You are on page 1of 57

Etisalat Wireless Network

Modernization Project Introduction


www.huawei.com

2014-Jan-2

HUAWEI TECHNOLOGIES CO., LTD. Page 1


BBU Main Processing & Transmission unit

LMPT (LTE Main Processing & Transmission unit)


GTMU (GSM Transmission & Timing & Management Unit) 2FE/GE electrical port, 2FE/GE optical port , Support IPSec
4E1/T1, 1FE electrical port, 1FE optical port

WMPT (WCDMA Main Processing & Transmission unit) UMPT (Universal Main Processing & Transmission Board)
4E1/T1, 1FE electrical port, 1FE optical port
 Support IPSec, GUL concurrent mode(SRAN8.0)
 4E1/T1, 1FE/GE electrical port, 1FE/GE optical port

0 4 FE/GE (Electrical) E1/T1


UPEU
FAN
1
2
5
6
UMPT
UPEU
3 7

WMPT/LMPT/UMPT inserted in slot 6/7


GTMU inserted in slot 6(both slots 5 and 6 occupied) CI
FE/GE (Optical)
G/ U/L light indicator

HUAWEI TECHNOLOGIES CO., LTD.


WBBPf4/LBBPd board
Function:
Provides CPRI ports for communication with the RF modules (RRU)
Processes uplink and downlink baseband signals.
WBBPf for 3G
WBBPf inserted in slot 0/1/2/3/4/5
0 4
UPEU
FAN 1 5
2 6 UPEU
3 7

Interface ports: 6 (CPRI0 ~CPRI5) WBBPf4: 6 cells, DL/UL: 768CE/512CE

LBBPd for LTE


LBBPd inserted in slot 0/1/2/3/4/5
0 4
UPEU
FAN 1 5
2 6 UPEU
3 7

Interface ports: 6 (CPRI0 ~CPRI5) LBBPd3: 6x20M, 2T2R, DL/UL: 600M/300Mbps

HUAWEI TECHNOLOGIES CO., LTD.


UCIU/UBRIb board
UCIU: universal inter-connection infrastructure unit
S0 GCK
UCIU inserted in slot 4

0 4
UPEU
FAN 1 5
2 6 UPEU
3 7
M0 ~ M4

UBRIb for 2G
Provides CPRI ports for communication with the RF modules (RRU)
UBRIb inserted in slot 0~3

0 4 UPEU
FAN
1 5
2 6 UPEU
3 7
BBU3900

HUAWEI TECHNOLOGIES CO., LTD.


WMPT /LMPT/GTMUb evolved.

UPEU UPEU
F F
A A
N UMPT(GUL)
N UPEU
UPEU LMPT
LBBP LMPT LBBP
evolved

LMPT evolved: supports SingleOM and provides LTE signaling processing function.

HUAWEI TECHNOLOGIES CO., LTD.


BBU3900 Slot Assignment solution –reusing the existing BBU

UBRIb+2G900 UBRIb+2G900

UBRIb+2G1800 UBRIb+2G1800

WBBPf+3G900 WBBPf+3G900
UMPT Existing

LBBP+4G1800 UMPT LBBP+4G1800 LMPT


(Existing L) (Existing L) New

Reusing the existing 4G BBU ,existing Reusing the existing 4G BBU ,existing
UMPT board, New LMPT board, New New
2G900&2G1800+3G900 2G900&2G1800+3G900

HUAWEI TECHNOLOGIES CO., LTD. Page 6


BBU3900 Slot Assignment solution –New BBU

UBRIb+2G900 UBRIb+2G900

UBRIb+2G1800 UBRIb+2G1800

WBBf+3G900

UMPT
UMPT (G)
(G+U)

