dy Chmox surmise. — Centro di taratura Via Matin estema, 18 - 41012 Carpi - Modena - Telefono 059-663006 - Fax 059.663128 Report of Calibration Number 09-RT-246 Number ofpages 3 Date of issue 14.12.2009 Customer MARCHESINIGROUPS.p. Stab di Latina Customer Address Via Beli, 1S = 08100 Latina (LI) Instrument ‘Themometic chains fortwo welding rollers Manufacturer MARCHESINI GROUP S.p.. Model ‘Strip Packaging Machine MST200 Serial number 2080005 Measurements performed on 10-12.2009 Performing site MARCHESINI GROUP S.p.A., Latina (LT) ~ Via Belioe, 15 The measurement results reported in this certificate were obtained following the procedures reported in the following rages (logether with the first line standards which begin the ‘traceability chain and their valid cerifictes of calibration. The measurement uncertaimies stated inthis document are estimated atthe level af twice the standard devietion (corresponding inthe case of normal distribution, to a confidence level of ‘abou 9336 Head ofthe Centre JSR a dy Cuox. urrmmersu. Centro di taratura Via Malini estema, 18 - 41012 Carpi - Modena - Telefono 059-563006 - Fax 059-663128 Report of calibeation Nr 09:R7-246 ‘The measurement results reported inthis report were obtained following the procedutes ofthe Centre NR, PTO1, PTOZE. "he traceability chain to international standards begins from the fist line standard and theit valid eertticates of calibration Platinum Resistance thermometer ROSEMOUNT 162CE id. n, TRISISR, certificate N. 08- 1173.01 UNRIM), ‘multimeter HP 34584 id. n, EMIOO1, certificate 09-2081173480-1 (SIT-05 Agilent) ration pre Laborator i em Scope of this testis to calibrate the instruments in item by comparison with a reference Standard: citer the probes under fest and the reference standard were patted into the well of Portable calibration furnace, mod, MT-l, sn. 11-00-005, at a depth. of 150mm, ‘A precise temperature meter, mod. ISO-CAL 9000+, THERMO ELECTRIC: sin, 23787, was ‘sed in conjunction with a ype PL100 RTD probe , sn, TR74 the chain was SIT cenfied (certificate n. 09-81-2231 issied on 23.11.2009) Calibration was caried out in the range + 15°C around the mean working temperature indicated by Marchesini Grcup SpA. 3 tempersture points was selected and measured from the lower othe higher ones ‘Uncertainty in the temperature measurement ‘The expanded value of uncertainty (2 sigma) is determined by evaluating, the uncertainty contributions ofall the paraneters affecting the measurement: it comprises the uncertainty

You might also like