Professional Documents
Culture Documents
Guide
Fastener Selection
Guide EJOT
6.2
Fastener Selection
Guide EJOT
Ridge / Eaves*
6.3
Fastener Selection
Guide EJOT
Application: Roof Type of Panel: RW, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened Steel, Grade 304 Hardened Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
25 JT2-D-6H-5.5 × 82 V16 JT3-D-6H-5.5 × 107 E16 JZ2 6.3 × 80 V16 1) 3) JZ3 6.3 × 80 E16 1) 3)
1) 3)
40 JT2-D-6H-5.5 × 102 V16 JT3-D-6H-5.5 × 107 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 100 E16 1) 3)
1) 3)
50 JT2-D-6H-5.5 × 122 V16 JT3-D-6H-5.5 × 127 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 100 E16 1) 3)
STEEL
Cold Rolled 60 JT2-D-6H-5.5 × 122 V16 JT3-D-6H-5.5 × 127 E16 JZ2 6.3 × 125 V16 1) 3) JZ3 6.3 × 115 E16 1) 3)
(thickness 70 JT2-D-6H-5.5 × 152 V16 JT3-D-6H-5.5 × 147 E16 JZ2 6.3 × 125 V16 1) 3) JZ3 6.3 × 125 E16 1) 3)
2.0–5.0 mm)
80 JT2-D-6H-5.5 × 152 V16 JT3-D-6H-5.5 × 147 E16 JZ2 6.3 × 150 V16 1) 3) JZ3 6.3 × 135 E16 1) 3)
1) 3)
100 JT2-D-6H-5.5 × 172 V16 JT3-D-6H-5.5 × 167 E16 JZ2 6.3 × 150 V16 JZ3 6.3 × 150 E16 1) 3)
1) 3)
120 JT2-D-6H-5.5 × 192 V16 JT3-D-6H-5.5 × 197 E16 JZ2 6.3 × 175 V16 JZ3 6.3 × 175 E16 1) 3)
2)
25 JT2-D-12H-5.5 × 95 V16 JT3-D-12H-5.5 × 115 E16 JZ2 6.3 × 80 V16 JZ3 6.3 × 80 E16 2)
2)
40 JT2-D-12H-5.5 × 115 V16 JT3-D-12H-5.5 × 115 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 100 E16 2)
2)
50 JT2-D-12H-5.5 × 135 V16 JT3-D-12H-5.5 × 135 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 100 E16 2)
STEEL
Hot Rolled 60 JT2-D-12H-5.5 × 135 V16 JT3-D-12H-5.5 × 135 E16 JZ2 6.3 × 125 V16 2) JZ3 6.3 × 115 E16 2)
(thickness 70 JT2-D-12H-5.5 × 155 V16 JT3-D-12H-5.5 × 155 E16 JZ2 6.3 × 125 V16 2) JZ3 6.3 × 125 E16 2)
3.0–12.0 mm)
80 JT2-D-12H-5.5 × 155 V16 JT3-D-12H-5.5 × 155 E16 JZ2 6.3 × 150 V16 2) JZ3 6.3 × 135 E16 2)
2)
100 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 175 E16 JZ2 6.3 × 150 V16 JZ3 6.3 × 150 E16 2)
2)
120 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 195 E16 JZ2 6.3 × 175 V16 JZ3 6.3 × 175 E16 2)
Screw Set Anchor Self-Tapping Fasteners
25 — — FBS-R-6.3 × 60 V16 —
40 — — FBS-R-6.3 × 80 V16 —
50 — — FBS-R-6.3 × 100 V16 —
CONCRETE 60 — — FBS-R-6.3 × 100 V16 —
70 — — FBS-R-6.3 × 120 V16 —
80 — — FBS-R-6.3 × 120 V16 —
100 — — FBS-R-6.3 × 140 V16 —
120 — — FBS-R-6.3 × 160 V16 —
Self-Drilling Fasteners Self-Tapping Fasteners
25 JT2-2-6.5 × 90 V16 JT3-2-6.5 × 120 E16 JA2 6.5 × 90 V16 JA3 6.5 × 90 E16
40 JT2-2-6.5 × 90 V16 JT3-2-6.5 × 140 E16 JA2 6.5 × 100 V16 JA3 6.5 × 100 E16
50 — JT3-2-6.5 × 160 E16 JA2 6.5 × 125 V16 JA3 6.5 × 100 E16
TIMBER 60 — JT3-2-6.5 × 160 E16 JA2 6.5 × 125 V16 JA3 6.5 × 115 E16
70 — JT3-2-6.5 × 180 E16 JA2 6.5 × 150 V16 JA3 6.5 × 125 E16
80 — JT3-2-6.5 × 180 E16 JA2 6.5 × 150 V16 JA3 6.5 × 150 E16
100 — JT3-2-6.5 × 200 E16 JA2 6.5 × 175 V16 JA3 6.5 × 175 E16
120 — — JA2 6.5 × 175 V16 JA3 6.5 × 175 E16
Note:
1) For the steel construction with the thickness under 2 mm are determined “JA” screws of the corresponding lengths and types
2) The screw will be completed with the calotte 32–25 (dia. of the washer has to be 16 mm)
3) The screws are usually pre-drilled with the dia. 5 mm; when they are used into concrete of the higher solidity or are applied deeper than min. 30 mm it is allowed
to predrill onto dia. 5.5 mm
– for panel RW / GRP40 and RW / HTL has to be use calotte 32–25 (dia. of the washer has to be 16 mm)
– The “JZ” screws are usually pre-drilled with dia. According to thickness of structure and information in the catalogue of the producer
– for higher strength steel are usually screws “JZ7” (CRONIMAKS), not “JZ3” and for highly aggressive environments (e.g. Swimming pool) “JZ1” (CORREMAKS).