New 2G900&2G1800+3G900 with new BBU


New 2G900+2G1800 with new BBU

HUAWEI TECHNOLOGIES CO., LTD. Page 7


BBU3900 Working in Multi-Mode with a Co-MPT

Typical board configurations for a BBU3900 with a UMPT_GU board

HUAWEI TECHNOLOGIES CO., LTD. Page 8


New MiniShelter equipment layout (2.1M+AH1500&PC500D+Rack)
cable tray(1U) 1
2
Item Equipment Compartment
3
spare Space(6U)
4 Internal dimensions: 800 mm
5
6
x 800 mm x 1800 mm (31.50
7 in. x 31.50 in. x 70.87 in.)
DCDU12B-3(0U) 8 Basic unit
DCDU12B-2(1U) 9
specifications Maximum external
10
BBU2(2U)
11
dimensions: 905 mm x 1135
spare Space(1U) 12 mm x 2110 mm (35.63 in. x
DCDU12B-1(1U) 13
44.68 in. x 83.07 in.,
14
BBU1(2U)
15
16 AH1500 (maximum power
spare Space(2U)
17 Typical consumption ≤ AC/ DC 640
18
19 temperature W/200 W)
20 control mode PC500D (maximum power
Rectifier ETP48200(6U)
21
22 consumption ≤ DC 200 W)
23
24 Power system, baseband unit
25
26 (BBU), environment
27
Battery1
28
monitoring unit, alternating
29 Integration current distribution box
30
31
(ACDB), and automatic
32 transfer switch (ATS), and so
33
34
on
35
Battery2
36 IP protection
37 IP55
38
level
39
40 Weight ≤ 240 kg (529.20 lb)

HUAWEI TECHNOLOGIES CO., LTD. Page 9


New MiniShelter installation information
Install as
single
cabinet Cabinet bottom
base view

HUAWEI TECHNOLOGIES CO., LTD. Page 10


New minishelter Rectifier-ETP48200
Power Specifications

Rectifier module
(PSU)

HUAWEI TECHNOLOGIES CO., LTD. Page 11


New minishelter AC power cable connection
Single phase case

HUAWEI TECHNOLOGIES CO., LTD. Page 12


New minishelter Battery cable connection

One string battery= 4 pcs


sell.
Battery capacity:100AH.
Weight: 124KG/string

HUAWEI TECHNOLOGIES CO., LTD. Page 13


New minishelter Power monitoring unit

Signal resource Alarm name Alarm type Power port Cable color
BBU port
Mains failures NO ALM1 White/orange+, Orange-
DC low voltage NO ALM2 UPEU white/green+, Blue-
Rectifier failures NO ALM3 EXT-ALM1 white/blue+, Green,
Minishelter SPD failure NO ALM4 white/brown ,Brown-
alarm list: Load Breaker burn-out NO ALM5 White/orange+, Orange-
High temperature NO ALM6 white/green+, Blue-
Door open NO ALM7 UPEU white/blue+, Green,
Air-conditioner failures NO ALM8 EXT-ALM0 white/brown ,Brown-

HUAWEI TECHNOLOGIES CO., LTD. Page 14


New minishelter Power alarm cable connection

HUAWEI TECHNOLOGIES CO., LTD. Page 15


New minishelter sensor cable connection

Temperature & Battery Temperature


Door sensor
humidity sensor sensor
sensor

HUAWEI TECHNOLOGIES CO., LTD. Page 16


New minishelter Grounding cable connection
EMUA (1U)

Door
Rack
Space (15U)
Rack Ground Point
Grounding cable DCDU Indoor ground busbar
layout SLPU(1U)
BBU
Power
Power
System
ETP48200
DCDU (1U)
BBU (2U)
(8U) SLPU (1U)

12V 12V 12V 12V


150Ah 150Ah 150Ah 150Ah

12V 12V 12V 12V


150Ah 150Ah 150Ah 150Ah

Ground Outdoor ground busbar

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C System Specifications

Dimensions (H x W 630 mm x 450 mm x 300 mm (The width of the protruding part of the door [60 mm]
2 3 4 5 x D) is extracted from the cabinet depth.)

Weight ≤ 29 kg (excluding the weights of PSUs and storage batteries)

The maximum current is 60 A, in which case three 30 A PSUs are installed. 15 A


Rated capacity
PSUs are also supported.

Installation Mounted on a wall, floor, or pole.

Cable routing Cables are routed out from the bottom.

Maintenance Maintained from the front, supporting module replacement.


1
Protection level IP55

Noise The operation noise is lower than 55 dB, complying with YD/T 1058
6
Heat dissipation Natural-ventilation unit
7
Battery (optional) Built in with a 48 V 20 Ah/40 Ah battery string.

Electrical Specifications
8 Single-phase (L-N or L1-L2. The live wire and neutral wire can be reversely
AC input system
connected.)

Input voltage 85=300VAC (The rated input voltage is 220 V AC.)

Input frequency 45–65 Hz (The default input frequency is 50 Hz or 60 Hz.)

Output voltage 43.2–58 V DC (The default output voltage is 53.5 V DC.)


