You are on page 1of 2

DATACENTRE E-MEDICAL INDUSTRY

Multi TRANSPORT EMERGENCY

Sentry
30-200 kVA
6
VFI
TYPE

ONLINE Tower

3:3 30-200 kVA

USB SmartGrid
plug ready

Supercaps Energy Service


UPS share 1st start

HIGHLIGHTS

• Complete range The Multi Sentry series is ideal for It has a fully controlled IGBT rectier to
protecting data centres and minimize the impact on the grid. It is
30-200 kVA controlled by a DSP (Digital Signal Processor)
telecommunications systems, IT networks
and critical systems in general, where the microprocessor, to provide maximum
• Small footprint protection to the powered loads with no
risks connected with poor energy supply can
compromise the continuity of activities and impact on downstream systems, and
•High efficiency up to services. optimised energy savings.
96,5% The Multi Sentry series is available in Zero impact source
30-40-60-80-100-125-160-200 kVA models Multi Sentry solves installation problems in
• Zero impact source with three-phase input and output and systems where the power supply has limited
on-line double conversion technology in power available, where the UPS is supported
• Flexibility of use accordance with VFI-SS-111 classification (as by a generator or where there are
set out in standard IEC EN 62040-3). compatibility problems with loads that
• Advanced Multi Sentry is designed and built using generate harmonic currents; Multi Sentry
communications state-of-the-art technology and components. has a zero impact on its power source.
MODELS MST 30 BAT MST 40 BAT MST 60 MST 80 MST 100 MST 125 MST 160 MST 200

INPUT
Nominal voltage 380-400-415 Vac three-phase +N
Nominal frequency 50/60 Hz
Voltage tolerance 400 ± 20% at 100% load*
Frequency tolerance 40 - 72 Hz
Power factor at full load 0,99
Current distortion at 100% load THDI ≤ 3% THDI ≤ 2,5%
BYPASS
Bypass Voltage range from 180V (adjustable 180-200) to 264V (adjustable 250-264V)

Nominal Frequency 50-60 Hz


Bypass input frequency range ±5% (adjustable from 0.25 to 10%)
OUTPUT
Nominal power (kVA) 30 40 60 80 100 125 160 200
Active power (kW) 27 36 54 72 90 112,5 160 200
Power factor 0,9 1
Number of phases 3+N
Nominal voltage 380-400-415 Vac three-phase + N (selectable)
Static variation ± 1%
Dynamic variation ± 3%
Crest factor 3 : 1 Ipeak/Irms
Voltage distortion ≤ 1% with linear load / ≤ 3% with non-linear load
Frequency 50/60 Hz
Frequency stability during
0,01%
battery operation
BATTERIES
Type VRLA AGM/GEL/NiCd/Li-ion/Supercaps
Recharge time 6 hours
Temperature compensation - 0.5V / °C

INFO FOR INSTALLATION


Weight without batteries (kg)
135 145 190 200 220 250 450 460
(MCT/MST)
650 x 840 x
Dimensions (WxDxH) (mm) 440 x 850 x 1320 500 x 850 x 1600 850 x 1050 x 1900
1600
Communications 3 slots for communications interface / USB / RS232
Operating temperature 0 °C / +40 °C
Relative humidity 90% non-condensing
Colour Dark grey RAL 7016
Noise level at 1 m [dBA±2]
< 40 dBA < 63 dBA < 70 dBA
(Smart Active)
IP rating IP20 (Others on request)
Smart Active efficiency up to 99% (On-line mode up to 96.5%
European Directives: L V 2006/95/CE low voltage Directive
EMC 2004/108/CE electromagnetic compatibility Directive
Standards
Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2
Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111
Moving the UPS castors (30 - 200 kVA)
* BAT
Up to -40% at lesser loads Also available with internal batteries

Riello Power India Pvt Ltd.


Corporate office – 318, 3rd floor, Time Tower, MG Road, Gurugram – 122002 BRANCHES ACROSS INDIA: Delhi I Haryana I Punjab I
Tel:- +91-124-4727134 Uttarakhand I Madhya Pradesh I Andhra Pradesh I Assam I
Factory – Plot No.: 213A, Sector 4, IMT Manesar, Gurugram – 122050 Bihar I Odisha I West Bengal I Uttar Pradesh I Rajasthan I
Tel:- +91-124-2975498 Gujarat I Maharashtra I Karnataka I Tamil Nadu I Kerala
Website : www.riello-ups.in | Email : ups@riello-power.com