INTRODUCTION ........................................................................... 1
Revision History ...................................................................... 1
List of Changes ...................................................................... 1
Trademark Information ................................................................. 1
Admonishments ...................................................................... 2
FCC Compliance Statement .............................................................. 2
Certification: UL/ETL/CSA Listed ........................................................... 2
1 BUILT-IN LIGHTNING PROTECTION ......................................................... 3
2 GROUNDING PROCEDURES .............................................................. 5
2.1 Grounding the MHU .............................................................. 5
2.2 Grounding the Base Unit ........................................................... 6
3 CUSTOMER INFORMATION AND ASSISTANCE .................................................. 8
INTRODUCTION
Installation of a tower top amplifier system requires proper grounding of the entire system,
starting with the tower. Correct grounding provides a path through which an electrical charge
(such as that caused by lightning) can dissipate its energy safely into the earth. Before
installing the SMARTop Tower Top Amplifier system ensure that the tower has been
constructed following appropriate grounding codes and practices. These practices include
using suitable ground rings which tie all grounds to the same point.
Revision History
List of Changes
Trademark Information
ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc.
SMARTop is a registered trademark of ADC Solitra.
Admonishments
Important safety admonishments are used throughout this manual to warn of possible hazards
to persons or equipment. An admonishment identifies a possible hazard and then explains what
may happen if the hazard is not avoided. The admonishments — in the form of Dangers,
Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of
the triangular alert icon (seen below), and are listed in descending order of severity of injury or
damage and likelihood of occurrence.
Danger: Danger is used to indicate the presence of a hazard that will cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Warning: Warning is used to indicate the presence of a hazard that can cause severe personal
injury, death, or substantial property damage if the hazard is not avoided.
Caution: Caution is used to indicate the presence of a hazard that will or can cause minor
personal injury or property damage if the hazard is not avoided.
Class B
SMARTop products comply with Part 15 of the FCC Rules. Operation is subject to the
following two conditions; (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired
operation.
Warning: This equipment generates, uses, and can radiate radio frequency energy and if not
installed and used in accordance with the instruction manual, may cause interference to radio
communications. It has been tested and found to comply with limits for a Class B digital device
pursuant to Subpart A of Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a residential environment. If
interference to TV and radio reception does occur relocate or reorient the antenna of the
affected radio or TV.
This equipment does not exceed Class B limits for radio emission for digital apparatus, set out
in the radio interference regulation of the authorization methods of Industry Canada.
SMARTop products have been tested and found to comply with the requirements of UL 1419.
Page 2
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
Adequate lightning protection is necessary to protect a system against electrical spikes that
may damage sensitive components. The SMARTop Tower Top Amplifier lightning protection
system has been designed to provide the highest quality and durability available in the
marketplace today. The SMARTop Masthead Unit (MHU) and Base Unit (BU) have sturdy
lightning protection built into each unit.
The SMARTop MHU houses a quarter wave lightning arrestor at the Antenna port to protect
against undesired voltage surges from the antenna. The MHU also contains a gas tube
lightning arrestor at the BTS port to shield the unit against high voltage surges from the base
station. The SMARTop MHU body is cast from a solid block of aluminum, allowing heat
from a high voltage surge to dissipate over a broad surface area, further reducing the likelihood
of damage to the system.
The SMARTop Base Unit contains a gas tube lightning arrestor at the MHU port as protection
from surges at the tower. A quarter wave lightning arrestor is also located at the BTS port to
guard the BU from surges within the base station.
The SMARTop MHU and BU have been tested per General Principles IEC-1312-1 Publication
with test levels defined by IEC-1000-4-5. The SMARTop equipment passed these requirements.
Figure 1 is a block diagram of the SMARTop built-in lightning protection and grounding
locations.