Internal Components
1 PSU 6 Battery Space AC surge protection Level C (20/40 kA, 8/20 µs). Level B (30/60 kA, 8/20 µs) can be customized.
level
2 PMU 7 Baffle plate
3 Fan 8 Air Filter Differential mode: 10 kA
DC surge protection
Common mode: 20 kA
4 Power distribution unit (PDU) 9
5 Surge protection for Differential mode: 3 kA
Door monitor 10
signal ports Common mode: 5 kA

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C installation information

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C installation information

Item Specifications
Rated capacity 40 Ah
Rated voltage 48 V DC
Operating temperature –20°C to +55°C
Dimensions (H x W x D) 133 mm x 385 mm x 350
mm
Weight ≤ 27 kg
Maximum discharge power 1500 W (the backup time is
1 hour)
Maximum charge current 8A

HUAWEI TECHNOLOGIES CO., LTD.


New TP4860C installation information

Item TP4860C-D06A1

AC input circuit One 2-pole 32 A


breaker circuit breaker
Maintenance socket 1
AC surge protection
Class C, 4-pole
device (SPD)
DC SPD 1
DC output circuit Three 1-pole 32A
breaker circuit breakers
Battery circuit One 1-pole 63 A
breaker circuit breaker

HUAWEI TECHNOLOGIES CO., LTD.


DCDU12B View

HUAWEI TECHNOLOGIES CO., LTD. Page 24


APM30 DC(TMC11H ,Ver.D)
Exterior of the APM30H(TMC11H) Power Specifications
Supplied with -48 V DC power.
Configured with a DCDU-12B, which distributes power into RRUs and the
BBU, fan assembly, and transmission equipment in the TMC11H
.Parameter Specifications
Characteris Input voltage range -38.4 V DC to -57 V DC
tics of DC Typical input voltage -48 V DC
input
Maximum input current •The maximum input current depends on the application
scenario. In a distributed base station: 160 A
•In a separated macro base station: 30 A (When the TMC11H is
configured together with the APM30H, the APM30H supplies
power to the TMC11H.)
Input mode -48 V DC power input, supporting the one-hole M6 OT terminal
Characteris DC distribution Ten -48 V DC outputs: LOAD0 to LOAD9, used to supply power
tics of DC to the customer equipment
output Typical output voltage -48 V DC
Protection Providing overcurrent protection and short-circuit protection for
the DC power

HUAWEI TECHNOLOGIES CO., LTD. Page 25


APM30H DC (TMC11H ,Ver.D)
Exterior of the APM30H
Parameter Specifications Remarks
Dimensions (H x Cabinet (without the The TMC11H and APM30H have the same
W x D) base): 700 mm x 600 mm exterior and base.
x 480 mm (27.56 in. x
23.62 in. x 18.90 in.)
Base: 200 mm x 600 mm
x 434 mm (7.87 in. x
23.62 in. x 17.09 in.)
Space for the 11 U x 19 in. x 380 mm The depth includes 100 mm (3.94 in.) in front of
customer the columns and 280 mm (11.02 in.) between the
equipment (H x W columns and the rear of the cabinet.
x D)
Cabinet weight ≤ 47 kg (103.64 lb) Total weight of the equipment
Including the cabinet frame, outer air
circulation assembly (heat dissipation core and
outer air circulation fan), inner air circulation
fan assembly, DCDU, and cables
Excluding the customer transmission
equipment
Method of It can be installed on the In stack mode, the TMC11H must be installed on
installation ground, pole, or wall. It the top of the RFC, IBBS200D, or IBBS200T
can also be installed on
an RFC, IBBS200D, or
IBBS200T in stack mode.