– The “JA” screws are usually pre-drilled with dia. 4.5 mm and minimal length of the screw in the timber is 50 mm
6.4
Fastener Selection
Guide EJOT
6.5
Fastener Selection
Guide EJOT
STEEL X-DEK / Steel JT2-12-5.5 × 35 V16 JT3-12-5.5 × 40 E16 JZ2 6.3 × 25 V16 1) JZ3 6.3 × 25 E16 1)
Hot Rolled
(thickness
3.0–12.0 mm) X-DEK / TR JT2-12-5.5 × 35 V16 JT3-12-5.5 × 40 E16 JZ2 6.3 × 25 V16 1) JZ3 6.3 × 25 E16 1)
TIMBER X-DEK / Steel JT2-2-6.5 × 50 V16 JT3-2-6.5 × 50 E16 JA3 6.5 × 25E16 JA3 6.5 × 25E16
X-DEK / TR JT2-2-6.5 × 50 V16 JT3-2-6.5 × 50 E16 JA3 6.5 × 25E16 JA3 6.5 × 25E16
Note:
1) For the steel construction with the thickness under 2 mm are determined “JA” screws of the corresponding lengths and types
3) The screws are usually pre-drilled with the dia. 5 mm; when they are used into concrete of the higher solidity or are applied deeper than min. 30 mm it is allowed
to predrill onto dia. 5.5 mm
4) Assembling – plastic part of the anchor into pre-drilled hole dia. 10 mm
– the panel (outer and insulation) must be pre-drilled
– The “JZ” screws are usually pre-drilled with dia. According to thickness of structure and information in the catalogue of the producer
– for higher strength steel are usually screws “JZ7” (CRONIMAKS), not “JZ3” and for highly aggressive environments (e.g. Swimming pool) “JZ1” (CORREMAKS).
– The “JA” screws are usually pre-drilled with dia. 4.5 mm and minimal length of the screw in the timber is 50 mm
6.6
Fastener Selection
Guide EJOT
6.7
Fastener Selection
Guide EJOT
6.8
Fastener Selection
Guide EJOT
6.9
Fastener Selection
Guide EJOT
Application: Roof Type of Panel: FF, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened Steel, Grade 304 Hardened Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
60 JT2-D-6H-5.5 × 122 V16 JT3-D-6H-5.5 × 127 E16 JZ2-6.3 × 125 V16 1) 2) JZ3-6.3 × 115 E16 1) 2)
1) 2)
80 JT2-D-6H-5.5 × 152 V16 JT3-D-6H-5.5 × 147 E16 JZ2-6.3 × 150 V16 JZ3-6.3 × 135 E16 1) 2)
STEEL
1) 2)
Cold Rolled 100 JT2-D-6H-5.5 × 172 V16 JT3-D-6H-5.5 × 167 E16 JZ2-6.3 × 150 V16 JZ3-6.3 × 150 E16 1) 2)
(thickness 120 JT2-D-6H-5.5 × 192 V16 JT3-D-6H-5.5 × 197 E16 JZ2-6.3 × 175 V16 1) 2) JZ3-6.3 × 175 E16 1) 2)
2.0–5.0 mm)
150 — JT3-D-6H-5.5 × 237 E16 — JZ3-6.3 × 200 E16 1) 2)
200 — — — JZ3-6.3 × 270 E16 1) 2)
60 JT2-D-12H-5.5 × 135 V16 JT3-D-12H-5.5 × 135 E16 JZ2-6.3 × 125 V16 2) JZ3-6.3 × 115 E16 2)
2)
80 JT2-D-12H-5.5 × 155 V16 JT3-D-12H-5.5 × 155 E16 JZ2-6.3 × 150 V16 JZ3-6.3 × 135 E16 2)
STEEL
2)
Hot Rolled 100 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 175 E16 JZ2-6.3 × 150 V16 JZ3-6.3 × 150 E16 2)
(thickness 120 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 195 E16 JZ2-6.3 × 175 V16 2)
JZ3-6.3 × 175 E16 2)
3.0–12.0 mm)
150 JT2-D-12H-5.5 × 235 V16 JT3-D-12H-5.5 × 245 E16 — JZ3-6.3 × 200 E16 2)
200 JT2-D-12H-5.5 × 300 V16 — — JZ3-6.3 × 270 E16 2)
Screw Set Anchor Self-Tapping Fasteners
60 SDF-S 8 × 160 -V + V22 5) SDF-S 8 × 160 -E + E22 5) BS-R-6.3 × 140 V22 2) 3) —
5) 5) 2) 3)
80 SDF-S 8 × 180 -V + V22 SDF-S 8 × 180 -E + E22 BS-R-6.3 × 160 V22 —
CONCRETE 100 SDF-S 8 × 200 -V + V22 5) SDF-S 8 × 200 -E + E22 5) BS-R-6.3 × 180 V22 2) 3) —
120 SDF-S 8 × 220 -V + V22 5) SDF-S 8 × 220 -E + E22 5) BS-R-6.3 × 200 V22 2) 3) —
150 — — BS-R-6.3 × 220 V22 2) 3) —
200 — — — —
Self-Drilling Fasteners Self-Tapping Fasteners
60 — JT3-2-6.5 × 160 E16 JA2 6.5 × 150 V16 2) JA3 6.5 × 150 E16 2)
2)
80 — JT3-2-6.5 × 180 E16 JA2 6.5 × 175 V16 JA3 6.5 × 175 E16 2)
2)
TIMBER 100 — JT3-2-6.5 × 200 E16 JA2 6.5 × 200 V16 JA3 6.5 × 200 E16 2)
120 — — — JA3 6.5 × 230 E16 2)
150 — — — JA3 6.5 × 260 E16 2)
200 — — — JA3 6.5 × 290 E16 2)
Note:
1) For the steel construction with the thickness under 2 mm are determined “JA” screws of the corresponding lengths and types
2) The screw will be completed with the calotte 26–27 (dia. of the washer has to be 16 mm)
3) The screws are usually pre-drilled with the dia. 5 mm; when they are used into concrete of the higher solidity or are applied deeper than min. 30 mm it is allowed
to predrill onto dia. 5.5 mm
5) Assembling – plastic part of the anchor into pre-drilled hole dia. 8 mm; screw with both washers (the washer and calotte the storm washer) into plastic part of
the anchor
– for panel FF / GRP40 and FF / HTL has to be use calotte 26–27 (dia. of the washer has to be 16 mm)
– The “JZ” screws are usually pre-drilled with dia. According to thickness of structure and information in the catalogue of the producer
– for higher strength steel are usually screws “JZ7” (CRONIMAKS), not “JZ3” and for highly aggressive environments (e.g. Swimming pool) “JZ1” (CORREMAKS).
