

120
21

25
95

155

142
131
87
Ø28 (Cable port) Ø28 (Cable port)

50

50

50
Ø28 (Cable port) 89 Pipe port 21 55 Ø28 (Cable port) 21 65 Ø28 (Cable port)
Pipe port Pipe port

A
Detail A
65 15
227
305

14
341

50
• Display connected indoor unit numbers
50
• Duplicately set address number of indoor unit can be 438 Pipe & cable port
displayed 622

54 55
Features

HEAT PUMP TYPE It Can be Easily Carried and


Installed Obscure Place
Small and light weight outdoor unit
This model is much more compact than conventional
6HP comparable outdoor units. Even when installed on
the balcony it fits within the height of the fence. The
compact size with a height of less than 1 m allows it to
be installed under windows and in tight spaces

Fujitsu General provides air conditioning systems Current model / 6 HP class


Height:1334 mm
for a wide range of applications Weight:117 kg
from small office buildings and stores to large houses.
Model / 6 HP class

Height difference

998 mm
▲25%
System Outline Low sound level design
Significantly low sound level is improved by using
Light weight
Space saving and low sound level design DC twin rotary compressor, inverter technology, and
Economical individual air conditioning is realized by ALL-DC 87 kg advanced airflow structure design.
technology, large capacity DC twin rotary compressor, and
Cooling 56
3-row heat exchanger though the size is compact.
dB(A)
54
53
Flexible systems for homes, shops,
small-size buildingss air conditioning 51
Due to compact size design and flexible piping design,
J-IIS series can be installed easily at the place where the 4 HP 5 HP 6 HP 6 HP
installation space is limited such as homes, shops, and small
Previous model
offices. Multiple indoor units of various capacities and types
can be connected.
Advanced high efficiency technology

Large propeller fan DC inverter control


High performance and low noise Efficiency is improved by mounting of
realized by large propeller and new active filter module.
optimization of angle.

Large Homes System configuration example


Low noise rubber

Outdoor unit
High efficiency
compressor motor
Separation tube Header DC fan motor
Miniaturized, low noise, high Optimized refrigerant
efficiency, multi-stage DC fan flow design
motor is mounted.
Highly accurate
parts

Indoor unit
Compact and
Liquid pipe high performance
Smooth airflow grille
Gas pipe
This grille was aerodynamically designed for
DC twin rotary compressor
good efficiency with little blow loss. Efficiency in all load regions is good.
Especially good performance from low
to medium at normal operation.
Indoor unit Large heat exchanger
Heat exchange performance is High
substantially improved by
mounting of 3-row large heat

Compressor
efficiency
exchanger.

High heat transfer


copper tube (Improved Compressor 100% High
lead angle) capacity

56 57
Features

Long Piping Length Specifications


Total pipe length
Our advanced refrigerant control technology allows us
80m max.
Rating Capacity range HP 4 5 6
to achieve a total refrigerant piping length of 80 m. This Model name AJH040LCLAH AJH045LCLAH AJH054LCLAH
opens up new possibilities in system design. Maximum Connectable Indoor Unit 7 8 8

Power source Single-phase, ~230V, 50Hz


Cooling 12.1 14.0 15.1
Actual piping length Capacity kW
Height difference between Heating 13.6 16.0 16.5
outdoor and indoor units
50m max.
Cooling 3.44 4.43 5.03
Input power kW
30m max. EER
Heating
Cooling
3.09
3.52
3.93
3.16
4.11
3.00
W/W
COP Heating 4.40 4.07 4.01
Air flow rate m3/h 4,040 4,200 4,200
Sound pressure level / Cooling 51 / 67 53 / 69 54 / 70
dB (A)
Power level Heating 54 / 68 55 / 69 56 / 70
Heat exchanger fin Blue fin Blue fin Blue fin
Height 998 998 998
Dimensions Width mm 970 970 970
Depth 370 370 370
Weight kg 86 86 87
Type (Global Warming Potential) R410A (2,088) R410A (2,088) R410A (2,088)
Refrigerant
Charge kg(CO2eq-T) 4.0 (8.4) 4.0 (8.4) 4.0 (8.4)
Connection pipe Liquid 9.52 9.52 9.52
mm
diameter Gas 15.88 15.88 15.88
Total pipe length 80 80 80
m
Max. Height difference 30 30 30
Cooling -5 to 46 -5 to 46 -5 to 46
Operation range ˚C
Heating -20 to 21 -20 to 21 -20 to 21

Piping length from first Note : Specifications are based on the following conditions.
separation tube to the Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
farthest indoor unit Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.

40m max.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
Height difference between The protective function may work when using it outside the operation range.
indoor and indoor units

15m max. Dimensions

Models : AJH040LCLAH / AJH045LCLAH / AJH054LCLAH (Unit : mm)

Non-stop oil recovery operation


A comfortable room condition is maintained during oil recovery mode Previous model J-IIS series (Heating operation)

because the product continues to operate without stopping the cooling *1


or heating operation. Top view

Operation stopped at oil recovery Non-stop oil recovery operation

ON ON

OFF

Time Time

Easier Installation
Connection check function : Possible to confirm whether Front view
wiring connection and address setting are correct by a Rear view
quick check run function. Side view

Bottom view
• Display connected indoor unit numbers
• Duplicately set address number of indoor unit can be
displayed Detail A

58 59
16 Types and 97 models available to meet
the requirements of any building design.

The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise

and to have user friendly operation. With a variety of indoor units and capacities

available, Fujitsu General has an indoor unit to match any requirement which is easy

to install and maintain.

Further, a variety of options are available to achieve an air conditioning environment

that is more desirable from the user’s perspective.

AIRSTAGE
TM INDOOR UNITS LINE-UP
4-way Flow Compact Cassette

INDOOR UNITS
4-way Flow Cassette
Circular Flow Cassette
Mini Duct
Slim Duct / Slim Concealed Floor
Low Static Pressure Duct / Concealed Floor
Medium Static Pressure Duct
High Static Pressure Duct
Large Airflow Duct
Compact Floor
Floor / Ceiling
Ceiling
Compact Wall Mounted / Wall Mounted

60 61
AIRSTAGE Indoor units
TM

INDOOR UNITS LINE-UP


Comprehensive range of indoor units of variety design and capacity ranges available which can be selected to suit any air conditioning needs.
16 types, 97 models, Capacity range from 1.1kW to 28.0kW

Indoor units range


Model code 4 7 9 12 14 18 24 30 34 36 45 54 60 72 90 96

Capacity range (kW) 1.1 2.2 2.8 3.6 4.5 5.6 7.1 9.0 10.0 11.2 12.5 14.0 18.0 22.4 25.0 28.0

4-way Flow Compact


AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH

(Slim type)
AUXD18GALH AUXD24GALH
4-way Flow

Cassette (Large type)


AUXA18GALH*3 AUXA24GALH*3 AUXA30GALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH

(Slim type)
AUXM018GLAH AUXM024GLAH AUXM030GLAH
Circular Flow

(Large type)
AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH

Mini Duct
(With drain pump)
ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH

Slim Duct
(With drain pump)
ARXD04GALH*3 ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH

Low Static Pressure Duct


ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH ARXB24GALH ARXB30GALH ARXB36GALH ARXB45GALH

Duct Medium Static Pressure Duct


ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH

High Static Pressure Duct


ARXC36GBTH ARXC45GATH ARXC60GATH*1 ARXC72GBTH*1 ARXC90GBTH*1 ARXC96GATH*1

(Compact type)

Large Airflow Duct ARXN018GLBH*4 ARXN024GTBH*4 ARXN030GTBH*4

(Large type)
ARXN18GATH*2 ARXN24GATH*2 ARXN30GATH*2 ARXN34GATH*2 ARXN36GATH*2 ARXN45GATH*2

Floor
(Same as Ceiling models)
ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH

Slim Concealed Floor


(Same as Slim Duct models)
ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
Floor
Concealed Floor
(Same as Low Pressure Static Duct
Models) ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH

Compact Floor
AGHA004GCAH AGHA007GCAH AGHA009GCAH AGHA012GCAH AGHA014GCAH

Ceiling Ceiling
ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH

Compact Wall Mounted (EEV internal)


ASHA07GACH ASHA09GACH ASHA12GACH ASHA14GACH

Wall Mounted
ASHA18GACH ASHA24GACH ASHA30GACH
Wall Mounted

ASHA004GTAH ASHA007GTAH ASHA009GTAH ASHA012GCAH ASHA014GCAH ASHA18GBCH ASHA24GBCH ASHA030GTAH ASHA034GTAH

*1: ARXC60/72/90/96G cannot be connected to J-IIS series and J-III series.


*2: Large Airflow Duct (Large type) can be connected to V-III series only.
*3: ARXD04GALH and AUXA18/24GALH can not be connected to J-IIIL series.
62 *4: Large Airflow Duct (Compact type) can be connected to J-IIIL series only.
63
AIRSTAGE Indoor units TM

4-way Flow Compact Cassette Compact design


Worlds first 24,000Btu model
570mm

570mm
High lift drain pump
Ceiling panel
in the compact cassette
Max.
category
(Easy installation by taking off 700mm
Models
ceiling panel of 600 x 600 size)
AUXB04GBLH
AUXB07GALH
AUXB09GALH
AUXB12GALH
Optional parts
AUXB14GALH
Air Outlet Shutter Plate : UTR-YDZB
AUXB18GALH Insulation Kit for High Humidity : UTZ-KXGC
AUXB24GALH Fresh Air Intake Kit : UTZ-VXAA

Specifications
Model name AUXB04GBLH AUXB07GALH AUXB09GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.1 5.0 6.3 8.0
2-stage turbo fan Quiet quality Input power W 23 25 25 29 35 36 84
High 530 540 550 600 680 710 1,030
High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and
Airflow rate Med m3/h 420 / 450*1 450 450 530 590 580 830
wing number (7 blades each)
An evenly spread air distribution across the heat Low 300 / 350*1 350 350 390 390 400 450
Designed by CFD-analysis (fluid) simulations
exchanger is possible due to the new 2 stage turbo fan High 34 34 35 37 38 41 50
Sound pressure dB
which produces two separate airflow streams. level
Med
(A)
28 / 30*1 30 30 34 34 35 44
Adoption of laminar wing Low 21 / 25*1 25 25 27 27 27 30
1-stage 2-stage turbo fan Laminar wing
Wind velocity Dimensions (H × W × D) mm 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570
Fast Quiet Airflow runs through smoothly
Heat exchange Weight kg 15 15 15 15 15 17 17
efficiency along the laminar wing
+
2-stage
= 20%UP
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 15.88 15.88
Slow Drain hose diameter (I.D./O.D.) 25 / 32
Model name UTG-UFGC-W
Previous turbo fan
In the case of a previous fan, the air outlet range was narrow as the Quiet Cassette Grille Dimensions (H×W×D) mm 50 × 700 × 700
airflow moved to the motor side which meant the velocity of air Spin direction Weight kg 2.6
passing through the heat exchanger was uneven. No airflow separation
Airflow direction Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Improvement of the airflow distribution High ceiling mode


The compact cassette can be installed up to a height of 3.0m
(12/14/18/24). Dimensions (Unit: mm)
1 The maximum height from floor to ceiling (m)
Model code 530 (Bolt pitch)
A Standard mode High ceiling mode
B 07 2.7 -

580-660 (Ceiling openings)


C 09 2.7 -

570 (Indoor unit)


D 3 12 2.7 3.0

540 (Bolt pitch)


14 2.7 3.0

700
18 2.7 3.0
2 24 2.7 3.0
Grille cover

75
1 Maintenance of fan motor and fan
Maintenance of the fan motor and fan can be done easily after taking
135 250
off the panel as the bell mouth of the fan can be removed easily. 700 Top view

A : Fan motor B : 2-stage turbo fan Bottom view 40 99


135 250
C : Bell-mouth D : Panel

116
30
49
102

262
2 Air filter : standard equipment

108

222
146

30
40
245
Side view

3 Adaptation of transparent drainage parts

124
58
Ceiling
During installation, maintenance and operation, the drain pump Control box
and kit can be checked easily. Liquid pipe Gas pipe Side view

64 65
AIRSTAGE Indoor unitsTM

4-way Flow Cassette One way


installation
High lift drain pump
Ceiling panel
Parallel Max.
apertures 850mm
Models (Slim type) Models (Large type)
AUXD18GALH AUXA18GALH
AUXD24GALH AUXA24GALH
AUXA30GALH
Optional parts
AUXA34GALH
IR Receiver Unit : UTY-LRHGB1
AUXA36GALH Air Outlet Shutter Plate : UTR-YDZK
AUXA45GALH Panel Spacer : UTG-BKXA-W
AUXA54GALH (Slim type)
(Large type) Insulation Kit for High Humidity : UTZ-KXRA
Wide Panel : UTG-AKXA-W
Fresh Air Intake Kit : UTZ-VXRA

Specifications
Model name AUXD18GALH AUXD24GALH AUXA18GALH AUXA24GALH AUXA30GALH AUXA34GALH AUXA36GALH AUXA45GALH AUXA54GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0
High efficiency turbo fan with 3-dimensional blade Input power W 39 46 51 51 59 77 80 99 119
High 1,150 1,280 1,420 1,420 1,600 1,750 1,800 1,900 2,000
High efficiency airflow distribution has been achieved by the introduction of a 3
Previous turbo fan Airflow rate Med m3/h 940 1,040 1,230 1,230 1,300 1,300 1,300 1,370 1,370
dimensional blade which increases the air passing over the heat exchanger.
Air passing through the heat exchanger was uneven and the air would only flow Low 870 870 1,100 / 1,000*1 1,100 / 1,000*1 1,100 1,100 1,100 1,100 1,100
close to the ceiling. High 36 38 40 40 40 43 44 46 47
500mm 450mm
Sound pressure
Med
dB
30 33 36 36 38 38 38 39 39
level (A)
Low 29 29 33 / 31*1 33 / 31*1 33 33 33 33 33
Previous blade
3-dimensional blade Dimensions (H × W × D) mm 246 × 840 × 840 246 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840
Weight kg 22 22 27 27 27 27 27 27 27
Heat exchanger Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Heat exchanger < Motor side > Separation pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05
< Motor side > phenomenon of Drain hose diameter (I.D./O.D.) 25 / 32
Wind velocity
Fast Quiet airflow
Model name UTG-UGGA-W
causes noise
No airflow separation Cassette Grille Dimensions (H×W×D) mm 50 × 950 × 950
Uneven airflow
Slow Weight kg 5.5
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
: Spin direction : Airflow direction : Turbulent flow noise Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Improvement of the airflow distribution


The louver design distributes Front part Ceiling
air leaving a space between the
chassis and the ceiling allowing far Dimensions (Unit : mm) ( ) : AUXD18 / AUXD24

and wide air flow distribution. IR receiver 796


(Option) 950
Hanging bolt position

Rear part

Hanging bolt position


Much less temperature irregularity

840 : Indoor unit

Ceiling opening
Bottom view Round louver happens by spreading airflow widely

860 to 910
950

699
420
Adjustment of hanger position is High ceiling mode

607
possible after installation This cassette can be installed up to a height of 4.2m (36/45/54). Drain hose
358
The maximum height from floor to ceiling (m) (Control) Box
Model code
Detachable Standard mode High ceiling mode 358 278 60
Grille corner 18 3.0 3.5 40
24 3.0 3.5

289(256)
30 3.2 3.6

200
34 3.2 3.6
Adjustment can be done
just taking off the corner part 36 3.2 4.2
142

142

10

140
45 3.2 4.2 Liquid pipe

44
Ceiling Gas pipe
54 3.2 4.2 Wire hole

66 67
AIRSTAGE Indoor unitsTM

Circular Flow Cassette


Models (Slim type) Models (Large type)
AUXM18GLAH AUXK18GLAH
AUXM24GLAH AUXK24GLAH
AUXM30GLAH AUXK30GLAH
AUXK34GLAH
AUXK36GLAH
AUXK45GLAH
AUXK54GLAH (Slim type)
(Large type)

Specifications
Model name AUXM018GLAH AUXM024GLAH AUXM030GLAH AUXK018GLAH AUXK024GLAH AUXK030GLAH AUXK034GLAH AUXK036GLAH AUXK045GLAH AUXK054GLAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 5.6 7.1 9.0 10.0 11.2 12.5 14.0
Capacity kW
Heating 6.3 8.0 10.0 6.3 8.0 10.0 11.2 12.5 14.0 16.0

Unique Circular Flow design Input power


High
W 20
1,050
25
1,120
49
1,470
40
1,420
40
1,420
47
1,440
47
1,440
61
1,620
89
1,820
116
2,040
New Cassette type realizes Circular Flow to blow Med-Hi 930 1,050 1,160 1,360 1,360 1,440 1,440 1,500 1,590 1,800
Med 900 930 1,070 1,300 1,300 1,340 1,340 1,400 1,500 1,590
large airflow in 360º direction by mounting high Ø7mm high density heat exchanger Airflow rate m3/h
Lo-Hi 870 900 930 1,270 1,270 1,300 1,300 1,340 1,400 1,440
performance DC fan motor, new turbo fan and Low 810 870 900 1,200 1,200 1,280 1,280 1,280 1,300 1,300
unique seamless airflow louver design. New DC fan motor Quiet 780 780 780 1,150 1,150 1,150 1,150 1,150 1,150 1,150
High 33 35 40 38 38 39 39 41 44 47
High efficient turbo fan
Med-Hi 32 33 36 37 37 38 38 40 42 45
Seamless airflow louver Sound pressure Med dB 31 32 34 36 36 37 37 38 40 42
level Lo-Hi (A) 30 31 32 35 35 36 36 37 38 39
Low 29 30 31 34 34 35 35 36 36 36
Quiet 28 28 28 33 33 33 33 33 33 33
Dimensions (H × W × D) mm 246×840×840 246×840×840 246×840×840 288×840×840 288×840×840 288×840×840 288×840×840 288×840×840 288×840×840 288×840×840
Weight kg 24.0 24.5 24.5 26.5 26.5 29.5 29.5 29.5 29.5 29.5
Uniform temperature air conditioning Connection Liquid (Flare) 6.35 9.52 9.52 6.35 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 15.88 15.88 12.70 15.88 15.88 15.88 15.88 15.88 15.88
Achieve a comfortable air conditioning spread to every Drain hose diameter (I.D./O.D.) 25 / 32
corner of the room by circular flow & wide vertical airflow. Model name UTG-UKGC-W / UTG-UKGA-B
Cassette Grille Dimensions (H×W×D) mm 53×950×950
Weight kg 6.0

orta ble! Note : Specifications are based on the following conditions. When AUX*018GLAH is connected to the outdoor unit other than J-IIIL, pipe diameter should

Comf
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB. be Ø9.52/Ø15.88 (Liq/Gas)
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB. When AUXK036GLAH, AUXK045GLAH, and AUXK054GLAH are connected to the outdoor unit
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V]. other than J-IIIL, gas pipe diameter should be Ø19.05.

