TABLE D - TYPE OF LAY-UPS FOR DIAMETER AND PRESSURE RATING

See Table E for lay-up details


PRESSURE RATING

DIA. GRAVITY 50 psi 100 psi 150 psi


2" 50 mm TYPE 1 TYPE 1 TYPE 1 TYPE 1
3" 75 TYPE 1 TYPE 1 TYPE 1 TYPE 1
4" 100 TYPE 1 TYPE 1 TYPE 1 TYPE 1

6" 150 TYPE 1 TYPE 1 TYPE 1 + 2 TYPE 1 + 2


8" 200 TYPE 2 TYPE 1 + 2 TYPE 1 + 2 TYPE 1 + 2
10" 250 TYPE 2 TYPE 1 + 2 TYPE 2 + 3 TYPE 2 + 3

12" 300 TYPE 2 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3


14" 350 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3
16" 400 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3

18" 450 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3


20" 500 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3
22" 550 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3 TYPE 1 + 2 + 3

24" 600 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3 TYPE 1 + 2 + 3


30" 750 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3 TYPE 1 + 2 + 3*
36" 900 TYPE 2 + 3 TYPE 2 + 3 TYPE 1 + 2 + 3 T 1 + 2 + 3 + 4*

42" 1050 TYPE 2 + 3 TYPE 2 + 3 TYPE 2 + 3 + 4* T 2 + 3 + 3 + 4*


48" 1200 TYPE 2 + 3 TYPE 1 + 2 + 3 TYPE 2 + 3 + 4* T 2 + 3 + 3 + 3 + 4*
54" REV. 1 1400 TYPE 2 + 3

Note: Joints marked thus*, shall be designed by the fabricator to suit the particular installation.

Joint design shall be approved by the Engineer.

If expert guidance is not available, then the combinations marked thus* are the minimum
requirements