– The “JA” screws are usually pre-drilled with dia. 4.5 mm and minimal length of the screw in the timber is 50 mm
6.10
Fastener Selection
Guide EJOT
6.11
Fastener Selection
Guide EJOT
Application: Wall, Ceiling Type of Panel: TF, TC, TL, RW, FR, FA Fixing position: VALLEY
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened Steel, Grade 304 Hardened Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
25 JT2-D-6H-5.5 × 62 V16 JT3-D-6H-5.5 × 67 E16 JZ2 6.3 × 50 V16 1) JZ3 6.3 × 50 E16 1)
1)
40 JT2-D-6H-5.5 × 82 V16 JT3-D-6H-5.5 × 87 E16 JZ2 6.3 × 64 V16 JZ3 6.3 × 64 E16 1)
1)
50 JT2-D-6H-5.5 × 82 V16 JT3-D-6H-5.5 × 87 E16 JZ2 6.3 × 80 V16 JZ3 6.3 × 80 E16 1)
1)
60 JT2-D-6H-5.5 × 102 V16 JT3-D-6H-5.5 × 107 E16 JZ2 6.3 × 90 V16 JZ3 6.3 × 90 E16 1)
STEEL 70 JT2-D-6H-5.5 × 102 V16 JT3-D-6H-5.5 × 107 E16 JZ2 6.3 × 100 V16 1)
JZ3 6.3 × 100 E16 1)
Cold Rolled 80 JT2-D-6H-5.5 × 122 V16 JT3-D-6H-5.5 × 127 E16 JZ2 6.3 × 100 V16 1)
JZ3 6.3 × 115 E16 1)
(thickness
1)
2.0–5.0 mm) 100 JT2-D-6H-5.5 × 152 V16 JT3-D-6H-5.5 × 147 E16 JZ2 6.3 × 125 V16 JZ3 6.3 × 125 E16 1)
1)
120 JT2-D-6H-5.5 × 152 V16 JT3-D-6H-5.5 × 167 E16 JZ2 6.3 × 150 V16 JZ3 6.3 × 150 E16 1)
1)
150 JT2-D-6H-5.5 × 172 V16 JT3-D-6H-5.5 × 197 E16 JZ2 6.3 × 175 V16 JZ3 6.3 × 175 E16 1)
1)
170 JT2-D-6H-5.5 × 192 V16 JT3-D-6H-5.5 × 237 E16 JZ2 6.3 × 200 V16 JZ3 6.3 × 200 E16 1)
200 — JT3-D-6H-5.5 × 237 E16 — JZ3 6.3 × 230 E16 1)
25 JT2-D-12-5.5 × 65 V16 JT3-D-12H-5.5 × 75 E16 JZ2 6.3 × 50 V16 JZ3 6.3 × 50 E16
40 JT2-D-12H-5.5 × 80 V16 JT3-D-12H-5.5 × 95 E16 JZ2 6.3 × 64 V16 JZ3 6.3 × 64 E16
50 JT2-D-12H-5.5 × 95 V16 JT3-D-12H-5.5 × 95 E16 JZ2 6.3 × 80 V16 JZ3 6.3 × 80 E16
60 JT2-D-12H-5.5 × 115 V16 JT3-D-12H-5.5 ×115 E16 JZ2 6.3 × 90 V16 JZ3 6.3 × 90 E16
STEEL 70 JT2-D-12H-5.5 × 115 V16 JT3-D-12H-5.5 × 115 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 100 E16
Hot Rolled 80 JT2-D-12H-5.5 × 135 V16 JT3-D-12H-5.5 × 135 E16 JZ2 6.3 × 100 V16 JZ3 6.3 × 115 E16
(thickness
3.0–12.0 mm) 100 JT2-D-12H-5.5 × 155 V16 JT3-D-12H-5.5 × 155 E16 JZ2 6.3 × 125 V16 JZ3 6.3 × 125 E16
120 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 175 E16 JZ2 6.3 × 150 V16 JZ3 6.3 × 150 E16
150 JT2-D-12H-5.5 × 195 V16 JT3-D-12H-5.5 × 195 E16 JZ2 6.3 × 175 V16 JZ3 6.3 × 175 E16
170 JT2-D-12H-5.5 × 235 V16 JT3-D-12H-5.5 × 245 E16 JZ2 6.3 × 200 V16 JZ3 6.3 × 200 E16
200 JT2-D-12H-5.5 × 235 V16 JT3-D-12H-5.5 × 245 E16 — JZ3 6.3 × 230 E16
Screw Set Anchor Self-Tapping Fasteners
25 SDF-KB 10 × 80 -V 4) 8) SDF-KB 10 × 80 -E 4) 8) FBS-R-6.3 × 60 V16 3) —
40 SDF-KB 10 × 100 -V 4) 8) SDF-KB 10 × 100 -E 4) 8) FBS-R-6.3 × 80 V16 3) —
50 SDF-KB 10 × 120 -V 4) 8) SDF-KB 10 × 120 -E 4) 8) FBS-R-6.3 × 100 V16 3) —
60 SDF-KB 10 × 120 -V 4) 8) SDF-KB 10 × 120 -E 4) 8) FBS-R-6.3 × 100 V16 3) —
70 SDF-KB 10 × 140 -V 4) 8) SDF-KB 10 × 140 -E 4) 8) BS-R-6.3 × 120 V16 3) —
CONCRETE
80 SDF-KB 10 × 140 -V 4) 8) SDF-KB 10 × 140 -E 4) 8) BS-R-6.3 × 120 V16 3) —
100 SDF-KB 10 × 160 -V 4) 8) SDF-KB 10 × 160 -E 4) 8) BS-R-6.3 × 140 V16 3) —
120 SDF-KB 10 × 180 -V 4) 8) SDF-KB 10 × 180 -E 4) 8) BS-R-6.3 × 160 V16 3) —
150 SDF-KB 10 × 220 -V 4) 8) SDF-KB 10 × 220 -E 4) 8) BS-R-6.3 × 200 V16 3) —
170 SDF-KB 14U × 260 -V 4) 8) SDF-KB 14U × 260 -E 4) 8) BS-R-6.3 × 220 V16 3) —
200 SDF-KB 14U × 280 -V 4) 8) SDF-KB 14U × 280 -E 4) 8) BS-R-6.3 × 240 V16 3) —
Self-Drilling Fasteners Self-Tapping Fasteners
25 JT2-2-6.5 × 90 V16 JT3-2-6.5 × 80 E16 JA2 6.5 × 90 V16 JA3 6.5 × 90 E16
40 JT2-2-6.5 × 90 V16 JT3-2-6.5 × 100 E16 JA2 6.5 × 100 V16 JA3 6.5 × 100 E16