Dimensions (Unit: mm)

Models: AUXM18 / AUXM24 / AUXM30 Models: AUXK18 / AUXK24 / AUXK30 / AUXK34


Individual louver control Human sensor increases more energy saving AUXK36 / AUXK45 / AUXK54
796 796
Each louver can be set individually by Touch Panel Wired Remote Energy saving operation starts automatically by detecting the motion Hanging bolt position Hanging bolt position
Human Human
Controller to enjoy the comfort of different directional airflows of a person. 2 modes of save operation mode and stop mode can be sensor sensor
IR receiver (option) IR receiver (option)
according to various room layouts. selected. (option) (option)

Hanging bolt position


Hanging bolt position
* Touch Panel Wired RC (UTY-RNRYZ2) only *Touch Panel Wired RC (UTY-RNRYZ2) only

Comfortable air conditioning by preventing


2 modes can be selected.

768
768

950
direct blowing of cold air and by providing
950

swinging air flow simultaneously.


Power is saved while
Auto saving people are away.

Operation stops after (Control) box Drain hose (Control) box


Auto OFF people go out. 950 840: Indoor unit 950
Drain hose
840: Indoor unit

Efficient air conditioning based on the


room layout

298
200-205

200
256
Human sensor
(Option) Ceiling Ceiling Liquid pipe

39
39
Liquid pipe
Gas pipe Wire hole Gas pipe

68 69
AIRSTAGE Indoor units
TM

Mini Duct 6-speed control*


Multistep airflow speed control allows
Low noise

20 dB(A)
Auto Louver Grille Kit (Option)
• Thin design provides a comfortable
this model to install in a quiet location. living environment over a wide area.
at 04 model • Automatic louver grille provides
6-Step Speed comfortable air conditioning all the
Models (With drain pump)
High way down to the floor and matches
ARXK04GCLH the interior design well. (Optional)
ARXK07GCLH Med-H

ARXK09GCLH Med
ARXK04 ARXK07 ARXK09 ARXK12 ARXK14 ARXK18
ARXK12GCLH Med-L
Optional parts
ARXK14GCLH Low Remote Sensor Unit : UTY-XSZX
ARXK18GCLH IR Receiver Unit : UTB-YWC
Quiet
ARXK24GCLH Auto Louver Grille Kit : UTD-GXTA-W (for ARXK04/07/09/12/14GCLH)
* Compatible Remote Controller is as follows:
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 UTD-GXTB-W (for ARXK18GCLH)
UTD-GXTC-W (for ARXK24GCLH)

ARXK24

Specifications
Model name ARXK04GCLH ARXK07GCLH ARXK09GCLH ARXK12GCLH ARXK14GCLH ARXK18GCLH ARXK24GCLH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Large living space available Input power W 26 28 28 35 66 73 80
High 460 460 460 550 760 930 1,160
• Installation space can be reduced down to minimum Med-H 440 − − − − − −
depth 450mm height 198 mm and compact design (Unit: mm)
Airflow rate
Med
m3/h
420 420 420 480 560 740 960
• Minimum size: Depth 450mm, Height 198mm Volume Med-L 400 − − − − − −
Low 370 370 370 410 410 540 750
30% down compared with current model
Quiet 340 − − − − − −
• Lightweight: 16kg 10%down
Static pressure range 0 to 30 0 to 30 0 to 30 0 to 30 0 to 50 0 to 50 0 to 50

450
Pa
Standard static pressure 10 10 10 10 15 15 15
High 25 26 26 29 34 33 32
Med-H 24 25 25 27 31 30 30

198 225*
Sound pressure
level
Med
Med-L
Low
dB
(A)
23
22
21
24
23
22
24
23
22
26
25
24
28
26
24
28
26
24
28
27
25
Quiet 20 21 21 22 22 22 22
Dimensions (H × W × D) mm 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 900 × 450 198 × 1,100 × 450
600* Weight kg 14.5 15.5 15.5 16 16 19 22.5
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 9.52 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
*: Minimum installation dimension
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Optimum airflow path and low noise operation Easy design and maintenance for drain Dimensions (Unit: mm)

775 52
Low noise is realized drastically by stabilized airflow design By using the DC fan motor, it is possible to change the static pressure
range from 0 to 50 Pa*.

174
The change of static pressure range is possible by remote controller.

153
72
*: 0 to 30 Pa. (12) Rear view

Built-in drain pump as standard : Drain port


Maintenance is easy
Air Stabilizer

295
30

450
Parts can be replaced from the

150
182
193
10
side of the body where
maintenance is easier 1 Refrigerant pipe flare connection (Liquid)
View A

30
A
B 49 2 Refrigerant pipe flare connection (Gas)
High efficient DC fan motor
Lower power consumption C 56 78 3 Drain hose connection
49 66
Top view Side view
85 92
V-shape heat exchanger
169 ARXK04-14 ARXK18 ARXK24

57
43
A P100×6=600 P100×8=800 P100×10=1000
198
168
150 B 650 850 1050
78
(Drain hose) C 752 952 1152
33
D D 650 850 1050
E
E 665 864 1064
F
F 700 900 1100
Front view

70 71
AIRSTAGE Indoor units
TM

Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize
Optional parts
Remote Sensor Unit : UTY-XSZX
IR Receiver Unit : UTB-YWC
with luxury interior.
Auto Louver Grille Kit : UTD-GXTA-W (for ARXD04/07/09/12/14GALH)
Slim Duct Auto Louver Grille UTD-GXTB-W (for ARXD18GALH)
Models (With drain pump) UTD-GXTC-W (for ARXD24GALH)
ARXD04GALH
ARXD07GALH
ARXD09GALH ARXD04 ARXD07 ARXD09 ARXD12 ARXD14 ARXD18

ARXD12GALH
ARXD14GALH
ARXD18GALH
ARXD24GALH ARXD24
Wired Remote Wireles Remote
Controller Controller
Slim Concealed Floor

Specifications
Model name ARXD04GALH ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.5 5.6 7.1
Capacity kW
Heating 1.3 2.8 3.2 4.0 5.0 6.3 8.0
Slim design Selectable with a wide range of Input power W 38 44 50 54 92 83 122

With a slim indoor design, this indoor can static pressure High 510 550 600 600 800 940 1,330
Airflow rate Med m3/h 400 / 470*1 490 550 510 710 840 1,240
be installed in narrow ceiling spaces. By using DC fan motor, it is possible to Low 320 / 440*1 440 480 450 610 750 1,100

Drain port change of static pressure range 0 to 90Pa. Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50
Pa
The change of static pressure range is Standard static pressure 25 25 25 25 25 25 25
possible by remote controller. Static pressure range High 26 28 29 30 34 34 35
Height Sound pressure dB
198mm 0 to 90 Pa level
Med
(A)
21 / 25*1 25 26 27 32 32 32
Low 20 / 22*1 22 24 24 28 28 29
*24 model is 0 to 50Pa Dimensions (H × W × D) mm 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 900 × 620 198 × 1,100 × 620
Drain pump
Drain pump Weight kg 17 17 17 18 18 22 26
built-in
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 15.88 15.88
High lift drain pump Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *1: This value is under cooling operation.
Air-intake Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Max. Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Air intake direction can be selected
to match the installation site. 850mm

Drain hose is standard accessory


Dimensions (Unit: mm)

Bottom side Back side *Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Filter (Accessory) 51 G

174
152
71
30
ARXD04 / 07 / 09 / 12 / 14 / 18 ARXD24
Flexible installation Filter
(2pcs.)
Filter
(3pcs.)

(Bolt pitch)
377
Ceiling concealed 82

48
30

F E
(All surroundings) D
C
(Bolt pitch) ARXD04-14 ARXD18 ARXD24
10
Floor concealed 43 A 700 900 1100

163
119
198
168

89
78
55
47
78

B 650 850 1050


C 734 934 1134
31 69 D 650 850 1050
B 144
E P100x6=600 P100x8=800 P100x10=1000
A 264
367
F 18xØ5 22xØ5 26xØ5
620 G 574 774 974

72 73
AIRSTAGE Indoor unitsTM

Low Static Pressure Duct / Concealed Floor Compact design


Ultra-slim duct air conditioner for easy installation
Flexible installation

Ceiling concealed
Models Height

ARXB07GALH 217mm
ARXB09GALH
ARXB12GALH Slim size (217mm) allows installation even where the space
above the ceiling is narrow.
ARXB14GALH
ARXB18GALH ARXB07GALH
ARXB09GALH
ARXB12GALH
ARXB14GALH
ARXB18GALH Floor concealed

Two-direction drain piping


Concealed Floor

Filter (Accessory)
ARXB07 / ARXB09 ARXB12 / ARXB14 / Filter
Filter ARXB18 (3pcs.)
Low noise level (2pcs.)
Low static pressure
A low noise level has been achieved for each capacity Normal mode Duct indoor unit
mode
Two-direction drain piping
Airflow drop

Airflow
prevention

Air-intake
Low noise
Model 79 12 14 18 Air intake direction can be selected to match the installation site.
realized
Static pressure
Pa 0 to 50
range
Optional parts
Noise level dB(A) 24 27 25 30 30
(Low speed) Remote Sensor Unit : UTY-XSZX
Static pressure (Pa) IR Receiver Unit : UTB-YWC
Bottom side Back side Drain Pump Unit : UTZ-PX1BBA

Specifications Dimensions (Unit: mm)


Model name ARXB07GALH ARXB09GALH ARXB12GALH ARXB14GALH ARXB18GALH Models: ARXB07 / ARXB09 / ARXB12 / ARXB14 / ARXB18 886 (596)

*Service accessibility must be allowed for when installing the product.


Power source 230V ~, 50Hz
Please consult the installation manual for the necessary service access size.
Capacity Cooling 2.2 2.8 3.6 4.5 5.6

170
kW
Heating 2.8 3.2 4.0 5.0 6.3
Input power W 46 55 63 90 96 886 (596) 217
Control box
Airflow rate High 590 (164) (Bolt pitch) 194
370 (103) 440 (122) 800 (222) 890 (247)
3
m /h
Med (I/s) 310 (86) 370 (103) 500 (139) 750 (208) 810 (225)
1
Low 280 (78) 340 (94) 450 (125) 700 (194) 730 (203)

(Bolt pitch)
Brackets
3

390
Static pressure range 0 to 50 0 to 50 0 to 50 0 to 50 0 to 50 Brackets
Pa 2

587
595
Standard static pressure 25 25 25 25 25

364
Sound pressure level High 29 31 30 33 36
dB(A)

65 75
Med 26 29 28 32 34
166

Low 24 27 25 30 30
mm 24 47
Dimensions (H x W x D) 217 x 663 x 595 217 x 953 x 595
20

850 (560) 85 Airflow outlet


kg 150
Weight 15 22 23
Connection Liquid (Flare) ø6.35 ø9.52 953 (663)
pipe diameter 94 (50) Control box
Gas (Flare) mm ø12.70 ø15.88 600 (400)
10

Drain hose VP25[ø25(I.D.); ø32(O.U.)]


1 Refrigerant piping flare connection (Gas)
150

Note : Specifications are based on the following conditions.


217

2 Refrigerant piping flare connection (Liquid)


3 Drain piping connection

74 75
AIRSTAGE Indoor units
TM

Medium Static Pressure Duct Two-direction


drain piping
Installation styles
Embedded in Ceiling Hanging from Ceiling

Models (Low Static Pressure Duct)


ARXB24GATH
ARXB30GATH Duct indoor unit

ARXB36GATH Two-direction drain piping

ARXB45GATH
Easy setting by using remote controller Optional parts
Models (Medium Static Pressure Duct) Remote Sensor Unit : UTY-XSZX Flange (Round) : UTD-RF204
The change of static pressure
ARXA24GBLH range is possible by remote
Long Life Filter : UTD-LF25NA IR Receiver Unit : UTB-YWC
ARXA30GBLH Flange (Square) : UTD-SF045T Drain Pump Unit : UTZ-PX1NBA
controller
ARXA36GBLH
ARXA45GBLH

Specifications
Model name ARXB24GALH ARXB30GALH ARXB36GALH ARXB45GALH ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH
Feature Power source Single - phase, ~230V, 50Hz Single - phase, ~230V, 50Hz
Cooling 7.1 9.0 11.2 12.5 7.1 9.0 11.2 12.5
Capacity kW
Heating 8.0 10.0 12.5 14.0 8.0 10.0 12.5 14.0
Slim & Compact design Input power W 145 198 253 338 94 108 194 240
1,200 1,135mm High 1,100 1,410 1,710 1,970 1,280 1,410 1,840 1,970
In the case of bottom return air connection, not only does the
Control box is now included as Airflow rate Med m3/h 920 1,280 1,600 1,790 990 1,280 1,600 1,860
indoor unit design allow for installation in a narrow ceiling
part of the main chassis Low 810 1,150 1,470 1,670 840 1,150 1,470 1,640
space of up to 270mm, Further space savings have been
Static pressure range 0 to 80 0 to 80 0 to 80 0 to 80 0 to 150 0 to 150 0 to 150 0 to 150
achieved by mounting the electrical control box internally Standard static pressure
Pa
270mm 40 50 50 60 40 50 50 60
inside the chassis. High 31 34 37 41 31 34 37 41
Sound pressure dB
Med 27 32 35 38 27 32 35 38
level (A)
Low 25 29 33 36 23 29 33 36
One touch operating and easy to Dimensions (H × W × D) mm 270 × 1,135 × 700 270 × 1,135 × 700
install long life filter (Optional Parts)
Weight kg 39 42 42 42 36 40 40 40
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 19.05 19.05 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32 25 / 32
Low energy consumption by high Easy maintenance Note : Specifications are based on the following conditions.

efficiency DC fan motor See below for the case of rear suction type
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Improved motor efficiency 1
from previous model. Previous model 3

24 model 30 / 36 / 45 model

Dimensions (Unit: mm)


2
*Service accessibility must be allowed for when installing the product.
Can be installed for various location Large bottom
Please consult the installation manual for the necessary service access size. 1177(Bolt pitch) 114
panel: 1 piece 270 66
It can be installed in such locations as Outlet

168
32 32
high-rise condominiums by low static ø200
(knock 1
pressure design. out hole)

240
240
138 264 264 264

281
New model 1 3

447(Bolt pitch)
82

138

700
4
It can also be installed in wide spade 3
2
when high static pressure is required,
such as for offices.

161
75

173
3 ø205 hole
1.Control box 2
2.Fan casing Front view
3.Fan
Bottom panel: P.C.D. ø225
4.Motor 240
2 pieces 1015 107
270
121 1135

Selectable with a wide range of static pressure Top view


Side view (L) Side view (R)
It is possible to change of static pressure Structural improvement is attained by making the bottom panel two pieces, front
range 0 to 150Pa. Static pressure range and rear. The internal fan casing is also manufactured in two pieces, namely
1 Refrigerant piping flare connection (Liquid) :
upper and lower. The maintenance of the motor and fan can be easily carried out
0 to 150 Pa by removing the rear panel and the lower part of the casing while leaving the 2 Refrigerant piping flare connection (Gas) :
Rear view
main chassis installed. 3 Drain piping connection (Drain pipe)

76 77
AIRSTAGE Indoor units
TM

High Static Pressure Duct Easy installation (Compact size & Lightweight)
A compact size and lightweight (Unit:mm)
indoor unit has been developed
by reducing the basic chassis
Models Models and the overall material weight.

400

550
Models

450
ARXC36GBTH ARXC72GBTH ARXC96GATH
ARXC45GATH ARXC90GBTH 1,050 500 1,587 700
1,587 700
ARXC60GATH (ARXC36 / 45 / 60 type) (ARXC72 / 90 type) (ARXC96 type)

ARXC36 ARXC45 ARXC60 ARXC72 ARXC90

Optional parts
Long-Life Filter : UTD-LF60KA (For ARXC36 / 45 / 60)
IR Receiver Unit : UTB-YWC
Remote Sensor Unit : UTY-XSZX

ARXC96

Specifications
Model name ARXC36GBTH ARXC45GATH ARXC60GATH* ARXC72GBTH* ARXC90GBTH* ARXC96GATH*
Feature Power source Single - phase, ~230V, 50Hz
Cooling 11.2 12.5 18.0 22.4 25.0 28.0
Capacity kW
Heating 12.5 14.0 20.0 25.0 28.0 31.5
Static pressure selection Input power W 207 715 730 681 819 838
High 1,990 3,500 3,500 3,900 4,300 4,850
By using DC fan motor, it is possible to change static pressure range from 0 to 200Pa (ARXC36) / 300Pa (ARXC72 / 90 / 96).
Airflow rate Med m3/h 1,680 3,000 3,000 3,300 4,000 4,250
Low 1,330 2,460 2,460 3,000 3,500 3,600
[Pa]
Static pressure range 0 to 200 100 to 250 100 to 250 0 to 300 0 to 300 0 to 300
200 or 300 MAX. Pa
Standard static pressure 100 100 100 150 150 150
200 Pa High 42 49 49 47 48 48
Sound pressure dB
Med 36 45 45 43 46 45
(ARXC36 / 45 / 60 type) level (A)
Low 32 42 42 40 44 42
Dimensions (H × W × D) mm 400 × 1,050 × 500 400 × 1,050 × 500 400 × 1,050 × 500 450 × 1,587 × 700 450 × 1,587 × 700 550 × 1,587 × 700
MAX. Weight kg 40 46 46 84 84 105

300 Pa Connection
pipe diameter
Liquid
Gas mm
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
9.52 (Flare)
19.05 (Flare)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
12.70 (Brazing)
22.22 (Brazing)
(ARXC72 / 90 type) Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. *: ARXC60/72/90/96G cannot be connected to J-III series.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
MAX. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
0
[m3/h]
300 Pa Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Air flow rate (ARXC96 type)

Low noise Low energy consumption by high Dimensions (Unit: mm)


Models : ARXC36 / ARXC45 / ARXC60 efficiency DC fan motor Models: ARXC36 / ARXC45 / ARXC60 Models: ARXC72 / ARXC90 Models: ARXC96 60
MAIN
60 2 DARAIN 49
Cutting off the corners of the conventional indoor unit front panel and Improved motor efficiency 88
1
2
MAIN
DARAIN
PORT
49 SAFETY DARAIN PORT
1 PORT SAFETY DARAIN PORT

fan casing, has enabled less turbulent air flow. Low noise is realized from previous model.