Page 3
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
MASTHEAD UNIT
QUARTER WAVE
LIGHTNING
AMU
(OPTIONAL)
PROTECTION
DIRECTIONAL
COUPLER
GROUNDING CABLE
MHU TO SITE GROUND RX
FILTER
TX
RF-
SWITCH
CONTROL BY -PASS
BOARD
LNA1 LNA2
RF-
SWITCH
POWER
SUPPLY
RX TX
FILTER
SURGE
ARRESTOR
BTS ANT
BU/ACU
RF-signals/DC-feed
Base
Station
SURGE
ARRESTOR
GROUNDING CONTROL
BOARD
CABLE TO SITE BASE
GROUND UNIT
POWER
SUPPLY QUARTER WAVE
LIGHTNING
PROTECTION
BTS RF-connection
Page 4
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
2 GROUNDING PROCEDURES
Proper grounding of the SMARTop MHU and BU is important to protect the system against
voltage surges. A grounding kit is provided for both the MHU and BU, including a grounding
cable, M8 screw(s) and star washers for each unit (see Figure 2).
To ground the MHU attach one end of the supplied grounding cable to the MHU and the other
end to site ground. Figure 3 shows the proper assembly sequence.
Note: The MHU may have two screw holes for grounding. In this case, a double-hole
lug grounding cable is provided. Repeat steps 1-4 for the second grounding screw.
1. Place a star washer (supplied) over the screw hole located on the side of the MHU.
2. Align the one-hole compression lug on one end of the grounding cable over the star washer.
3. Place a second star washer (supplied) over the lug.
Page 5
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
4. Insert an M8 screw (supplied), tightening securely until the bottom star washer is slightly
embedded into the body of the MHU. Figure 4 shows the grounding cable properly
assembled to the MHU.
5. If desired, the grounding cable can be trimmed to appropriate length for the specific
installation, and the one-hole compression lug to the site ground connection can be
replaced with a connection preferred by the customer.
6. Connect the free end of the grounding cable into the proper site ground using a reliable
joint. An exothermic joint or weld bond provides the most reliable connection. A nut and
hex-head cap screw with star washers also offers an acceptable connection. If no bare
ground wire is present from site ground, the connection can also be made to the tower. Be
sure the tower surface is free from paint, rust, or other impediments.
To ground the Base Unit attach one end of the supplied grounding cable to the BU and the
other end to site ground. Figure 5 shows the proper assembly sequence.
Page 6
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
Note: The BU may have two screw holes for grounding. In this case, a double-lug
grounding cable is provided. Repeat steps 1-4 for the second grounding screw.
1. Place a star washer (supplied) over the screw hole located on the side of the BU.
2. Align the one-hole compression lug on one end of the grounding cable over the star washer.
3. Insert an M8 screw (supplied), tightening securely until the bottom star washer is slightly
embedded into the body of the BU. Figure 6 shows the grounding cable properly assembled
to the BU.
4. If desired, the grounding cable can be trimmed to appropriate length for the specific
installation, and the one-hole compression lug to the site ground connection can be
replaced with a connection preferred by the customer.
5. Connect the free end of the grounding cable into the proper site ground using a reliable
joint. An exothermic joint or weld bond provides the most reliable connection. A nut and
hex-head cap screw with star washers also offers an acceptable connection. If no bare
ground wire is present from site ground, the connection can also be made to the tower. Be
sure the tower surface is free from paint, rust, or other impediments.
Page 7
© 1999, ADC Telecommunications, Inc.
ADCP-75-104 • Issue 1 • September 1999
The central number for calls originating in the U.S.A. or Canada is 1-800-366-3891. For calls
originating outside the U.S.A. or Canada, dial country code “1” then dial 612-946-3000.
Product information may also be obtained using the ADC web site at www.adc.com or by
writing ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, MN 55440-1101, U.S.A.
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no
event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further
disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of
liability applies to all products, publications and services during and after the warranty period.
This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 3475
(in U.S.A. or Canada) or 612-946-3000 (outside U.S.A. and Canada), or by writing to ADC Telecommunications, Inc., Attn:
Technical Assistance Center, Mail Station #71, P.O. Box 1101, Minneapolis, MN 55440-1101, U.S.A.
Page 8