50 — JT3-2-6.5 × 100 E16 JA2 6.5 × 125 V16 JA3 6.5 × 100 E16
60 — JT3-2-6.5 × 120 E16 JA2 6.5 × 125 V16 JA3 6.5 × 115 E16
70 — JT3-2-6.5 × 120 E16 JA2 6.5 × 150 V16 JA3 6.5 × 125 E16
TIMBER
80 — JT3-2-6.5 × 140 E16 JA2 6.5 × 150 V16 JA3 6.5 × 150 E16
100 — JT3-2-6.5 × 160 E16 JA2 6.5 × 175 V16 JA3 6.5 × 175 E16
120 — JT3-2-6.5 × 180 E16 JA2 6.5 × 175 V16 JA3 6.5 × 175 E16
150 — — — JA3 6.5 × 230 E16
170 — — — JA3 6.5 × 230 E16
200 — — — JA3 6.5 × 260 E16
6.12
Fastener Selection
Guide EJOT
Note:
1) For the steel construction with the thickness under 2 mm are determined “JA” screws of the corresponding lengths and types
3) The screws are usually pre-drilled with the dia. 5 mm; when they are used into concrete of the higher solidity or are applied deeper than min. 30 mm it is allowed
to predrill onto dia. 5.5 mm
4) Assembling – plastic part of the anchor into pre-drilled hole dia. 10 mm
8) the screw set anchor can not be used for panel FR and FA
– for FR and FA panel has to be use the screw with sealing washer dia. 22 mm
– clamping thickness of panel RW for the screw = D + 5 mm
– The “JZ” screws are usually pre-drilled with dia. According to thickness of structure and information in the catalogue of the producer
– for higher strength steel are usually screws “JZ7” (CRONIMAKS), not “JZ3” and for highly aggressive environments (e.g. Swimming pool) “JZ1” (CORREMAKS).
– The “JA” screws are usually pre-drilled with dia. 4.5 mm and minimal length of the screw in the timber is 50 mm
KS1150 TL
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1150 FR
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1000 RW
Standard* Ridge / Eaves*
KS1150 FA
Standard* High Wind Load* (depending on wind loading / building location & size)
6.13
Fastener Selection
Guide EJOT
6.14
Fastener Selection
Guide EJOT
6.15
Fastener Selection
Guide Reisser
6.16
Fastener Selection
Guide Reisser
Ridge / Eaves*
6.17
Fastener Selection
Guide Reisser
Application: Roof Type of Panel: RW, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners 2)
25 — RP-K-P-5.5 × 92 E19 — FABA-BZ-6.3 × 75 E16
40 — RP-K-P-5.5 × 119 E19 — FABA-BZ-6.3 × 90 E16
50 — RP-K-P-5.5 × 119 E19 — FABA-BZ-6.3 × 100 E16
STEEL 60 — RP-K-P-5.5 × 135 E19 — FABA-BZ-6.3 × 115 E16
(thickness
1.5–4.0 mm) 70 — RP-K-P-5.5 × 135 E19 — FABA-BZ-6.3 × 115 E16
80 — RP-K-P-5.5 × 155 E19 — FABA-BZ-6.3 × 130 E16
100 — RP-K-P-5.5 × 178 E19 — FABA-BZ-6.3 × 150 E16
120 — RP-K-P-5.5 × 228 E19 — FABA-BZ-6.3 × 175 E16
25 — RP-K12-P-5.5 × 99 E19 — FABA-BZ-6.3 × 90 E16
40 — RP-K12-P-5.5 × 126 E19 — FABA-BZ-6.3 × 100 E16
50 — RP-K12-P-5.5 × 126 E19 — FABA-BZ-6.3 × 115 E16
STEEL 60 — RP-K12-P-5.5 × 142 E19 — FABA-BZ-6.3 × 115 E16
(thickness
4.0–10.0 mm) 70 — RP-K12-P-5.5 × 162 E19 — FABA-BZ-6.3 × 130 E16
80 — RP-K12-P-5.5 × 162 E19 — FABA-BZ-6.3 × 150 E16
100 — RP-K12-P-5.5 × 185 E19 — FABA-BZ-6.3 × 175 E16
120 — RP-K12-P-5.5 × 235 E19 — FABA-BZ-6.3 × 175 E16
25 — — — —
40 — — — —
50 — — — —
60 — — — —
CONCRETE 1)
70 — — — —
80 — — — —
100 — — — —
120 — — — —
25 — RP-r-P-6.0 × 119 E19 — FABA-A-6.5 × 90 E16
40 — RP-r-P-6.0 × 119 E19 — FABA-A-6.5 × 115 E16
50 — RP-r-P-6.0 × 135 E19 — FABA-A-6.5 × 115 E16
60 — RP-r-P-6.0 × 155 E19 — FABA-A-6.5 × 130 E16
TIMBER
70 — RP-r-P-6.0 × 155 E19 — FABA-A-6.5 × 150 E16
80 — RP-r-P-6.0 × 178 E19 — FABA-A-6.5 × 150 E16
100 — RP-r-P-6.0 × 178 E19 — FABA-A-6.5 × 175 E16
120 — RP-r-P-6.0 × 228 E19 — FABA-A-6.5 × 200 E16
25 — RP-TD-P-6.0 × 126 E19 — —