527
427

504
404
by adopting a plastic case and a plastic fan.

411
311

327
227
71 Rear view 81 Rear view 81
Rear view

42
42
371 1587 1587
400 1,080(Bolt pitch) 356 450 8 1410(BOLT PITCH) 550 1410 (BOLT PITCH)
324 1,000 208 370 15 470 15 8
14 1250 149 1250 149

38
862 108 65 65

38

29
123
139
(ARXC36 type) (ARXC72 / 90 / 96 type)

653(BOLT PITCH) 29
41
New model

653(BOLT PITCH)
25
50
500(Bolt pitch)

50
25
1

700

700
585

2
(ARXC36GBTH)

50
25
3

50
25
4 P160×2 Ø3 150×7=1050 75 P160×2 P150×7=1050 75
Side view (R) =320 15 Side view (R) =320 15 1200 125
851 1200 125
295 350 35 1450 117 350 35 1450 117
1,050 85
Side view (L) Top view Side view (L) Top view Side view (L) Top view

ARXC36GBTH : Plastic fan [42dB(A)]


500mm
* Model : Material Heat exchanger (Drain hose) (Drain hose)
Plastic fan
(At 100Pa : Actual noise Ø 225mm Front view Front view
Front view
measurement value)
Casing (Plastic)
400mm

1 Refrigerant piping flare connection (Liquid) 1 Refrigerant pipe flare connection (Liquid) 1 Refrigerant pipe flare connection (Liquid)
2 Refrigerant piping flare connection (Gas) 2 Refrigerant pipe flare connection (Gas) 2 Refrigerant pipe flare connection (Gas)
3 Drain piping connection 3 Drain hose 3 Drain hose

78 79
AIRSTAGE Indoor units
TM

Large Airflow Duct (Compact type)


Models Models
ARXN018GLBH ARXN024GTBH
ARXN030GTBH

ARXN018

ARXN024 ARXN030

Specifications
Model name ARXN018GLBH ARXN024GTBH ARXN030GTBH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0
Capacity kW
Heating 6.3 8.0 10.0
Large airflow volume Input power W 173 180 273
High 1,720 2,100 2,700
It can be installed in places such as early replacement of air Med-H - 2,050 2,390
required by large airflow volume. Airflow rate
Med
m3/h
1,470 1,860 2,080
Med-L - 1,660 1,770
Low 1,360 1,470 1,470
Quiet - 1,260 1,260
Static pressure range 0 to 80 0 to 100 0 to 100
Pa
Standard static pressure 50 50 50
High 36 37 41
Med-H - 35 38
Sound pressure Med dB 33 33 34
level Med-L (A) - 31 31
Low 30 28 28
Quiet - 26 26
Dimensions (H × W × D) mm 270 × 1,135 × 700 300 × 1,400 × 700 300 × 1,400 × 700
Weight kg 40 48 48
Connection Liquid (Flare) 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 15.88 15.88
Slim & Compact design Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
It can be installed in places such as early replacement of air required Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
by large airflow volume. Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
(unit: mm) Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Dimensions
270 300
(Unit: mm)

Models: ARXN018 Models: ARXN024 / ARXN030

1177(Bolt pitch) 114 1440


270 66

168
Outlet 1295
32 32
ARXN018 ARXN024 / 030 ø200
Ø125
(knock 1
out hole)

240
240

281
3 Gas pipe

447(Bolt pitch)
Liquid pipe

Quiet operation

631

700
700
3
2 Air
Multistep airflow speed control allows this model
161

173
to install in a quiet location. Low noise
6-Step Speed
26 dB(A)
P.C.D. ø225 1015 107 240 1162
121 1135 270 Drain port Drain port
High 1400
Side view (L) Top view Side view (R) Side View (L) Top View Side View (R)
98
at 024/030 models Med-H

217
Med
Rear view Front View
Med-L

Low 1 Refrigerant piping flare connection (Liquid) :


2 Refrigerant piping flare connection (Gas) :
Quiet 3 Drain piping connection (Drain pipe)

80 81
AIRSTAGE Indoor units
TM

Large Airflow Duct (Large type)


Models
ARXN18GATH
ARXN24GATH
ARXN30GATH
ARXN34GATH
ARXN36GATH
ARXN45GATH

Specifications
Model name ARXN18GATH ARXN24GATH ARXN30GATH ARXN34GATH ARXN36GATH ARXN45GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0 11.2 12.5
Capacity kW
Heating 6.3 8.0 10.0 11.2 12.5 14.0
Large airflow volume Input power W 154 205 306 432 572 572
High 2,280 2,640 3,200 3,720 4,120 4,120
It can be installed in places such as early replacement of air
Airflow rate Med m3/h ― ― ― ― ― ―
required by large airflow volume.
Low ― ― ― ― ― ―
Static pressure range 50 to 100 50 to 150 50 to 250 50 to 250 50 to 300 50 to 300
Pa
Standard static pressure 50 50 50 50 60 60
High 35 37 40 43 45 45
Sound pressure dB
Med ― ― ― ― ― ―
level (A)
Low ― ― ― ― ― ―
Dimensions (H × W × D) mm 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700
Weight kg 84 84 84 84 84 84
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions. Large Airflow Duct can be connected to V-III series only.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Installation styles Selectable with a wide range of


static pressure
Dimensions (Unit: mm)

Rear view

static pressure range static pressure range

50 to 250 Pa 50 to 300 Pa
(30 / 34class) (36 / 45class) Air Flow

Top view

Optional parts
Remote Sensor Unit : UTY-XSZX Front view

82 83
AIRSTAGE Indoor units TM

Compact floor
Models (EEV internal)
AGHA004GCAH
AGHA007GCAH
AGHA009GCAH
AGHA012GCAH
AGHA014GCAH

Specifications
Model name AGHA004GCAH AGHA007GCAH AGHA009GCAH AGHA012GCAH AGHA014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8 3.6 4.0
Capacity kW
Heating 1.3 2.8 3.2 4.0 4.5
2-Fan & Wide airflow Flexible & easy installation Input power W 12 / 14 16 17 22 29
High 380 / 430 470 500 590 670
Individual vertical airflow by 2-fan can control the whole room Due to compact and whole surface suction method model, floor, Med-H 350 420 450 520 590
comfortably. concealed, half concealed, or wall mounted installation can be Med 320 390 400 470 520
Airflow rate m3/h
available to match the room layout. Med-L 310 360 360 420 450
Low 280 330 330 390 390
Cooling Prevents cold air Beneath standard window Standard concave portion Quiet 210 270 270 340 340
from falling
(unit:mm) Min.900
High 35 / 36 37 38 42 46
Med-H 33 35 36 39 42

Min. Sound pressure Med dB 31 33 34 37 39


700 level Med-L (A) 30 31 31 35 36
600
700 Low 28 29 29 33 33
at operation at stable Quiet 22 22 22 30 30
start operation
Dimensions (H × W × D) mm 600×740×200 600×740×200 600×740×200 600×740×200 600×740×200
740 (unit:mm) Weight kg 15 15 15 15 15
200
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35
Heating Window Wall
Half concealed pipe diameter Gas (Flare) mm 9.52 9.52 9.52 12.70 12.70
(Optional parts necessary)
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
Prevents cold (unit:mm) (unit:mm)
draft from EV Kit (option) - - - - -
Min.
window 590
Note : Specifications are based on the following conditions. When AGH*004GCAH, AGH*007GCAH, and AGH*009GCAH are connected to the outdoor unit
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. other than J-IIIL, gas pipe diameter should be Ø12.70.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

at stable
operation Min. 730 Max.
Max. 150 80 Dimensions (Unit: mm)

200

Quiet operation Flexible piping connection


Quiet operation is realized by 6 fan speed control.
Low noise
6 direction of drain & piping
(via 2 wire controller) 22 dB(A)
Drain horse and piping can be drawn flexibly in the right, left, side,
at 004/007/009 and down directions
models
6-Step Speed
High

600
Med-H
Back view
Med

Med-L
1 6
Low
2 5
Quiet 3 Drain hose 4
Piping 740
* Compatible Remote Controller is as follows:
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 Front view Side view

84 85
AIRSTAGE Indoor units
TM

Floor / Ceiling Compact design


Symmetrical, slim and compact design.
Auto-closing louvre
When operation is stopped, the louvres will automatically close.
(Unit : mm) (This function is available on all non-ducted models.)

Models
ABHA12GATH
ABHA14GATH Super vane
ABHA18GATH 655 Double Louvre Super vane with newly developed special
ABHA24GATH configuration boosts airflow sending cool air quickly to every corner
of the room.

Floor standing
990
199

Specifications
Model name ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.5 5.6 7.1
Capacity kW
Heating 4.0 5.0 6.3 8.0
Flexible installation Input power W 30 42 74 99
High 660 780 1,000 1,000
Example for floor installation Example for ceiling installation
Airflow rate Med m3/h 570 640 720 820
Floor console Under ceiling Low 490 550 580 680
High 36 40 46 47
Sound pressure dB
Med 32 36 39 42
level (A)
Low 28 34 35 37
Dimensions (H × W × D) mm 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655
Weight kg 25 26 26 27
Connection Liquid (Flare) 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.D.) 25 / 32
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Double auto swing High power DC fan motor


A combination of up/down and right/left directional swing • High power
allows three-dimensional air direction control. • Wide rotation range
• High efficiency Dimensions (Unit: mm)
RIGHT and LEFT SWING
3
2 4
1 5

5 steps selectable

UP and DOWN SWING 1


2 1
2

3 2
1
4

1 Refrigerant piping flare connection (Liquid)


2 Refrigerant piping flare connection (Gas)
4 steps selectable
3 Drain piping connection 3 3

86 87
AIRSTAGE Indoor units
TM

Ceiling Fresh air intake High lift drain pump


Optional drain pump unit allows flexible installation design.

Fresh Max.

Models air
500mm
ABHA30GATH Indoor Outdoor
ABHA36GATH
ABHA45GATH
ABHA54GATH
Slim & Compact design

Hight Optional parts


240mm Drain Pump Unit : UTR-DPB24T
Flange : UTD-RF204

Specifications
Model name ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 9.0 11.2 12.5 14.0
Capacity kW
Heating 10.0 12.5 14.0 16.0
Installation Input power W 66 85 131 180
High 1,630 1,690 2,010 2,270
Open Concealed Wall mounted Airflow rate Med m3/h 1,370 1,400 1,600 1,780
(Field Supplied)
Low 1,140 1,170 1,230 1,280
High 42 45 48 51
Sound pressure dB
Med 38 38 42 45
level (A)
Low 33 34 35 36
Dimensions (H × W × D) mm 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700
Weight kg 46 48 48 48
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 19.05 19.05 19.05
Drain hose diameter (I.D./O.D.) 25 / 32
General installation pattern Installation pattern where part Installation which fixes the indoor unit to the
Note : Specifications are based on the following conditions.
which suspends the indoor of the indoor unit is embedded wall by the use of wall brackets (Field supplied). Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.
unit from the ceiling. into the ceiling. This type of installation can be used Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
when the ceiling space is insufficient.

Double auto swing and wide airflow Long airflow


Auto airflow direction and auto swing Long Airflow ensures
comfort to every corner Dimensions (Unit: mm)
of a large room.
Right and left

low
air-f
nce
gd ista
Lon

5 steps selectable
High power DC fan motor
• High power • Wide rotation range • High efficiency
Up and down

3
1 Refrigerant piping flare connection (Liquid)
4 2 Refrigerant piping flare connection (Gas) 3
4 steps selectable 3 Drain piping connection 2 1 3

88 89
AIRSTAGE Indoor units TM

Compact Wall Mounted Compact size Auto swing louvre


Powerful output even compact design Width The Auto Swing Louvre function

Models (EEV internal model) Though the indoor unit is compact, it features 790mm ensures that the air direction
corresponds to the mode selected.
a large, high pressure cross fan (90mm
ASHA07GACH diameter) in a centre mounted configuration
ASHA09GACH and a Lambda type heat exchanger to
ASHA12GACH provide plenty of power. 1

ASHA14GACH
2

Sw
3

ing
4
Step
Swing

Filter features
High quality air conditioning by incorporation of high performance
filter.
Deodorizing effect (Odor reduction rate) 790mm
Easy maintenance
Ammonia Trimethylamine
(ppm) (ppm) Easy maintenance
Ion Deodorization Filter 160 160 has been realized as the
With no filter
120
With no filter
120 New style high power DC fan motor front panel can removed
80 80 New filter for easy access.
The filter deodorizes by powerfully decomposing absorbed odors • High power Open panel
New filter
using the oxidizing and reducing effects of ions generated by the 40 40
• Wide rotation range
ultra-fine-particle ceramic. 0
0 30 60 120 (min)
0
0 30 60 120 (min)
• High efficiency
• Compact size
Hydrogen sulfate
(ppm)
Apple-catechin Filter 160
With no filter
120
Apple-catechin filter uses static electricity to clean fine particles 80 New filter Testing organization :
and dust in the air. 40 Environmental Sanitary Inspection Center
Symmetrical design
0 Test method :
0 30 60 120 (min) Symmetrical, clean design that suits all interiors.
Deodorization Test

Dimensions (Unit: mm)

Models: ASHA07 / ASHA09 / ASHA12 / ASHA14


Specifications
Model name ASHA07GACH ASHA09GACH ASHA12GACH ASHA14GACH
Power source Single - phase, ~230V, 50Hz 790
Cooling 2.2 2.8 3.6 4.5
Capacity kW
Heating 2.8 3.2 4.1 5.0
Input power W 17 18 22 34
High 490 500 560 670
Airflow rate Med m3/h 450 450 480 490

275
Low 370/420*1 370/420*1 420 420
High 35 36 39 44
Sound pressure dB
Med 33 33 35 37
level (A)
Low 27/31*1 27/31*1 31 32
Dimensions (H × W × D) mm 275 x 790 x 215
Weight kg 9
470
Connection Liquid (Flare) 6.35 3
pipe diameter 530
Gas (Flare) mm 12.70
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7 660
EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts:
1 2

65
416 19
222 32

UPWARD

Install the unit where it will not be tilted

Vertical installation
Install the unit as confirmed direction.
wire
1 Refrigerant pipe flare connection (Liquid)
UPWARD wire

121
by more than 5°
Install the unit as confiremed direction .

97
Install the unit where it will not be tilted

2 Refrigerant pipe flare connection (Gas)


by more than 5°
Horizontal installation

65
OUTDOOR UNIT INDOOR UNIT
SIDE SIDE

3 Drain piping connection

90 91
AIRSTAGE Indoor units TM

Wall Mounted Double auto swing


A combination of up/down and right/left directional swing allows
three-dimensional air direction control.
Air conditioner filter features

Models
5 steps selectable
ASHA18GACH
ASHA24GACH
ASHA30GACH

4 steps selectable

1 High quality air conditioning by incorporation of high performance filter.


More comfort airflow by adopting power diffuser 2
“Vertical airflow” “Horizontal airflow” does not blow cool air

Sw
provides powerful floor level heating directly at the occupants in the room
3 Step Ion Deodorization Filter

in g
Swing
4

5 5 The filter deodorizes by powerfully decomposing absorbed odors using the


(24/30) (24/30)
oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.

2.5 2.5

Compact & Slim design Apple-catechin Filter

03 69 12(m) 03 69 12(m) By using DC fan motor, compact design is realized.


Apple-catechin filter uses static electricity to clean
Power diffuser fine particles and dust in the air.

33 32 31 30 29 15 16 17 18
o
46

Easy maintenance
Power diffuser (full open)

DC fan motor
998mm Simplification of drain pan cleaning improves
maintenance-ability.

Specifications Dimensions (Unit: mm)

Model name ASHA18GACH ASHA24GACH ASHA30GACH Models: ASHA18 / ASHA24 / ASHA30


Power source 230V ~, 50Hz
998
Capacity Cooling 5.6 7.1 8.0
kW
Heating 6.3 8.0 9.0
Input power W 32 60 91
High 840 (233) 1,100 (305) 1,240 (343)
m 3/h
Airflow rate Med (I/s) 770 (213) 910 (252) 980 (271)
320
Low 690 (191) 730 (202) 770 (213)
High 41 48 52
Sound pressure level Med dB(A) 39 43 45
Low 35 35 35
Dimensions (H x W x D) mm 320 x 998 x 228 520
Weight kg 15 590
Connection Liquid (Flare) ø9.52 228
pipe diameter 721
Gas (Flare) mm ø15.88
Drain ø12 (I.D.) ; ø16 (O.D.)

1 Refrigerant piping flare connection (Liquid)


2 Refrigerant piping flare connection (Gas)
520 3 Drain hose connection

92 93
AIRSTAGE Indoor units TM

Wall Mounted
Models
ASHA004GTAH
ASHA007GTAH
ASHA009GTAH

Specifications
Model name ASHA004GTAH ASHA007GTAH ASHA009GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 1.1 2.2 2.8
Capacity kW
Heating 1.3 2.8 3.2
High efficient compact design Input power W 13 19 34
High 430 550 720
Ø5mm high density heat exchanger is mounted for the first time in the industry. Med-H 420 460 570
Med 390 420 500
Airflow rate m3/h
Med-L 380 390 410
Low 360 360 360
Quiet 330 330 330
High 31 35 43
High density heat exchanger Med-H 30 32 38
Sound pressure Med dB 28 30 34
Making the tube thin: level Med-L (A) 26 27 29

7 mm 5 mm Dimensions (H × W × D)
Low
Quiet
mm
24
22
262×820×206
24
22
262×820×206
24
22
262×820×206
Increase of heat exchanger volume
Weight kg 7.5 7.5 7.5
by high density and adopting sub
Connection Liquid (Flare) 6.35 6.35 6.35
heat exchanger pipe diameter Gas (Flare) mm 9.52 9.52 9.52
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - - -
Note : Specifications are based on the following conditions. When ASH*004GTAH, ASH*007GTAH, ASH*009GTAH are connected to the outdoor unit
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. other than J-IIIL, gas pipe diameter should be Ø12.70.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].

