Professional Documents
Culture Documents
Efficiency and comfort for your customers. YORK® VRF systems are modular and
controlled solutions that include models with
New growth opportunities for your business. capability to simultaneously heat and cool
different zones.
Building climate control is about comfort and efficiency – delivering The technology brings an array of advantages over conventional
just the right heating and cooling to every space using no more systems.
energy than necessary. YORK® variable refrigerant flow (VRF)
•S
ave on energy. Systems essentially eliminate duct losses. In
technology lets you do that for customers in innovative ways that
addition, variable-speed compressors in outdoor units provide
present new growth opportunities for your business.
extremely high part-load efficiency.
VRF technology gives building owners, architects, consulting •K
eep people comfortable. Users can set individual temperature
engineers, and mechanical contractors an innovative solution to set points for multiple zones. Variable-speed compressors with
address the common challenge of reducing operating costs in wide capacity and precise modulation help maintain each zone’s
buildings with varied loads and occupancy rates while delivering temperature within a narrow range. Indoor units also operate
comfort to all areas. The systems can offer: quietly.
• Exceptional efficiency, delivering an average of up to 39% energy • Go green. VRF technology can help users attain LEED® certification
savings for some applications compared to conventional HVAC points for resource efficiency.
systems.
Enjoy design freedom
• Flexibility to specify a customized modular system to the
A variety of standard modular components let you customize
exacting requirements of each project, with options that include
and size equipment to meet specific project requirements.
heat pump and a host of fan coil options.
Because ductwork is generally needed only for ventilation, ducts
• Freedom for designers to choose ducted systems with short can be smaller, reducing capital cost. Systems can easily be adapted
or long runs, or ductless systems that allow for much lower as space is reconfigured. Unlike conventional HVAC systems, VRF
clearance between building floors and therefore lower overall systems allow addition of capacity to accommodate expansion simply
construction costs. by adding modular units (capacities 8-54 HP). There is no need to
remove and replace the original unit or reconfigure ductwork.
• Impressively quiet comfort, with control to deliver precisely the
correct amount of heating or cooling to each zone. Install with ease
YORK® VRF systems are designed for quick and simple
installation, since piping from the outdoor units can be connected
from the front, back, or underneath. Indoor units are relatively small
and light and easy to transport and handle; outdoor units can be
brought into a building for installation on a rooftop via a service
elevator – no crane or other heavy equipment is needed. Service is
simple, too: Systems need little maintenance beyond changing filters
and cleaning coils. Removal of a single panel provides easy access to
The information contained in this catalog is for illustration purposes only and is all components: control boards, electrical connections, compressor
subject to change at the sole discretion of Johnson Controls. Statements, figures, and piping.
calculations, plans, images and representations are only examples. Johnson Controls
encourages you, as the purchaser, to analyze your HVAC requirements and to work
with Johnson Controls to determine the exact VRF System to fulfill your needs.
1 2
Get expert advice at every step: select, design, specify, install
Gain flexibility control Your Johnson Controls account team supports you as no one
else can, at every step of every project. Effective training, intuitive
Users can choose from three basic control options.
design and specification software, advanced logistics and delivery,
• Indoor fan coil units come with a selection of thermostats using
and easily accessible documentation form a powerful support
wired remote control, from simple units with on/off, setpoint, load
package that adds substantial value to YORK® VRF systems.
and speed settings, to programmable units that enable scheduling.
Wireless units are available to provide remote control of zone space Get your team up to speed fast.
conditions. Efficient performance, quality installations.
•C
entral station controllers for larger projects provide remote
Comprehensive training programs provide knowledge and
control and scheduling of the entire system from one or more
skills necessary to effectively and efficiently use YORK® VRF
control points.
technology. Our world-class VRF training center offers a multitude
• Adapters (gateways) enable control of large buildings or campuses of classes with specialized modules and topics that help:
through building automation systems such as Metasys®.
• Salespeople submit competitive bids and close deals.
Choose multiple applications • D
esigners select and configure the right equipment easily
YORK VRF systems suit a wide range of buildings in new
® and accurately.
construction and retrofits. Prime candidates include:
• Installers learn the proper procedures and complete jobs
• Buildings with multiple zones that have different comfort needs – accurately, on time and on budget.
such as hotels, schools, medical office buildings, commercial office
• S
ervice technicians maintain, troubleshoot and repair systems
buildings and others.
efficiently.
• Historical building renovations in which ducted HVAC options
are severely limited and the basic building structure must not be The training center includes a dedicated VRF laboratory
disturbed. to provide hands-on experience with the various systems,
components and controls. Videos and webinars supplement
• Buildings in climate zones favorable for heat pump technology.
classroom learning on specific subjects and refresh and enhance the
skills of your sales, design, installation, and service teams. YORK®
VRF training programs help deliver peace of mind that your staff is
prepared to support your business with the knowledge to compete in
a growing industry.
3 4
Get the tools that give you an edge
Consistent delivery:
Get the right equipment to the jobsite on time
PC-based program Let’s explore the many advantages of VRF systems together so you
can put them to work for your customers. On these pages, you can
The PC-based program gives you mobility and flexibility. The explore detailed information on the full range of YORK® VRF systems.
software helps you:
• Design accurate final system drawings including piping and wiring
diagrams in an easy, quick, step-by-step process.
• Accurately select systems using a System Sizing Analysis. The
process starts with the indoor fan coil units, so that outdoor units
are optimally sized. Proprietary algorithms figure the system size
using data input on the indoor units, load, and measurements, so
your system does not include capacity that will go unutilized.
• Use intuitively designed features and functionality that make the
design process easy, fast, and accurate. You can select options
and accessories without referring to additional information or
performing additional calculations.
• Gain an edge by confidently designing VRF systems that are right-
sized, and include the right equipment for each project.
5 6
Introducing a new addition to York’s VRF
range of VRF air conditioning units - enhancing Capable of Heat Recovery and 2-pipe Heat Pump Operations
efficiency and user experience York’s outdoor units feature a heat recovery operation system as well as a 2-pipe heat pump
operation system. This avoids the need for review work when designing the equipment layout,
while reducing the workload and time spent installing the units on site.
There is increasing demand for a holistic approach to air conditioning in modern offices - units
that are capable of simultaneously cooling and heating, adapting to the different seasons and
various temperature requirements of rooms. 3-pipes Heat recovery and 2-pipe heat pump
2-pipes
operations common unit
Customers also want to save time, money and space with their air conditioning and CH units
And of course there is a growing demand for air conditioning to be as environmentally friendly
The heat recovery and 2-pipe heat pump operation systems cannot be switched over after installation is complete.
as possible - enabled through an air-conditioning management system that makes it easier for
users to have simple, effective control of their air conditioning units to avoid unnecessary energy
wastage, including overheating, overcooling and unattended operation.
To meet and exceed these important requirements,
York has developed the YORK High Efficiency VRF air conditioning system.
York air conditioning successfully meets installer and
customer demands - offering greater functionality,
control and cost savings
7 8
Heat Recovery Operation
Heat Recovery Operation Significantly Enhances Energy-saving Efficiency System Configuration
A heat recovery system offers high energy-saving efficiency by drawing heat from the rooms to be cooled, Outdoor Unit Refrigerant Piping Transmission
and effectively using it as a heat source for the rooms to be heated. Heat recovery and 2-pipe heat pump operations common unit Max. length: 165m Corresponding to H-LINK
Module type (external connection) Total length: 1,000m Max. 64 refrigerant groups
Max. 160 indoor units
heat release
heat release
heat absorption
heat absorption
Cooling with Heating with
50% capacity 50% capacity
10HP
heat release
heat release
CH Unit (heat recovery system only)
Changeover box for heat recovery application
heat absorption Compact and light design
Minimized unit and less suspension bolts facilitate installation
heat absorption
and handling methods.
Specifications Indoor Unit Connection
9 10
Product Line-up Energy-saving and Comfort
Choose the best suited model from a selection of each base unit used individually or in combinations. New Type DC Inverter Scroll Compressor
Discharge Pressure Space
All integrating heat recovery and heat pump operation suit the customer requirements.
Improved Intermediate Pressure Performance Valve Open
Pressure
Control Valve
The intermediate pressure performance is drastically improved by using a release valve (Release Valve)
Outdoor Unit and optimizing orbiting scroll lifting force in the improved new compression mechanism. Hole for Release Valve
Base Unit (3models) Release valve adoption prevents over compression. Space
Fixed Scroll
Orbiting scroll lifting force optimization has achieved leakage loss reduction. Pressure at
Discharge Pressure
Compression Space
JUOD series is all inverter models.