40 — RP-TD-P-6.0 × 126 E19 — —
50 — RP-TD-P-6.0 × 142 E19 — —
TIMBER 60 — RP-TD-P-6.0 × 142 E19 — —
spanlos 70 — RP-TD-P-6.0 × 162 E19 — —
80 — RP-TD-P-6.0 × 162 E19 — —
100 — RP-TD-P-6.0 × 185 E19 — —
120 — RP-TD-P-6.0 × 235 E19 — —
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– Additionally, the use of the storm washer W 24/30 is recommended
– clamping thickness of panels RW, GRP40, HTL for the screw = crown D + 35 mm
6.18
Fastener Selection
Guide Reisser
6.19
Fastener Selection
Guide Reisser
X-DEK / Steel — — — —
1)
CONCRETE
X-DEK / TR — — — —
TIMBER
Note:
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– The panel (steel cover sheets and insulation core) is pre-drilled
6.20
Fastener Selection
Guide Reisser
STEEL 80 — — — —
(thickness
1.5–4.0 mm) 100 — — — —
STEEL 80 — — — —
(thickness
4.0–10.0 mm) 100 — — — —
80 — — — —
CONCRETE 1)
100 — — — —
80 — — — —
TIMBER
100 — — — —
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– In the outside-sided fastener assembly includes a spreader plate is for all connectors to arrange 82/40
6.21
Fastener Selection
Guide Reisser
6.22
Fastener Selection
Guide Reisser
6.23
Fastener Selection
Guide Reisser
Application: Roof Type of Panel: FF, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners 2)
60 — RP-K-P-5.5 × 135 E19 — FABA-BZ-6.3 × 115 E16
80 — RP-K-P-5.5 × 155 E19 — FABA-BZ-6.3 × 130 E16
STEEL 100 — RP-K-P-5.5 × 178 E19 — FABA-BZ-6.3 × 150 E16
(thickness
1.5–4.0 mm) 120 — RP-K-P-5.5 × 228 E19 — FABA-BZ-6.3 × 175 E16
150 — RP-K-P-5.5 × 228 E19 — FABA-BZ-6.3 × 200 E16
200 — - — -
60 — RP-K12-P-5.5 × 142 E19 — FABA-BZ-6.3 × 115 E16
80 — RP-K12-P-5.5 × 162 E19 — FABA-BZ-6.3 × 150 E16
STEEL 100 — RP-K12-P-5.5 × 185 E19 — FABA-BZ-6.3 × 175 E16
(thickness
4.0–10.0 mm) 120 — RP-K12-P-5.5 × 235 E19 — FABA-BZ-6.3 × 175 E16
150 — RP-K12-P-5.5 × 235 E19 — FABA-BZ-6.3 × 200 E16
200 — — — —
60 — — — —
80 — — — —
100 — — — —
CONCRETE 1)
120 — — — —
150 — — — —
200 — — — —
60 — RP-r-P-6.0 × 135 E19 — FABA-A-6.5 × 130 E16
80 — RP-r-P-6.0 × 155 E19 — FABA-A-6.5 × 150 E16
100 — RP-r-P-6.0 × 178 E19 — FABA-A-6.5 × 175 E16
TIMBER
120 — RP-r-P-6.0 × 228 E19 — FABA-A-6.5 × 200 E16
150 — RP-r-P-6.0 × 228 E19 — —
200 — — — —
60 — RP-TD-P-6.0 × 142 E19 — —
80 — RP-TD-P-6.0 × 162 E19 — —
TIMBER 100 — RP-TD-P-6.0 × 185 E19 — —
spanlos 120 — RP-TD-P-6.0 × 235 E19 — —
150 — RP-TD-P-6.0 × 235 E19 — —
200 — — — —
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– Additionally, the use of the storm washer W 27/25 is recommended
– clamping thickness of panels FF, GRP40, HTL for the screw = crown D + 34 mm
6.24
Fastener Selection
Guide Reisser
6.25
Fastener Selection
Guide Reisser
Application: Wall, Ceiling Type of Panel: TF, TC, TL, RW, FR, FA Fixing position: VALLEY
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners 2)
25 — — — FABA-BZ-6.3 × 45 E16
40 — RP-K-P-5.5 × 78 E19 — FABA-BZ-6.3 × 64 E16
50 — RP-K-P-5.5 × 92 E19 — FABA-BZ-6.3 × 75 E16
60 — RP-K-P-5.5 × 92 E19 — FABA-BZ-6.3 × 90 E16
STEEL 70 — RP-K-P-5.5 × 119 E19 — FABA-BZ-6.3 × 90 E16
(thickness 80 — RP-K-P-5.5 × 119 E19 — FABA-BZ-6.3 × 100 E16
1.5–4.0 mm) 100 — RP-K-P-5.5 × 135 E19 — FABA-BZ-6.3 × 130 E16
120 — RP-K-P-5.5 × 155 E19 — FABA-BZ-6.3 × 150 E16
150 — RP-K-P-5.5 × 228 E19 — FABA-BZ-6.3 × 175 E16
170 — RP-K-P-5.5 × 228 E19 — FABA-BZ-6.3 × 200 E16
200 — — — —
25 — — — FABA-BZ-6.3 × 50 E16
40 — RP-K12-P-5.5 × 85 E19 — FABA-BZ-6.3 × 75 E16
50 — RP-K12-P-5.5 × 99 E19 — FABA-BZ-6.3 × 75 E16
60 — RP-K12-P-5.5 × 126 E19 — FABA-BZ-6.3 × 90 E16