HUAWEI TECHNOLOGIES CO., LTD. Page 26


APM30 H( TMC11H VerD detail component)
No. Component Remarks
1 Outer air
circulation The assembly is installed on the front door of the cabinet, dissipating heat from the cabinet.
assembly
2 The junction box converts one AC input to four AC outputs and is used in the scenario where a service outlet unit (SOU) and
Junction box
multiple heating films or heaters are configured.
3 FAN 02D The fan assembly is configured with fans and central monitoring unit type EA (CMUEA), dissipating heat from the cabinet.
4 To provide protection for trunk signals,
SLPU
To provide protection for monitoring signals.
5 Door sensor The door status sensor monitors the status (open or closed) of the cabinet door.
6 ELU The electronic label unit (ELU) reports the cabinet type automatically to facilitate troubleshooting.
7 The direct current distribution unit-12B (DCDU-12B) or direct current distribution unit-12C (DCDU-12C) in the TMC11H
DCDU-12B or
distributes DC power to all the components in the TMC11H. A DCDU-12B or DCDU-12C is 1 U high. The DCDU varies with the
DCDU-12C
installation scenarios.
8 BBU3900 A maximum of two BBU3900s can be configured in a TMC11H.
9 EMUA The environment monitoring unit type A (EMUA) monitors environment of the equipment.
10 A filler module is a plastic component with a height of 1 U in the cabinet, preventing the heat reflux in the empty space below the
Filler module
BBU.
11 The AC heater ensures that components in the cabinet work within the acceptable temperature range when the surrounding
AC heater
temperature is low. It can be preferentially installed in the 1 U space at the bottom of the cabinet.

HUAWEI TECHNOLOGIES CO., LTD. Page 27


APM30 AC (Ver.D)
Exterior of the APM30H AC Power Specifications
Item Specifications

200 V AC to 240 V AC (220 V AC single-phase)

200/346 V AC to 240/415 V AC (220/380 V AC three-phase)


Typical input voltage
100/200 V AC to 120/240 V AC (110 V AC dual-live-wire)
Characteristics of AC input
120/208 V AC to 127/220 V AC (120 V AC dual-live-wire)

53 A (220 V AC single-phase)
23 A (220/380 V AC three-phase)
Rated input current
55 A (110 V AC dual-live-wire)
52 A (120 V AC dual-live-wire)
Output voltage range -43.2 V DC to -57 V DC
Output current range 0 A to 150 A
Typical output voltage -53.5 V DC

The number of DC outputs depends on the application scenario.

Characteristics of DC output DC outputs A distributed base station uses 17 DC outputs

A separated base station uses 12 DC outputs.

≤ 9000 W (When there is no backup PSU, the maximum power of each PSU is
DC output power
3000 W.)

HUAWEI TECHNOLOGIES CO., LTD. Page 28


APM30H AC (Ver.D)
Item Specification Remarks
Exterior of the APM30H
Total weight of the equipment
Including the cabinet frame, inner air
circulation fan box, outer air circulation
fan box, core of the heat exchanger,
≤ 68 kg embedded power subrack unit (EPU),
and cables
Weight Excluding the baseband processing unit
(BBU), customer equipment, power
monitoring unit (PMU), and PSUs
Weight of the cabinet in full configuration
Including the cabinet, one PMU, three
≤ 87 kg
PSUs, and one BBU
Excluding customer equipment
Cabinet dimensions (H x W x D) 700 mm x 600 mm x 480 mm The base is not included.

Base dimensions (H x W x D) 200 mm x 600 mm x 434 mm -


The depth consists of the rear (280 mm)
Customer equipment dimensions (H
7 U x 19 in. x 380 mm and front (100 mm) of the installation
x W x D)
plane for subrack mounting ears.
Space for cabling and maintenance
70 mm -
in front of the cabinet

The APM30H can be installed


on a floor, wall, or pole. It can
Installation option also be stacked with the radio The APM30H must
frequency cabinet (RFC),
IBBS200D, or IBBS200T.

HUAWEI TECHNOLOGIES CO., LTD. Page 29


APM30H AC-APM30H+Battery(Used for a Distributed Base Station)
Figure 1 Scenario where the APM30H is stacked with a battery cabinet and is used for a distributed base station

When the APM30H is used for a distributed


base station:
The APM30H provides 7 U-high space for
installing the BBU and transmission
equipment. The embedded power supply
system provides -48 V DC power to the
distributed base station and transmission
equipment and charges battery groups in a
battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the distributed base station and
transmission equipment

HUAWEI TECHNOLOGIES CO., LTD. Page 30


APM30H AC-BTS3900A(Used for an Outdoor Macro Base Station)
Figure 2 Scenario where the APM30H is used for an outdoor macro base station

When the APM30H is used for an outdoor


macro base station:
The APM30H provides 7 U-high space for
installing the baseband processing unit (BBU)
and transmission equipment. The embedded
power supply system provides -48 V DC power
to the BBU, radio frequency unit (RFU), and
transmission equipment and charges battery
groups in a battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the BBU, RFU, and transmission
equipment.
The APM30H provides alarm reporting functions
for radio frequency cabinet (RFC) fans, door
status sensor, direct current distribution unit
(DCDU), and battery cabinet.

