Professional Documents
Culture Documents
Rental Power
70 kW
U.S EPA Tier IV Emissions
power.cummins.com
©2018 Cummins Inc. | NAS-6311 (09/18)
Engine Specifications
Engine model QSB5-G11
Alternator data sheet UCI (208/240/480)
Tier rating Tier IV
Design 4 cycle, In-Line, turbocharged and after-cooled
Bore 107 mm (4.21 in.)
Stroke 124.0 mm (4.88 in.)
Displacement 4.5 liters (274.6 in3)
Cylinder block Cast iron, In-Line 4 cylinder
Battery capacity 2 x 760 cca
Battery charging alternator 70 amps
Starting voltage 24 volt, negative ground
Fuel system Direct injection HPCR system
Fuel filter Dual Spin on fuel filter with water separator
Air cleaner type 2-stage, dry replaceable element with dust ejector
Lube oil filter type(s) Single spin-on, full flow
Standard cooling system 120 °F (49 °C) ambient radiator
Alternator Specifications
Design Brushless, 4 pole, drip proof revolving field
Stator Double layer concentric, 2/3 winding pitch
Rotor Singe bearing, flexible disc
Insulation system Class H per NEMA MG1-1.65 (208/240/480 VAC)
Standard temperature rise 125/40 ºC prime (208/480 VAC)
Exciter type PMG (permanent magnet generator)
Phase rotation A (U), B (V), C (W)
Alternator cooling Direct drive centrifugal blower fan
AC waveform total harmonic distortion < 1.5% no load, < 5% non-distorting balance linear load
Telephone influence factor (TIF) < 50 per NEMA MG1-22.43
Telephone harmonic factor (THF) < 2%
Power Capability Specifications (Assume power factor = 0.80 for 3 phase amps)
Standby rating
240 V, 1 phase 208 V, 3 phase 480 V, 3 phase 240 V, 3 phase 400 V, 3 phase
Amps 60Hz Amps 60Hz Amps 60Hz Amps 60Hz Amps 50Hz
C70D2RE 195 243 105 210 114
power.cummins.com
©2018 Cummins Inc. | NAS-6311 (09/18)
Engine data
PowerCommand 3.3 Control System • DC voltage
• Lube oil pressure
• Coolant temperature
• Comprehensive FAE data (where applicable)
Other data
• Fault history
• Data logging and fault simulation (requires InPower)
power.cummins.com
©2018 Cummins Inc. | NAS-6311 (09/18)
Ratings Definitions
Standby:
Applicable for supplying emergency power for the duration of
normal power interruption. No sustained overload capability is
available for this rating. (Equivalent to Fuel Stop Power in
accordance with ISO3046, AS2789, DIN6271 and BS5514). B
Nominally rated.
A
Dimensions
Dim “A” Dim “B” Dim “C” Weight w/o fuel Weight with fuel Fuel capacity
Model mm (in.) mm (in.) mm (in.) kg (lbs.) ** kg (lbs.) ** liters (gal)*
C70D2RE 3063 (121) 1262 (50) 1953 (77) 2300 (5070) 3080 (6790) 495 (131)
With trailer 4798 (189) 2106 (83) 2444 (96) 2980 (6570) 3761 (8292) 495 (131)
* Onboard DEF capacity is sized for 24 hours of operation at 15 gallons
** Weights are CAD determined & within +/- 2%
Fuel Consumption
Standby Prime
Hours of
60 Hz Ratings, kW (kVA) 70 (87) 63 (78) operation
Load ¼ ½ ¾ Full ¼ ½ ¾ Full 75% PRP
US Gal/hr. 2.3 4.0 5.9 8.0 2.1 3.8 5.3 7.2 27
L/hr. 8.7 15.1 22.3 30.3 7.9 14.4 20.1 27.3 27
Note: DEF consumption less than 4% of fuel consumption
Trailer Information
Model Tire size Tire type Load range Number of tires Lug pattern
per trailer
C70D2RE 225/75-R15 Radial 2535 lbs. - each 4 8 hole
Certifications
These generator sets are certified to following standards:
North America
1400 73rd Avenue N.E.
Minneapolis, MN 55432
USA