Dimensions (Unit: mm)

6 Fan Speed Control Easy installation 820 206


Fan speed Low noise
Multistep airflow control is possible Communication wiring
to suit the environment. Quiet 22 dB(A) can be installed easily by
only opening the front
panel and wire cover.
6-Step Speed
High

Med-H 262

Med

Med-L

Low

Quiet
Optimized design matches to a small room
* Compatible Remote Controller is as follows:
Efficient operation and refrigerant saving are realized by optimum
UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 heat exchanger design suited for small rooms.

94 95
AIRSTAGE Indoor units TM

Wall Mounted
Models
ASHA012GCAH
ASHA014GCAH

Specifications
Model name ASHA012GCAH ASHA014GCAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 3.6 4.0
Capacity kW
Heating 4.0 4.5
High efficient compact design Human sensor increases Input power W 25 36

High efficient compact design is realized by mounting a high density more energy saving High
Med-H
690
610
800
740
and large heat exchanger. Med 560 680
Energy saving operation starts automatically by Airflow rate m3/h
Compact body makes it possible to install inconspicuously even in a Med-L 530 610
detecting the motion of a person. 2 modes of save
meeting or office room and comfortable air conditioning is provided. Low 470 550
operation mode and stop mode can be selected. Human sensor
Quiet 330 330
High 40 44
People go out. People come back. Med-H 37 42
Sound pressure Med dB 35 40
level Med-L (A) 33 37
Low 30 34
Quiet 24 24
Dimensions (H × W × D) mm 268 × 840 × 203 268 × 840 × 203
Weight kg 8.5 8.5
Connection Liquid (Flare) 6.35 6.35
pipe diameter Gas (Flare) mm 12.70 12.70
Drain hose diameter (I.D./O.D.) 13.8 / 15.8 to 16.7
EV Kit (option) - -
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
High density heat exchanger
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Even temperature 6 Fan Speed Control
7 mm 5 mm
Making the Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
tube thin: Fan speed Low noise
Multistep airflow control
Increase of heat exchanger volume by high
density and adopting sub heat exchanger
Improved
heat exchanger is possible to suit the Quiet 24 dB(A) Dimensions (Unit: mm)
effectiveness
environment.
6-Step Speed
High

More comfort airflow Med-H 840 203

Comfortable air conditioning is provided by mounting Med


our unique power diffuser. Med-L

Heating Low
Vertical airflow provides Quiet
powerful floor level heating

268
* Compatible Remote Controller is as follows:
Power diffuser UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1

Cooling
Horizontal airflow does not blow
cool air directly at the occupants
Optional parts
in the room. Wired Remote Controller: UTY-RNRGZ2, UTY-RLRG
Wireless Remote Controller: UTY-LNHG
Power diffuser
Simple Remote Controller: UTY-RSRG, UTY-RHRG

96 97
AIRSTAGE Indoor units
TM

Wall Mounted
Models Models
ASHA18GBCH ASHA030GTAH
ASHA24GBCH ASHA034GTAH

ASHA18 ASHA24

ASHA030 ASHA034
Specifications
Model name ASHA18GBCH ASHA24GBCH ASHA030GTAH ASHA034GTAH
Feature Power source Single - phase, ~230V, 50Hz
Cooling 5.6 7.1 9.0 10.0
Capacity kW
Heating 6.3 8.0 10.0 11.2
Powerful & Comfort airflow Input power W 32 60 74 103
High 840 1,100 1,440 1,620 / 1,520
Powerful Airflow Power diffuser
Med-H - - 1,200 1,300
(ASHA030GTAH) (ASHA18/24GBCH) Med 770 910 1,050 1,120
Airflow rate m3/h
Med-L - - 940 980
Vertical airflow Horizontal airflow Low 690 730 890 890
(24) (24) Quiet - - 700 700
High 41 48 53 55 / 54
Med-H - - 49 51
Airflow Sound pressure Med dB 39 43 45 47

20% up! level Med-L (A) - - 42 43

33 32 31 30 29(˚C) 15 16 17 18(˚C) Low 35 35 39 39


Quiet - - 33 33
Dimensions (H × W × D) mm 320 × 998 × 238 320 × 998 × 238 340 x 1,150 x 280 340 x 1,150 x 280
Weight kg 15 15 18 18
Connection Liquid (Flare) 6.35 9.52 9.52 9.52
Human sensor (ASHA030/034GTAH only) pipe diameter Gas (Flare) mm 12.70 15.88 15.88 15.88
Drain hose diameter (I.D./O.D.) 12 / 16 13.8 / 15.8 to 16.7
A human sensor senses the movement of humans to reduce operation Note : Specifications are based on the following conditions. When ASHA18GBCH is connected to the outdoor unit other than J-IIIL,
when one is in the room. the wasteful consumption of energy is reduced Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB. pipe diameter should be Ø9.52/Ø15.88 (Liq/Gas).
automatically to keep down electricity bills. Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
(Available to wired remote controller as UTY-RNRGZ2) Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Human sensor

Dimensions (Unit: mm)

Models: ASHA18 / ASHA24 Models: ASHA030 / ASHA034

998 238 1150 280

Quiet operation & 6 Fan speed control


6-Step Speed

320

340
Drastic low noise is realized by new
airflow structure. In addition, multistep -2 dB(A) High
25

quiet operation is available by 6-step 35dB(A) 520


ø32
ø12
ø16

sound level settings. Med-H 590


33dB(A)
721
Med
520
Med-L

Low

Quiet
1 Refrigerant piping flare connection (Liquid)
Current model New model 2 Refrigerant piping flare connection (Gas)
* Compatible Remote Controller is as follows:
(030/034class) UTY-RNRGZ2 / UTY-RLRG / UTY-RSRG / UTY-RHRG / UTY-DCGG / UTY-DTGGZ1 / UTY-ALGXZ1 / UTY-APGXZ1 3 Drain piping connection

98 99
User friendly control system
provides individual control to centralized control

The AIRSTAGE control system can perform air conditioning control of individual

room, centralized control by floor or by building, or centralized energy saving air

conditioning control for large buildings.

A variety of air conditioning management schemes are available to match the

application, such as linking with the building control system, linking with a single split

models, and using various interfaces.

AIRSTAGE
TM
CONTROL SYSTEM

CONTROL SYSTEMS
CONTROL SYSTEM OVERVIEW
INDIVIDUAL CONTROLLER
CENTRALIZED CONTROLLER
CONVERTOR / ADAPTOR

100 101
AIRSTAGE Control Systems TM

BEST CONTROL SOLUTION FOR EACH PROPERTY


Fujitsu General provides the best control solutions suitable for the various properties.

SHOP OFFICE
Individual Individual
Type Control
Centralized Control Integrating Control (Interface) Type Control
Centralized Control Integrating Control (Interface)

WHITE-USB-KEY
(Software Protection Key)

Network Network External


Wired Remote Group Remote Central Remote Touch Panel System MODBUS® KNX® Wired Remote Simple Remote Wireless Remote Group Remote Central Remote Touch Panel System BACnet ® MODBUS® KNX®
Convertor Convertor Switch
Controller Controller Controller Controller Controller Convertor Convertor Controller Controller Controller Controller Controller Controller Controller Gateway Convertor Convertor
for LONWORKS® for LONWORKS® Controller

UTY-RNRGZ2, UTY-APGXZ1, UTY-VMSX, UTY-VKGX, UTY-RNRGZ2, UTY-RSRG, UTY-APGXZ1, UTY-ABGXZ1, UTY-VMSX UTY-VKGX
UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-VLGX UTY-LNHG UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-VLGX UTY-TERX
UTY-RLRG UTY-ALGXZ1 UTY-VMGX UTY-VKSX UTY-RLRG UTY-RHRG UTY-ALGXZ1 UTY-VBGX UTY-VMGX UTY-VKSX

Automatic control of A/C


Local control for office staff
(Schedule timer, Weekly timer etc.)

Limited control for staff Automatic control of A/C


(RC Prohibition, Room temp (Schedule timer, Weekly
set point limitation etc.) timer etc.)

Centralized A/C control for


Group Control
management

Advanced Energy Saving Limited control for office staff


(Peak cut, Indoor unit rotation (RC Prohibition, Room temp
operation etc.) set point limitation etc.)

Advanced Energy Saving


Remote Management (Peak cut, Indoor unit rotation
operation etc.)

Manage multiple sites Remote Management

Monitor energy consumption Energy Charge Apportionment

Control third party products Monitor energy consumption

Integrate FGL A/C into BMS Control third party products

Integrate FGL A/C into BMS


HOTEL
Individual
Type Control
Centralized Control Integrating Control (Interface) Interlock with door contact

WHITE-USB-KEY

Interlock with human sensor


(Software Protection Key)

for meeting room


Network External
Wired Remote Simple Remote Wireless Remote Group Remote Central Remote Touch Panel System BACnet ® MODBUS® KNX®
Convertor Switch
Controller Controller Controller Controller Controller Controller Controller Gateway Convertor Convertor
for LONWORKS® Controller

UTY-RNRGZ2, UTY-RSRG, UTY-APGXZ1, UTY-ABGXZ1, UTY-VMSX UTY-VKGX


UTY-LNHG UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-VLGX UTY-TERX
UTY-RLRG UTY-RHRG UTY-ALGXZ1 UTY-VBGX UTY-VMGX UTY-VKSX

Local control for hotel guest

Centralized A/C control for


common space

Limited control for hotel guests

Remote Management

Advanced Energy Saving


(Peak cut, Indoor unit rotation
operation etc.)

Monitor energy consumption

Control third party products

Integrate FGL A/C into BMS

Interlock with window contact

Interlock with key-card

102 103
AIRSTAGE Control Systems
TM

CONTROL SYSTEM OVERVIEW


For Light Commercial For Commercial
• Small VRF • Large VRF

User’s needs are supported by offering a variety of controls, such as individual control,
central control and building management control options.

Air Conditioning Air Conditioning Convertor / Adaptor


Individual Control Centralized Control For external device
Remote/
Monitoring side
BACnet® Gateway
Wired Remote Controller Internet or
(Touch panel)
UTY-ABGXZ1 Software
Public
Telephone
UTY-RNRGZ2 Line
USB Adaptor *1

BACnet® Gateway
(Field supplied)
Max. controllable UTY-VBGX Hardware
Wired Remote Controller
UTY-RNRG System Controller Software 1600
Indoor units
*
BMS/BAS *2
UTY-APGXZ1 / UTY-ALGXZ1 (Lite edition) Network Convertor
(BMS/LONWORKS®)
*: Lite edition is max. controllable 400 indoor units
Remote/ UTY-VLGX
Monitoring side
Simple Remote Controller
UTY-RSRG Internet or MODBUS® Convertor
UTY-RHRG Public
Without operation mode Telephone UTY-VMGX
Line
BMS, Home automation system
Max. controllable MODBUS® Convertor For indoor unit
Wireless
Remote Controller Touch Panel Controller 400
Indoor units
UTY-VMSX
or
UTY-DTGGZ1
UTY-LNHG
MODBUS® Interface
FJ-RC-MBS-1 *1. USB Adaptor: Echelon® U10 USB Network Interface
Central Remote *2. BMS/BAS: Building Management System/Building Automation System
Max. controllable
Controller
IR Receiver Unit
UTB-YWC For Duct type
UTY-DCGG 100
Indoor units KNX® Convertor For VRF
UTY-LRHGB1 For Cassette type UTY-VKGX
For Duct For Cassette

Group Remote KNX® Convertor For indoor unit


UTY-VKSX
Convertor / Adaptor
Controller
UTY-CGGG
Max. controllable
KNX® Interface For system expansion
Network Convertor
8
Remote Controller
FJ-RC-KNX-1i
UTY-VGGXZ1 Groups
Network Convertor
(DC power supply) Single split
Wireless LAN Interface
UTY-VTGX
FJ-RC-WIFI-1 / UTY-TFSXZ1

External Switch Controller Network Convertor


UTY-TERX (AC power supply) Single split
UTY-VTGXV

Card-key Network Convertor Signal Amplifier


Internet device
(Field supplied) UTY-VGGXZ1 UTY-VSGXZ1

104 105
AIRSTAGE Control Systems TM

COMPARISON TABLE OF CONTROLLERS

Type
Wired Remote Controller System Controller Lite System Controller
Wired Remote Controller Simple Remote Controller Simple Remote Controller *1 Wireless Remote Controller Group Remote Controller Central Remote Controller Touch Panel Controller
(Touch panel)
Model name UTY-RNRGZ2 UTY-RLRG UTY-RSRG UTY-RHRG UTY-LNHG UTY-CGGG UTY-DCGG UTY-DTGGZ1 UTY-ALGXZ1 UTY-APGXZ1
Max. controllable remote controller groups 1 1 1 1 1 8 100 400 400 1600
Max. controllable indoor units 16 16 16 16 16 128 100 400 400 1600
Max. controllable groups — — — — — — 16 400 400 1600
On / Off          
Operation mode setting    —      
Fan speed setting          
Room temp. setting          
Air conditioning control function

Room temp. set point limitation     — —    


Test operation      —   — —
Up/down air direction flap setting      —    
Right/left air direction flap setting   — —  —    
Individual louver control  — — — — — —  — —
Group setting — — — — — —    
RC prohibition — — — — — —    
Anti freeze setting  — — — — —    
Set temp. auto return   — — — — —  — —
Economy mode setting   — —  —    
Human sensor control  — — — — — —   
Custom Auto setting  — — — — — —  — —
Error     —     
Defrosting     — —    
Current time   — —      
Day of week   — — —  —   
R.C. prohibition     —     
Display

Cooling/heating priority     —     
Address display     —     
Room temp  —   — — —  — —
Multi language  — — — — —    
Summer time  — — — — —    
Name registration  — — — — —    
Backlight  —   — —   — —
2D floor layout / 3D building display — — — — — — — — — 
Period Week Week — — — Week Week Year Year Year
Schedule
timer On/off, Temp,
8 4 — — — 4 20 20 144 144
Mode, Times per day
Timer

On/off timer   — —  — — — — —
Sleep timer — — — —  — — — — —
Program timer — — — —  — — — — —
Auto off timer   — — — — —  — —
Day off   — — — —    
Min. unit of timer setting (Minutes) 10 • 30 30 — — 5 10 10 10 10 10
Status monitoring system — — — — — —    
Electricity charge apportionment — — — — — — —   
Error history   — — —     
Emergency stop — — — — — — *2 *2 — —
Control

Remote management — — — — — — —   
Energy saving management — — — — — — — —  
E-mail notification for malfunction — — — — — — —   

Key lock       
— — —
Child lock Child lock Child lock Password setting Password setting Password setting Password setting

Low noise mode — — — — — — —  — —

*1 “Operation mode” setting is not available for this model. *2 This function is available only through external input control. : Supported : Optional function — : Not supported yet

106 107
AIRSTAGE Control Systems Individual Controller
TM

Wired Remote Controller (Touch Panel) Various energy saving control Simplified installation
Max. controllable

16 Custom Auto Uses non-polar 2-wire type


indoor units

• Maintains 2 separate set points for heating and cooling. • The faulty wiring can be prevented by using non-polar 2-wire.
UTY-RNRGZ2 • Automatically changes mode between heating and cooling.
* This function is not available for some models.
Easy operation by high-definition large STN-LCD touch panel screen I.U. Y1Y2 Y3 I.U. Y1Y2 Y3
Cooling set temp. 27˚C, Heating set temp. 26˚C
• Easy finger touch operation with LCD panel
• Built-in weekly/Daily timer (ON/OFF, Temp., Mode)
• Backlight enables easy operation in a darkened room
• Room temperature display non-polar
Auto 2-wire
• Control up to 16 indoor units
Operation Start
Changeover
• Corresponds to 12 different languages
Change over
(English, Chinese, French, German, Spanish, Russian, Polish, Italian, Greek, Portuguese, Turkish and Dutch) OK OK
Cooling Set Point
• 2-wire type
Heating Set Point
Change over

Functions Room temperature Y1 Y2 Y1 Y2


Auto OFF timer

High performance and compact size Various convenient functions • The indoor unit automatically is turned off when it reaches to the
preset operating time frame.
• In addition to the individual control, various energy saving controls Displays setting status and Limitations • The time frame of the “Auto off timer” can be flexibly scheduled.
can be realized using one remote controller only. • Can be set off time 30 to 240 minutes
• The remote controller settings can be
easily checked
Individual Thermo Weekly Auto off
control sensor timer timer
Auto Address Setting/Setting Position Notification
Set interval time (17:00 to 24:00) • Reduce errors and install time compared with the current
specification Rotary SW
ON OFF ON Auto OFF ON Auto OFF • When will be set remote controller groups, can also be set
automatically new Wired remote controller address
Accurate and comfortable control 1 hour 1 hour • After auto address setting of new wired remote controller groups,
what number can also confirm addresses
• Indoor temperature can be detected accurately by the inclusion of a Normal Time Over Time Address → 04 03 02 01
thermo sensor in the body of the wired controller.
8 17 24
Ex.) At interval time hour (17:00 to 24:00) to prevent forgetting to turn off
Summer Time display Set off time : 1 hour The appropriate indoor unit
performs the air blow and
• This function can be set easily from 2 schedules Weekly Timer LED lamps blink.
Menu screen
• 2 schedules such as for the summer and winter can be set.
• 8 setting changeable per day of week (Setting items: On/Off, 05
Temperature, Mode, Time)

Ex)
Easy Maintenance
Error History Display
• The errors that occur in the indoor unit or
Child lock
remote controller are saved as a history.
• Lock / unlock method: Push the ON/ • A maximum of 32 error incidents can be
OFF button and the screen (4 seconds) saved.
Set Temperature Auto Return
• The setting temperature automatically returns to the previous
setting temperature.
• The time range in which the set temperature can be changed is 10 to
120 minutes.
Room temperature sensor Room temperature
display Set Temperature Upper and Lower Limit Setting
• The set temperature range can be set for each operation mode.
Name Registration
(Cooling / Heating / Auto).
Backlight • Remote controller names can be Initial Setting Page 1/ 3

registered in the remote controller


Language Setting Date Setting

• Backlight enable easy operation in a Temp. Unit R.C.Group

screen.This makes it easy to identify Setting Name Setting

darkened room. Back


Next

the indoor unit you want to control in


Page

• For the lighting time of Backlight, 30 Specifications


the room.
or 60 seconds can be set.
Model name UTY-RNRGZ2
• Backlight activates while the buttons
Power Supply DC 12V
are operated and goes off 30 or 60
Dimensions (H x W x D) mm 120 × 120 × 20.4
seconds after the operation stops.
Weight g 220
DC12V is supplied by indoor unit.

