You are on page 1of 1
REGISTERED ELECTRICAL ENGINEERS Pre-Board Examination Sunday, August 15, 2010 8:00 a.m, ~ 12:00 nin, LECTRICAL ENGINEERING PROFESSIONAL SUBJECTS 40. What is the minimum value of the capacitor needed to obtain resonance with a 300 pH coil to frequencies between 500 and 1,500 KHZ? ‘A. 37.6 UF 8.37'6 pF 6.33.9 pF D.33.9pF 41.A completely transposed 60 HZ three-phase line has flat horizontal phase spacing with 19 m between adjacent conductors. The conductors are 1,880,000 cmil ACSR with 54/3 stranding and with GMR of 0.0520 ft. Line length is 200 km. Determine the line inductive reactance in ohms per phase. A, 50.5 B. 101 C151 D. 202 42. A hydraulic turbine receives water from a reservoir at an elevation of 100 meters above it. What is the minimum water flow in kg per second to produce a steady turbine output of 50 MW? A, 50,247 B.50,672 C. 50,968 D. 50,465, 43. A 100 kVA transformer is connected to the suppiy line 24 hrs a day. In 6 hrs it delivers 90 kW at 0.9 B.t; for 4 hrs it supplies 25 KW at 0.5 pif. and for the rest of the day it operates without load, Its core loss at rated voltage is 1,000 watts and its copper loss with ful-load current is 1,680 watts. What is the all-day efficiency of this transformer? A. 96.7% B. 20.7% ©. 92.7% D. 94.7% 44. The initial rate of current rise in an RL circuit is 300 amp per sec when 120 volts is suddenly impressed. What is the inductance of the circuit? A.36H B.25H C.04H D.025H 45, Which of the following common electronic components is not found in IOs? A. Induetors ©. Diodes B. Resistors D. Low capacitance capacitors 46. A 220 volts single-phase induction motor draws current of 10 amperes at 0.75 pf. A capacitor of 50 HF is connected in order to improve the power factor. What is the new power factor? A. 0.95 lagging B. 0.95 leading C.0.886 lagging. 0.866 leading 47. What is the force required to separate two surfaces with contact area of 150 sq. cm when the flux density is 2 Tesla normal to the surfaces? A. 10,100 N B. 15,800 N ©, 23,900 N D. 35,050 N 48. Ata 415 kV substation the PT ratio is 1000 and the CT ratio is 1200/5. The potential going into the: wattmeter is 115 volts. What is the MW indicated when the wattmeter reads 800 watts? A. 150 MW B. 192 MW C. 15 MW 0. 19.2MW 49. What is the total flux emitted by a lamp having an intensity of 50 candetas? A314 im B. 1,256 im ©, 942 im D, 628 Im 50. A 4-pole lap connected de motor draws an armature current of 100 amps at 220 volts. The motor hhas 864 conductors and its armature resistance is 0.2 Q. Calculate the torque developed in N-m if the flux per pole is 0.05 Wb. A145 B. 390 ©. 467 D. 688 “END SUBMIT THIS TEST QUESTION SET TOGETHER WITH THE ANSWER SHEET TO YOUR WATCHERS, BRINGING THE TEST QUESTION SET OUT OF THE ROOM WILL BE A GROUND FOR DYSCIPLINARY ACTION

You might also like