HUAWEI TECHNOLOGIES CO., LTD. Page 31


OMB (Ver.C)
The OMB (Ver.C) is designed for SRAN8.0 and later versions
Base stations supported by the OMB (Ver.C):
DBS3900
The OMB (Ver.C) supports all current RRU versions.

DBS3900 (AC) DBS3900 (DC)

Page 32
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.CMPE Specifications ) in AC Scenarios
Dimensions (H x W x D) 600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)

Temperature Range -33oC to 50oC (-27.4oF to 131oF)

Weight 30 kg or 66.15 lb (without a BBU)

Protection Class IP55

Admission Requirement CE

Power Supply Mode 110 V AC dual-live-wire or 220 V AC single-phase

Temperature Control Subsystem Heat exchanger

Power Supply Subsystem Embedded power system, with a maximum power capacity of 100 A
ETP48100-A1 Output DC power distribution: two 100 A outputs

Power Distribution Subsystem Ten power outputs of 30 A

AC power port: rated 20 kA; maximum 40 kA; 8/20 us waveform

Surge Protection DC power output port: 10 kA in differential mode and 20 kA in


common mode; 8/20 us waveform

Cable Outlet Position Bottom of the cabinet

Page 33
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in AC
Scenarios
No. Configuration Description

1 Mandatory Electronic label unit (ELU)


1
2 2 Mandatory FAU01D-01 (inner air circulation fan
3 assembly)
4
3 Mandatory Door status sensor
5
6 4 Mandatory SPD40/S (AC surge protector)

7 5 Mandatory HEUB (control unit for heat


exchanging)
8
6 Mandatory PMU11A (power management unit)

7 Mandatory PSU (R4850G2 rectifier)

8 Mandatory PDU10D-01 (DC power distribution


9 unit)
9 Mandatory ETP48100-A1 (embedded power
system)
10 Mandatory FAU01D-01 (outer air circulation
10 fan assembly)

Page 34
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.C) MPE Specifications in DC Scenarios
Dimensions (H x W x D) 600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)

Temperature Range -33oC to 50oC (-27.4oF to 131oF)

Weight 21 kg or 46.31 lb (without a BBU)

Protection Class IP55

Admission Certification CE

Power Supply Mode -48 V DC

Temperature Control
Heat exchanger
Subsystem

Power Distribution
Ten power outputs of 30 A
Subsystem

DC power output port: 10 kA in differential mode and 20 kA in common mode;


Surge Protection
8/20 us waveform

Cable Outlet Position Bottom of the cabinet

Page 35
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in DC
Scenarios
No. Configuration Description

1
2 1 Mandatory ELU
3
4 2 Mandatory FAU01D-01 (inner air circulation fan
assembly)
3 Mandatory Door status sensor
5
6 4 Mandatory HEUB (control unit for heat
exchanging)
5 / 1 U space for customer equipment

6 Mandatory PDU10D-01 (DC power distribution


unit)
7 Mandatory FAU01D-01 (outer air circulation fan
7 assembly)

Page 36
HUAWEI TECHNOLOGIES CO., LTD.
Engineering Interface of the OMB (Ver.C)
 Engineering Interface of the OMB (Ver.C) in AC Scenarios
AC Input Mode Number of PSUs Requirements for AC Circuit Input Power Cable Remarks
Breakers
220 V AC single-phase 2 32 A, 1 P 4 mm2 The circuit breaker is connected to the L phase.

110 V AC dual-live-wire 2 32 A, 2 P 4 mm2

220 V AC single-phase 1 20A, 1 P 4 mm2 The circuit breaker is connected to the L phase.

110 V AC dual-live-wire 1 20 A, 2 P 4 mm2

 Engineering Interface of the OMB (Ver.C) in DC Scenarios


Related Unit RRU Power Number of Requirements for Input Power Distance Between the OMB (Ver.C)
Configuration RRUs DC Circuit Breakers Cable and External Power Equipment