Refer to "GENERAL DATA" for information on the combination of base units. Capacity Control by 1 Hz Wide Working Range
Performance is greatly improved by the high efficiency DC JUOD Series can handle a wide range of outside air
inverter compressor and conditions, thus extending the flexibility of installation space
(HP) 100%
loss-less energy saving 12 HP and climatic environment.
Two-Way Cassette
Slim Ducted
Power Consumption
energy-saving effects. Since the current is self-detected and
demand control is performed automatically, no signal wiring
Medium Static Ducted
work is required. Conventional demand control using demand Maximum efficiency is secured within the
power setting range.
signals is also available, and you can select various operations NEW
High Static Ducted
as required. Morning Daytime Night
Operation Hours
Ceiling Suspended
High Wall
11 12
Flexibility of Installation
1,720mm
2 Between first branch
and indoor unit
90m or less *2
90m or less *2
3
Height difference between
3
highest and lowest indoor units
30m or less 15m or less
Height difference between
50m* 50m*
4 3 3
2
outdoor and indoor units 1
*2*4
765mm
Sales on order 90m or less
1,210mm Max. length between branch
5
from indoor units
40m 40m
NOTES
Basic Unit Can Be Carried in an Elevator *1: For 100m or more, the pipe diameter will be one size larger.
*2: There’re restrictions for connectable indoor units and refrigerant amount.
Elevator Please refer to technical manual for details.
Door Opening: 800 mm *3: In case the outdoor unit is installed at a higher level than indoor units.
If the outdoor unit is installed lower than indoor units, the maximum height difference is 40m.
Depth: 1350 mm *4: In case the outdoor unit is installed at a higher level than indoor units, and only when it is a base unit.
Improvement of Workability
The piping connection work is newly available from the refrigerant piping outlet Connectable to 59 Indoor Units Max.
(right bottom side of the front cover) in addition to three directions (front, rear or bottom) from the bottom base.
The number of connectable indoor units has been increased to 59 maximum.
Thus, the system can be used in buildings where there are many indoor units to be connected.
Newly Added
NOTES
Front Cover *: For a system in which all indoor units are operated simultaneously, the max. total capacity will be 100%.
Determine the number of Indoor Units carefully so that a problem such as decreased outlet air temperature will not occur.
Refrigerant Piping Outlet Refer to Technical Catalog for more details.
*: Make
Compared to indoor units of over 4.3kW, indoor units of 1.6 to 2.8kW are set with higher air flow.
sure to select appropriate indoor units when installing indoor units where cold draft may occur during heating operation.
A new piping outlet is provided on the lower right side of the front cover and so the piping Determine the usage environment and installation location carefully.
connection kit can be installed at the lower position.
This makes an easy and clear installation of the piping from multiple outdoor units possible.
13 14
Other Advanced Technologies
Rotational Operation*1 to Distribute Load of Outdoor Units Noise Reduction Preference Mode (Optional Function)
Regulating the operation time of each outdoor unit leads to load reduction on compressors.*2 With the new Noise Reduction Preference Mode, the sound pressure level for a particular time zone can be set based upon
During multiple unit operation, the same rotation frequency of inverter compressor results in the usage environment. *1 Therefore, the operation/management of air conditioners is facilitated in areas where the noise
an equivalent load on each compressor. Therefore, outdoor unit endurance is improved. level at night time is restricted by laws and regulations.
Inverter Compressor Rotation Frequency Control (Example) Last Time You can select from 3 sound pressure levels
*: Perform the electrical wiring work on site when setting input signal.
x
Failed Outdoor Unit
NOTES
*1: At least 2 outdoor units are required for this function.
*2: Emergency operation can be performed within 8 hours after unit stoppage.
After 8 hours pass from unit stoppage, emergency operation can not be Emergency Operation Indication
Press " TEMP. "
performed.
simultaneously
*3: Emergency operation can be performed when the specified alarm code
occurs. Refer to “Alarm Code for Emergency Operation”. for 3 seconds.
15 16
HIGH U PTO
Power Supply 3N~ , 380-415V/50Hz 35℃ Power Input kW 19.90 17.96 20.36 22.72 24.49 26.86 28.63
(Nominal) (Btu/h)/W 11.85 11.90 13.35 12.75 12.60 12.05 11.95
kW 22.4 28.0 33.5 45.0 50.0 56.0 61.5 EER
Capacity kW/kW 3.47 4.06 3.93 3.74 3.67 3.54 3.49
Cooling (1) Btu/h 76,000 96,000 114,000 154,000 170,000 192,000 210,000
kW 53.6 63.2 67.2 69.8 73.8 76.4 80.4
35℃ Power Input kW 5.12 7.66 9.60 10.30 12.67 14.75 17.26 Capacity
Btu/h 182,000 216,000 230,000 238,000 252,000 260,000 274,000
(Nominal) Cooling (2)
(Btu/h)/W 14.85 12.55 11.90 14.95 13.40 13.00 12.15 Power Input kW 19.62 22.50 23.53 25.45 26.48 28.40 29.43
EER(2) 46℃
kW/kW 4.38 3.66 3.49 4.37 3.95 3.80 3.56 (Btu/h)/W 9.30 9.60 9.75 9.35 9.50 9.15 9.30
EER
kW 20.2 22.8 26.8 40.4 43.0 47.0 49.6 kW/kW 2.73 2.81 2.86 2.74 2.79 2.69 2.73
Capacity
kW 42.8 54.4 55.8 58.6 60.0 62.8 64.2
Btu/h 69,000 78,000 91,000 138,000 146,000 160,000 170,000 Capacity
Cooling (2) Btu/h 146,000 186,000 190,000 200,000 204,000 214,000 220,000
Power Input kW 6.86 8.78 9.81 13.72 15.64 16.67 18.59 Cooling (3)
46℃ Power Input kW 13.52 18.90 18.30 19.89 19.29 20.88 20.28
(Btu/h)/W 10.05 8.90 9.30 10.05 9.35 9.60 9.15 48℃
EER(2) (Btu/h)/W 10.80 9.85 10.40 10.05 10.60 10.25 10.85
EER
kW/kW 2.94 2.60 2.73 2.94 2.75 2.82 2.67 kW/kW 3.17 2.88 3.05 2.95 3.11 3.01 3.17
kW 17.2 20.0 21.4 34.4 37.2 38.6 41.4 kW 77.5 82.5 90.0 95.0 100.0 106.0 112.0
Capacity Capacity
Btu/h 58,500 68,000 73,000 117,000 127,000 132,000 142,000 Btu/h 264,000 282,000 308,000 324,000 342,000 362,000 382,000
Heating
Cooling (3) Power Input kW 18.96 17.72 20.50 21.49 23.60 24.84 27.24
Power Input kW 5.77 7.36 6.76 11.54 13.13 12.53 14.12 (Nominal)(4)
48℃
(Btu/h)/W 13.90 15.90 15.00 15.10 14.50 14.55 14.00
(Btu/h)/W 10.15 9.25 10.80 10.15 9.65 10.55 10.05 COP
EER(2) kW/kW 4.09 4.66 4.39 4.42 4.24 4.27 4.11
kW/kW 2.98 2.72 3.17 2.98 2.83 3.08 2.93
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
kW 25.0 31.5 37.5 50.0 56.0 63.0 69.0 Maximum
Sound Pressure Level
Capacity
Btu/h 85,000 107,000 128,000 170,000 192,000 214,000 236,000 [Overall A Scale] (Night-Shift) dB 64(59) 64(59) 64(59) 65(60) 65(60) 66(61) 66(61)
