Date 11.04.2019
Company Parkview Constructions
From Daniel Ostrowski
Regarding Mix Submission ~ McAuley Place Wahroonga
Please find attached our mix design proposal for the above project. The mixes have been designed to meet
the requirements of the Australian Standard AS1379 (Specification and supply of concrete) and Boral’s
quality requirements.
Boral Concrete does not guarantee 24 hour strength of concrete test specimens. As a rough guide the 24
hour strength of the concrete designs submitted is likely to be between 3 and 13MPa depending on the
weather conditions in those first 24 hours. The test specimens lose significantly more heat than the slab in
colder weather due to the higher surface area to volume ratio. In colder temperatures consideration
should be given to delaying initial stress,
{In the absence of any formal rejection of this submission it is assumed that all mixes described within it are
approved for supply to the above project once an order has been placed for that concrete.
‘The mix designs are confidential and may not be reproduced without the written consent of Boral Concrete,
Boral Concrete reserves the right to modify mix designs to maintain consistent quality. Please contact me
‘0n 0401 894 915 should you have any queries,
Notes —
* -Notall admixtures, cements or aggregates may be present in all mixes
Regards
Danie! Ostrowski
Technical Specialist - Concrete
Boral Construction Materials NSW/ACT
The information contained m this mk submission is of confidential nature and is sole use le for communication purposes
between the sender and addressee. Your respect of this confidentiality is appreciated. If you have received this submission in
error, please notity the sender on the above telephone number,&
ot
Cement Type *
Boral Cement SL Cement
Boral Cement Enviroment GGBFS
Boral Cement Flyash
Coarse Aggregate *
20mm (Peppertree/Peats)
10mm (Peppertree/Peats)
Fine Aggregates *
Coarse Sand ( Peppertree/Peats)
Fine Sand (Dunmore/Stockton )
‘Admixtures *
Superplasticiser (PCHRF2 ex Sika)
Set Retarder (Retarder N ex Sika)
Water Reducer (Plastiment 10 ex SIKA)
Visco flow (12 Slump Keeper ex Sika)
ADE Renew
D.0a
Brow
Grade N32 N32,
BORAL Product Code 137949 137947
Description 32MPa 20mm 32MPa 10mm
Cementitious Content 355kg/m3 360kg/m3
Water/Cementitious Ratio 0.48 0.49
Nominal Slump (mm) 90 90
Grade N40, N40
BORAL Product Code 137956 137954
Description 40 MPa 20mm 40 MPa 10mm
Cementitious Content 420ke/m3_ 430ke/m3
Water/Cementitious Ratio 0.42 041
Nominal Slump (mm) 90 90
Grade NSO NSO
BORAL Product Code 137963 137961
Description 50MPa 20mm 50MPa 10mm
Cementitious Content S10kg/m3 S15kg/m3
Water/Cementitious Ratio 0.35 0.36
Nominal Slump (mm) 90 90at
Grade $40) S40
BORAL Product Code 227669 226289
Description 40 MPa 10mm Dincel 40 MPa 10mm _AFS Wall
‘Cementitious Content ‘420ke/m3 440ke/m3
Water/Cementitious Ratio 0.43 0.41
Nominal Slump (mm) 150 130
Grade 40 $40
BORAL Product Code 204693 212807
Description 40 MPa 20mm Post Tension 40 MPa 10mm Post Tension
22@ 4 Days 10% Ash 22@ 4 Days 10% Ash
Cementitious Content 390kg/m3. ‘405ke/m3
Water/Cementitious Ratio 0.46 0.44
Nominal Slump (mm) 30 90
Grade 40 $40
BORAL Product Code 204694 212808
Description 40 MPa 20mm Post Tension 40 MPa 1Omm Post Tension
22@ 5 Days 10% Ash 22@ 5 Days 10% Ash
Cementitious Content, '380ke/m3, 395kg/m3
Water/Cementitious Ratio 0.47 0.45
‘Nominal Slump (mm) 90. 90.
Grade 365
BORAL Product Code 161151
Description 65MPa 10mm High Slump
Cementitious Content 610kg/m3,
Water/Cementitious Ratio 0.31
‘Nominal Slump (mm) 150