You are on page 1of 2

Company name: PT Andalan Inti Rekatama

Created by: Tomo


Phone: 081298376427
Email: sriutomo@ptair.co.id
Date: 26/07/2019
H CRN 45-2-2, 3*400 V, 50Hz eta
Description Value [psi] [%]
Q = 35 m³/h
General information: H = 45 psi
Product name: CRN 45-2-2 A-F-A-E-HQQE 65 n = 93 % (46.5Hz) / 2739 rpm
Pumped liquid = Drinking water
Product No: On request 60
100 % Density = 998.2 kg/m³
EAN number: On request
55
Technical: 93 %
Pump speed on which pump data are based: 2919 rpm 50 100
Actual calculated flow: 35 m³/h
45 90
Rated flow: 45 m³/h
Resulting head of the pump: 45 psi 40 80

Head max: 58.78 psi 35 70


Stages: 2
30 60
Impellers: 2
Number of reduced-diameter impellers: 2 25 50
Low NPSH: N
20 40
Pump orientation: Vertical
Shaft seal arrangement: Single 15 30

Code for shaft seal: HQQE 10 20


Approvals on nameplate: CE, EAC,ACS
5 10
Curve tolerance: ISO9906:2012 3B Eta pump = 75.3 %
Eta pump+motor+freq.converter = 65.6 %
Pump version: A 0 0
0 5 10 15 20 25 30 35 40 45 50 55 Q [m³/h]
Model: B
P NPSH
Materials: [kW] [psi]
Base: Stainless steel P1 (motor+freq.converter)
EN 1.4408 6 30

AISI 316 5 P2 25
Impeller: Stainless steel
4 20
EN 1.4401
AISI 316 3 15
Material code: A
2 10
Code for rubber: E
P1 (motor+freq.converter) = 4.601 kW
Bearing: SIC 1 5
P2 = 4.005 kW
NPSH = 2.65 psi
Support bearing: Graflon 80
190
4
x
14

4 X G 1/2

G 1/2
18
x
8
331
266
365
251
0 0
300

Installation:
220

134

134
Maximum ambient temperature: 333 K
220
Maximum operating pressure: 16 bar
Max pressure at stated temp: 16 bar / 120 °C
16 bar / -40 °C
Type of connection: DIN
391

Size of inlet connection: DN 80


Size of outlet connection: DN 80
Pressure rating for pipe connection: PN 40 300

Flange size for motor: FF265


G 1/2 G 1/2
Connect code: F
Liquid:
639

8 x 18
4 X G 1/2
Pumped liquid: Drinking water
Liquid temperature range: 233 .. 393 K
160
200
45
140

Density at selected liquid temperature: 998.2 kg/m³


Electrical data: 190
251
80
266
4 x 14
365 331
Motor standard: IEC
Motor type: 132SC
IE Efficiency class: IE3
Rated power - P2: 5.5 kW
Power (P2) required by pump: 5.5 kW
+T +T +T

Mains frequency: 50 Hz
Rated voltage: 3 x 380-415D V
Rated current: 11 A
CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY
IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE

Starting current: 1080-1180 % TO AMPLIFIER


RELAY
L1 L2 L3
Cos phi - power factor: 0.87-0.82
THERMISTORS PTC ACCORDING TO DIN 44082

Rated speed: 2920-2940 rpm


Efficiency: IE3 89,2%
+T +T +T
Motor efficiency at full load: 89.2 %
Motor efficiency at 3/4 load: 90.0 %
Motor efficiency at 1/2 load: 89.6 %
Number of poles: 2 TO AMPLIFIER
RELAY

Enclosure class (IEC 34-5): 55 Dust/Jetting L1 L2 L3


Company name: PT Andalan Inti Rekatama
Created by: Tomo
Phone: 081298376427
Email: sriutomo@ptair.co.id
Date: 26/07/2019
Description Value
Insulation class (IEC 85): F
Motor protec: PTC
Motor No: 85U17417
Controls:
Frequency converter: NONE
Others:
Minimum efficiency index, MEI ≥: 0.70
Net weight: 105 kg
Gross weight: 128 kg
Shipping volume: 0.309 m³
Danish VVS No.: 385917022

You might also like