Heating
Power Input kW 5.36 6.74 9.12 10.71 11.97 14.61 15.86 Outer Dimension H×W×D mm 1,720 x 2,440 x 765 1,720 x 3,670x 765
(Nominal)(4)
(Btu/h)/W 15.85 15.90 14.05 15.85 16.05 14.65 14.90 Net Weight kg 260+260 260+260+260
COP Gross Weight kg 275+275 275+275+275
kW/kW 4.66 4.67 4.11 4.67 4.68 4.31 4.35
Refrigerant - R410A
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
Compressor Quantity - 1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1
Sound Pressure Level Maximum (Scroll) Motor Output (Pole) kW 7.2(6)+7.2(6) 4.8(6)+4.8(6)+6.0(6) 4.8(6)+4.8(6)+7.2(6) 4.8(6)+6.0(6)+7.2(6) 4.8(6)+7.2(6)+7.2(6) 6.0(6)+7.2(6)+7.2(6) 7.2(6)+7.2(6)+7.2(6)
[Overall A Scale] (Night-Shift) dB 58(53) 59(54) 61(56) 61(56) 62(57) 63(58) 64(59) Quantity - 2 3 3 3 3 3 3
Condenser Fan
Outer Dimension H×W×D mm 1,720 x 1,210 x 765 1,720 x 2,440 x 765 Air Flow Rate m2/min 195+195 160+160+175 160+160+195 160+175+195 160+195+195 175+195+195 195+195+195
(Propeller Fan)
Net Weight kg 260 260+260 Motor Output (Pole) kW 0.66(8)+0.66(8) 0.40(8)+0.40(8)+0.52(8) 0.40(8)+0.40(8)+0.66(8) 0.40(8)+0.52(8)+0.66(8) 0.40(8)+0.66(8)+0.66(8) 0.52(8)+0.66(8)+0.66(8) 0.66(8)+0.66(8)+0.66(8)
Main Refrigerant Piping
Gross Weight kg 275 275+275
Heat Pump System (2 Piping)
Refrigerant - R410A Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Compressor Quantity - 1 1 1 1+1 1+1 1+1 1+1 Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
17 18
HIGH U PTO
Power Supply 3N~ , 380V/60Hz 35℃ Power Input kW 19.90 17.96 20.36 22.72 24.49 26.86 28.63
(Nominal) (Btu/h)/W 11.85 11.90 13.35 12.75 12.60 12.05 11.95
kW 22.4 28.0 33.5 45.0 50.0 56.0 61.5 EER(2)
Capacity kW/kW 3.47 4.06 3.93 3.74 3.67 3.54 3.49
Cooling (1) Btu/h 76,000 96,000 114,000 154,000 170,000 192,000 210,000
kW 53.6 63.2 67.2 69.8 73.8 76.4 80.4
35℃ Power Input kW 5.12 7.66 9.60 10.30 12.67 14.75 17.26 Capacity
Btu/h 182,000 216,000 230,000 238,000 252,000 260,000 274,000
(Nominal) Cooling (2)
(Btu/h)/W 14.85 12.55 11.90 14.95 13.40 13.00 12.15 Power Input kW 19.62 22.50 23.53 25.45 26.48 28.40 29.43
EER 46℃
kW/kW 4.38 3.66 3.49 4.37 3.95 3.80 3.56 (Btu/h)/W 9.30 9.60 9.75 9.35 9.50 9.15 9.30
EER(2)
kW 20.2 22.8 26.8 40.4 43.0 47.0 49.6 kW/kW 2.73 2.81 2.86 2.74 2.79 2.69 2.73
Capacity
kW 42.8 54.4 55.8 58.6 60.0 62.8 64.2
Btu/h 69,000 78,000 91,000 138,000 146,000 160,000 170,000 Capacity
Cooling (2) Btu/h 146,000 186,000 190,000 200,000 204,000 214,000 220,000
Power Input kW 6.86 8.78 9.81 13.72 15.64 16.67 18.59 Cooling (3)
46℃ Power Input kW 13.52 18.90 18.30 19.89 19.29 20.88 20.28
(Btu/h)/W 10.05 8.90 9.30 10.05 9.35 9.60 9.15 48℃
EER (Btu/h)/W 10.80 9.85 10.40 10.05 10.60 10.25 10.85
EER(2)
kW/kW 2.94 2.60 2.73 2.94 2.75 2.82 2.67 kW/kW 3.17 2.88 3.05 2.95 3.11 3.01 3.17
kW 17.2 20.0 21.4 34.4 37.2 38.6 41.4 kW 77.5 82.5 90.0 95.0 100.0 106.0 112.0
Capacity Capacity
Btu/h 58,500 68,000 73,000 117,000 127,000 132,000 142,000 Btu/h 264,000 282,000 308,000 324,000 342,000 362,000 382,000
Heating
Cooling (3) Power Input kW 18.96 17.72 20.50 21.49 23.60 24.84 27.24
Power Input kW 5.77 7.36 6.76 11.54 13.13 12.53 14.12 (Nominal)(4)
48℃
(Btu/h)/W 13.90 15.90 15.00 15.10 14.50 14.55 14.00
(Btu/h)/W 10.15 9.25 10.80 10.15 9.65 10.55 10.05 COP
EER kW/kW 4.09 4.66 4.39 4.42 4.24 4.27 4.11
kW/kW 2.98 2.72 3.17 2.98 2.83 3.08 2.93
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
kW 25.0 31.5 37.5 50.0 56.0 63.0 69.0 Maximum
Sound Pressure Level
Capacity
Btu/h 85,000 107,000 128,000 170,000 192,000 214,000 236,000 [Overall A Scale] (Night-Shift) dB 64(59) 64(59) 64(59) 65(60) 65(60) 66(61) 66(61)
Heating
Power Input kW 5.36 6.74 9.12 10.71 11.97 14.61 15.86 Outer Dimension H×W×D mm 1,720 x 2,440 x 765 1,720 x 3,670 x 765
(Nominal)(4)
(Btu/h)/W 15.85 15.90 14.05 15.85 16.05 14.65 14.90 Net Weight kg 260+260 260+260+260
COP Gross Weight kg 275+275 275+275+275
kW/kW 4.66 4.67 4.11 4.67 4.68 4.31 4.35
Refrigerant - R410A
Cabinet Color (Munsell Code) - Natural Gray (1.0Y 8.5/0.5)
Compressor Quantity - 1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1 1+1+1
Sound Pressure Level Maximum (Scroll) Motor Output (Pole) kW 7.2(6)+7.2(6) 4.8(6)+4.8(6)+6.0(6) 4.8(6)+4.8(6)+7.2(6) 4.8(6)+6.0(6)+7.2(6) 4.8(6)+7.2(6)+7.2(6) 6.0(6)+7.2(6)+7.2(6) 7.2(6)+7.2(6)+7.2(6)
[Overall A Scale] (Night-Shift) dB 58(53) 59(54) 61(56) 61(56) 62(57) 63(58) 64(59) Quantity - 2 3 3 3 3 3 3
Condenser Fan
Outer Dimension H×W×D mm 1,720 x 1,210 x 765 1,720 x 2,440 x 765 Air Flow Rate m2/min 195+195 160+160+175 160+160+195 160+175+195 160+195+195 175+195+195 195+195+195
(Propeller Fan)
Net Weight kg 260 260+260 Motor Output (Pole) kW 0.66(8)+0.66(8) 0.40(8)+0.40(8)+0.52(8) 0.40(8)+0.40(8)+0.66(8) 0.40(8)+0.52(8)+0.66(8) 0.40(8)+0.66(8)+0.66(8) 0.52(8)+0.66(8)+0.66(8) 0.66(8)+0.66(8)+0.66(8)
Main Refrigerant Piping
Gross Weight kg 275 275+275
Heat Pump System (2 Piping)
Refrigerant - R410A Liquid Line mm[in.] φ15.88[5/8] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4] φ19.05[3/4]
Compressor Quantity - 1 1 1 1+1 1+1 1+1 1+1 Gas Line Low Pressure mm[in.] φ28.58[1-1/8] φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ31.75[1-1/4]* φ38.1[1-1/2]*
19 20
Indoor Units Indoor Units
576
3.2m
530
New developed high efficiency turbo-fan is adopted. By improving
570
grid ceiling with a 600mm x 600mm
Motion Sensor Control (Option) 3D twisted blade of turbo-fan and air outlet, the fan efficiency is
opening without cutting the grid.
0.8m improved and the low noise performance is achieved. 576
The air conditioning capacity is saved automatically depending on a (From Floor Surface)
Grid Ceiling (mm)
NEW CURRENT
situation and detecting amount of human activity by adopting the In the case of the ceiling height is 3.2m. Indoor Unit Capacity (HP) Highly Compact Size
0.6 0.8 1.0 1.5 2.0 2.5 0.6 0.8 1.0 1.5 2.0 2.5
motion sensor on the corner of the air panel. The energy saving can Compared with the standard Four-Way Cassette Type indoor unit,
be improved more with the individual operating function. In Adopting New Structured Silky Flow Louver Sound Pressure Level (dBA)
24.5 24.5 24.5 27.5 31 35 28 28 28 33 37 N/A the size of the air panel for this product has been reduced by
Air Flow Volume LOW
addition, the operation can be stopped automatically if the absent 75mm
The newly-structured silky flow 330mm (from 950mm to 620mm). 620mm
situation continues for more than 30 minutes*1. The motion sensor
louver is adopted to soften the
can maintain the comfortable indoor environment and eliminating
discomfort by the temperature Light-weight Unit
the unnecessary operation*2. 620mm
irregularity and the cold draft.
