You are on page 1of 3

1490 HERVEY LANE AMS DESIGN

SAN JOSE, CA
AMSDESIGN
2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008

50'-8"
Tell: (415) 254.1606
e-MAIL: office@AMSDesignllp.com

VICINITY MAP: PROJECT CONTACT:


Azadeh Masrour
OWNER: Guillermo Segura
1490 HERVEY LANE., SAN JOSE, CA

DESIGNER: AMS Design

PROPERTY LOCATION / NTS


(415)254-1606
2275 S.BASCOME AVE.#1406,CAMPBELL,CA 95008
AZADEH@AMSDESIGNLLP.COM

STRUCTURAL: AMS Design


(415) 254 -2634
2275 S.BASCOME AVE.#1406,CAMPBELL,CA 95008
ARMIN@AMSDESIGNLLP.COM

T24 & ENERGY: ARASH FIROUZJAEI


(650)353-7784
434 CAMILLE CIR.#13,SAN JOSE, CA 95134

HERVEY's
PROJECT DATA: DRAWING INDEX: RESIDENCE
ASSESSOR'S PARCEL NUMBER: 434-19-004 1490 HERVEY LN.
PROJECT TYPE: REMODELING A-00.01: COVER SHEET /SITE PLAN SAN JOSE, CA
PROJECT LOCATION: 1490 HERVEY LN,San Jose, CA RA-01.01: EXISTING FLOOR PLAN
95125 A-01.01: PROPOSED FLOOR PLAN
A-02.01: PROPOSED ELEVATIONS REVISION TABLE:
ZONING: R-1-8
OCCUPANCY GROUP: R-3/U A-03.01: PROPOSED SECTIONS
REVISION DATE BY
CONSTRUCTION TYPE: V-B E-01.01: ELECTRICAL PLAN
NUMBER OF FLOORS: ONE (1) STORY S1: STRUCTURAL COVER SHEET
FIRE PROTECTION: NOT SPRINKLERED S2: FOUNDATION PLAN
S3: CEILING PLAN
S4: ROOF PLAN SKY
LIGHT

CODE EDITIONS: SD1: STRUCTURAL DETAILS

150'
GB-01: GREEN BUILDING

150'
T-01: TITLE 24 REPORT
CALIFORNIA RESIDENTIAL 2016 EDITION
CALIFORNIA BUILDING 2016 EDITION
CALIFORNIA MECHANICAL 2016 EDITION
CALIFORNIA PLUMBING 2016 EDITION
6'-4"
CALIFORNIA ELECTRICAL 2016 EDITION
CALIFORNIA ENERGY: 2016 EDITION SKY
LIGHT
SKY
LIGHT

CALIFORNIA FIRE: 2016 EDITION


CALIFORNIA GREEN BUILDING: ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GAS GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
ANY OTHER APPLICABLE LOCAL AND STATE LAWS
AND REGULATIONS. GENERAL NOTES: METER
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
5'-1" WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE

GAS
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE

AREA CALCULATION: 1. CONTACT PUBLIC WORKS, FOR DRAINAGE AND FINAL GRADE INSPECTION,
WHICH INCLUDES DRAIN LINES AND ROOF DRAINS/DOWN SPOUTS.
PRECEDING AT HIS OWN RISK.

OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-


DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
LOT AREA: 7800 SF 2. ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
ELEC
METER PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF

GAS
"E" LIVING AREA: 1884 SF 3. CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND INSURING THE AREA
FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.
"E" GARAGE: 220 SF ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY
TOTAL BUILDING: 2104 SF DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
4. THE CONTRACTOR SHALL REVIEW STD. DETAIL 6-4 ON TREE PROTECTION RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND

GAS
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-

E/L
w/W
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
FLOOR AREA RATIO (FAR) = (1884/7800)X100=24.1% 5. UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.
WATER RESOURCES CONTROL BOARD, FOR ANY ACTIVITY, WHICH DISTURBS
SOIL. SHEET TITLE:

GAS
28'-10"
6. ALL NEW ELECTRICAL SERVICE (POWER, PHONE, AND OR CABLE) SHALL BE

E/L
UNDER GROUND.

w/W
23'-3"
7. TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR
FOR FINAL INSPECTION. COVER SHEET

GAS
8. ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED
SCOPE OF WORK: AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPE AREAS.

w/W

E/L
NORTH
9. PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE
CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT
REMODELING AT THE HOUSE: FROM THE PUBLIC WORKS DEPARTMENT. 52' WATER
METER
PROJECT ID : D-1910-02
- TO ENLARGE THE KITCHEN AND FAMILY AREA. DATE : OCT.2019
- ADD THE FRONT PORCH 10. PROVIDE MIN. 5% GRADE SLOPE AWAY FROM FOUNDATION FOR A MIN. SCALE :
- ADD A BATHROOM DISTANCE OF 10 FEET MEASURE PERPENDICULAR TO THE FACE OF THE WALL. DRAWN BY : A.M.S
WITH EXCEPTION:
LEGEND: SHEET NUMBER:
a. IF BUILDING SITE DOES NOT ALLOW 10 FEET OF SLOPE, INDICATE THE
INSTALLATION OF DRAINS OR SWALES TO ENSURE DRAINAGE AWAY FROM THE
STRUCTURE.
b. IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION
SHALL BE SLOPED A MIN 2% AWAY FROM THE BUILDING.
HERVEY LANE
NEW ADDITION

PROPERTY LINE
A-00.01
OWNERSHIP:

11. (E) DRAINAGE SHALL REMAIN THROUGHOUT CONSTRUCTION. BLDG 1st FLOOR FOOTPRINT LINE THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE

PROPOSED SITE PLAN PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
1 SC : 1/8" = 1'-0"
GRAPHIC SCALE : 1/8 INCH = 1 FEET
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
0 2 4 6 8 10 20 30 WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
1868 2640 2640
AMS DESIGN

AMSDESIGN

MASTER BDRM
10'-11" X 13'-7"
2275 S. BASCOM AVE., SUITE 1406

5068
CAMPBELL, CA 95008
BEDROOM

6068
Tell: (415) 254.1606
13'-4" X 14'-6" e-MAIL: office@AMSDesignllp.com

2'-0" X 10'-3"
CLOSET
8068
Azadeh Masrour
2868

2468
MASTER BATH
9'-9" X 6'-0"

3620
6040
BEDROOM
13'-4" X 13'-3"

2468
CLOSET
9'-9" X 5'-0"

HERVEY's

SHED

SHED
6068

2668

RESIDENCE

7'-11" X 2'-0"
CLOSET
310210 2868 510210 4010 5030 10068 3020

NEW FURNACE IN THE ATTIC


IN THE ATTIC : 5' X 8' FURNACE PLATFORM
LESS THAN 20" FROM THE ATTIC ACCESS
2668
1490 HERVEY LN.
SAN JOSE, CA

3949
D/W

6040
ATTIC ACCESS
BEDROOM
BATH 9'-9" X 11'-0"
STORAGE

5'-0" X 5'-5"
8'-1" X 7'-8"

8' CEILING HEIGHT

OPENING
3'-6"
9' BOX CEILING
REVISION TABLE:
5'-0" X 10'-9"

KITCHEN & FAMILY


REVISION DATE BY
BATH

20'-8" X 26'-3"

BEDROOM
12'-2" 2468

9'-9" X 13'-1"

2868
2668

SKY L.
12'-2" X 15'-6"
KITCHEN

24" X 30"
BATH
5'-0" X 5'-0" 3'-2"

6'-3"

CRAWL SPACE
ACCESS TO
4168

2468
2668

CLOSET CLOSET
3'-6" 3'-0" 4'-8" X 2'-4"
4'-9" X 2'-4"
150'

2668
STORAGE
8'-1" X 7'-5"

2468
29210

4068

2868
ATTIC ACCESS

2468
2668

REF.
6068 CLOSET

3'-9"
2'-7" X 3'-3"

REF.
CRAWL SPACE

9'-9" X 2'-1"
ACCESS TO

CLOSET

2668 2668 3068

2668

6040
2668

WA.
ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
BEDROOM GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
LAUNDRY
8'-1" X 6'-4"

11'-1" X 10'-4" DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE

WA.
626035
196035
626035
3320

4020
LAUNDRY THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
5'-0" X 7'-0"

8'-1" X 6'-4" THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
BEDROOM
BATH

13'-4" X 9'-3"

WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE


12'-2" X 10'-5"

4930

1021935
RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
LIVING

SKY L. SKY L.
DR. PRECEDING AT HIS OWN RISK.

