PARALLEL REDUNDANCY ON-LINE UPS WITH RAGK+1OWER CONFIGURATIONS
OR MISSION CRITICAUUSER
ENnNEe Tec /VAblerex
POWER SOLUTIONSPARALLEL REDUNDANCY ON-LINE UPS
WITH RACK-TOWER CONFIGURATIONS.
‘The Ablerex MSII-RT Parallel Redundancy On-Line UPS, is the perfect solution
{or mission critical users who demand high reliability, availability and
performance for critical electronic equipment and computer loads.
It features double conversion True Ontine Technology, field-proven full Digital
Signal Processor (DSP) and utilises our uniquely patented inverter control
technology. The Ablerex MSII Parallel On-Line UPS is a scalable system which
achieves N + 1 redundancy without any additional parts.
Simple Parallel Installation (No extra PCB require)
install for operation in parallel to increase power capacity or make redundant
system, Simply connect the paralel contra ins through the RJ
the ear panel with CAM-bus and communication is established to all units. The
‘maximum paralel operation configuration is & units.
Full Digital Signal Processor (DSP) Control
le re eee a cease eet cree a ye al
Kinds of leads, Full BP technology also allow
* Programmable Frequency Converter
fe ;rogrartfe UPS bea Freqherc] Cowertarioretferothiz elt trooyh roe keypad en fyurtion
* Easy-to-Set User Personalization
rough the LCD front panel, you can easily change the built-in parameters and
settings of the DSP controllers, such as UPS operation modes voltage
configurations, synchror
buzzer alarm status,
ion frequency windows, bypass voltage tolerance and
«Intelligent Selt-Diagnostics
Through the self-diagnostics inside the DSP, system faults can be pin-pointed rapidly
wich results in faster repair times easier servicing, Simply access the service mode and
check each device step by step, through the results displayed on the LCD display.
+ Smart Fan Controt
The speed of the internally mounted cooling fans ar
ontrolled according to load
percentage to reduce noise levels and energy consumption.
True Double Conversion On-Line Technology
Corrects power disturbances from the utility power and regenerates
clean and safe AC power. The Voltage Frequency Independent (VF!)
‘working mode of the UPS complies with EN60240-3 ,European Directives
System Block Diagram for True-On-Line Technology.
High Input Power Factor and Low Current THD
Provides clean recifier connection othe utlity power, It meets today's industry standords
{0.0.99 at Input Power Factor as well as <5% Current THD.Energy-efficient UPS
The AC to AC efficiency ofthe UPS reaches upto 90% at 50% load and better
at larger loadings. Using the ECO mode, efficiencies of up 1a 97% can be
achieved
LCD/LED Mimic Panel
FS — BHA) An easy-to-read front panel LCD/LED display provides real-time status of all major system parameters
ae | and statuses such as operation modes, AC voltage, frequency, battery voltage, load level, inner
temperature, etc
2X Customer Options Slots
‘The UPS also provides two additional Customer Option Communication stots {MSI 4500
RT come with | slotl in addition tothe standard RS232 port. All communication cards are
designed for easy installation as electrical connections are made through a 26-pin edge
eptional communication cardls) are installed.
nnector. The first RS232 port on the rear panel will remain active, when other
Smart ECO Mode
In ECO operation mode, power is supplied to load via Bypass Utility. It will automatically
transfer to controlled inverter supply instantly without any break, if Bypass Utility is out of
tolerance or unavailable
i-Batt
Automatically manages end of discharge voltage according to load capacity. The i-Batt
function prevents deep-discharge of the built-in battery during a power failure with ultra
low toad conditions.
Cold Start Function
Enables users to turn on the UPS without connecting to the utility
Power Range and Runtime Scalability
‘The Ablerex MSII UPS provides excellent return on investment. The system is fully modular, which allows you to increase
the overall power output, battery runtime and redundancy as your system grows. It is important however that you design
your electrical installation to support your needs,
Communication Capability
‘The UPS is equip with monitoring/shutdown software as standard, The sftware not only allows the contral of the UPS and
its scheduled shutdown when the utility power fails, but also allows the user to
+ Remotely test the major operating functions of the UPS
+ Communicate via SNMP/WEB card
+ Access UPS functions via the WEBStandard matching battery cabinets are availble to extend the |
MU
Space-Saving Tower/Rack Convertible uN fl \
Design WT TTT
Offers a flexible form factor which enables its integration even
UPS runtime easily to several hours.