*1): The default setting is “30 minutes”. However, the setting is changeable. Compared with the standard Four-Way Cassette Type indoor unit, the
The individual control setting 570mm
*2): The default setting is “Running Operation”. However, “Automatic Stop” can be selected by setting weight of this product has been reduced by 4kg (from 21kg to 17kg).
*3): The detecting area becomes smaller if the people stay motion less is few such as stretching on a chair, etc. for each louver is available. New Silky Flow Louver
This makes the transportation and installation much easier. 285mm
Specifications The dashed line shows the size of the standard Four-way cassette type.
Model JTKF028H0PS0AS JTKF040H0PS0AS JTKF056H0PS0AS JTKF071H0PS0AS JTKF080H0PS0AS JTKF112H0PS0AS JTKF140H0PS0AS JTKF160H0PS0AS Specifications
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz Model JTKM016H0PS0AS JTKM022H0PS0AS JTKM028H0PS0AS JTKM040H0PS0AS JTKM056H0PS0AS JTKM071H0PS0AS
kW 2.9 4.1 5.8 7.3 8.3 11.6 14.5 16.5 Indoor Unit Power Supply
Nominal Cooling 1N~, 220-240V / 50Hz, 220V / 60Hz
kcal/h 2,500 3,550 5,000 6,300 7,100 10,000 12,500 14,200
Capacity *1) 9,900 14,100
kW 1.7 2.3 2.9 4.1 5.8 7.3
Btu/h 19,800 25,000 28,200 39,700 49,600 56,300 Nominal Cooling
kcal/h 1,500 2,000 2,500 3,550 5,000 6,300
Capacity *1)
kW 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0 Btu/h 5,800 7,900 9,900 14,100 19,800 25,000
Nominal Cooling kcal/h 2,400 3,400 4,800 6,100 6,900 9,600 12,000 13,800
Capacity *2) kW 1.6 2.2 2.8 4.0 5.6 7.1
Btu/h 9,600 13,600 19,100 24,200 27,300 38,200 47,800 54,600 Nominal Cooling
kcal/h 1,400 1,900 2,400 3,400 4,800 6,100
3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0 Capacity *2)
kW Btu/h 5,500 7,500 9,600 13,600 19,100 24,200
Nominal Heating
kcal/h 2,800 4,100 5,400 7,300 7,700 10,700 13,800 15,500
Capacity kW 1.9 2.5 3.2 4.8 6.3 8.5
Btu/h 10,900 16,400 21,500 29,000 30,700 42,600 54,600 61,400 Nominal Heating kcal/h 1,700 2,100 2,800 4,100 5,400 7,300
Sound Pressure Level Capacity 6,500 8,500 10,900 16,400 21,500 29,000
dB 33/30/28/27 35/31/30/27 37/32/30/27 42/36/32/28 42/36/32/28 48/43/39/33 48/45/40/35 48/46/41/37 Btu/h
(Overall A Scale) Hi2/Hi/Me/Lo
Sound Pressure Level
Dimensions H x W x D mm 248 x 840 x 840 298 x 840 x 840 (Overall A Scale) Hi2/Hi/Me/Lo
dB 34/30/28/24.5 36/33/29/24.5 38/34/30/24.5 41/37/33/27.5 45/39/35/31 47/43/39/35
Net Weight kg 20 21 22 26 Dimensions H x W x D mm 285 x 570 x 570
Refrigerant R410A (Nitrogen-charged for Corrosion-resistance) kg
Net Weight 16 17
Air Flow Rate m3/min. 15/13/11/9 21/17/14/11 21/17/14/11 27/23/18/14 27/23/18/14 37/31/24/20 37/33/26/21 37/35/28/22 Refrigerant R410A (Nitrogen-charged for Corrosion-resistance)
Hi2/Hi/Me/Lo (cfm) (530/459/388/318) (741/600/494/388) (777/600/494/388) (953/812/635/494) (953/812/635/494) (1,306/1,094/847/706) (1,306/1,165/918/741) (1,306/1,236/988/777)
Air Flow Rate 10/8.5/7.5/6 11/9.5/8/6 12/10/8.5/6 13/11/9.5/7 15/12/10/8 16/14/12/10
Motor W 57 127 Hi2/Hi/Me/Lo m3/min.(cfm) (353/300/265/212) (388/335/282/212) (424/353/300/212) (459/388/335/247) (530/424/353/282) (565/494/424/353)
Connections Flare-Nut Connection (With Flare Nuts)
Motor W 57
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88
Connections Flare-Nut Connection (With Flare Nuts)
Condensate Drain VP25 Liquid / Gas mm φ6.35 /φ12.7 φ9.52 /φ15.88
Approximate
m3 0.21 0.25 Condensate Drain VP25
Packing Measurement
Approximate Packing Measurement m3 0.13
Adaptable Panel Model JP-AP160NA1 (without Motion Sensor) / JP-AP160NAE (with Motion Sensor)
Adaptable Panel Model JP-AP56NAM
Color Natural White
Color Neutral White
Dimensions H x W x D mm 37 x 950 x 950
Dimensions H x W x D mm 30 x 620 x 620
Net Weight kg 6.5
Net Weight kg 2.5
Approximate
m3 0.10 Approximate Packing Measurement m3 0.04
Packing Measurement
NOTES:
NOTES: 1. The nominal cooling and heating capacity is based on the JIS standard B8616.
1. The nominal cooling and heating capacity is based on the JIS standard B8616. Cooling Operation Conditions Heating Operation Conditions
Cooling Operation Conditions Heating Operation Conditions Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB) *1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB) *2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB) Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter 2. The sound pressure level is based on following conditions.