STEEL 70 — RP-K12-P-5.5 × 126 E19 — FABA-BZ-6.3 × 100 E16
(thickness 80 — RP-K12-P-5.5 × 126 E19 — FABA-BZ-6.3 × 115 E16
4.0–10.0 mm) 100 — RP-K12-P-5.5 × 162 E19 — FABA-BZ-6.3 × 130 E16
120 — RP-K12-P-5.5 × 185 E19 — FABA-BZ-6.3 × 150 E16
150 — RP-K12-P-5.5 × 235 E19 — FABA-BZ-6.3 × 175 E16
170 — RP-K12-P-5.5 × 235 E19 — FABA-BZ-6.3 × 200 E16
200 — — — —
25 — — — —
40 — — — —
50 — — — —
60 — — — —
70 — — — —
CONCRETE 1) 80 — — — —
100 — — — —
120 — — — —
150 — — — —
170 — — — —
200 — — — —
25 — RP-r-6.0 × 75 E16 — FABA-A-6.5 × 64 E16
40 — RP-r-P-6.0 × 92 E19 — FABA-A-6.5 × 75 E16
50 — RP-r-P-6.0 × 119 E19 — FABA-A-6.5 × 90 E16
60 — RP-r-P-6.0 × 119 E19 — FABA-A-6.5 × 100 E16
70 — RP-r-P-6.0 × 119 E19 — FABA-A-6.5 × 115 E16
TIMBER 80 — RP-r-P-6.0 × 135 E19 — FABA-A-6.5 × 115 E16
100 — RP-r-P-6.0 × 155 E19 — FABA-A-6.5 × 150 E16
120 — RP-r-P-6.0 × 178 E19 — FABA-A-6.5 × 175 E16
150 — RP-r-P-6.0 × 228 E19 — FABA-A-6.5 × 200 E16
170 — RP-r-P-6.0 × 228 E19 — —
200 — — — —
25 — — — —
40 — RP-TD-P-6.0 × 99 E19 — —
50 — RP-TD-P-6.0 × 126 E19 — —
60 — RP-TD-P-6.0 × 126 E19 — —
70 — RP-TD-P-6.0 × 126 E19 — —
TIMBER
80 — RP-TD-P-6.0 × 142 E19 — —
spanlos
100 — RP-TD-P-6.0 × 162 E19 — —
120 — RP-TD-P-6.0 × 185 E19 — —
150 — RP-TD-P-6.0 × 235 E19 — —
170 — RP-TD-P-6.0 × 235 E19 — —
200 — — — —
6.26
Fastener Selection
Guide Reisser
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– for FR and FA panel has to be use the screw with sealing washer d. 22 mm
KS1150 TL
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1150 FR
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1000 RW
Standard* Ridge / Eaves*
KS1150 FA
Standard* High Wind Load* (depending on wind loading / building location & size)
6.27
Fastener Selection
Guide Reisser
6.28
Fastener Selection
Guide Reisser
6.29
Fastener Selection
Guide SFS intec
6.30
Fastener Selection
Guide SFS intec
Ridge / Eaves*
6.31
Fastener Selection
Guide SFS intec
Application: Roof Type of Panel: RW, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
25 SDT5-A16-5.5 × 97† SXC5-S16-5.5 × 95 — TDA-S-S16-6.5 × 76 2)
40 SDT5-A16-5.5 × 97 SXC5-S16-5.5 × 115 — TDA-S-S16-6.5 × 100 2)
STEEL 50 SDT5-A16-5.5 × 112 SXC5-S16-5.5 × 115 — TDA-S-S16-6.5 × 100 2)
Cold Rolled 60 SDT5-A16-5.5 × 137 SXC5-S16-5.5 × 135 — TDA-S-S16-6.5 × 115 2)
(thickness
1.5–4.0 mm 70 SDT5-A16-5.5 × 137 SXC5-S16-5.5 × 135 — TDA-S-S16-6.5 × 127 2)
†
1.5–5.0 mm) 80 SDT5-A16-5.5 × 162 SXC5-S16-5.5 × 160 — TDA-S-S16-6.5 × 152 2)
100 SDT5-A16-5.5 × 162 SXC5-S16-5.5 × 185 — TDA-S-S16-6.5 × 152 2)
120 SDT5-A16-5.5 × 182 SXC5-S16-5.5 × 185 — TDA-S-S16-6.5 × 178 2)
25 SDT14-A16-5.5 × 93 SXC14-A16-5.5 × 100 — TDB-S-S16-6.3 × 76 2)
40 SDT14-A16-5.5 × 113 SXC14-A16-5.5 × 120 — TDB-S-S16-6.3 × 100 2)
50 SDT14-A16-5.5 × 113 SXC14-A16-5.5 × 120 — TDB-S-S16-6.3 × 100 2)
STEEL
Hot Rolled 60 SDT14-A16-5.5 × 142 SXC14-A16-5.5 × 140 — TDB-S-S16-6.3 × 115 2)
(thickness 70 SDT14-A16-5.5 × 142 SXC14-A16-5.5 × 140 — TDB-S-S16-6.3 × 127 2)
4.0–13.0 mm)
80 SDT14-A16-5.5 × 142 SXC14-A16-5.5 × 165 — TDB-S-S16-6.3 × 152 2)
100 SDT14-A16-5.5 × 189 SXC14-A16-5.5 × 190 — TDB-S-S16-6.3 × 152 2)
120 SDT14-A16-5.5 × 189 SXC14-A16-5.5 × 190 — TDB-S-S16-6.3 × 178 2)
2)
25 — — TI-T16-6.3 × 95 DT-S-S16-4.8 × 115 3)
2)
40 — — TI-T16-6.3 × 105 DT-S-S16-4.8 × 115 3)
2)
50 — — TI-T16-6.3 × 115 DT-S-S16-4.8 × 140 3)
60 — — TI-T16-6.3 × 135 2) DT-S-S16-4.8 × 140 3)
CONCRETE 1)
70 — — TI-T16-6.3 × 145 2) DT-S-S16-4.8 × 140 3)
2)
80 — — TI-T16-6.3 × 155 DT-S-S16-6.3 × 152 3)