DR.
WH 24" X 30" 24" X 30"
OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-
2668 2668 DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
"N" PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
2068 TANKLESS WATER HEATER FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
2868
2568

SPECIFICATIONS.
BATH CLOSET
6'-0" X 6'-0" 4'-9" X 6'-0"
3'-10" X 2'-4"

SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY


3'-11" X 2'-0"
CLOSET

2468
ATTIC ACCESS

CLOSET

GAS METER

GAS METER
DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
9568 8068 THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
2468 OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-
42
68

CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN


68 3468 2468
28 RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED

2868
8' CEILING HEIGHT WORK.
9' BOX CEILING

SHEET TITLE:
4068
13'-3" X 13'-0"
FAMILY

ENTRY
BEDROOM
11'-1" X 11'-9"

8068
LIVING 4'-2" X 13'-5" BEDROOM
4'-2" X 11'-4"

11'-1" X 11'-9"
10'-1" X 20'-0"

13'-3" X 13'-0"
ENTRY
GARAGE

GARAGE
10'-1" X 20'-0"
PROPOSED
3432

3432

FLOOR
34210

ELEC. METER

ELEC. METER
PLAN
80310 3068 3340 8046 3068 6046 PROJECT ID : D-1910-02
DATE : OCT.2019
SCALE : 1/4" = 1'
DRAWN BY : A.M.S
8070 8070

SHEET NUMBER:

EXISTING FLOOR PLAN


NORTH A-01.02
PROPOSED FLOOR PLAN OWNERSHIP:
1 SC : 1/4" = 1'-0"
2 SC : 1/4" = 1'-0"
THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.
15'-4" TOP HT.
ABOVE F.F.

ELEVATION NOTES :
NEW ROOF MATERIAL WILL BE MATCH WITH EXISTING 40 YR.
AMS DESIGN

COMP. SHINGLE

9' PLATE HT.(ENTRY) ALL THE NEW EXTERIOR WALL MATERIAL WILL BE MATCHED
ABOVE F.F. WITH THE EXISTING (STUCCO WITH 7/8 INCH THIKNESS & TWO
8' PLATE HT.
ABOVE F.F. LAYERS GRADE D PAPER OVER THE PLYWOOD) AMSDESIGN
STUCCO LATH SHALL HAVE TWO LAYERS OF GRADE "D" PAPER
WHEN APPLIED OVER WOOD SHEATHING. PROVIDE WEEP 2275 S. BASCOM AVE., SUITE 1406
CAMPBELL, CA 95008
8046 6046
SCREED AT THE BOTTOM OF ALL FRAMED EXTERIOR WALLS AND Tell: (415) 254.1606
Electrical Meter
SOFFITS. WEEP SCREED SHALL HAVE A MINIMUM CLEARANCE e-MAIL: office@AMSDesignllp.com
8070
3068 OF 2" TO A PAVED SURFACE OR 4" TO EARTH.

Gas Meter
F.F.
ALL THE EXISTING WOOD SIDING EXTERIOR WALL MATERIAL
WILL BE REPLACED WITH THE NEW STUCCO WITH 7/8 INCH
THIKNESS & TWO LAYERS GRADE D PAPER OVER THE PLYWOOD.
Azadeh Masrour
PROPOSED FRONT ELEVATION
1 SC : 1/4" = 1'-0"

15'-4" TOP HT.


ABOVE F.F.

8' PLATE HT.


ABOVE F.F.