2. The sound pressure level is based on following conditions. 1.5 Meters Beneath the Unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
1.5 Meters Beneath the Unit. The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
21 22
Indoor Units Indoor Units
270mm 250mm
False Ceiling
(2.2-7.1kW) Slimmer
900mm 650mm
Specifications Specifications
Model JTKT022H0PS0AS JTKT028H0PS0AS JTKT040H0PS0AS JTKT056H0PS0AS JTKT071H0PS0AS JTKT080H0PS0AS JTKT112H0PS0AS JTKT140H0PS0AS JTKT160H0PS0AS Model JTDM022H0PS0AS JTDM028H0PS0AS JTDM040H0PS0AS JTDM056H0NS0AS JTDM071H0NS0AS JTDH080H0NS0AS JTDH112H0NS0AS JTDH140H0NS0AS
Indoor Unit Power Supply 1N~, 220-240V / 50Hz, 220V / 60Hz
Indoor Unit Power Supply 1N, 220-240V / 50Hz, 220V / 60Hz
kW 2.3 2.9 4.1 5.8 7.3 8.3 11.6 14.5 16.5
Nominal Cooling kcal/h 2,000 2,500 3,550 5,000 6,300 7,100 10,000 12,500 14,200 kW 2.3 2.9 4.1 5.8 7.3 8.3 11.6 14.5
Capacity *1) Nominal Cooling
Btu/h 7,900 9,900 14,100 19,800 25,000 28,200 39,700 49,600 56,300 kcal/h 2,000 2,500 3,550 5,000 6,300 7,100 10,000 12,500
Capacity *1)
Btu/h 7,900 9,900 14,100 19,800 25,000 28,200 39,700 49,600
kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0 16.0
Nominal Cooling kcal/h 1,900 2,400 3,400 4,800 6,100 6,900 9,600 12,000 13,800 kW 2.2 2.8 4.0 5.6 7.1 8.0 11.2 14.0
Nominal Cooling
Capacity *2) 7,500 9,600 13,600 19,100 24,200 27,300 38,200 47,800 54,600 kcal/h 1,900 2,400 3,400 4,800 6,100 6,900 9,600 12,000
Btu/h Capacity *2)
Btu/h 7,500 9,600 13,600 19,100 24,200 27,300 38,200 47,800
kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0 18.0
Nominal Heating kW 2.5 3.2 4.8 6.3 8.5 9.0 12.5 16.0
kcal/h 2,100 2,800 4,100 5,400 7,300 7,700 10,700 13,800 15,500 Nominal Heating
Capacity kcal/h 2,100 2,800 4,100 5,400 7,300 7,700 10,700 13,800
Btu/h 8,500 10,900 16,400 21,500 29,000 30,700 42,600 54,600 61,400 Capacity
Btu/h 8,500 10,900 16,400 21,500 29,000 30,700 42,600 54,600
Sound Pressure Level Sound Pressure Level
(Overall A Scale) Hi2/Hi/Me/Lo
dB 30/29/28/27 31/29/28/27 37/34/31/30 39/36/33/30 42/39/36/33 45/42/38/33 43/40/37/34 47/44/41/35 48/45/42/39 dB 35/33/31 36/34/32 42/39/35 43/40/36 44/41/37
(Overall A Scale) Hi/Me/Lo
Dimensions H x W x D mm 298 x 860 x 630 298 x 1,420 x 630 Dimensions 270 x (650+75) 270 x (900+75) 350 x (650+75) 350 x (900+75) 350 x (1,300+75)
mm
Net Weight kg 23 25 39 HxWxD x 720 x 720 x 800 x 800 x 800
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance) Net Weight kg 26 35 37 46 58
Air Flow Rate m3/min. 10/9/7.5/6.5 11/9.5/8.5/7 15/13/11.5/10 16.5/14.5/12.5/10.5 18.5/16.5/14.5/12.5 21/18.5/16/12.5 30/26.5/23/20 35/31/27/21 37/32.5/28.5/24 Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Hi2/Hi/Me/Lo (cfm) (353/318/265/230) (388/335/300/247) (530/459/406/353) (583/512/441/371) (653/583/512/441) (742/653/565/441) (1,059/936/812/706) (1,236/1,095/953/742) (1,306/1,148/1,006/847) Air Flow Rate m3/min. 8/7/6 13/11/9 15/13/11 16/14/12 19/17/14 27/23/19 37/31/25
Hi/Me/Lo (cfm) (283/247/212) (459/388/318) (530/459/388) (565/494/424) (671/600/494) (954/812/671) (1,306/1,095/883)
Motor W 57 57 x 2
Flare-Nut Connection (With Flare Nuts) External Pressure 50 (80-30)*3) 120 (170-60)*3)
Connections
Motor W 60 75 150 290
Liquid / Gas mm φ6.35 /φ12.7 φ9.52 /φ15.88
Condensate Drain Connections Flare-Nut Connection (With Flare Nuts)
VP25
Liquid mm φ6.35 φ6.35 φ9.52 φ9.52
Approximate
m3 0.24 0.36 Gas mm φ12.7 φ15.88 φ15.88 φ15.88
Packing Measurement
Condensate Drain VP25
Adaptable Panel Model JP-AP90DNA JP-AP160DNA Approximate
Color m3 0.21 0.27 0.29 0.38 0.52
Neutral White Packing Measurement
Dimensions H x W x D mm 30 x 1,100 x 710 30 x 1,660 x 710
NOTES:
Net Weight kg 7.5 10.5 1. The nominal cooling and heating capacity is based on the JIS standard B8616.
Approximate Cooling Operation Conditions Heating Operation Conditions
Packing Measurement m3 0.13 0.20 Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
NOTES: *2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
1. The nominal cooling and heating capacity is based on the JIS standard B8616. Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
Cooling Operation Conditions Heating Operation Conditions 2. The sound pressure level is based on following conditions. 1.5 Meter Beneath the Unit. With Discharge Duct (2.0m) and Return Duct (1.0m).
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB) Voltage of the power source for the indoor fan motor is 220V. In case of the power source of 240V, the sound pressure level increases by about 1 or 2dB.
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB) The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB) 3. The data for external pressure *3) indicates "Standard Pressure Setting ( High Pressure Setting - Low Pressure Setting )" values when a filter is not used. Please consider pressure deduction
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter 10Pa in case of York filter accessory used on the unit.
2. The sound pressure level is based on following conditions.
1.5 Meters Beneath the Unit.
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
23 24
Model JTDL084H0NP0AQ JTDL090H0NP0AQ JTDL112H0NP0AQ JTDL142H0NP0AQ JTDL160H0NP0AQ
Indoor Fan
Minimum 5mm Air Flow Rate m3/min. 25/21/17 25/21/17 27/23/19 37/31/25 38/35/29
(Hi/Me/Lo)
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53
Specifications
Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Model JTDL022H0NP0AQ JTDL028H0NP0AQ JTDL036H0NP0AQ JTDL043H0NP0AQ JTDL050H0NP0AQ JTDL056H0NP0AQ JTDL063H0NP0AQ JTDL071H0NP0AQ
Model JTDL022H0NB0AQ JTDL028H0NB0AQ JTDL036H0NB0AQ JTDL043H0NB0AQ JTDL050H0NB0AQ JTDL056H0NB0AQ JTDL063H0NB0AQ JTDL071H0NB0AQ Approximate
m3 0.38 0.38 0.38 0.52 0.52
Packing Measurement
Indoor Unit Power Supply 1N~, 220V/60Hz
Motor W 20 20 40 40 45 45 45 45
Connections
Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25 VP25
Approximate
m3 0.21 0.21 0.21 0.21 0.27 0.27 0.27 0.27
Packing Measurement
25 26
Specifications (Medium Static)
Model JTDM056H0NP0AQ JTDM063H0NP0AQ JTDM071H0NP0AQ JTDM224H0NM0AQ JTDM280H0NM0AQ
Indoor Unit Power Supply 1N~,220-240V/50Hz 3N~,380-415V/50Hz
Model JTDM056H0NB0AQ JTDM063H0NB0AQ JTDM071H0NB0AQ JTDM224H0NF0AQ JTDM280H0NF0AQ
Indoor Unit Power Supply 1N~,220V/60Hz 3N~,380V/60Hz
Indoor Units kW 5.8 6.5 7.3 23.2 28.6
Ducted Type
Nominal Cooling Capacity*1) kcal/h 5,000 5,600 6,300 20,000 24,600
Btu/h 19,800 22,200 25,000 79,200 97,600
kW 5.6 6.3 7.1 22.4 28.0
Nominal Cooling Capacity*2) kcal/h 4,800 5,400 6,100 19,300 24,100
270mm
Specifications (High Static)
False Ceiling
(2.2-7.1kW) Model JTDH084H0NP0AQ JTDH090H0NP0AQ JTDH112H0NP0AQ JTDH142H0NP0AQ JTDH160H0NP0AQ JTDH224H0NM0AQ JTDH280H0NM0AQ
Indoor Unit Power Supply 1N~,220-240V/50Hz 3N~,380-415V/50Hz
Model JTDH084H0NB0AQ JTDH090H0NB0AQ JTDH112H0NB0AQ JTDH142H0NB0AQ JTDH160H0NB0AQ JTDH224H0NF0AQ JTDH280H0NF0AQ
Indoor Unit Power Supply 1N~,220V/60Hz 3N~,380V/60Hz
kW 8.7 9.3 11.6 14.5 16.5 23.2 28.6
Nominal Cooling Capacity*1) kcal/h 7,500
Specifications (Medium Static) Btu/h 29,700
8,000
31,700
10,000
39,700
12,500
49,500
14,200
56,300
20,000
79,800
24,600
97,600
kW 8.4 9.0 11.2 14.2 16.0 22.4 28.0
Model JTDM022H0NP0AQ JTDM028H0NP0AQ JTDM036H0NP0AQ JTDM043H0NP0AQ JTDM050H0NP0AQ Nominal Cooling Capacity*2) kcal/h 7,200 7,700 9,600 12,200 13,800 19,300 24,100
Indoor Unit Power Supply 1N~, 220-240V/50Hz Btu/h 28,700 30,700 38,000 48,400 54,600 76,500 95,600
kW 9.6 10.0 13.0 16.3 18.0 25.0 31.5
Model JTDM022H0NB0AQ JTDM028H0NB0AQ JTDM036H0NB0AQ JTDM043H0NB0AQ JTDM050H0NB0AQ Nominal Heating
kcal/h 8,300 8,600 11,200 14,000 15,500 21,500 27,000
Capacity
Indoor Unit Power Supply 1N~, 220V/60Hz Btu/h 32,800 34,100 44,400 55,500 61,400 85,300 107,000
Sound Pressure Level
kW 2.3 2.9 3.8 4.4 5.2 dB (A) 42-39-35 42-39-35 43-40-36 44-41-37 45-41-37 50 52
(High/Medium/Low)
Nominal Cooling Capacity*1) kcal/h 2,000 2,500 3,300 3,800 4,500
Outer Dimensions
Btu/h 7,800 9,900 13,000 15,100 17,700 mm 350×(900+75)×800 350×(1,300+75)×800 470×1,060×1,120 470×1,250×1,120
H×W×D
kW 2.2 2.8 3.6 4.3 5.0
Net Weight kg 46 46 46 58 58 96 104
Nominal Cooling Capacity*2) kcal/h 1,900 2,400 3,100 3,700 4,300
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Btu/h 7,500 9,500 12,300 14,700 17,000 Indoor Fan
kW 2.8 3.3 4.2 4.9 5.6
Nominal Heating Air Flow Rate m3/min 25/21/17 25/21/17 27/23/19 37/31/25 38/35/29 58 72
kcal/h 2,400 2,800 3,600 4,200 4,800
Capacity (Hi/Me/Lo)
Btu/h 9,600 11,100 14,300 16,700 19,100 External Pressure (Option) *3) pa 120(90) 120(90) 120(90) 120(90) 120(90) 180 180
Sound Pressure Level Motor W 120 120 120 200 280 650 900
dB (A) 35-33-31 35-33-31 35-33-31 35-33-31 35-33-31
(High/Medium/Low) Connections
Outer Dimensions Flare-Nut Connection (with Flare Nuts)
mm 270×(650+75)×720 270×(900+75)×720 Refrigerant Piping
H×W×D Liquid Line mm Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53 Φ9.53
Net Weight kg 26 26 26 26 35 Gas Line mm Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ15.88 Φ19.05 Φ22.2
Condensate Drain VP25 VP25 VP25 VP25 VP25 VP25 VP25
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Approximate
Indoor Fan m3 0.38 0.38 0.38 0.52 0.52 0.9 1.06
Packing Measurement
Air Flow Rate m /min
3
8/7/6 8/7/6 13/11/9 13/11/9 15/13/11
(Hi/Me/Lo) NOTES:
1. The nominal cooling capacity is based on the JIS standard B8616.
External Pressure (Option) *3) pa 50(80) 50(80) 50(80) 50(80) 50(80) Cooling Operation Conditions
Indoor Air Inlet Temperature: 27°C DB (80°F DB)
Motor W 35 35 60 60 75
*1) 19.5°C WB (67°F WB)
Connections *2) 19.0°C WB (66.2°F WB)
Flare-Nut Connection (with Flare Nuts) Outdoor Ambient Temperature: 35°C DB (95°F DB)
Refrigerant Piping
Heating Operation Conditions
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Indoor Air Inlet Temperature: 20°C DB (68°F DB)
Outdoor Ambient Temperature: 7°C DB (45°F DB)
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88
6°C WB (43°F WB)
Condensate Drain VP25 VP25 VP25 VP25 VP25 Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
Approximate 1.5 Meter Beneath the Unit.
m3 0.21 0.21 0.21 0.21 0.27
Packing Measurement With Discharge Duct (2.0m) and Return Duct (1.0m).
Voltage of the power source for the indoor fan motor is 220V.
In case of the power source of 240V, the sound pressure level increases by about 1 dB.
27 28
Indoor Units Indoor Units
Specifications Specifications
Model JTDS022H0PP0AQ JTDS028H0PP0AQ JTDS036H0PP0AQ JTDS043H0PP0AQ
Model JTDN022H0PP0AQ JTDN028H0PP0AQ JTDN036H0PP0AQ JTDN043H0PP0AQ JTDN050H0PP0AQ JTDN056H0PP0AQ JTDN063H0PP0AQ JTDN071H0PP0AQ
Power Supply 1N~, 220-240V/50Hz Indoor Unit Power Supply 1N~,220-240V/50Hz
Model JTDS022H0PB0AQ JTDS028H0PB0AQ JTDS036H0PB0AQ JTDS043H0PB0AQ Model JTDN022H0PB0AQ JTDN028H0PB0AQ JTDN036H0PB0AQ JTDN043H0PB0AQ JTDN050H0PB0AQ JTDN056H0PB0AQ JTDN063H0PB0AQ JTDN071H0PB0AQ
Power Supply 1N~,220V/60Hz Indoor Unit Power Supply 1N~,220V/60Hz
KW 2.3 2.9 3.8 4.4 kW 2.3 2.9 3.8 4.4 5.2 5.8 6.5 7.3
Nominal Cooling Capacity *1 kcal/h 2,000 2,500 3,300 3,800 Nominal Cooling Capacity*1) kcal/h 2,000 2,500 3,300 3,800 4,500 5,000 5,600 6,300
Btu/h 7,800 9,900 13,000 15,100 17,700 19,800 22,200 25,000
Btu/h 7,800 9,900 13,000 15,000
kW 2.2 2.8 3.6 4.3 5.0 5.6 6.3 7.1
kW 2.2 2.8 3.6 4.3
Nominal Cooling Capacity*2) kcal/h 1,900 2,400 3,100 3,700 4,300 4,800 5,400 6,100
Nominal Cooling Capacity *2 kcal/h 1,900 2,400 3,100 3,700 Btu/h 7,500 9,500 12,300 14,700 17,100 19,100 21,500 24,200
Btu/h 7,500 9,500 12,300 14,700 kW 2.8 3.3 4.2 4.9 5.6 6.5 7.5 8.5
kW 2.8 3.3 4.2 4.9 Nominal Heating Capacity kcal/h 2,400 2,800 3,600 4,200 4,800 5,600 6,500 7,300
Nominal Heating Capacity kcal/h 2,400 2,800 3,600 4,200 Btu/h 9,600 11,100 14,300 16,700 19,100 22,200 25,600 29,000
Sound Pressure Level
Btu/h 9,600 11,100 14,300 16,700 dB (A) 27-24-21 27-24-21 31-29-26 31-29-26 34-30-28 34-30-28 35-33-30 35-33-30
(High/Medium/Low)
Sound Pressure Level Outer Dimensions
dB(A) 28-25-22 28-25-22 32-30-28 32-30-28
(High/Medium/Low) mm 192×900×447 192×1,170×447 192×1,170×447
H×W×D
Outer Dimensions
mm 192×700×602 192×700×602 192×700×602 192×700×602 Net Weight kg 20 20 21 21 26 26 26 26
H×W×D
Refrigerant R410A (Nitrogen-Charged for Corrosion-Resistance)
Net Weight kg 21 21 22 22
Indoor Fan Air Flow Rate
Refrigerant R410A (Nitrogen-charged for Corrosion-resistance) m3/min 8/7/6 8/7/6 10/8/7 10/8/7 14.5/12.5/10.5 14.5/12.5/10.5 16/14/12 16/14/12
(Hi/Me/Lo)
Indoor Fan Air Flow Rate External Pressure (Option) *3) pa 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30) 10(30)
m /min
3
8/7/6 8/7/6 10/8/7 10/8/7
(High /Medium /Low)
Motor W 16 16 25 25 40 40 50 50
Motor Power w 50 50 60 60
Connections
Connections Refrigerant Piping Flare-nut Connection (with Flare Nuts) Flare-Nut Connection (with Flare Nuts)
Refrigerant Piping
Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Liquid Line mm Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ6.35 Φ9.53 Φ9.53
Gas Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Ges Line mm Φ12.7 Φ12.7 Φ12.7 Φ12.7 Φ15.88 Φ15.88 Φ15.88 Φ15.88
Condensate Drain VP25 Condensate Drain VP25
External Static Pressure Pa 10(30) 10(30) 10(30) 10(30) Approximate Packing
m 3
0.15 0.15 0.15 0.15 0.18 0.18 0.18 0.18
Measurement
Approximate Packing Measurement m3 0.15 0.15 0.15 0.15
NOTES:
1. The nominal cooling capacity is based on the JIS standard B8616. 2. The sound pressure level is based on following conditions.
NOTES: 2. The sound pressure level is based on following conditions.
Cooling Operation Conditions 1.5 Meter Beneath the Unit.
1. The nominal cooling capacity is based on the JIS standard B8616. 1.5 Meter Beneath the Unit.
Indoor Air Inlet Temperature: 27°C DB (80°F DB) With Discharge Duct (2.0m) and Return Duct (1.0m).
Cooling Operation Conditions With Discharge Duct (2.0m) and Return Duct (1.0m).