2)
100 — — TI-T16-6.3 × 175 DT-S-S16-6.3 × 178 3)
2)
120 — — TI-T16-6.3 × 195 DT-S-S16-6.3 × 203 3)
25 — SXCW-S16-6.5 × 115 — TDA-S-S16-6.5 × 115 2)
40 SDTW-A16-6.5 × 115 SXCW-S16-6.5 × 135 — TDA-S-S16-6.5 × 127 2)
50 SDTW-A16-6.5 × 125 SXCW-S16-6.5 × 135 — TDA-S-S16-6.5 × 127 2)
60 SDTW-A16-6.5 × 135 SXCW-S16-6.5 × 155 — TDA-S-S16-6.5 × 152 2)
TIMBER
70 — SXCW-S16-6.5 × 155 — TDA-S-S16-6.5 × 152 2)
80 — SXCW-S16-6.5 × 185 — TDA-S-S16-6.5 × 178 2)
100 — SXCW-S16-6.5 × 185 — TDA-S-S16-6.5 × 178 2)
120 — SXCW-S16-6.5 × 205 — TDA-S-S16-6.5 × 215 2)
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) If you are using self-tapping fastener caps to be used 32–25
3) When using the fasteners of the type “spike twister” are domes to use 32–25
– clamping thickness of panels RW, GRP40, HTL for the screw = crown D + 35 mm
– for panel GRP40 and HTL has to be use calotte 32–25
6.32
Fastener Selection
Guide SFS intec
6.33
Fastener Selection
Guide SFS intec
SD5-T15-5.5 × 25
STEEL X-DEK / Steel SX5/8-S16-5.5 × 31 — TDA-S-S16-6.5 × 25
min UK: 2.0 mm
Cold Rolled
(thickness
1.5–3.0 mm)
X-DEK / TR SD3-D10-T19/C9-5.5x30 SX5/8-S16-5.5 × 31 — TDA-S-S16-6.5 × 25
TIMBER
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
6.34
Fastener Selection
Guide SFS intec
80 — — TS-T25-6.0 × 220 2) —
TIMBER
100 — — TS-T25-6.0 × 240 2) —
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
– clamping thickness of panels X-DEK for the screw = crown D + 108 mm
6.35
Fastener Selection
Guide SFS intec
6.36
Fastener Selection
Guide SFS intec
6.37
Fastener Selection
Guide SFS intec
Application: Roof Type of Panel: FF, GRP40, HTL Fixing position: CROWN
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
60 SDT5-A22-5.5 × 137† SXC5-S22-5.5 × 135 — TDA-S-S16-6.5 × 115 2)
STEEL 80 SDT5-A22-5.5 × 162 SXC5-S22-5.5 × 160 — TDA-S-S16-6.5 × 127 2)
Cold Rolled 100 SDT5-A22-5.5 × 162 SXC5-S22-5.5 × 185 — TDA-S-S16-6.5 × 152 2)
(thickness
1.5–3.0 mm 120 SDT5-A22-5.5 × 182 SXC5-S22-5.5 × 185 — TDA-S-S16-6.5 × 178 2)
†
1.5–4.0 mm) 150 SDT5-A22-5.5 × 226 SXC5-S22-5.5 × 235 — TDA-S-S16-6.5 × 215 2)
200 SDT5-A22-5.5 × 276 SXC5-S22-5.5 × 270 — TDA-S-S16-6.5 × 250 2)
60 SDT14-A22-5.5 × 142 SXC14-S22-5.5 × 140 — TDB-S-S16-6.3 × 115 2)
80 SDT14-A22-5.5 × 142 SXC14-S22-5.5 × 165 — TDB-S-S16-6.3 × 127 2)
STEEL
Hot Rolled 100 SDT14-A22-5.5 × 160 SXC14-S22-5.5 × 190 — TDB-S-S16-6.3 × 152 2)
(thickness 120 SDT14-A22-5.5 × 189 SXC14-S22-5.5 × 190 — TDB-S-S16-6.3 × 178 2)
3.0–14.0 mm)
150 SDT14-A22-5.5 × 215 SXC14-S22-5.5 × 240 — TDB-S-S16-6.3 × 215 2)
200 SDT14-A22-5.5 × 276 SXC14-S22-5.5 × 275 — TDB-S-S16-6.3 × 250 2)
60 — — TI-T16-6.3 × 135 2) DT-S-S16-4.8 × 140 2)
80 — — TI-T16-6.3 × 145 2) DT-S-S16-6.3 × 152 2)
2)
100 — — TI-T16-6.3 × 165 DT-S-S16-6.3 × 178 2)
CONCRETE 1) 2)
120 — — TI-T16-6.3 × 195 DT-S-S16-6.3 × 203 2)
2)
150 — — TI-T16-6.3 × 215 DT-S-S16-6.3 × 229 2)
2)
200 — — TI-T16-6.3 × 275 DT-S-S16-6.3 × 279 2)
2)
60 SDTW-A22-6.5 × 135 SXCW-S22-6.5 × 155 TDA-T-T16-6.5 × 152 TDA-S-S16-6.5 × 152 2)
80 — SXCW-S22-6.5 × 185 TDA-T-T16-6.5 × 152 2) TDA-S-S16-6.5 × 178 2)
100 — SXCW-S22-6.5 × 185 TDA-T-T16-6.5 × 178 2) TDA-S-S16-6.5 × 178 2)
TIMBER 2)
120 — SXCW-S22-6.5 × 205 TDA-T-T16-6.5 × 215 TDA-S-S16-6.5 × 215 2)
2)
150 — SXCW-S22-6.5 × 235 TDA-T-T16-6.5 × 250 TDA-S-S16-6.5 × 250 2)
200 — SXCW-S22-6.5 × 305 — TDA-S-S16-6.5 × 300 2)
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
2) The respective pilot hole can be found in the manufacturer’s hole tables.