108 109
AIRSTAGE Control Systems Individual Controller
TM

Wired Remote Controller Simple Remote Controller


Max. controllable Max. controllable

16 16
indoor units indoor units

UTY-RLRG UTY-RSRG
UTY-RHRG (Without Operation mode)
• Various timer setup (ON / OFF / WEEKLY) are possible.
• The room temperature can be controlled by detecting the temperature accurately with Built-in thermo sensor.
• When a failure occurs, the error code is displayed. Compact remote controller provides access to basic functions
• Error history. (Last 16 error codes can be accessed.)
• Up to 16 indoor units can be controlled with one remote controller.
• 2-wire type
• Suitable for hotels or offices as it is easily operated with no complex functions.
• Stylish design: Simple design to match the stylish interior.
• Large LCD screen & simple operation buttons
• Backlight: White colored backlight on monitor enable easy operation in dark.
• 2-wire type
UTY-RSRG UTY-RHRG
Without Operation mode

Functions Functions

High performance and compact size High visibility and Corresponding to various applications
In addition to the individual control, weekly timer, and various energy easy operation • Vertical louver control:
saving controls can be realized using only one remote controller. • “Mode”, “Set Temp”, and “Fan” are Vertical air flow direction can be adjusted for Duct types with
displayed at large size on the top screen. auto louver and Cassette types, which are installed in hotels and
• Each function to be set is indicated by conference rooms, can be adjusted.
Individual Thermo Weekly Auto OFF an icon. Sophisticated control buttons
control sensor timer timer Simple operation with easy
• Control guide is displayed and operation
4-way navigation pad
is simple and straightforward.
Set contents can be displayed
clearer with large LCD.

Auto-off timer Set temperature auto return


• Room temperature set point limitation:
During Cooling During Heating
• The indoor unit automatically turns off after a set time has passed. • The setting temperature automatically returns to the previously set
temperature. The Simple Remote Controller can manage to energy saving 30°C 30°C
Operation • The time range in which the set temperature can be changed is 30 to operation in small buildings without the central control unit. 25°C
status 25°C
Auto OFF Auto OFF 240 minutes.
ON
Cooling operation Heating operation
Setting temp. Setting temp.
18°C 16°C
Set temperature change Auto return Set temperature change Auto return
OFF 24°C 25°C
22°C 23°C
Auto-off timer can be
set from 30 to 240 Settable time range Settable time range
minutes 30 to 240 minutes 30 to 240 minutes • Built in room temperature sensor:
Time Time The Simple Remote Controller detects actual room temperature and
controls room climate accuracy.

Weekly timer function Set temperature upper and lower limit setting
• Not only time setting On / Off, but also setting of the operation • The set temperature range can be set for each operation mode.
Room temperature
mode and set temperature can be set by Weekly timer function. (Cooling / Heating / Auto)
sensor
ON OFF ON OFF During Cooling During Heating
24°C 30°C 30°C

25°C
Working hour Working hour 25°C

8:00 12:00 13:00 17:00 18°C 16°C


Original temp. Lower limit Original temp. Upper limit
4 types (ON, OFF, ON, OFF) can be set on every day of the week in a week. setting range setting setting range setting

Specifications Specifications
Model name UTY-RLRG Model name UTY-RSRG UTY-RHRG
Power Supply DC 12V Power Supply DC 12V
Dimensions (H x W x D) mm 120 × 120 × 17 Dimensions (H x W x D) mm 120 × 75 × 19.4
Weight g 170 Weight g 120
DC12V is supplied by indoor unit. DC12V is supplied by indoor unit.

110 111
AIRSTAGE Control Systems Individual Controller
TM

Wireless Remote Controller IR Receiver Unit


Max. controllable Selectable

16 4
indoor units daily timers

UTY-LNHG UTB-YWC

Simple and sophisticated operations Necessary to control for all Duct types* by Wireless Remote Controller
with a choice of 4 daily timers *Only Large Airflow Duct can not be connected to IR Receiver Unit.

• A single controller controls up to 16 indoor units. • Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.

Functions

Wiring connection

Functions

Built-in daily timer Easy installation and operation Wireless


Remote Controller
Select from 4 different timer programs : On / Off / Program / Sleep Code selector switch
Duct Type Indoor Unit
Program timer : The program timer operates the ON and OFF timer prevents indoor unit
mix-up. (Up to 4 IR Receiver Unit
once within a 24 hour period.
codes can be set.)
Sleep timer : The sleep timer function automatically corrects the
set temperature according to the time setting to prevent excessive
cooling or heating during sleep hours. Specifications
Model name UTB-YWC
Wide and precise Power Supply DC 5V
Cooling operation/dry operation Dimensions (H x W x D) mm 145 × 90 × 30
When the sleep timer is set, the set temperature automatically rises Weight g 150
1˚C every hour. The set temperature can rise up to a maximum of 2˚C.

T imer setting

60min.
IR Receiver Unit
Address setting UTY-LRHGB1
2˚C
1˚C During installation work, address setting can be performed using the
Wireless Remote Controller, thus eliminating manual switch setting. Cassette type indoor unit can be controlled
with Wireless Remote Controller
Heating operation
Transmission line
When the sleep timer is set, the set temperature automatically drops
1˚C every 30 minutes. The set temperature can drop to a max. of 4˚C.
Indoor unit
Outdoor unit

1˚C
2˚C
Functions
3˚C Wireless
4˚C Remote Controller

30min.

60min.

90min.
T imer setting Wireless
Remote Controller

Specifications Specifications
Model name UTY-LNHG Model name UTY-LRHGB1
Power Supply 1.5V (R03 / LR03 / AAA) × 2 Power Supply DC 5V
Dimensions (H x W x D) mm 170 × 56 × 19 Dimensions (H x W x D) mm 193.9 × 193.9 × 31.2
Weight g 85 Weight g 140

112 113
AIRSTAGE Control Systems Centralized Controller
TM

Group Remote Controller Central Remote Controller


Max. controllable Max. controllable Max. controllable Max. controllable

8 64 100 16
remote controller group R.C. in a VRF indoor units groups
groups network system

UTY-CGGG UTY-DCGG

Group control of indoor units with simple operation Central control of small- and medium-sized buildings and tenants. The operation
• Up to 8 remote controller groups can be controlled by one Group Remote Controller.
status of all connected indoor units can be viewed at a glance on a large LCD monitor
• Up to 64 Group Remote Controllers can be connected in one VRF network system. to simplify individual control to batched control.
• Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers
to a VRF network system. • Individual control and monitor of 100 indoor units
(Network Convertor allows up to 4 Group Remote Controllers) • 5 inch TFT color screen
• User friendly view and easy operation
• External input / output contact
• Detachable power supply unit
• Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)

Functions Functions

Control up to 8 remote controller groups System overview Group : Hallway

Group : 3F
Single Group Remote Controller controls and monitors up to 8 remote controller groups. • It allows multiple indoor
Group : Division A Group : Division B Group : Division C
units grouping (Max.16
Refrigerant Refrigerant groups controlled)
system 1 system 2 • Interlock with external
device
Hotel Group : 2F

Group : Tenant A Group : Tenant B Group : Tenant C

Office & Lounge


Emergency stop
Guest room function

Restaurant

Lounge
Functions
Office room
• Diverse control of indoor units • Remote controller prohibition • Weekly timer • Error history • Automatic clock adjustment
Network (All, On / Off, Mode, Temp, Timer, Filter)
Lobby Convertor
Group Remote Controller 1:
To control office room, lounge,
Restaurant restaurant and lobby
(8 remote controller groups)

Group Remote Controller 2:


1 2 To control guest room
Group Remote Lobby and launge
Controller (7 remote controller groups)

Easy Installation
• The control panel and power supply unit can be installed separately. • Automatic or manual indoor unit registration
• For flexibility in installation, the Control panel can be built into the
High performance and compact size Built-in weekly timers wall or fix on the wall. Indoor unit registration

ON / OFF, Operating mode, Room temperature and Fan speed setting The weekly timer is provided as a standard function. Setting pattern 1 Setting pattern 2
can be controlled / monitored centrally or individually. 1. The timer can be set up for up to 4 times per day. Ceiling
Indoor unit registration
start
(On / Off, operating mode, set temperature) Power supply unit
Power supply unit

Central ON/OFF Weekly 2. Allows separate settings for each day of the week.
control control timer Control panel Wall Control panel

Control panel + Power supply unit Wall Indoor unit registration


finish

Specifications
Model name UTY-DCGG
Control Panel Power Supply Unit
Specifications
Power Supply DC 5 V 100-240V, 50-60Hz, Single phase
Model name UTY-CGGG Dimensions (H x W x D) mm 120 x 162 x 25.7 99 x 135 x 39.2
Power Supply DC 12V Weight g 308 355
Dimensions (H x W x D) mm 120 × 120 × 18 <PACKING LIST>
Weight g 200 Packing List Control Panel / Power Supply Unit / Connecting cable, etc.
DC12V is supplied by indoor unit.

114 115
AIRSTAGE Control Systems Centralized Controller
TM

Touch Panel Controller Control & monitoring from anywhere


Max. controllable Max. controllable Max. controllable

400 100 400 • Control and monitor Fujitsu’s air conditioner via LAN or Internet.
indoor units outdoor units groups
• Allow user or tenant to manage only assigned equipment by their PC or tablet from anywhere.
UTY-DTGGZ1 • Error contents are notified automatically by E-mail at error occurrence to handle the trouble promptly.

• Large-sized 7.5-inch TFT color


• LCD Easy finger touch operation
• Stylish shape and design to suit all application Operation status monitoring
• Up to 400 indoor units can be controlled
• Selectable 2 display types (Icon / List) in monitoring mode Error notification by E-mail
Tablet
• Supports 7 different-languages ,English, Chinese, French, German, Spanish, Russian, Polish.
• Mounted with LAN interface for remote control & operation, external input / output with
emergency stop and batch ON / OFF
LAN
or
Internet

Functions PC

Operation mode setting VRF network system


Control & monitoring from anywhere
• Control and monitor Fujitsu’s air conditioner via LAN or Not only operations but also detail
Internet. settings such as schedule or group
• Allow user or tenant to manage only assigned settings can be operated from
equipment by their PC or tablet from anywhere. remote locations.
• Error contents are notified automatically by E-mail at
error occurrence to handle the trouble promptly.

Individual control Flexible grouping Schedule control Indoor units


operation monitoring

Smart Phone Tablet


Model name Browser Model name Browser
Nexus 6P (Android 7.1.1) Google Chrome 5.5 ipad Pro 9.7inch (iOS 10.2.1) Safari 10
iphone7 (iOS 10.1) Safari 10

Flexible access permission for Point each level user.


Administrator can register multiple user to permit which indoor Monitoring from
unit(s) and which function can access. ON/OFF
prohibition web site
Easy maintenance Easy installation Operation ON
• Flat touch screen is easily cleaned • Touch Panel Controller is easily mounted to the wall.
• Non-glare coating on touch panel controller • Flat back surface allows to be installed wherever it Administrator
minimizes fingerprint marking is needed.
• Easy-to-remove front cover • No additional component is required for installation
Operation ON

Staff / Employee

Up to 400 indoor units can be controlled

Group A
Additional languages function
Group B
Corresponds to 7 different languages, English, Chinese, French, Monitoring from web site
German, Spanish, Russian, Polish as standard.
Additional language can be integrated on remote device by
creating language database.
It allows multiple indoor unit grouping
Additional language is displayed on only the remote device, and
Write
Touch Panel Controller cannot be added other languages.

Emergency stop control Language data


Air conditioner can be turned 7 Languages
off through the external input control Emergency stop function
7 Languages + NEW Other languages

116 117
AIRSTAGE Control Systems Centralized Controller
TM

Functions FUNCTIONS SUMMARY

Electricity charge apportionment UTY-PTGXA

• Electricity charge apportionment can


Electricity Electric power
be performed easily for the power meter company UTY-DTGGZ1 Monitoring side UTY-DTGGZ1 Monitoring side
VRF network system
consumed when billing users for air
conditioning power charges. Air conditioning control function Timer
Electricity On / Off   Period Year Year
charges
Signal line* Operation mode setting   Schedule timer On/off, Temp,
• Apportionment charge/bill calculation 20 20
• Tenant (block) setting Block (Tenant) A Fan speed setting   Mode, Times per day

• Common facilities apportionment setting Room temp. setting   On/off timer - -


• Rated power consumption allotment setting
Room temp. set point limitation   Sleep timer - -
• Individual calculation at cooling and heating Block (Tenant) B
• Electricity meter supported Test operation   Program timer - -
LAN cable
Up/down air direction flap setting   Auto off timer - 
*: Electricity meter (1unit) can be connected to external input connector of the TPC unit. Right/left air direction flap setting   Day off  
In this case, electricity meter cannot be connected to outdoor unit simultaneously.
Individual louver control *1  Min. unit of timer setting (Minutes) 10 10

Group setting   Control


Automatic summer time setting RC prohibition   Status monitoring system  

Providing function Automatic clock adjustment Anti freeze setting   Electricity charge apportionment  

Set temp. auto return -  Error history  


1) Schedule setting of summer time setting 2) The time setting of each controller can be set in batch automatically.
• It prevents the user from forgetting to set summer time. In Various energy saving control -  Emergency stop *2 *2
addition, it reduces the time and labor of user. Economy mode setting   Remote management - 

Human sensor control -  Energy saving management - -

Custom Auto setting   E-mail notification for malfunction - 

Display 
Key lock -
Error   Password setting

Defrosting   Low noise mode  

Current time  

Day of week  

Outdoor low noise operation R.C. prohibition  

Cooling/heating priority  
Users can choose from 4 low noise levels, depending on the installation Quiet priority setting
environment. Address display  
Air
The operaion time can be set using the timer. conditioning Room temp  
load factor Heat load
Multi language  
100% down Summer time  
Capacity
0 Time zone setting  
Block (Tenant) A
Operating 58dB Name registration  
sound
0 Backlight  
Block (Tenant) B
time
Quiet priority low noise mode Language setting 7 7+other

 : Supported : Optional function - : Not supported yet


*1 Only setting cancellation can be operated.
*2 This function is available only through external input control.

Energy saving control


Custom Auto Cooling set temp. 27˚C, Heating set temp. 26˚C

• Maintains 2 separate set points for heating and cooling.


• Automatically changes mode between heating and cooling.
* This function is not available for some models. Auto
Operation Start
Changeover
Specifications
Change over
Cooling Set Point Model name UTY-DTGGZ1

Heating Set Point Power Supply 100-240V 50/60Hz, Single phase


Change over Dimensions (H x W x D) mm 260 × 246 × 54
Weight g 2,150
Room temperature Interface Transmission / LAN / USB / EXT IN / EXT OUT / Reset SW

118 119
AIRSTAGE Control Systems Centralized Controller
TM

System Controller 3rd party devices connected by


Max. controllable Max. controllable Max. controllable
for System Controller for System Controller Lite UTY-PLGXX2
4 1,600 400 Modbus can be controlled.
VRF network systems indoor units outdoor units

When Modbus Adaptor (locally purchased) is connected to PC, the


UTY-APGXZ1 electric facilities supported by Modbus can be controlled centrally.
Wasteful electricity charge by forgetting to turn off and patrol
System Controller realizes the advanced integrated monitoring & control of activities can be reduced in the entire building.
VRF network system from small scale buildings to large scale buildings.
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units Lighting facilities
can be controlled.
Supported Modbus communication Energy recovery ventilator system
• In addition to air conditioning precision control function, central remote control, (Field supply)
electricity charge calculation, schedule management, and energy saving functions are Supply & Exhaust fan
strengthened and building manager and owner needs are met.
Remote I/O

VRF Network

System Controller Lite


Max. controllable Max. controllable Max. controllable Signal Line

1 400 100 Electricity


VRF network system indoor units outdoor units Electric power
System Controller meter
company
(System Controller Lite)
UTY-ALGXZ1

System Controller Lite has standard functions sufficient for air


conditioner management in small and medium scale buildings.
Diverse operation management & Data management
• Up to a maximum of 1 VRF network system, 400 indoor units, and 100 outdoor units can
be controlled. Schedule management
• In addition to air conditioning precision control function, a variety of management
• Annual schedules can be set for each remote controller group / user defined group.
software is available as an option to give customers a wide range of choice.
• Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up
to 143 times per day at 10 minute intervals for up to 101 configurations for each remote controller
group.
• Settings can be made for periods straddling midnight.
Functions • Allows programming of special settings for holidays, including public holidays, for a complete year.
• Low noise operation of outdoor unit can be scheduled.
User friendly view and operation
• Click & Operate : The property is shown visually from the • Freely define groups for batched control : Indoor units can Diverse control of indoor and outdoor unit Error display & E-mail notification
perspective most suitable for operation and operated accordingly be freely grouped for simple batched control from a tree menu. • Indoor unit operation state, operation mode, etc. are displayed Error is notified with popup message, audible sound and E-mail real
(Click & Operate). You can select from among the 4 displays of site, Grouping by hierarchal structure, such as by section, division or • Indoor unit start / stop and operation mode switching time when error occurs. Error for the past 1 year are logged and can
building, floor, or list. department is possible. • Room temperature set point limitation be reviewed later.