*1) 19.5°C WB (67°F WB) Voltage of the power source for the indoor fan motor is 220V.
Indoor Air Inlet Temperature: 27°C DB (80°F DB) Voltage of the power source for the indoor fan motor is 220V.
*2) 19.0°C WB (66.2°F WB) In case of the power source of 240V, the sound pressure level increases by about 1 dB.
*1) 19.5°C WB (67°F WB) In case of the power source of 240V, the sound pressure level increases by about 1 dB.
Outdoor Ambient Temperature: 35°C DB (95°F DB) The above data was measured in an anechoic chamber so that reflected should be taken into consideration in the
*2) 19.0°C WB (66.2°F WB) The above data was measured in an anechoic chamber so that reflected should be taken
Heating Operation Conditions field.
Outdoor Ambient Temperature: 35°C DB (95°F DB) into consideration in the field.
Indoor Air Inlet Temperature: 20°C DB (68°F DB) 3. The data for external pressure *3) indicates” Standard Pressure Setting values when a filter is not used. Please
Heating Operation Conditions 3. The data for external pressure *3) indicates” Standard Pressure Setting values when a
Outdoor Ambient Temperature: 7°C DB (45°F DB) consider pressure deduction 10Pa in case of York filter accessory used on the unit.
Indoor Air Inlet Temperature: 20°C DB (68°F DB) filter is not used. Please consider pressure deduction 10Pa in case of York filter
Outdoor Ambient Temperature: 7°C DB (45°F DB) accessory used on the unit. 6°C WB (43°F WB)
6°C WB (43°F WB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
Piping Length: 7.5 Meters Piping Lift: 0 Meter
29 30
Indoor Units Indoor Units
Air Flow Rate m3/min. 15/13/11/9 19/16.5/14/11.5 21/18.5/15.5/12.5 30/26.5/22/17 35/31/25.5/20 37/32.5/27/21 Cabinet Color White
Hi2/Hi/Me/Lo (cfm) (530/459/388/318) (671/583/494/406) (742/653/547/441) (1,059/936/777/600) (1,236/1,095/900/706) (1,306/1,148/953/742) Dimensions H x W x D mm 300 x 790 x 230 300 x 790 x 230 300 x 790 x 230 300 x 900 x 230 333 x 1,150 x 245
Motor W 50 80 160 Net Weight kg 10 10 10 11 17 18
Connections Flare-Nut Connection (With Flare Nuts) Refrigerant R410A
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88 φ9.52 /φ15.88 Air Flow Rate m3/min. 8/7.5/7/6.0 10/8/7/6.5 14/11/9/7.5 15/14/13/10 19/17/14/12 22/19/17/15
Condensate Drain VP20 Hi2/Hi/Me/Lo (cfm) (282/265/247/212) (353/282/247/230) (494/388/318/265) (530/494/459/353) (671/600/494/424) (777/671/600/530)
Approximate Motor W 40
m3 0.23 0.31 0.38
Packing Measurement Connections Flare-Nut Connection (With Flare Nuts)
NOTES:
Liquid / Gas mm φ6.35 /φ12.7 φ6.35 /φ15.88 φ9.52 /φ15.88
1. The nominal cooling and heating capacity is based on the JIS standard B8616. Condensate Drain VP16
Cooling Operation Conditions Heating Operation Conditions Approximate m3 0.09 0.11 0.14
Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB) Packing Measurement
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
Standard Accessories Wall Mounting Bracket
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter NOTES:
2. The sound pressure level is based on following conditions. 1. The nominal cooling and heating capacity is based on the JIS standard B8616.
1 Meter Beneath the Unit and 1 Meter from Discharge Grille. Cooling Operation Conditions Heating Operation Conditions
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field. Indoor Air Inlet Temperature: 27˚C DB (80˚F DB) Indoor Air Inlet Temperature: 20˚C DB (68˚F DB)
*1) 19.5˚C WB (67˚F WB) Outdoor Ambient Temperature: 7˚C DB (45˚F DB)
*2) 19.0˚C WB (66.2˚F WB) 6˚C WB (43˚F WB)
Outdoor Ambient Temperature: 35˚C DB (95˚F DB) Piping Length: 7.5 Meters Piping Lift: 0 Meter
2. The sound pressure level is based on following conditions.
1 Meter Beneath the Unit and 1 Meter from Air Inlet Grille
The above data was measured in an anechoic chamber so that reflected sound should be taken into consideration in the field.
3. Dew condenstion water can be dropped out from air outlet under installation when some solid substances are intruded into a refrigerant pipe. Once the substances get inside of electric expansion
valve, the dew condensation occurred, because heat exchanger or fans get cooledwith subtle running in refrigerant. The dew condensation water can come out fromthe air oulet when its operation
started. Therefore, to prevent the intrusion of substances into electric expansion valve, it is strongly recommended to install Strainer Kit (optional part) into the refrigerant pipe nearby indoor unit.
*3) These models are the indoor unit without expansion valve. Expansion valve kit(JEV-1.5N1) should be used with the models
31 32
Optional Parts Remote Controllers
Indoor Units
The LED-backlit LCD provides enhanced legibility.
Four-Way Cassette Type Ducted Type (For JTDH/M/L/N/S *********Q) Remote Control Switch
Large, clear character display is realized by Full Dot Matrix LCD.
HP (kW) 1.0-6.0(2.8-16.0) HP (kW) 0.8 ~ 2.5(2.2-7.1) 3.0(8.4) 4.0(11.2) 5.0(14.2) JCWB10NEWS
Air Panel JP-AP160NA1/JP-AP160NAE (with motion sensor) Drain-up The directional key provides optimized operation.
JDUPI-132CQ JDUPI-162Q Compatible with the H-LINKⅡ
Mechanism Kit The manual operation is facilitated by reducing number of switch buttons from 13 to 9.
“Schedule Timer” provides the timer operations for “Run/Stop” and “Temperature Setting”.
Ducted Type (For JTDH/M *********S) The weekly management is available by using this function. In addition “Holiday Setting” and
Two-Way Cassette Type HP (kW) 0.8 ~ 1.5(2.2-4.3) 2.0 and 2.5(5.6 and 7.1) 3.0(8.4) 4.0(11.2) 5.0(14.2) “Schedule ON/OFF”setting are available.
HP (kW) 0.8 ~ 3.0(2.2-8.4) 4.0 ~ 6.0(11.2-16.0) Drain-up
Standard JDUPI-132CS JDUPI-162S
Air Panel JP-AP90DNA JP-AP160DNA Mechanism Kit 4 type of menus are offered for flexible use as follows:
Menu: Contains “Schedule”, “Screen Display Setting”, etc. for users.
Help Menu: Contains information provided by this remote control switch for users such as
Ceiling Suspended Type
“About Indication”, “Contact Information”, etc.
HP (kW) 1.5(4.3) 2.0(5.6) 2.5 to 6.0(7.1-16.0)
Test Run Menu: This menu provides the functions installation of this remote control switch.
Drain-up Mechanism JDUPC-63K1 JDUPC-71K1 JDUPC-160K1
Check Menu: This menu provides the functions for service and maintain
Mini Four Way Cassette Type High Wall Type Receiver Kit for Wireless Control
HP (kW) 0.6 ~ 2.5(1.6-7.1) HP (kW) 0.6 ~ 1.5(1.6-4.3) JTKF JTKM JTKT JTCS JTDH/M/L/N/S JTHW
Air Panel JP-AP56NAM Electronic Model JR4A10NEWS JRMA10NEWS JR2A10NEWS JRCA10NEWS JRDA10NEWS JRDA11NEWS*2
JEV-1.5N1
Expansion Valve Kit *1 Remote Control Switch The LCD display permits users to see the operating conditions and settings.
NOTES:
*1. The electronic expansion valve kit (optional part JEV-1.5N1) should be used with indoor unit high wall type JCWA10NEWQ The timer can be set at half-hour intervals up to 72 hours.
without expansion valve together. Compatible with the H-LINKⅡ All the functions can be selected by remote control switches.
*2. Wall mounted type
JCWA10NEWQ monitors the operating conditions in the system and an alarm is issued if a
Piping Connection Kit Strainer Kit problem occurs.
Operation Type Applicable Outdoor Unit Product Name Model
Heat Pump Operation Heat Recovery Operation JUOD Series (HP) A "self-diagnosis function" checks for problems on printed boards in indoor andoutdoor units.
