Medium Aggregation Node
MINI-LINK 6693

➢ Medium size 1.5 RU aggregation node for up to 8 radio links


▪ Available topologies : 1+0 / 1+1 / 2+0 / 2+2 / 4+0
➢ 1 slot “S6” for Node processor unit NPU with NPU 1002 or NPU 1003
▪ 2x1G/10G Ethernet interfaces
▪ 3x1G Ethernet interfaces
▪ 4 E1 interface for NPU 1003 only
➢ 4 slots “S1,S2,S4&S5” for Modems or interface plug in unit
▪ MMU 1001 or 1002 dual carrier
▪ LTU 1001 with 16E1 interfaces
▪ LTU 1002 with 16E1 or 1xSTM-1 interfaces
➢ 1x Fan Unit FAU 1301 at slot “S0”
➢ 1x Power Filter Unit PFU 1301 at slot “S3” with dual power input for power
redundancy
MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 4
Large aggregation node
MINI-LINK 6692

➢ Large size 3 RU aggregation node for up to 16 radio links


▪ Available topologies : 1+0 / 1+1 / 2+0 / 2+2 / 4+0
➢ 2 slots “S9&S10” for Node processor unit NPU with NPU 1002
▪ 2x1G/10G Ethernet interfaces
▪ 3x1G Ethernet interfaces
▪ NPU redundancy with additional NPU 1002
➢ 8 slots “S1,S2,S5,S6,S7,S8,S11&S12” for Modems or interface plug in unit
▪ MMU 1001 or 1002 dual carrier
▪ LTU 1001 with 16E1 interfaces
▪ LTU 1002 with 16E1 or 1xSTM-1 interfaces
➢ 1x Fan Unit FAU 1201 at slot “S0”
➢ 2x Power Filter Unit PFU 1201 for power redundancy at slots “S3&S4”
MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 5
Switch/node capabilities
NPU 1002 & NPU 1003

NPU 1002

➢ Front Interfaces
▪ 2x RJ 45 100Mbps / 1 Gbps Ethernet ports
▪ 1 x SFP 1Gbps Ethernet port
▪ 2 x SFP/SFP+ 1Gbps or 10Gbps Ethernet ports
▪ 2 MHz sync , Sync Ethernet
▪ User I/O (3 in 3 out)
▪ Local management
➢ DCN
▪ DCN over VLAN or Routed DCN
➢ Fully utilized in MINI-LINK 6692 but can also be positioned in MINI-LINK 6693
➢ Hardware prepared for NPU redundancy in MINI-LINK 6692

NPU 1003

➢ Front Interfaces
▪ 4xE1 front interface
▪ 2x RJ 45 100Mbps / 1 Gbps Ethernet ports
▪ 1 x SFP 1Gbps Ethernet port
▪ 2 x SFP/SFP+ 1Gbps or 10Gbps Ethernet ports
▪ 2 MHz sync , Sync Ethernet
▪ User I/O (2 in 1 out)
▪ Local management
➢ DCN
▪ DCN over VLAN or Routed DCN
➢ Can be positioned in MINI-LINK 6693
MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 6
Interface board
LTU 1001 & LTU 1002

LTU 1001

➢ Interfacing Legacy services natively


➢ 16xE1 front interface
➢ Pre requisite is MINI-LINK 6692/6693
using NPU 1002 or NPU 1003

LTU 1002

➢ 1xSTM-1 front interface for support


of 63xE1
➢ Protection with MSP 1+1 using 2xLTU
1002
➢ 16xE1 front interface
➢ Pre requisite is MINI-LINK 6692/6693
using NPU 1002 or NPU 1003
MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 7
Powerful dual carrier modem
MMU 1001 & MMU 1002
MMU 1001
➢ Single carrier modem
▪ 1+0
▪ 1+1 / 2+0 using two different modems
➢ Support XPIC / HSB / SD topologies
➢ Use MINI-LINK 6363 or RAU2 X
➢ Pre requisite is MINI-LINK 6692/6693
using NPU 1002 or NPU 1003

MMU 1002
➢ Dual carrier modem
▪ 1+0/1+1/2+0/2x1+0
▪ 2+2 / 2x1+1 / 4+0 using two different modems
➢ Support XPIC / HSB / SD topologies
➢ Use MINI-LINK 6363 or RAU2 X
➢ Pre requisite is MINI-LINK 6692/6693
using NPU 1002 or NPU 1003

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 8


MINI-LINK 6600 Comparison
MINI-LINK 6692 MINI-LINK 6693
Height 3U 1.5U

Power supply requirements 32A 25A

Traffic 2×FE/1G RJ45 2×FE/1G RJ45


interfaces 1×FE/1G SFP 1×FE/1G SFP
2×1G/10G SFP+ 2×1G/10G SFP+
Node Processor NPU 1002 NPU 1002
Unit (NPU) or
NPU 1003
Single Carrier MMU 1001 MMU 1001
Modem Unit
(MMU)
Dual Carrier MMU 1002 MMU 1002
Modem Unit
(MMU)
Line Termination LTU 1001 LTU 1001
Unit (LTU) for
E1/DS1
Line Termination LTU 1002 LTU 1002
Unit (LTU) for E1
and STM-1