≤ 300 W 1~3 50A, 1 P 16 mm2 5m


1. The AC input power cables are single-
BBU: 450
≤ 300 W 4~6 80 A, 1 P 16 mm2 5m core cables, each with dual insulation
W
RRUs of ≤ 400 W 1~3 63 A, 1 P 16 mm2 5m
the same ≤ 400 W 4~6 100 A, 1 P 16 mm2 5m layers.
model ≤ 560 W 1~3 80 A, 1 P 16 mm2 5m 2. If more PSUs are added, the customer
≤ 560 W 4~6 125 A, 1 P 25 mm2 5m
engineering interface must be changed.
2x60 A, 2 P 2x16 mm2 5m

BBU: 450 ≤ 300 W 3 Therefore, ensure that the circuit


W ≤ 300 W 3 80 A, 1 P 16 mm2 5m
breakers and power cables meet the
RRUs of ≤ 400 W
different ≤ 300 W 3 requirements before the PSUs are
models ≥400W 3 100 A, 1 P 16 mm2 5m added.
≤ 560 W
≤ 400 W 3 100 A, 1 P 16 mm2 5m

Page 37
HUAWEI TECHNOLOGIES CO., LTD.
Application Scenarios of the OMB (Ver.C)
Rooftop Outdoor-S2 Greenfield Outdoor- Urban Street-S5 Indoor-S6 Rural Road-S7
S4

 Installing on  Installing on  Installing on  Installing on  Installing on


the pole of the bottom of the Lamp pole the carport the pole of
rooftop the tower of the street  Installing on the road side
 Installing on side the wall of
the wall of veranda
rooftop

Page 38
HUAWEI TECHNOLOGIES CO., LTD.
Stacking the OMB (Ver.C) onto the Top of the BTS3900A

Item Quantity Description


Adapting piece I 2 Secured to the lifting eyes on the
top of the BTS3900A

Adapting piece IV 2 Used to secure adapting piece I to


the rear of the OMB

The solution of stacking the OMB (Ver.C) onto the BTS3900A is


carried out only as a non-standard solution.

Adapting piece IV
Adapting piece I

Page 39
HUAWEI TECHNOLOGIES CO., LTD.
The changes from OMB Ver.A to OMB Ver.C
AC SPD
SPD40/S

OMB Ver.A OMB Ver.C


New ELU
unit

New PDU

EPS30-4815AF ETP48100-A1
HUAWEI TECHNOLOGIES CO., LTD. Page 40
DBS3900 (-48 V): Outdoor BBU and Outdoor RRUs (Ver.C)
Solution: OMB(-48 V) + 6 x RRU (optional)
DC power cable A DC OMB Ver.C supports a maximum of six 2x60 W RRUs.
ground cable The heat consumption of a DC OMB Ver.C cabinet (the total heat consumption of the built-in
feeder BBC and TC) is lower than or equal to 450 W (with the urban-level noise and in ambient
Optical fiber temperature of 50ºC.)
The DC OMB Ver.C supports -48 V power input.
The protection level of the DC OMB Ver.C is IP55.
RR The DC input/output port surge protection specification is 10KA/20KA.
U The DC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both
OMB V.C on the top of and beside a BTS3900A. In this case, an attachment plate is required and no
Power interface footprint is required.
ACDB The DC OMB Ver.C can operate in a temperature range of -33ºC to +50ºC.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless
Base Stations.

Customer side

Page 41 Back
HUAWEI TECHNOLOGIES CO., LTD.
DBS3900 (AC): Outdoor BBU and Outdoor RRUs (Ver.C)
Solution: OMB (AC) + 6 x RRU (optional)
An AC OMB Ver.C supports a maximum of six 2x60 W RRUs (power backup is not supported when the
load power exceeds 3000 W).
AC power cable
An AC OMB Ver.C has a built-in ETP48100 power supply system and two PSUs, with a maximum output
ground cable
feeder power of 6000 W (3000 W for a single PSU.)
DC power cable The AC OMB Ver.C supports 220 V single-phase and 110 V dual-live-wire AC input.
optical fiber The heat consumption of an AC OMB Ver.C cabinet is lower than or equal to 450 W (the heat consumption
of the BBU is lower than or equal to 250 W) with the urban-level noise and in ambient temperature of
RRU 50ºC.
The protection level of the AC OMB Ver.C is IP55.
OMB V.C The AC OMB Ver.C cannot be installed on a tower and can not be installed at a position higher than 10 m.
Power interface The AC OMB Ver.C supports remote RRU.
ACDB The AC OMB Ver.C supports a surge protection of a maximum of 40 KA at the AC power input port and 10
KA/20 KA at the DC power output port.
The AC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both on the top of
and beside a BTS3900A. In this case, an attachment plate is required and no footprint is required.
The DC OMB Ver.C can operate in a temperature ranging from of -33ºC and +50ºC.
Customer side
Power backup is not supported.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless Base
Stations.