MSF-NP63A MSF-NP112A
Strainer Kit
JMC-NP20A1 JMC-NP20X1 16 to 24 MSF-NP36AH*1 Equipped with energy-saving functions such as a preset temperature range limiting function for
JMC-NP30A1 JMC-NP30X1 26 to 36 NOTE: preventing excessive cooling/heating and a preset temperature automatic reset function, as well
*1. For without Expansion Valve indoor unit. as an operation locking mechanism and the capability to prevent users from forgetting to turn off
the system. (Function selection setting is required)
Multi-kits
Multi-kit for 2 Pipe Heat Pump Operation Multi-kit for 3 Pipe Heat Recovery Operation
< Line Branch > (First Branch) <Header Branch > < Line Branch > (First Branch) < Header Branch > One-touch handy operation, no wiring work required.
Outdoor Unit HP Model
Wireless
Total Outdoor Unit HP Model Total
Indoor Unit
No. of
Model Indoor Unit
No. of
Model Remote Control Switch Two or more units can be operated simultaneously by remote control.
8 to 10 JMW-NP282A2 Header Branches 8 to 10 JMW-NP282X2 Header Branches
HP(kW) HP(kW)
12 and 16 JMW-NP452A2 12 and 16 JMW-NP452X2 JCRB10NEWS * Receiver kit is required.
18 to 24 JMW-NP692A2 5 to 8(14.2 to 22.4) 4 JMH-NP224A 5 to 10(14.2 to 28.0) 8 JMH-NP288X Compatible with the H-LINKⅡ
18 and 20 JMW-NP562X2
26 to 36 JMW-NP902A2 5 to 10(14.2 to 28) 8 JMH-NP288A 22 and 24 JMW-NP692X2
NOTE: After the second branch, please refer to the technical manual. 26 to 36 JMW-NP902X2
Half-size The main function of this easy-to-use remote control system is temperature setting.
Control System : Applicable : Not Applicable Remote Control Switch Operation modes can be switched over (when function selection setting is made).
JTKF JTKM JTKT JTDH/M/L/N/S JTCS JTHW JCSA10NEWS Suitable for facilities used by various people, such as hotels.
Compatible with the H-LINKⅡ
JCWA10NEWQ*
1 "2 remote control" or "group control" (up to 16 max.) can be used.
Remote Control Switch
JCWB10NEWS*
1 If a problem occurs, an alarm code immediately shows the details of the problem.
Wireless Remote Control Switch JCRB10NEWS
Half-size Remote Control Switch JCSA10NEWS
Central Station mini JCMA101EWS Only performs operation/stop control per remote control group.
Centralized
Central Station EZ JCTA121EWS ON/OFF Controller By connecting to the H-LINK, up to 16 remote control groups and 160 indoor units can be controlled.
Centralized ON/OFF Controller JCOA111EWS Up to 8 units can be connected to the H-LINK.
JCOA111EWS
NOTES: *1. As the JCWA10NEWQ and JCWB10NEWS does not include a remote control cable, prepare one in the field, or use PRC-5K, 10K, or 15K. Compatible with the H-LINKⅡ An external input terminal is provided as standard. External signals enable thefollowing functions:
・central operation/stop, emergency stop,
Up to 160 indoor units
・central operation output, central alarm output
Up to 16 remote control groups * Make sure to use it with a remote control switch. Indoor units cannot be used without a remote control switch.
* There are restrictions on remote group registration. Please contact our sales staff for more information.
33 34
Network Systems
CS-NET Central Station
Specification
The flexibility of the YORK VRF system allows the internal data to be easily accessed and controlled by the user,
Central Station mini Communication Unit Units of Adopting for H-LINKⅡ
with features including temperature, mode and fan speed setting and groupings.
JCMA101EWS Communication Line Non-Polar 2-Wire
Communication Method Half-Duplex Communication
Synchro System Asynchronous (start-stop synchronous communication)
Communication Speed 9,600bps
140mm
*: Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).
Functions
JCTA121EWS JCMA101EWS JCOA111EWS Most compact in our touch panel centralized • Run/Stop/Abnormality • Operation Mode
controller. • Setting Temperature • Setting Fan Speed • Setting Louver
H-LINKⅡor H-LINKⅡor Its down-to-detail control functionalities, Monitor Function
• RCS Operation Prohibited Setting • Filter Sign • Alarm Code
H-LINK*1 H-LINK*1 such as Weekly Scheduling, Accumulated Work • Accumulated Operating Time
Hours, etc., help you save energy.
• Run/Stop* • Operation Mode • Temperature Setting
H-LINKⅡor Up to 32 remote-controlled groups and up to
Outdoor Units Control Function
• Fan Speed • Louver • RCS Operation Prohibited • Filter Sign Reset
H-LINK*1 160 indoor units can be connected to the single
air-conditioning system. *: groups
“All Groups Run/Stop” command signal exception function for selected
is available by “Exception of Run/Stop Ope.” function.
JUOD Series
Specification
Central Station EZ Communication Unit Units of Adopting for H-LINKⅡ
Indoor Units JCTA121EWS Communication Line Non-Polar 2-Wire
Communication Method Half-Duplex Communication
JTKT JTCS Synchro System Asynchronous (start-stop synchronous communication)
Communication Speed 9,600bps
JTKF JTHW
170 Wiring Length 1,000m (Total Length)
JTKM JTDH/M/L/N mm
Outdoor Unit Indoor Unit Central Controller Total Unit Number
Connecting
H-LINKⅡ 64 160 8 200
Unit Number*
Remote Controllers H-LINK 16 128 8 145
: Connecting unit quantity indicates the maximum unit numbers which is possible to connect in the same H-LINK (Control Wiring).
*1: Though connection with H-LINKⅡ is available, 250mm *
the resulting performance is equivalent to that
of the H-LINK specifications.
Functions
Eazy control with 8.5 inch color touch panel • Run/Stop/Abnormality • Operation Mode
Its down-to-detail control functionalities, • Setting Temperature • Setting Fan Speed • Setting Louver
JCWB10NEWS JCWA10NEWQ JCRB10NEWS Receiver Kit JCSA10NEWS
such as Weekly Scheduling, Accumulated Work Monitor Function
• RCS Operation Prohibited Setting • Filter Sign • Alarm Code
Hours, etc., help you save energy. • Accumulated Operating Time
Up to 64 remote-controlled groups and up to
• Run/Stop* • Operation Mode • Temperature Setting
160 indoor units can be connected to the single Control Function
• Fan Speed • Louver • RCS Operation Prohibited • Filter Sign Reset
air-conditioning system.
*: groups
“All Groups Run/Stop” command signal exception function for selected
is available by “Exception of Run/Stop Ope.” function.
35 36
H-LINK . . . H-LINKⅡ
YORK's proprietary high-performance transmis- The H-LINK transmission system for connection between outdoor
sion system for connecting control wires between and indoor units provides an extended system
indoor and outdoorunits, and between a centralized configuration and improved functions without sacrificing
control system and indoor/outdoor units, across two workability and the flexibility.
or more refrigerant systems.
Example : H-LINKⅡ Control Wiring
Regardless of Multi-Split System for Buildings or * : The above example shows the case
that central control device, indoor
units and remote control switch
Packaged System for Commercial Use are all corresponding to H-LINKⅡ
system.
By providing a common control function and wiring
method, a multi-split air conditioning system for CS-NET
buildings and a packaged air conditioning system
for commercial use are simultaneously used in the
same system. Just connect all the systems with
twin core cables by crossover connection. Central Station mini
Centralized ON/OFF
Controller
Adapters or other appliances are not required. JCMA101EWS JCOA111EWS
H-LINKⅡ System
Item H-LINKⅡ
Max. Number of Refrigerant Group / System 64
Address Setting Range of Indoor Units / Refrigerant Group 0 to 63
Max. Number of Indoor Unit / System 160
Total Number of Devices in the same H-LINK 200
Max. Wiring Length Total 1,000m
System Configuration
JUOD Series
Outdoor Unit
H-LINKⅡ
37 38
Johnson Controls, the Johnson Controls logo, YORK are registered trademarks of Johnson Controls, Inc in the United States of America and other countries. Other
trademarks used herein may be trademarks or registered trademarks of other companies.
FOR MORE INFORMATION CONTACT JOHNSONCONTROLS.COM
© 2016 Johnson Controls, Inc, P.O. Box 423, Milwarkee, WI 53201, All rights reserved worldwide. JUOD-VPEM0AS-161104