soem TIM
pebatie aimee ai serene
Ei aok stewie sat oriceslcit rack ereenret
Optional EPO Function
Enables users to perform one-touch emergency shutdown of the UPS remotely via dry contact relay
Optional Maintenance Manual Bypass
ares com mete pee tes ca best ete peerteal peer comes on haere
Duin Manual Bypase Switch is elactriallinterlocked with th inverter to prove safe operation, An Extemal Mantananca
Bypass switchbox is available for complete unit hot swap. (Optional, please check with your dealer)
Optional Galvanic Isolated Transformer
The galvanic isolation transformer not only provides 2 complete isolation
between input and output, but also allow various secondary voltages such as 220/230/240Vae,
208Vac/120Vac and 240Vac/120Vac. This provides an intrinsic safety between input and output
either at normal system mode or at bypass mode. [refer to system block diagram)
IGTM-WOS | Galvani leolation transtormer & Maintenance Bypass Switch | 40x 88 x 580 24g
GTM-WS | Galvanic leolation transformer 260x88 680 akg
RacPDU-230 | Rack Power Distribution Unit 326 x88 x 100 595
Optional External Battery Charger Box (1000Watts / 4Amps)
eer le ere este cocpeae epee te ere ream eter pert eaten
ee charges ig eeectlopeare ea
AC Input Range 100 280Vbe, 45-65He
‘Maximum Power Output T0O0W, continuously
—q CEN Constant Voltage wih Current Limitation
Maximum Parallet Units _Uptodcharges
Protections STteited devcastor Oppo patty Connachon
Mounting Mouniod on the rear ofthe UPS or wall mounted
imensiontwxox 166282 86mm
et Weight 3298Votage
Freevency
Phase Wie
Power Factor
‘current THO
‘ourur
‘pacity
Rated Poner Factor
Wave From
Frequency Stability
Frequency Regulation
Crest Factor
Etficincy (AC to AC, Normal
Eile (AC 0 AC, ECO)
-Autonany [runtime tal al
oc start
‘Quantity
Vatage
Recharge Time
DISPLAY
‘Stauson LED + LED
Readings on LOD
Sel-Dagnostis
PROTECTION
Overond
(vith simulated thermal tripping -T curve
‘Short iret
vernast
Battery Low
Noise Suppression
‘Spike Suppression
‘ALAS
‘edie and Views
TECHNICAL SPECIFICATIONS.
MSII 4500RT MSII 6000RT MSII 10000RT
10-2008 ergopae RES
6-15
Sie Na roid
Ut 0 97010 Uno
£9 100% Line Lo
200/208/20/250240Vac Selectable (208/20¥ac Optional)
Nominal 152%, 8, 1%, 2% oF 3%
Pa
o0nu9/2000 *aon0v5y70000
07 tagging
Sine Wave, Voltage THO <6 no lod to fl oa
0.2% On inverter Free-Running Mose
1-1Ma, 41-3 (programmable by see
mene
3: acceptable
Upto 90%
5-30 mins depending on Load
Sealed Lead Act Maintenance Free
7H or)
Opes
uov4e
‘Horst 9%
ine Mde, Backup Mode, ECO Mode, 8ypass Suply. Batty Low, Battery Bad/Disconnec
versad Transferring with terruption, & UPS Fault
‘nut Vatiage. Input Frequency, Outpt Veltage, Ouput Frequency, Load Percentage, Battery
Vatage & nner Temperature.
‘Upon Power-on & Front Panel Setting
AC Made; <105% conthouey 121% ~ 160% fo 10900
Stoo 20 0 gee ST eed
ype Mode 177%— 167 fr Oe ec ena own
S13a%- Mehra ee shadow SYaNGierO 1 ee stun
‘verter Steh Ot mmasatly
[AC mode Sten to Bypaee
‘Backup made: IPS shuts down ireneey
‘Alarm and Sten Of
Comets with ENE2040-2
Cortes wih EN61000-4-5
ie Fire, Battery Low, Transfert Bypass Syelam Ful CononablerexMSII-RT tecHnicat sPeciFicATiONS
Model MSII 4500RT MSII 6000RT MSII 10000RT
ParsicaL
Dimensions (WH x0} Rack Comiguraton UO yj si|UPS Bey) 488 2) x 80 [UPS medal), 440 139 (3x 580 [LPS module)
Ue BU Bate mot 130 19x80 Bstory mode
Net Weight Age 7g Hl, 8g Baty ein) ls PS aes ee
Optional Extended Battery Bank
38200007 L2pes 120/7AH)
Input & Outpt Connection Horawice
sternal tery Connection Plug & Play
ENVIRONMENT
Operating Temperature we cr
Teperahre Wertirg Thebaltery desig ie is based ona terperatreo 5°: Ambient temperature above this range
‘a reduce battery le
ude 0-200 up te 46, S000m up 18 3540
Hui {90% RH Maxime Non-Condensing
Nese 3039 [at | mete
‘COMPUTER INTERFACE
Intertce Type Standord 85232 interface
Communion Sot {P+ RSZ2 with EPO™, USB with EPO™,RSLBS with EPO, Relay Contact & EPO, SNMPVEB
(Card ete. Opinal
Dimension: 440 15 SU} 640, weight 684g
‘SAFETY CONFORMANCE
‘ual Assurance {SO7001 Ceri Company
Salty Standard ENAZOAO-,ULITTS
EMC Standara ENSZ060-2, ENSI000-3.2,EN6I000-99, FCC Claes A
Marks ce UL
+ 40 17612 875% 098
These card arent sabia to use simultaneous
Spscications subject te change without prior tie.
ENEReTeEcC B2ce
fees power SocuTiONS
‘Auckland - Head Office DESIGNED AND A bl
[Phone v5¢9 72 1203 Fax +04 99702 1204 ENGINEERED BY : VAblerex
|21B Tamdsle Grove, Rosedsle, Auckland 0622 7
[Po aon 10825, Westpark Vilage, aveland G88 iS Sirponion Miresuceete ta
|Welington- Branch Oftice teow Aron tigieay Suter fenewinaeta morte
‘Phone o4 49996329, Fex-+04 4999 6979 ini a8 Seon
Island Bay Wetington 6023 eer ted
havwenete.con info@enertec.co.2 Eh Seesetboe cmap
asi vos worwablerex-ups.com