The lighting should reasonably free from flare, and For toilet and bathroom, a minimum diameter of 15.24
evenly distributed void shadows. cm per 35 cubic meter room volume should be
provided as well.
Intensity of the required illumination inside the
establishment should be maintained at a point about However, windowless bathrooms shall be provided
30 inches above the floor. with mechanical exhaust system that are connected
to the light switch (same witch with light), so that the
There shall be provisions for sufficient lighting fixtures exhaust fan for that toilet or bathroom should be
on open areas that capable of illuminating dark places switched on when the light is switch.
in the establishment, especially at night.
Air conditioner of the room of the establishment shall
The switches of lighting fixtures should be be supplied through air inlets that are arranged and
conveniently located, if possible, near the door. located and equipped so that the personal guests and
visitors are not subjected to air velocities of more than
The level of illumination of other areas not otherwise 1.02 m/sec.
mentioned should be of such intensity that may
required by the local health officer concerned as Requirements For Sound And Vibration
recommended by the sanitary engineer. In Establishments
Ventilation can either be natural or mechanical Anti-vibration mounting shall be utilized for sound and
ventilation, which is effective and suitable for comfort vibration producing equipment.
and safety of clients and personnel. Insulation and absorbing material and equipment
Proper ventilation should be provided in all areas of should be used to minimize excessive sound and
the establishment. vibration, and it should be in accordance to the
occupational health and safety standard.
When natural ventilation is provided, a room intended Air industrial hygiene and Code of Sanitation
for use shall be provided with a window or windows of the Philippines
with a total frame area of opening that is equal to at
least 10 percent of the floor area of the room.
Disabled Persons, including its implementing rules
Safety Requirements In Establishments and regulations.
The health and safety in the working environment Provisions For The Specific Types Of
shall be in accordance with the occupational health Nuisances
and safety standards that are formulated by the
Department of Labor and Employment, and following
A. Public or Private Premises maintained and used in a
the Code of Sanitation of the Philippines.
manner that is injurious to health
Emergency telephone and telephone number of
ambulance services and doctors and hospitals shall 1. No public or private place shall be used and
be conspicuously posted in the premises of the maintained as a disposal site of refuse or any
establishment. other noxious wastes, unless the site has been
designated for such purpose with the approval of
The establishment shall provide the prescribed the local health officer, or any concerned
medicines, readily accessible first aid kit equipment regulatory agencies.
and supplies, and medical staffs according to the
number of workers 2. By-products like rust-holes and other similar
E.g. There should be 1 occupational health particles shall not be stored or dumped in an open
physician, 1 dentist, 1 occupational health or exposed area without any covering or
nurse, 1 first aider per 200 to 600 workers. protective material which shall prevent such by-
products from scattering or being blown away by
There should be personal protective equipment that the wind.
is appropriate for the type and nature of the work.
3. There shall be no structure, material, equipment,
These PPES should be provided to the
machinery, or vehicles abutting unto public street
employees by the operator of the
or sidewalks that affects and obstructs the
establishment.
convenient passage of traffic and passersby
The fire protection system and safety instruction Streets used as parking for vehicle or for
program of the establishment shall be in accordance any other purpose shall be subjected to
with the Fire Code of the Philippines. the approval of the local health authority,
under existing local regulations and
There should be regular fire drills and earthquake ordinances.
drills that should be conducted in the establishment,
at least twice a year. 4. Any structure or parts that were decayed,
damaged by fire or termites, or declared as
condemned, and to which the assessment of the
Electrical Designs and Equipment local health officer that structural integrity is
Specifications in Establishments already questionable - then it shall constitute a
hazard to public health and safety, and so it shall
be demolished within such reasonable time as
All electrical systems should conform to the
the local health officer may order after due written
Philippines Electrical Code, as adapted by the Board
notification of the owner or operator of that
of Electrical Engineering, pursuant to the R.A No.184,
establishment.
otherwise known as the Electrical Engineering Law.
In the case of machineries, equipment or
other structures or materials placed
Mechanical designs, equipment specifications,
unprotected or unguarded, are
installation, and all mechanical systems shall conform
unsanitary, situated or operated in a
to the Philippine Mechanical Engineering Code.
public or private premises but they
constitute nuisance – all of these should
Public or private premises or buildings that are A sanitary requirement for the segregation and
constructed, altered, or operated in violation of storage or collection, transport and even final
the Code of Sanitation of the Philippines and the disposition of the refuse shall be in compliance with
Building Code of the Philippines (Presidential the Refuse Disposal of PD856
Decree No. 1096), the Civil Code of the
Philippines, and other existing laws and local 1. Storing and drying of manure shall be made at a
ordinances, shall be declared as nuisance and minimum distance of 500meters away from the
the local health officer shall have the authority or residential, commercial or industrial area or as
the power to order in writing for the operator to approved by the local health officer considering
correct and remove the said nuisance within such that objectionable odors emitted by the
reasonable time as the local health officer may establishment shall not cause nuisance to the
order. people residing to the area.
C. Breeding places and harborage of vermin 2. Noxious matter or waste are matter that are
Important in establishments that are considered discharged greatly in the streets. There shall be
as nuisance and offensive traits or occupation. no noxious matter of harmful substance that shall
be disposed of into streets, roads or alleys,
1. The owner or operator of the said establishment bodies of water, or any pathways or place that is
shall be responsible for the control of vermin and not approved by the local health officer or rather
its breeding places within his / her establishment concerned regulatory agencies as disposal sites
or premises. for this matter.
5. All domestic animals like those that are kept as pets or Boar (pre) 1.858sqm
those that are used in the livestock industry and for other Sow (pre) 1.858sqm
purposes shall be under the effective control of its owner Gilts (pre) 1.580sqm
or operator of the establishment. Young sow 4.460sqm
Mature sow 5.948sqm
Minimum space requirement for growing or
finisher house (per swine head):
Fattener 6sqm