3020
HERVEY's
5030

Electrical Meter
2640 2640
RESIDENCE
10068

1490 HERVEY LN.


SAN JOSE, CA
Gas Meter
F.F.

REVISION TABLE:

REVISION DATE BY
PROPOSED REAR ELEVATION
2 SC : 1/4" = 1'-0"

15'-4" TOP HT.


ABOVE F.F.

8' PLATE HT.


ABOVE F.F. ALL WORK DESCRIBED IN THE DRAWINGS SHALL BE VERIFIED FOR DIMENSION,
GRADE, EXTENT AND COMPATIBILITY TO THE EXISTING SITE. ANY
DISCREPANCIES AND UNEXPECTED CONDITIONS THAT AFFECT OR CHANGE
THE WORK DESCRIBED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO
3620 THE AMS DESIGN’S ATTENTION IMMEDIATELY. DO NOT PROCEED WITH THE
WORK IN THE AREA OF DISCREPANCIES UNTIL ALL SUCH DISCREPANCIES ARE
6040 6040 RESOLVED. IF THE CONTRACTOR CHOOSES TO DO SO HE SHALL BE
PRECEDING AT HIS OWN RISK.
Electrical Meter

OMISSIONS FROM THE DRAWINGS AND SPECIFICATIONS OR THE MIS-


DESCRIPTION OF THE WORK WHICH IS MANIFESTLY NECESSARY TO CARRY
OUT THE INTENT OF THE DRAWINGS AND SPECIFICATIONS, OR WHICH IS
CUSTOMARILY REFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM
Gas Meter
PERFORMING SUCH OMITTED OR MIS-DESCRIBED DETAILS OF THE WORK AS IF
F.F. FULLY AND COMPLETELY SET FORTH AND DESCRIBED IN THE DRAWINGS AND
SPECIFICATIONS.

SITE CONDITIONS: ALL CONTRACTORS AND SUB-CONTRACTORS SHALL VERIFY


DIMENSIONS AND CONDITIONS AT THE SITE PRIOR TO COMMENCEMENT OF
THEIR WORK. FAILURE TO DO SO SHALL NOT RELEASE THEM FROM THE
RESPONSIBILITY OF ESTIMATING THE WORK. IF ANY VARIATION, DISCREPANCY
OR OMISSION (BETWEEN THE INTENT OF THESE CONTRACT DOCUMENTS AND
PROPOSED RIGHT ELEVATION THE EXISTING CONDITIONS ARE FOUND, THE CONTRACTOR OR SUB-

3 SC : 1/4" = 1'-0"
CONTRACTOR SHALL NOTIFY AMS DESIGN IN WRITING AND OBTAIN WRITTEN
RESOLUTION FROM AMS DESIGN PRIOR TO PROCEEDING WITH ANY RELATED
WORK.

SHEET TITLE:

15'-4" TOP HT.


ABOVE F.F.

PROPOSED
ELEVATIONS

8' PLATE HT.


ABOVE F.F.
PROJECT ID : D-1910-02
4020
DATE : OCT.2019
SCALE : 1/4" = 1'
6040 3432 DRAWN BY : A.M.S
6068
SHEET NUMBER:

F.F.
A-02.01
OWNERSHIP:

PROPOSED LEFT ELEVATION THESE PLANS ARE INTENDED ONLY FOR THE ORIGINAL SITE FOR WHICH THEY
WERE DESIGNED AND ARE THE PROPERTY OF AMS DESIGN. THESE PLANS ARE
4 SC : 1/4" = 1'-0"
PROTECTED UNDER COPYRIGHT LAWS AND MAY NOT BE REVISED OR
REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESSED WRITTEN
CONSENT OF AMS DESIGN. ANY USE OF THESE PLANS ON OTHER SITES IS
PROHIBITED WITHOUT THE CONSENT OF AMS DESIGN. ANY DISCREPANCY
DISCOVERED ON THESE PLANS SHALL PRIOR TO COMMENCEMENT OF THE
WORK IN QUESTION. ALL WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE
OVER SCALED DIMENSIONS.