Click & Operate the whole building ! Properties can be shown using one of the four Click & Operate any specified unit(s)!
displays of site, building, floor, or list.
Remote controller prohibition Data base import/export
This prohibits changes to the operation mode, temperature, Imports/exports registration data, layout data, and image data.
start/stop, etc. Only the administrator can make this setting.
The display is easily changed by pressing the button.

Automatic clock adjustment Operating & control record


The time setting of each controller can be set in batch automatically. Displays the history of operation status and control.

Site view List view

Web Operation
PC and smartphones can be used as
simple remote controller.
Batched control of freely WAN*1 (Intranet)
defined groups (Indoor unit user setting is necessary to ON/OFF
operate it from System Controller side) Temperature setting
Check remaining amount*2
Wi-Fi LAN (Intranet)
Batched control of freely selected units Mode setting
HUB
Fan speed
Building view Louver setting
Wireless LAN access point System Controller
*2: prepaid AC function
The floor layout drawing
Note: can be imported to easily
2D floor layout / 3D building make the settings for the PC
display are not available for Click & Operate the whole floor ! actual building.
System Controller Lite. *1:For connection via the Internet, the following setting is necessary.
Floor view ・Fix IP address (or similar)
Click & Operate the unit !
Batched control of freely selected units ・Open the router’s port of No.80.

120 121
AIRSTAGE Control Systems Centralized Controller
TM

Functions FUNCTIONS SUMMARY


System controller System controller lite
Function Type
Electricity charge apportionment for System Controller for System Controller Lite UTY-PLGXA2
Max. VRF networks supported
UTY-APGXZ1
4
UTY-PEGXZ1
-
UTY-ALGXZ1
1
UTY-PLGXR2
-
UTY-PLGXA2
-
UTY-PLGXE2
-
UTY-PLGXX2
-
Max. indoor unit / remote controller groups per VRF network 400 - 400 - - - -
Electricity charge apportionment calculation framework System Configuration Example System
Max. outdoor units per System controller 100 - 100 - - - -
specification
Max. indoor units / remote controller groups per System controller 1600 - 400 - - - -
Suppose you want to find the power consumed by the air conditioners of Electric power Electricity charges (air conditioning) Max. outdoor units per System controller 400 - 100 - - - -
company RB Unit Signal transmission line Multi site display 10 - 10 - - - -
each tenant from the electricity charge for each month. With electricity Number of building / 1 site 20 - - - - - -

charge apportionment function, used energy apportionment ratio will be System Controller Number of floor per 1 site
Number of floor per 1 building
200
50
-
-
-
-
-
-
-
-
-
-
-
-
Site
provided, calculating in detail the energy consumed by the units used by Power supervision
3D graphical layout view  - - - - - -
distribution 2D graphical layout view  - - - - - -
each tenant. This information is then used to calculate the charges for the board
Tenant A-1 Tenant A-2 Tenant A-3
List display  -  - - - -
electricity consumed for air conditioning by each tenant from the total Tree display
Group display


-
-


-
-
-
-
-
-
-
-
Power
electricity charges in the bill from the electric power company. (See figure distribution Error
Error notification  -  - - - -
Outdoor Tenant A-4 Tenant A-5 Tenant A-6 Audible alarm  -  - - - -
board
at right) unit
management
Error e-mail notification  -  - - - -
The detailed calculation takes into consideration such things as unused History
Error history
Operation history


-
-


-
-
-
-
-
-
-
-
rooms and nighttime electricity charges and shows them in a charges Control history  -  - - - -
Tenant B-1 Tenant B-2 Tenant B-3 On/Off  -  - - - -
calculation sheet. Operation mode  -  - - - -
Room temperature  -  - - - -
Fan speed  -  - - - -
3Ø, 4 wire 400V, 50Hz Individual Air flow direction  -  - - - -
Tenant C-1 Tenant C-2 Tenant C-3 1Ø, 2wire 230V, 50Hz control Economy mode  -  - - - -
Room temperature set point limitation  -  - - - -
Operation Test operation  -  - - - -
control Antifreeze  -  - - - -
Outdoor unit low noise setting  -  - - - -
Remote control prohibition setting  -  - - - -
Individual

Remote management
Temperature upper and lower limit setting  -  - - - -
for System Controller for System Controller Lite UTY-PLGXA2 management
Filter sign reset  -  - - - -
Memory operation  -  - - - -
Other Pattern operation  -  - - - -
System Controller may be used on site or remotely Remote central control Remote central control Web operation  -  - - - -
over various networks for remote central control. 1 VRF Controller can be monitored from any number 1 VRF Explorer can control or monitor up to 10 sites. Annual Schedule  -  - - - -
of VRF Explorers (Up to 5 connections simultaneously). Special day setting  -  - - - -
System Controller requires On /off per day 72 - 72 - - - -
Schedule On / off per week 504 - 504 - - - -
2 softwares working together. VRF Controller runs VRF Explorer Building Management Company A
(In charge of the day shift)
VRF Explorer
Day off  -  - - - -
VRF Explorer VRF Controller Building management company,
on site and communicate with VRF system. VRF VRF Explorer
A maximum of
management center, etc. Min. unit of timer setting (Minutes) 10 - 10 - - - -
10 locations, such as Low noise mode Weekly schedule  -  - - - -
Explorer runs remotely and provides user interface offices or factories
Remote monitoring  - -  - - -
Building
and communicate with the VRF Controller. VRF Management Company B
(In charge of the night shift) Internet
or
Office Management Center
Remote
managemment
Remote operation control
Remote function setting


-
-
-
-


-
-
-
-
-
-
Controller and VRF Explorer program may run in a VRF Explorer
Telephone Line
or
LAN
VRF Controller Internet
or
Web Remote Controller  - -  - - -
Telephone Line Apportionment charge/bill calculation  - - -  - -
single PC or in different PCs separated by network. or
LAN Tenant (block) setting  - - -  - -
Electricity
By using VRF Explorer software, one PC can Security Company
VRF Explorer
charge
Common facilities apportionment setting
Rated power consumption allotment setting


-
-
-
-
-
-


-
-
-
-
apportionment
perform central control of 10 VRF system sites with Headquarters
Management Center
Individual calculation at cooling and heating - * - -  - -
Electricity meter supported -  - -  - -
max. 20 buildings per site. Indoor unit rotation -  - - -  -
Peak cut control -  - - -  -
Energy Outdoor unit capacity save -  - - -  -
saving Record of energy saving operation -  - - -  -
management Energy saving information -  - - -  -
Power consumption monitor - - - -  -
Energy saving management

for System Controller UTY-PEGX for System Controller Lite UTY-PLGXE2 Electricity meter supported  - -  -
External Device Monitor  - - - - - 
Control Control  - - - - - 

Peak cut operation


Database import/export  -  - - - -
A variety of energy saving operations can be set and managed Others Automatic clock adjustment  -  - - - -
depending on the season, weather, and time period. Excellent energy Multi language 7 languages - 7 languages - - - -

saving operation is performed while keeping users comfortable. A power meter is connected to detect the total power consumption : Available. - : Not available. *:Power calculation application software is necessary, please contact the local FGL representative.

while shifting the indoor unit set temperature, set the indoor unit
forced thermostat off, and taking other measures to carefully control
the power consumed while Personal computer system requirements
Forced thermostat off range
maintaining comfort and The required PC specifications are shown in the following table.
Outdoor unit stop range Target power consumption
conducting control to System Controller System Controller Lite
maintain the target power • Microsoft® Windows® 7 Home Premium (32-bit or 64-bit) SP1, Windows® 7 Professional (32-bit or 64-bit) SP1
Energy saving graph data:
consumption set for each Operating system
• Microsoft® Windows® 8.1 (32-bit or 64-bit), Windows® 8.1 Pro (32-bit or 64-bit)
This graph compares the electricity • Microsoft® Windows® 10 Home (32-bit or 64-bit), Windows® 10 Pro (32-bit or 64-bit)
consumption with the previous month time. The indoor units to Ideal control line [Supported languages] English, Chinese, French, German, Russian, Spanish, and Polish
and previous year to make it easy to be controlled can be freely (Use of average
power consumption) CPU Intel® CoreTM i3 2 GHz or higher
analyze the energy saving effect. grouped and the control Memory • 2 GB or more (for Windows® 7 [32-bit]) • 4 GB or more (for Windows® 7 [64-bit], Windows® 8.1, and Windows® 10)
Energy Saving Management Main Screen level can be set. Shows change in power consumption by time
HDD 40 GB or more of free space355
Display 1024 x 768 or higher resolution
•Ethernet port (for getting access to the Internet using LAN) or •Ethernet port (for getting access to the Internet using LAN) or
Indoor unit rotation operation Outdoor unit capacity save Modem (for getting access to the Internet using Public Telephone Line) Modem (for getting access to the Internet using Public Telephone Line)
•USB ports (Maximum of 6 ports) •USB ports (Maximum of 6 ports)
The operation of indoor units can be automatically rotated within a Outdoor unit capacity save switches the outdoor unit capability upper Interface (Required only for the Server PC that works as VRF Controller) (Required only for the Server PC that works as VRF Controller)
- Maximum of 2 USB ports are required for WHITE-USB-KEY/WibuKey connection - Maximum of 4 USB ports are required for WHITE-USB-KEY/WibuKey connection
group in accordance with the set annual schedule to reduce power limit to suppress power consumption during hot summers and cold - Maximum of 4 USB ports are required for Echelon® U10 USB Network Interface - 1 USB port is required for Echelon® U10 USB Network Interface
consumption while maintaining comfort. The indoor unit operation winters by averaging the power saving effect of each refrigerant * Maximum number of required USB port depends on the applicable system configuration. * The maximum number of required USB port depends on the applicable system configuration.

stoppage rate can be selected. system. You can select from 50% or more of the capacity upper limit. Graphic accelerator Microsoft® DirectX® 9.0c compatible
Software Adobe® Reader® 9.0 or later

Outdoor unit • Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)re.
Hot day of
Power consumption

summer capacity <PACKING LIST>


upper limit
For System controller For System controller Lite

Cold day of Type System controller System Controller Lite


Energy manager Remote access Electricity charge apportionment Energy saving Central Control
winter
Model name UTY-APGXZ1 UTY-PEGXZ1 UTY-ALGXZ1 UTY-PLGXR2 UTY-PLGXA2 UTY-PLGXE2 UTY-PLGXX2
Outdoor unit capacity
Indoor unit rotation screen control screen Time WHITE-USB-KEY 1 1 1 1 1 1 1
*1: Software protection key to be inserted in a USB slot running System Controller or System Controller Lite.
System Controller or System Controller Lite may only run on a PC with WHITE-USB-KEY. However, WHITE-USB-KEY is not required for remote VRF Explorer software.

122 123
AIRSTAGE Control Systems Convertor / Adaptor
TM

BACnet® Gateway BACnet® Gateway (Hardware)


Max. controllable Max. controllable Max. controllable Max. controllable Max. controllable Max. controllable

4 1,600 400 1 32 128


VRF network systems indoor units outdoor units VRF network system refrigerant system indoor units

UTY-ABGXZ1 UTY-VBGX

• It is possible to connect medium to large sized BMS to VRF network system via BACnet®, a global standard for open networks. • BACnet® Gateway enables to connect a BMS and FG VRF system.
• A maximum of 1600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 100 outdoor units for one network • A maximum of 128 indoor units and 32 refrigerant system can be connected to a single BACnet® Gateway.
system) can be connected to one BACnet® Gateway. WHITE-USB-KEY • Compatible with BACnet® (ANSI / ASHRAE-135-2010) application specific controller (B-ASC).
• It is possible to control or monitor VRF network system from BMS via BACnet® Gateway. (Software Protection Key) • Compatible with BACnet®/IP over Ethernet.
• Compatible with BACnet® (ANSI / ASHRAE-135-2012) application specific controller (B-ASC).
• Compatible with BACnet®/IP over Ethernet.
• Scheduling function, Alarm & Event functions as well as Electricity Change Apportionment function are provided in BACnet® Gateway.
• Connection between VRF network system to personal computer is possible via small U10 USB interface. However, both U10 USB
Functions
interface & personal computer are field supplied items.
• Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
Installation example
Max.128 indoor units &
Max.32 refrigerant system

Functions VRF Indoor unit


Controller
BACnet® Gateway
Installation example Lighting facilities
(Hardware) VRF Indoor unit

Security system
BACnet® Operator
Workstation (B-OWS) Automatic fire alarm interface
VRF network system 1 BACnet®
®
BACnet BACnet ® Operator
Windows bind VRF Outdoor unit

USB adaptor*1 Workstation (B-OWS)


(Field supplied)
Indoor unit
Specifications
Outdoor unit
Model name UTY-VBGX Model name UTY-VBGX

Lighting facilities Number of controllable indoor units 128 Power Supply 208-240V 50/60Hz, single phase
Number of controllable refrigerant system 32 Power Consumption W 4.6 (max)
VRF network system 2
Number of controllable VRF network 1 Dimensions (H x W x D) mm 59.6 × 270.4 × 176
Security system Number of connectable units / one VRF etwork 4 Weight g 1,200
USB adaptor
(Field supplied)
BACnet® Gateway Automatic fire alarm interface
Indoor unit Outdoor unit (UTY-ABGXZ1)

Network Convertor for LONWORKS®


USB adaptor Ventilation system Max. controllable Max. controllable Max. controllable
(Field supplied) WHITE-USB-KEY
Software Protection Key 4 128 100
Units to BMS indoor units outdoor units
= USB cable
= Transmission line (VRF Network)
Max. 4 VRF network systems USB adaptor = Ethernet UTY-VLGX
(Field supplied)
*1: USB adaptor is U10 USB Network Interface of Echelon® Corporation.
• For connection between VRF network system and a LONWORKS® open network for
management of small to medium-sized BMS and VRF network system.
• The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS
through a LONWORKS® interface.
• Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®

Personal computer system requirements Functions


UTY-ABGXZ1
• Microsoft® Windows® 7 Home Premium (32-bit or 64-bit) SP1, Windows® 7 Professional (32-bit or 64-bit) SP1
• Microsoft® Windows® 8.1 (32-bit or 64-bit), Windows® 8.1 Pro (32-bit or 64-bit)
Installation example
Operating system • Microsoft® Windows® 10 Home (32-bit or 64-bit), Windows® 10 Pro (32-bit or 64-bit) Max.128 indoor units &
[Supported languages] Max.100 outdoor units
English, Chinese, French, German, Russian, Spanish, and Polish
VRF Indoor unit
CPU Intel® CoreTM i3 2 GHz or higher Controller
• 2 GB or more (for Windows® 7 [32-bit]) Network Convertor
Memory Lighting facilities
• 4 GB or more (for Windows® 7 [64-bit], Windows® 8.1, and Windows® 10) for LONWORKS® VRF Indoor unit

HDD 40 GB or more of free space Security system


General-purpose
Display 1024 x 768 or higher resolution building control computer Automatic fire alarm interface LONWORKS®
(LONWORKS® device)
• Ethernet port (for getting access to the Internet using LAN) Network VRF Outdoor unit
Windows bind
• USB ports (Maximum of 5 ports)
Interface - 1 USB port is required for WHITE-USB-KEY/WibuKey connection
- Maximum of 4 USB ports are required for Echelon® U10 USB Network Interface
* Maximum number of required USB ports depends on the applicable system configurations. Specifications Transmission specifications (BMS side)
Software Adobe® Reader® 9.0 or later
•Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.) Model name UTY-VLGX Transmission speed 78 kbps
Power Supply 208-240V 50/60Hz, Single phase Transceiver FT-X1 (Echelon® Corporation)
<PACKING LIST> Power Consumption W 4.5 Transmission way form Free topology
Name and shape Quantity Application Dimensions (H x W x D) mm 67 × 288 × 211 None
Terminal resistor
WHITE-USB-KEY 1 Includes the software and manuals, license for BACnet® Gateway. Weight g 1,500 (It attaches at the terminal of a network.)

124 125
AIRSTAGE Control Systems Convertor / Adaptor
TM

MODBUS® Convertor MODBUS® Interface


Max. connectable Max. controllable Max. controllable Max. controllable

9 128 100 1
units to one VRF indoor units outdoor units Single indoor unit

UTY-VMGX FJ-RC-MBS-1

The MODOBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. The Modbus Interface allows a complete integration of
• Compact and lightweight design
air conditioners into Modbus Networks.
• Direct connection to MODBUS Network • Simple installation due to small and compact size.
• Up to 128 indoor units can be controlled in one MODBUS Convertor • No separate external power supply required.
• The MODBUS Convertor permits central monitoring and control of air conditioners from BMS or Central Controller. • The Modbus Interface permits central monitoring and control of air conditioners from BMS.

Functions Functions

Max. 63
Modbus Network
MODBUS Network Modbus Interface The Modbus Interface can be used with
VRF System (Lon Network) or without Wired Remote Controller.