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 9


Power requirements for MINI-LINK 6693

➢ An input DC Voltage of –48 V required to power up MINI-LINK 6693 nodes


➢ Rate of each fuse or CB must be 25A

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 10


Power requirements for MINI-LINK 6692

➢ An input DC Voltage of –48 V required to power up MINI-LINK 6692 nodes


➢ Rate of each fuse or CB must be 32A

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 11


Cooling and Spacing requirements

➢ MINI-LINK 6600 nodes can be installed inside


19” rack according to their dimensions
➢ Air-cooling is provided by the FAN UNIT . The
air enters at the right side of the enclosure and
exits at the left side of the enclosure. The air
inlet and outlet must not be blocked in any
way.
➢ Distance between air inlet and outlet to wall
must be ≥ 20 mm.
➢ MINI-LINK 6693 height is 1.5U while MINI-LINK
6692 height is 3U.
➢ All empty slots must be covered with dummy
units.
➢ Insufficient cooling may shorten the useful life
of the equipment. Be sure to always keep the
recommended distance to any wall.
➢ Environmental conditions must comply with
cooling specifications.

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 12


Grounding of MINI-LINK 6600 NODES

➢ Earthing cable connected and tighten to


screw in left side of Mini-link node.
➢ The other end of the earthing cable must
be connected to one of standard
grounding points according to Orange
acceptance criteria.

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 13


Mapping between Traffic Node and MINI-LINK 6600 modules

TRAFFIC NODE MINI-LINK 6600


Node Processor NPU3 B/C/D for TN 2P/6P NPU 1002 for all
Unit (NPU) NPU1 C/D for TN20P NPU 1003 for 6693
Modem Unit MMU4A MMU 1001
(MMU) MMU 1002
Line Termination LTU3 12/1 LTU 1001
Unit (LTU) for LTU 16/1 LTU 1002
E1/DS1 LTU 32/1
LTU B 32/1
Line Termination LTU 155 e/o LTU 1002
Unit (LTU) for STM-1 LTU2 155 e/o
Power Filter Unit PFU1 for TN20P PFU 1101 for 6691
(PFU) PFU3 B/C for TN6P PFU 1201 for 6692
PFU 1301 for 6693
Fan Unit FAU1 for TN20P FAU 1101 for 6691
(FAU) FAU4 /FAU2 B for TN2P FAU 1201 for 6692
FAU2 /FAU2 B for TN6P FAU 1301 for 6693
Button on module board BR. (Board Removal) Maintenance Button
Indication LED Fault (red) Fault (red)
Power (green) Operational (green)
BR (yellow) Maintenance (blue)
MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 14
Software part
Login into Mini-link node

• MINI-LINK 6600 nodes has two different interfaces for local


access through node processor unit.

1. Mini-Usb interface with default IP “10.0.0.1” and prerequisites are :


I. Usb to Mini-Usb physical cable
II. laptop with proper OS
III. CLI and GUI tools ( Browser or latest version of MINI-LINK CRAFT 18.Q4 )
2. Ethernet LAN interface with default IP “192.168.0.1” & default LAN
interface “TR:5” and can be changed during Basic DCN configurations
to match operator DCN IP plan and prerequisites are :
I. Ethernet physical cable with RJ45 connectors
II. laptop with proper OS
III. CLI and GUI tools ( Browser or latest version of MINI-LINK CRAFT 18.Q4 )

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 15


Software part
Login into Mini-link node
➢ Logon Window
▪ In case of local authentication, use one of the following:
control_user
admin_user
➢ Password : ericsson with small letters
➢ Sign in — Button for accessing the MINI-LINK Node GUI desktop

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 16


Software part
Login into Mini-link node

User Interface Overview


A : Management tree — Shows the
tree of managed objects
B : Main area — Contains the main
area for working with the NE.
C : Notification list — Displays alarm
notifications
D : Title bar — Contains the current
page title and buttons for commonly
used tasks.
E : Licenses counter — Displays the
total number of license notifications
in the NE
F : Alarms counter — Displays the
total number of active alarms in the
NE
G : User settings menu — Contains
general user settings and the Log Out
button

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 17


Software part
Radio link configurations

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 18


Software part
Radio link configurations

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 19


Software part
RSL window

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 20


Software part
RSL window

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 21


Software part
Link performance

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 22


Software part
DCN configurations ( Basic NE )

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 23


Software part
DCN configurations ( ospf area )

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 24


Software part
Supervision ping test via cli tool

➢ We have three different cli windows


1. CLI window opened in MINI-LINK CRAFT window
2. Cmd window in START menu in windows OS
3. PuTTY CLI tool and it is recommended

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 25


Software part
Node alarms

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 26


Software part
TDM E1 loop test

MINI-LINK-6600 Introduction | Ahmed Hassaan | 2019-02-26 | Page 27

You might also like