Page 42 Back
HUAWEI TECHNOLOGIES CO., LTD.
DBS Senario

Existing
transmission
equipment
CPRI optical

HUAWEI TECHNOLOGIES CO., LTD. Page 43


DBS Structure

HUAWEI TECHNOLOGIES CO., LTD. Page 44


CPRI Cable

Branch of Cable

Appearance of Figure Connected to Equipment

HUAWEI TECHNOLOGIES CO., LTD. Page 45


CPRI Cable
Single mode/Multi-mode Length Length of branch Be used Connect to Connector Cores
Multi-mode 5m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 10m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 20m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 30m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 40m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 50m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 60m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 80m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 100m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 120m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Multi-mode 150m 0.03m/0.34m CPRI BBU-RRU DLC/PC-DLC/PC 2
Single mode 5m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2SC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2SC/UPC 2
Single mode 10m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2LC/UPC 2
Single mode 20m 0.34m/0.8m CPRI/Iub BBU-ODF DLC/UPC-2LC/UPC 2
Single mode 5m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 20m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 30m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 50m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2FC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2SC/UPC 2
Single mode 10m 0.03m/0.8m CPRI RRU-ODF DLC/UPC-2LC/UPC 2
Single mode 10m 0.03m/0.03m CPRI RRU-RRU DLC/UPC-DLC/UPC 2
Multi-mode 10m 0.03m/0.03m CPRI RRU-RRU DLC/UPC-DLC/UPC 2

HUAWEI TECHNOLOGIES CO., LTD. Page 46


Existing Transmission SmartAXOT928G-D

HUAWEI TECHNOLOGIES CO., LTD. Page 47


RRU3936
RRU dimensions Ports on the RRU panels

RTN(+) / NEG(-) -- Power supply socket


CPRI0/1-- Optical/electrical port 0, connected to the BBU
(2) ANT_TX/RXA TX/RX port A-- supporting RET signal transmission
ANT_RXB RX-- port B

HUAWEI TECHNOLOGIES CO., LTD. Page 48


RRU installation on pole

One RRUs installed on a pole Two RRUs installed on a pole Three RRUs installed on a pole If on ground

HUAWEI TECHNOLOGIES CO., LTD.


RRU installation on wall

RRU installed on the wall

HUAWEI TECHNOLOGIES CO., LTD.


RRU installation inside shelter

Installing RRUs on the lower level-1 Installing RRUs on the lower level-2
Indoor IFS06 Indoor IFS06

HUAWEI TECHNOLOGIES CO., LTD.


RRU 3936 DC RRU3936 Multi-mode 900MHz EGSM RRU3826

Port Connector Quantity Function Item Specifications


RF port DIN 2 Connects to an antenna Dimensions (H x 400 mm x 240 mm x 160 mm (with the
Common public DLC 2 Connects to the baseband unit W x D) housing)
radio interface (BBU3900)
(CPRI) port 400 mm x 220 mm x 140 mm (without
the housing)
Power supply socket Easy power 1 Receives –48 V DC power
receptacle (pressfit
type) Weight 15 kg (with the housing)
RET port DB9 1 Connects to a remote control 13.5 kg (without the housing)
unit (RCU)

Item Specifications

Input power –48 V DC; voltage range: –36 V DC to –57 V DC


The RRU3936 supports AC applications after being configured with an AC/DC power module. For details, see the AC/DC Power
Module User Guide.

HUAWEI TECHNOLOGIES CO., LTD. Page 52


Jumper Connector Type
Types of connectors for jumpers

HUAWEI TECHNOLOGIES CO., LTD. Page 53


Jumper Connector Type
Difference between the male connector and female connector

HUAWEI TECHNOLOGIES CO., LTD. Page 54


Jumper Connector Type
Difference between the DIN connector and N connector

HUAWEI TECHNOLOGIES CO., LTD. Page 55


Optical Connector and Flange
SC optical connector and flange

HUAWEI TECHNOLOGIES CO., LTD. Page 56


Optical Connector and Flange
LC optical connector and flange

FC optical connector and flange

HUAWEI TECHNOLOGIES CO., LTD. Page 57