BMS/Central
Controller
Controller VRF Indoor unit
MODBUS Convertor
BMS/Central Lighting facilities
for VRF VRF Indoor unit VRF Indoor unit
Controller Security system
VRF Indoor unit
Automatic fire alarm interface VRF Outdoor unit

Windows bind
* BMS : Bulding Management System Wired Remote
Controller Split Indoor unit

Specifications
Model name UTY-VMGX
Specifications
Power Supply 220-240V 50/60Hz
Input power W Max. 2 Model name FJ-RC-MBS-1
Dimensions (H x W x D) mm 54 × 260 × 150 Dimensions (H x W x D) mm 93 × 53 × 58
Weight g 1,100 Weight g 85

MODBUS® Convertor for Indoor Unit KNX® Interface


Max. controllable Max. controllable

1 1
Single indoor unit group

UTY-VMSX FJ-RC-KNX-1i

The MODBUS Convertor allows a complete integration of air conditioners into MODBUS Networks. The KNX Interface allows a complete integration of air
• Simple installation due to small and compact size.
conditioners with KNX Network systems.
• No separate external power supply required. • Simple installation due to small and compact size.
• The MODBUS Convertor must be connected one by one in the indoor unit. • No separate external power supply required (just KNX bus power).
• The MODBUS Controller permits central monitoring and control of air conditioners from BMS/Central/Home Controller. • Can be used for single indoor units and group controlled (up to 16) indoor units

Functions Functions

MODBUS Network KNX Network


The KNX Interface can be used with or
without Wired Remote Controller.
Home Controller
BMS/Central/ KNX VRF Indoor unit
Home Controller Lighting facilities Lighting facilities
VRF Indoor unit
Security system or
Security system
Automatic fire alarm interface
MODBUS Convertor Automatic fire alarm interface Wired Remote
Windows bind
Split Indoor unit
Controller
Windows bind

Specifications
Model name UTY-VMSX Temperature Operating / Packaged ºC 0~46 / -10~60
Specifications
Power Supply DC12V Humidity Operating / Packaged % 0~95 / 0~95
Input Power W Max. 1.2 Maximum Connectable indoor unit number Model name FJ-RC-KNX-1i
1
Dimensions (H x W x D) mm 140 × 117 × 43 per 1 MODBUS Convertor Dimensions (H x W x D) mm 70 × 70 × 28
Weight g 200 Weight g 70

126 127
AIRSTAGE Control Systems Convertor / Adaptor
TM

KNX® Convertor (for VRF) Wireless LAN Interface


Max. controllable Max. controllable Max. controllable

128 100 1
indoor units outdoor units Single indoor unit

UTY-VKGX UTY-TFSXZ1

It is possible to control the VRF system from central / home controller via KNX network. • It is the most advanced solution to remotely manage an Air Conditioning system using
all sort of mobile devices such as Smartphones, and tablets.
• New KNX Convertor enables to connect central/home controller and FG VRF system. • No separate external power supply required
• A maximum of 128 indoor units and 100 outdoor units can be connected to single KNX Convertor. • Can be used for single indoor units and multi system indoor units

Functions

KNX Convertor for VRF VRF network

Functions

Central / Home
Registrable Download Free
Controller
128 indoor units
100 outdoor units

Wireless LAN
Specifications Interface

Model name UTY-VKGX


Internet
Indoor unit
Power Supply 220-240V 50/60Hz
Input power W 1.5 Tablet
Dimensions (H x W x D) mm 54 × 260 × 150
Weight g 1,200

Router
Smartphone (Locally purchased)

Smartphone

KNX® Convertor (for Indoor unit)


Max. controllable

1
Single indoor unit

Basic control Error display & E-mail notification


UTY-VKSX
• Turning the units on and off • Alerts e-mail notification
• Mode control (Heat, Cool, Dry, Auto, Fan) • Air conditioning malfunction display
It is possible to control the VRF system from central / home controller via KNX network. • Fan speed setting • It enables rapid service response when error occurs.
• New KNX Convertor enables to connect central/ home controller and FG indoor unit. • Louver position (Airflow direction setting)
• Compact and light weight design • Timer operation setting (Weekly timer)
• Economy mode setting
Internet

Multi system Indoor unit


Functions

Single split indoor unit Indoor unit


Internet

Router
(Locally purchased)

Indoor unit
Central / Home
Controller
KNX Convertor
Multiple air conditioning management
for indoor unit Outdoor unit Smartphone • Multiple air conditioning management at difference locations.

Specifications
Model name UTY-VKSX
Specifications
Power Supply (DC12V)
Input power W 0.6 Model name UTY-TFSXZ1
Dimensions (H x W x D) mm 140 × 117 × 43 Dimensions (H x W x D) mm 71 × 38 × 15
Weight g 250 Weight g 85

128 129
AIRSTAGE Control Systems Convertor / Adaptor
TM

Wireless LAN Interface Network Convertor


Max. controllable Max. controllable Max. controllable

1 16 100
Single indoor unit single indoor units Network Convertors

FJ-RC-WIFI-1 UTY-VTGX (DC power supply type)


UTY-VTGXV (AC power supply type)
• It is the most advanced solution to remotely manage an Air Conditioning system using
all sort of mobile devices such as Smartphones, Tablets and PC
• No separate external power supply required Compact remote controller provides access to basic functions
• Can be used for single indoor units and group controlled (up to 16) indoor units
• The network convertors are required when connecting single split
system to VRF network system.
• Compact and light weight design
• Connectable to both types of 2-wire and 3-wire remote controllers

UTY-VTGX UTY-VTGXV
DC power supply type AC power supply type

Functions Functions

Installation example
• 2 types of 1 remote controller type and 2 remote controllers type are available.
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote controllers type.
Indoor unit
Internet Smartphone

VRF network System


Wireless LAN
Interface Tablet

Network Convertors Network Convertors


Router (for 1 remote controller) (for 2 remote controllers)
(Field supplied)
PC AC230V

Basic control
• Turning the units on and off • Room temperature display (Application screen image)
• Mode control (Heat, Cool, Dry, Auto, Fan) • Set temperature control
• 2-wire and 3-wire type of the wired remote controller can be • A central control can be provided for the single split systems. (Up to
• Fan speed setting • Multi Language
connectable. 100 units of Network Convertor is connectable in one VRF network
• Louver position (Airflow direction setting) • One Scene and Timer
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote system)
controllers type.

VRF network System VRF network System

Up to 100 units of
Network Converter

Advanced control (Optional functions) Notifications and History


• Climate working modes (ECO, Comfort, Powerful) (future release) • Alerts e-mail notification (future release)
• Schedulable functionalities (ON/OFF, Modes, Set point temperature, • Air conditioning malfunction alerts
Fan Speed, Louver position) • Connectivity monitoring and alerts
• Set temperature limitation (future release) • History (future release)
• Multiple Scenes & Timers and Calendar function

Specifications
Model name UTY-VTGX UTY-VTGXV
Specifications
Power Supply polar 3-wire DC12V non-polar 2-wire DC12V 220-240V 50/60Hz, Single phase
Model name FJ-RC-WIFI-1 Input power W Max. 1.2 Max. 3
Dimensions (H x W x D) mm 108 × 70 × 28 Dimensions (H x W x D) mm 140 × 117 × 43 54 × 260 × 150
Weight g 80 Weight g 250 1,100

130 131
AIRSTAGE Control Systems Convertor / Adaptor
TM

Network Convertor External Switch Controller


Max. controllable Max. controllable Max. controllable

16 4 1
single indoor Group Remote group
units Controllers

UTY-VGGXZ1 UTY-TERX

• This Network Convertor is to be used for connecting single split system or • In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the
Group Remote Controller (UTY-CGGY / UTY-CGGG) with the VRF network system. ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations
• Please select the function by switching the dip switch during the installation. such as hotel rooms.
• Card-key or other sensor switches are available as a locally purchased parts.
• 2-wire type
• The set temperature can be specified at two points for cooling and heating individually (4 points).

Functions

Installation example
Human sensor catches movements of
Functions people in a room, and operates with lower
capacity when people come back to the
SAVE ! AUTO RESTART
room, it automatically returns to previous +2°C *Max. 30°C
Used for connecting single split system operation mode.
Cooling/Dry
Set temp. Human sensor equipment needs to be
Network Convertor purchased locally. The above example
• Split type systems can be centrally controlled from Touch Panel Heating indicated that a signal is sent to this
Controller or System Controller through connection to the VRF’s Set temp. -4°C *Max. 16°C External Switch Controller if human
sensor does not detect for 20 minutes.
network convertor. Human sensor is not mounted on the
• On / Off Control, Master control, Room temperature and Fan speed Normal operation Saving operation Normal operation External Switch Controller.
setting via the Network Convertor are available.
• One Network Convertor can be used to connect and control up to 16
Specifications
single units. Group of Single Split
Single Split
Model name UTY-TERX
Power Supply DC 6.5-16V
VRF network system Dimensions (H x W x D) mm 140 × 117 × 43
USB Weight g 250
Adaptor
DC12V is supplied by indoor unit.
System Controller

Big Multi

Signal Amplifier
Please consult your distributor for connectable split type air conditioner.
Up to 100 Network Convertors may be connected in single VRF network system.
One Network Convertor is considered as a single refrigerant system,
irrespective of the number of connected single models.

UTY-VSGXZ1

Used for connecting • Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers.
• Up to 40 signal amplifiers can be installed in a VRF network system.
Group Remote Controller • A signal amplifier is required,

4 Group Remote Controllers can be connected to a single Network (1) When the total wiring length of the transmission line exceeds 500m.
Group (2) When the total number of units on the transmission line exceeds 64.
Convertor (UTY-VGGXZ1). Remote Controller
UTY-CGGY
UTY-CGGG
Functions

Installation example
Network Convertor
B
VRF network system

C
* 2 refrigerant circuits can be covered by a single Network Convertor (UTY-VGGXZ1) .
Up to a total of 16 Network Convertors (UTY-VGGXZ1) and System Controller
A D
adaptors can be connected in a single VRF network system.

Signal Amplifier

Specifications Specifications
Model name UTY-VGGXZ1 Model name UTY-VSGXZ1
Power Supply 208-240V 50/60Hz, Single phase Power Supply 208-240V 50/60Hz, Single phase
Input power W 8.5 Input power W 4.5
Dimensions (H x W x D) mm 67 × 288 × 211 Dimensions (H x W x D) mm 67 × 288 × 211
Weight g 1,500 Weight g 1,500

132 133
EFFECTIVE FRESH AIR TREATMENT

To facilitate the use of third party air handling units of various cooling capacity range

from 5 to 50kW to work with our VRF air conditioning systems.

VENTILATION
Outdoor Air Unit
DX-Kit for airhandling applications

134 135
Ventilation

Outdoor Air Unit High energy savings and flexible duct


design by using DC motor
Various Controller
Supplied variety of controllers as options, such as individual
controller , central controller , and building management
• Greatly reduces electricity
controller.
Models consumption by adopting
ARXH054GTAH permanent magnet Individual Controller
compared to when using an
ARXH072GTAH AC motor.
054 / 072 type 096 type

ARXH096GTAH • Compared with AC motor, changing the speed makes it possible


ARXH054GTAH ARXH072GTAH
to respond flexibly to the external static pressure from 50 Pa to
The heat pump method 240 Pa. Even if damper equipment is not used, static pressure
efficiently processes the outdoor air can be adjusted and duct design is easy.
for cooling and heating and Wireless Simple Wired Wired
• Static pressure can be set easily using wired remote controller. Remote Controller Remote Controller Remote Controller Remote Controller
supplies 100% fresh air into a room. (Touch Panel)

(When external static (When external static


pressure is small) 50 to 240 Pa pressure is large)
(096 type)
Low speed High speed
ARXH096GTAH Central Controller
DC Motor

One VRF system can provide air conditioning and air supply at the same time. High speed
(Constant)
High speed
(Constant)
Outdoor Air Unit can be connected in a same VRF*1 system as one AC Motor
of indoor unit series and can create fresh and comfortable air supply
together from our high advanced technology. VRF system Damper opening small (Field supplied) Damper opening large (Field supplied)
Duct Group Central Touch Panel System Controller
Remote Controller Remote Controller Controller System Controller Lite
*1. Connectable VRF series:J-IIS, J-II, V-II, V-lll, J-lll, J-lllL (Software)
In J-II series alone, OAU is prohibit to connect under
the ambient temperature of Indoor unit Indoor unit
40°C or higher.
Top class compact design * The temperature setting is discharged air temperature setting.
Fan The air volume is set to a constant speed.
Heat
• Top class lightweight compact design at just 425 mm in height,
Exchanger 55 kg in weight for ARXH072 type. This unit can be installed
Outdoor Air Unit Fresh Fresh
Air Air easily even at narrow space.
Outdoor Air
Unit
1367 mm
Wired R.C. Wired R.C. Wired R.C.

* Make sure the connected capacity is within the range of 50% to 100% of the outdoor
unit capacity. In addition, if there are mixed connections with indoor units, make the
55kg 425 mm
Outdoor Air Unit connection capacity 30% or less of the outdoor unit capacity. (072 type)
572 mm
(ARXH072 type)

Specifications
Dimensions (Unit : mm)

Rated flow rate 3 3 3


Models: ARXH054GTAH / ARXH072GTAH / ARXH096GTAH
1000 m /h 1500 m /h 2000 m /h

Model No. ARXH054GTAH ARXH072GTAH ARXH096GTAH ARXH054GTAH


Power source 230 /1/ 50 230 /1/ 50 230 /1/ 50 Main
drain port
Cooling 14.0 22.4 28.0
Capacity kW
Heating 8.9 13.9 17.4
Input Power Cooling / Heating W 179 292 370
Safety
Airflow Rate m3/h 1,080 1,680 2,100 drain port

Static Pressure Standard (range) Pa 185 (50-185) 200 (50-200) 200 (50-240)
Sound Pressure Level Side view (R)
dB (A) 42 44 47
Dimensions (H x W x D) mm 425×1,367×572 425×1,367×572 450×1,583×700 Side view (L) Top view
Weight kg 48 55 71
Connection Pipe Diameter (Small / Large) mm Ø9.52/ Ø19.05 Ø12.70/ Ø22.22 Ø12.70/ Ø22.22 (Drain hose)
Cooling 5 to 43 5 to 43 5 to 43
Operation Range ºCDB Front view
Heating -7 to 21 -7 to 21 -7 to 21
Refrigerant R410A R410A R410A
ARXH072GTAH ARXH096GTAH
Note : Specif ications are based on the followin g conditions .
Main drain port

Main
Cooling : Outdoor temperatur e of 33°CDB / 28°CWB. drain port

Heating : Outdoor temperatur e of 0°CDB / -2.9°CWB .


Pipe length : 7.5 m Voltage : 230 [V]. Safety
drain port

Safety
drain port

Side view (R) Side view (R)

Side view (L) Top view


Side view (L) Top view

(Drain hose) (Drain hose)

Front view Front view

136 137
Ventilation

DX-Kit for air handling applications Functions Summary

Inputs Outputs Modbus Control


• ON/OFF • ON/OFF indication • Possible to control via a Modbus enabled
Models • Setting temperature • Fan ON/OFF indication BMS by using optional interface.
Control unit • Capacity demand • Thermo ON/OFF indication
UTY-VDGX • Heating / Cooling operation mode • Defrost indication
• Fault information • Fault indication

EEV unit
UTP-VX30A Control unit
UTY-VDGX
UTP-VX60A
Installation Limitation
UTP-VX90A

• Connectable VRF series : All VRF Connectable capacity


These kits enable other manufacturers air handling units (AHU) and fan coil
units (FCU) to be incorporated into a General VRF system or, be connected to • Connectable DX-Kit system capacity range : 50 to 100% of the
• Single connection • Mixed connection
a dedicated General VRF outdoor unit as a 1:1 system to control outside air outdoor unit capacity
ventilation (AHU) or room temperature (FCU). EEV unit EEV unit EEV unit • Connectable DX-Kit system capacity range with indoor units :
UTP-VX30A UTP-VX60A UTP-VX90A 30% or less of the outdoor unit capacity
• Max. wiring length from control unit : 10 m DX-KIt DX-KIt
• Max. piping length between EEV unit and indoor unit : 5 m
Feature • Outdoor installation : Control unit (IP54 class) and EEV unit
can be installed at an outdoor space. Air Handling Unit Air Handling Unit

Multiple temperature sensors optimally control 50% –100% of outdoor unit capacity Within 30% of total capacity

the air handling unit and fan coil unit. [For 2EEV units connection (option)]
Arrangement as part of a VRF system • Separation Tube : UTP-LX180A 50%– 100% of outdoor unit capacity
AHU Thermistor
Transmission line
When connecting to an air handling unit, Indoor
Piping and wiring length
unit
the supply air temperature is controlled
DX-Kit by the discharge sensor. Air Handling Unit
EEV unit
VRF system
Max. piping length 5 m Control unit
Max. wiring length 10 m

Air Handling
FCU Unit
When connecting to a fan coil unit, the Control unit Max. wiring length 10 m
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor

Specifications
EEV unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A×2
Supports a wide range of capacity classes A variety of controls to match the application Power source V/Ø/Hz 230/1/50
Connectable capacity class kW 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0
• 2 EEV units can be connected in parallel and up to 20 HP (50 kW) • Central control using our VRF controllers or central management 5.6 6.3 8 10 12.5 14 22.4 25 40 50.4
Cooling
large capacity units. (Separation Tube of UTP-LX180A is required.) controllers (5.1-5.9) (6.0-7.1) (7.2-9.0) (9.1-11.1) (11.2-13.2) (13.3-18.0) (18.1-23.7) (23.8-28.0) (28.1-44.7) (44.8-50.4)
Capacity kW
• Connectable capacity range: 5 kW to 50 kW Heating
6.3 7.1 9 11.2 14 16 25 28 45 56.5
(5.7-6.7) (6.8-8.0) (8.1-10.0) (10.1-12.4) (12.5-15.0) (15.1-20.0) (20.1-26.5) (26.6-31.5) (31.6-49.9) (50.0-56.5)
EEV unit Transmission line Airflow Rate(Reference value) m3/h 1,060 1,200 1,520 1,600 2,000 2,240 3,560 4,000 6,400 8,000
External I/O
Dimensions (H × W × D) mm 160 × 220 × 90 (160 × 220 × 90)× 2
Interface Thermistor Weight kg 2 2×2
Piping (Option)
EEV unit DX-Kit Connection
AHU or FCU AHU or FCU Liquid mm 9.52 9.52 9.52 9.52 9.52 9.52 12.70 12.70 12.70 12.70
VRF Controller Modbus network
pipe diameter
(40 – 50 kW class)
(Future release)

Wiring Control unit Control unit UTY-VDGX


• Central control from external controllers
Power source V/Ø/Hz 230 / 1 / 50
Dimensions (H × W × D) mm 400 × 400 × 120
Thermistor
DDC* Weight kg 10
External I/O
Transmission line Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
DX-Kit AHU or FCU
3rd party Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
External I/O Controller Pipe length : 7.5 m Voltage : 230 [V].
*DDC=Direct Digital Controller

138 139
Auto Louver Grille Kit (Option)
Models
UTD-GXTA-W
UTD-GXTB-W
UTD-GXTC-W

Closed louver Opened louver

Feature

Flexible Control Dimensions

AIRSTAGE
TM
• Operation with indoor unit W2
Fitting Flame
Auto Louver can be operated by synchronizing remote controller of
indoor unit. Grille

• UP and Down auto swing

OPTION
• Auto airflow direction and auto swing
• 4 steps selectable H1 H2

• Auto-closing louver
W1 D1 D2
When operation of indoor unit is stopped, the louver will
automatically close.
Unit: mm

Auto Louver Grille Model Name W1 W2 H1 H2 D1 D2


Duct type
UTD-GXTA-W 683 645

UTD-GXTB-W 883 845 180 148 9 84

UTD-GXTC-W 1,083 1,045

Wired Remote Wireles Remote


Controller Controller

Specifications
Model name UTD-GXTA-W UTD-GXTB-W UTD-GXTC-W
ARXD04/07/09/12/14GALH ARXD18GALH ARXD24GALH
Applicable Indoor Unit
ARXK04/07/09/12/14GCLH ARXK18GCLH ARXK24GCLH
Power source Connecting with Control box of indoor unit
Fixing of Auto Louver Grille Screw fixing to Flange or Square Duct
Extension Square Duct Limit 1.0m (Max. duct length between indoor unit and Grille)
Dimensions (H × W × D) mm 180 × 683 × (84+9) 180 × 883 × (84+9) 180 × 1083 × (84+9)
Net 2.0 2.5 3.0
Weight kg
Gross 3.0 3.5 4.0
Color White
Louver Motor Stepping Motor
Accessories Fitting Flame, etc.
°C 18 to 32
Operation Cooling
% RH 80% or less
Range
Heating °C 16 to 30

*: The Auto Louver Grille Kit can also be installed to ARXD07/09/12/14/18/24LATH revision code B models. Please refer to the Design & Technical manual for ”revision code “ details.

140 141
AIRSTAGE Option TM

OPTIONAL PARTS LIST

Controllers / Interface Others


Indoor unit Indoor unit
Cassette Duct Floor Wall Mounted Cassette Duct Floor Wall Mounted
Mini Slim Medium Ceiling / Mini Slim Medium Ceiling /
4-way EEV Ceiling EEV EEV 4-way EEV Ceiling EEV EEV
4-way Circular Flow (With drain (With drain Static High Static Pressure - Floor - - - 4-way Circular Flow (With drain (With drain Static High Static Pressure - Floor - - -
Compact external external external Compact external external external
pump) pump) Pressure pump) pump) Pressure
Type Type
AUXB AUXB
AUXK AUXK
04GBLH, AUXA ARXK ARXD ARXC36 ARXC72/ AGHA AGHE ASHA ASHE 04GBLH, AUXA ARXK ARXD ARXC36 ARXC72/ AGHA AGHE ASHA ASHE
AUXD AUXM 018/024/ ARXA ABHA ABHA ASHA ASHE ASHA ASHA AUXD AUXM 018/024/ ARXA ABHA ABHA ASHA ASHE ASHA ASHA
AUXB 18/24/30/ 04/07/09/ 04/07/09/ GBTH, 90GBTH, 004/007/ 004/007/ 004/007/ 004/007/ AUXB 18/24/30/ 04/07/09/ 04/07/09/ GBTH, 90GBTH, 004/007/ 004/007/ 004/007/ 004/007/
18/24 018/024/ 030/034/ 24/30/36/ 12/14/18/ 30/36/45/ 012/014 012/014 18/24 030/034 18/24 018/024/ 030/034/ 24/30/36/ 12/14/18/ 30/36/45/ 012/014 012/014 18/24 030/034
07/09/12/ 34/36/45/ 12/14/18/ 12/14/18/ ARXC45/60 ARXC96 009/012/ 009/012/ 009 009 07/09/12/ 34/36/45/ 12/14/18/ 12/14/18/ ARXC45/60 ARXC96 009/012/ 009/012/ 009 009
GALH 030GLAH 036/045/ 45GBLH 24GATH 54GATH GCAH GCAH GBCH GTAH GALH 030GLAH 036/045/ 45GBLH 24GATH 54GATH GCAH GCAH GBCH GTAH
14/18/24 54GALH 24GCLH 24GALH GATH GATH 014GCAH 014GCAH GTAH GTAH 14/18/24 54GALH 24GCLH 24GALH GATH GATH 014GCAH 014GCAH GTAH GTAH
054GLAH 054GLAH
GALH GALH
Controllers

Others
IR Receiver
UTY-RNRGZ2 Unit UTY-LRHGB1 UTY-LBHXD UTB-YWC
Wired
Remote
Controller
Human
UTY-RLRG Sensor Kit UTY-SHZXC

Simple Remote
Remote Sensor
UTY-RSRG, UTY-RHRG, UTY-RSKG, UTY-RHKG New amenity space can be UTY-XSZX
Controller 2-wire type 3-wire type Unit offered by installing the
Remote sensor.

Wireless UTG-UKGC-W
Remote
Controller UTY-LNHG
UTG-UKGA-B
Cassette
Grille UTG- UTG-UKGC-W
UTG-UFGD-W UTG-UGGA-W
UFGD-W UTG-UKGA-B
Group
Remote
Controller UTY-CGGG + UTY-VGGXZ1 UTG-UGGA-W

Central Auto
Remote Louver UTD-GXTA-W
Controller UTY-DCGG Grille Kit UTD-GXTB-W(18)
UTD-GXTC-W(24)

Touch
Long Life
Panel UTD- UTD-
UTY-DTGGZ1 Filter
Controller LF25NA LF60KA

System
Controller,
UTD-
System Flange SF045T UTD-
UTY-APGXZ1, UTY-ALGXZ1
Controller UTD- RF204
Lite RF204
Interface

Drain
UTY- Pump UTZ- UTR-
UTY-TFSXZ1 UTY-TFSXZ1 UTY-TFSXZ1 Unit
TFSXZ1 PX1NBA DPB24T
Wireless
LAN
Interface Indoor unit 950
600
Panel
Wide 600
Panel UTG-AKXA-W
FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1 UTG-AKXA-W
UTG-AGYA-W
(mm)

(mm)

KNX UTY- Panel 242


Convertor UTY-VKSX UTY-VKSX UTY-VKSX UTY- VKSX Spacer UTG-BKXA-W
UTY-VKGX UTY-VKGX UTY-VKGX UTG-BKXA-W
UTY-VKGX UTY-VKGX UTY-VKGX VKGX UTY- UTG-BGYA-W
Panel spacer
VKGX

KNX Fresh Air


Interface Intake Kit UTZ-
FJ-RC-KNX-1i FJ-RC-KNX-1i FJ-RC-KNX-1i FJ-RC-KNX-1i For Compact For Cassette UTZ-VXRA UTZ-VXRA
Cassette
VXAA

UTY- Air Outlet For Compact Cassette


MODBUS
UTY-VMSX UTY-VMSX UTY-VMSX UTY- VMSX Shutter UTR-
Convertor UTY-VMGX UTY-VMGX UTY-VMGX UTR-YDZK UTR-YDZK
UTY-VMGX UTY-VMGX UTY-VMGX VMGX UTY- Plate YDZB
VMGX For Cassette

Insulation
MODBUS
for High UTZ- UTZ- UTZ-
Interface FJ-RC-MBS-1 FJ-RC-MBS-1 FJ-RC-MBS-1 FJ-RC-MBS-1 UTZ-KXRA
Humidity For Compact Cassette type / KXGC KXRA KXRA
Cassette type

External Half
Switch Concealed This kit is used to half
Controller UTY-TERX Kit UTR-STA
conceal floor type indoor
unit into the wall.

142 143
AIRSTAGE Option TM

OPTIONAL PARTS

Controllers Convertors / Adaptors

For Individual Control For External device


Wired Remote Controller (Touch Panel ) Wired Remote Controller Simple Remote Controller BACnet® Gateway Network Convertor for LONWORKS® MODBUS® Convertor for VRF MODBUS® Convertor for Indoor Unit
UTY-RNRGZ2 UTY-RLRG UTY-RSRG UTY-ABGXZ1 UTY-VLGX UTY-VMGX UTY-VMSX
With operation mode WHITE-USB-KEY (Software Protection Key)

WHITE-USB-KEY
(Software Protection Key)

MODBUS® Interface KNX® Convertor for VRF KNX® Convertor for Indoor Unit KNX® Interface
FJ-RC-MBS-1 UTY-VKGX UTY-VKSX FJ-RC-KNX-1i
Simple Remote Controller Wireless Remote Controller IR Receiver Unit
UTY-RHRG UTY-LNHG UTB-YWC
Without operation mode For All Duct types except Large Airflow Duct

Wireless LAN Interface Wireless LAN Interface


FJ-RC-WIFI-1 UTY-TFSXZ1

IR Receiver Unit Human Sensor Kit


UTY-LRHGB1 UTY-SHZXC
For Cassette type For Circular Flow Cassette type

For System expansion


Network Convertor for single split Network Convertor for single split Network Convertor External Switch Controller
for Group Remote Controller
UTY-VTGX UTY-VTGXV UTY-TERX
DC power supply type AC power supply type UTY-VGGXZ1

For Centralized Control


Signal Amplifier
Group Remote Controller Central Remote Controller Touch Panel Controller
UTY-VSGXZ1
UTY-CGGG UTY-DCGG UTY-DTGGZ1

UTY-PTGXA

Panels
System Controller Lite System Controller
UTY-ALGXZ1 UTY-APGXZ1
For Cassette type
Cassette Grille Cassette Grille Cassette Grille Cassette Grille
UTG-UFGC-W UTG-UGGA-W UTG-UKGC-W UTG-UKGA-B
UTY-PLGXR2 UTY-PEGXZ1 For Compact For Cassette type For Circular Flow For Circular Flow
Cassette type Cassette type Cassette type
UTY-PLGXA2
UTY-PLGXE2
UTY-PLGXX2

144 145
AIRSTAGE Option TM

OPTIONAL PARTS

Others

For Duct type Communication system: External Connect Kit


Flange (Round) Flange (Square) Remote Sensor Unit For Indoor unit For Outdoor unit
UTD-RF204 UTD-SF045T UTY-XSZX UTY-XWZXZ7 UTY-XWZXZD UTY-XWZXZ6
For Medium Static Pressure Duct type / Ceiling type For Medium Static Pressure Duct type For All Duct type
New amenity space can be
offered by installing UTY-XWZXZB UTY-XWZXZE UTY-XWZXZ9
the Remote sensor.

UTY-XWZXZC UTY-XWZXZF

For RB unit For Central Remote Controller For Touch Panel Controller
Long-Life Filter Auto Louver Grille Kit Drain Pump Unit
UTY-XWZXZ6 UTY-XWZXZ7 UTY-XWZXZA
UTD-LF25NA UTD-LF60KA UTD-GXTA-W (for ARXD04/07/09/12/14, ARXK04/07/09/12/14) UTZ-PX1BBA
For Medium Static For High Static UTD-GXTB-W (for ARXD18, ARXK18) For Low Static Pressure Duct type
Pressure Duct type Pressure Duct type UTD-GXTC-W (for ARXD24, ARXK24) UTY-XWZXZB UTY-XWZXZ8
For Slim Duct type / Mini Duct type UTZ-PX1NBA
For Medium Static Pressure Duct
UTY-XWZXZA

External Input and Output Function/External Connect Kit/Communication Kit


Indoor unit Outdoor unit Controller Other
For Cassette type Central Remote Touch Panel
Cassette Duct J-IIIL J-III J-IIS VR-II V-III RB Unit
Controller Controller
Wall
Wide Panel Panel Spacer Insulation Kit for High Humidity Mini Floor, Mounted, AJH
Type (With drain pump), Ceiling / 040/045/054 AJHA AJH UTP-RX01AH
4-way Compact, Floor Ceiling Wall AJH AJH
UTG-AKXA-W UTG-BGYA-W UTZ-KXRA 4-way,
Slim EEV external
Floor
Mounted 072/090/108
LBLAH,
040/045/054
072/090/108/ 072/090/108/
UTY-DCGG UTY-DTGGZ1
UTP-RX01BH
(With drain pump), EEV external AJH 126/144 126/144/162 UTP-RX01CH
Circular Flow LELAH LCLAH
For Cassette type For Cassette type For Cassette type Medium Static Pressure, 040/045/054 GALH LALBH UTP-RX04BH
High Static Pressure LELAH
(mm)
UTZ-KXGC

Function
Input
UTY-XWZXZD
Operation / Stop
UTY-XWZXZB
For Compact Cassette type
UTY-XWZXZ7 *2
All On / All Off
50 UTY-XWZXZ8 *2

Panel spacer Batch Stop UTY-XWZXZ6

UTY-XWZXZD
Fresh Air Intake Kit Air Outlet Shutter Plate Air Outlet Shutter Plate Forced Stop
UTY-XWZXZB

UTZ-VXAA UTZ-VXRA UTR-YDZB UTR-YDZK Emergency UTY-XWZXZD


UTY-XWZXZ6
UTY-XWZXZ7 *2
Stop UTY-XWZXZB UTY-XWZXZ8 *2
For Compact For Cassette type For Compact Cassette type For Cassette type
Cassette type Forced UTY-XWZXZE
Shuts the air outlet when only Shuts the air outlet when only Thermostat off UTY-XWZXZ7
using as 3 blow out. using as 3 blow out.
Low Noise
UTY-XWZXZ6
Mode Operation

Cooling/ UTY-XWZXZ6
UTY-XWZXZ6 UTY-XWZXZ6
Heating Priority UTY-XWZXZB
* Not applicable for VRF V-II tropical and V-III tropical series
Outdoor Unit
Operation Peak UTY-XWZXZ6
Control
Power Usage
*2
Information from UTY-XWZXZF
*2
Electricity Meter
For Ceiling type For Floor type
Output

Operation Status UTY-XWZXZC UTY-XWZXZ6 UTY-XWZXZA


Drain Pump Unit Half Concealed Kit
Error Status UTY-XWZXZC UTY-XWZXZ6 UTY-XWZXZA
UTR-DPB24T UTR-STA
For Ceiling type For Floor type Indoor Unit Fun
UTY-XWZXZC
Operation Status
This kit is used to half conceal
floor type indoor unit into the Auxiliary
wall. UTY-XWZXZC
Heater Output

Base Heater UTY-XWZXZ9

*2: Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary : Dry Contact : Apply Voltage
because Touch Panel Controller has an external input terminal block.

146 147
AIRSTAGE Option TM

OPTIONAL PARTS

Connection Units Specifications

Separation Tube Separation Tube


Model name UTP-AX054A UTP-AX090A UTP-AX180A UTP-AX567A
UTP-AX054A UTP-AX090A UTP-AX180A UTP-AX567A
Total cooling capacity of indoor unit kW 19.6 or less 28.0 or less 28.1 to 56.0 56.1 or more

Gas Pipe Gas Pipe Gas Pipe Gas Pipe


Model name UTP-BX090A UTP-BX180A UTP-BX567A

Total cooling capacity of indoor unit kW 28.0 or less 28.1 to 56.0 56.1 or more

Liquid Pipe Liquid Pipe Liquid Pipe Liquid Pipe

Header
3-6 Branches UTR-H0906L UTR-H1806L
UTP-BX090A UTP-BX180A UTP-BX567A UTP-LX180A for DX-Kit Model name
3-8 Branches UTR-H0908L UTR-H1808L
Suction Suction Suction
Gas Pipe Gas Pipe Gas Pipe Total cooling capacity of indoor unit kW 28.0 or less 28.1 to 56.0

Discharge Discharge Discharge 3-6 Branches UTP-J0906A UTP-J1806A


Gas Pipe Gas Pipe Gas Pipe Model name
3-8 Branches UTP-J0908A UTP-J1808A

Total cooling capacity of indoor unit kW 28.0 or less 28.1 to 56.0


Liquid Pipe Liquid Pipe Liquid Pipe

Header Outdoor unit Branch kit


Model name UTP-CX567A (for V-III) UTP-DX567A (for VR-II)
UTR-H0906L / UTR-H1806L UTR-H0908L / UTR-H1808L UTP-J0906A / UTP-J1806A UTP-J0908A / UTP-J1808A
Suction Suction 2 outdoor units 1
Gas Pipe Gas Pipe Model name
Gas Pipe Gas Pipe 3 outdoor units 2

Discharge Discharge
Gas Pipe Gas Pipe
EV Kit
Liquid Pipe Liquid Pipe
Liquid Pipe Liquid Pipe Model name UTR-EV09XB UTR-EV14XB

ASHE004GTAH AGHE004GCAH
ASHE012GCAH AGHE012GCAH
Application Model ASHE007GTAH AGHE007GCAH
ASHE014GCAH AGHE014GCAH
ASHE009GTAH AGHE009GCAH

Outdoor Unit Branch Kit


UTP-CX567A UTP-DX567A
RB Unit
Suction Gas Pipe
Gas Pipe Model name Single type Multi type

Number of Outdoor unit UTP-RX01AH UTP-RX01BH UTP-RX01CH UTP-RX04BH


Discharge Gas Pipe
Power source V/Ø/Hz 230 / 1 / 50

Liquid Pipe Input power W 17 24 31 96


Liquid Pipe
Number of branches 1 1 1 4

Maximum capacity of connectable


kW Q 8.0 Q 18.0 Q 28.0 Q 56.0*1
indoor units(Q)
EV Kit RB Unit Maximum capacity of connectable
kW Q 8.0 Q 18.0 Q 28.0 Q 18.0
indoor units per branch(Q)
Model code 09 : UTR-EV09XB Model code 09 : UTR-EV09XB UTP-RX01AH / UTP-RX01BH / UTP-RX04BH Maximum number of connectable
3 8 8 8
indoor units per branch
Model code 12 : UTR-EV14XB Model code 12 : UTR-EV14XB UTP-RX01CH Multi type
Dimensions (H×W×D) mm 198 × 298 × 268 198 × 298 × 268 198 × 298 × 268 260 × 658 × 428
For Compact Wall Mounted type For Compact Floor type Single type
*1: In case of two RB units connected in series ( total 8-branches ), maximum capacity of connectable indoor units is up to 56.0kW.

148 149

You might also like