– for panels FF / GRP40 and FF / HTL has to be use calotte 26–27 (dia. of the washer has to be 16 mm)
6.38
Fastener Selection
Guide SFS intec
6.39
Fastener Selection
Guide SFS intec
Application: Wall, Ceiling Type of Panel: TF, TC, TL, RW, FR, FA Fixing position: VALLEY
Insulation Code Numbers
Core Carbon Steel Case Austenitic stainless Carbon Steel Case Austenitic stainless
Support
Thickness Hardened *) Steel, Grade 304 Hardened *) Steel, Grade 304
[mm] Self-Drilling Fasteners Self-Tapping Fasteners
25 SD5-A16-5.5 × 57† SX25-S16-5.5 × 75 — TDA-S-S16-6.5 × 45
40 SDT5-A16-5.5 × 67 SXC5-S16-5.5 × 75 — TDA-S-S16-6.5 × 64
50 SDT5-A16-5.5 × 77 SXC5-S16-5.5 × 95 — TDA-S-S16-6.5 × 76
60 SDT5-A16-5.5 × 97 SXC5-S16-5.5 × 95 — TDA-S-S16-6.5 × 76
STEEL
70 SDT5-A16-5.5 × 97 SXC5-S16-5.5 × 115 — TDA-S-S16-6.5 × 90
Cold Rolled
(thickness 80 SDT5-A16-5.5 × 112 SXC5-S16-5.5 × 115 — TDA-S-S16-6.5 × 100
1.5–3.0 mm
†
100 SDT5-A16-5.5 × 137 SXC5-S16-5.5 × 135 — TDA-S-S16-6.5 × 127
1.5–4.0 mm)
120 SDT5-A16-5.5 × 162 SXC5-S16-5.5 × 160 — TDA-S-S16-6.5 × 152
150 SDT5-A16-5.5 × 182 SXC5-S16-5.5 × 195 — TDA-S-S16-6.5 × 178
170 SDT5-A16-5.5 × 226 SXC5-S16-5.5 × 210 — TDA-S-S16-6.5 × 215
200 SDT5-A16-5.5 × 226 SXC5-S16-5.5 × 235 — TDA-S-S16-6.5 × 215
25 SD14-A16-5.5 × 56 SXC14-S16-5.5 × 80 — TDB-S-S16-6.3 × 45
40 SDT14-A16-5.5 × 74 SXC14-S16-5.5 × 80 — TDB-S-S16-6.3 × 64
50 SDT14-A16-5.5 × 93 SXC14-S16-5.5 × 100 — TDB-S-S16-6.3 × 76
60 SDT14-A16-5.5 × 93 SXC14-S16-5.5 × 100 — TDB-S-S16-6.3 × 76
STEEL 70 SDT14-A16-5.5 × 113 SXC14-S16-5.5 × 120 — TDB-S-S16-6.3 × 90
Hot Rolled 80 SDT14-A16-5.5 × 113 SXC14-S16-5.5 × 120 — TDB-S-S16-6.3 × 100
(thickness
3.0–14.0 mm) 100 SDT14-A16-5.5 × 142 SXC14-S16-5.5 × 140 — TDB-S-S16-6.3 × 127
120 SDT14-A16-5.5 × 160 SXC14-S16-5.5 × 165 — TDB-S-S16-6.3 × 152
150 SDT14-A16-5.5 × 189 SXC14-S16-5.5 × 190 — TDB-S-S16-6.3 × 178
170 SDT14-A16-5.5 × 215 SXC14-S16-5.5 × 215 — TDB-S-S16-6.3 × 215
200 SDT14-A16-5.5 × 236 SXC14-S16-5.5 × 240 — TDB-S-S16-6.3 × 215
25 — — TI-A16-6.3 × 65 DT-S-S16-4.8 × 64
40 — — TI-A16-6.3 × 75 DT-S-S16-4.8 × 89
50 — — TI-A16-6.3 × 85 DT-S-S16-4.8 × 89
60 — — TI-A16-6.3 × 95 DT-S-S16-4.8 × 115
70 — — TI-A16-6.3 × 115 DT-S-S16-4.8 × 115
CONCRETE 1) 80 — — TI-A16-6.3 × 115 DT-S-S16-4.8 × 115
100 — — TI-A16-6.3 × 135 DT-S-S16-4.8 × 140
120 — — TI-A16-6.3 × 155 DT-S-S16-6.3 × 178
150 — — TI-A16-6.3 × 195 DT-S-S16-6.3 × 203
170 — — TI-A16-6.3 × 213 DT-S-S16-6.3 × 229
200 — — TI-A16-6.3 × 235 DT-S-S16-6.3 × 254
25 SDTW-A16-6.5 × 75 SXCW-S16-6.5 × 90 — TDA-S-S16-6.5 × 64
40 SDTW-A16-6.5 × 75 SXCW-S16-6.5 × 105 — TDA-S-S16-6.5 × 90
50 — SXCW-S16-6.5 × 105 — TDA-S-S16-6.5 × 90
60 — SXCW-S16-6.5 × 115 — TDA-S-S16-6.5 × 100
70 SDTW-A16-6.5 × 115 SXCW-S16-6.5 × 135 — TDA-S-S16-6.5 × 115
TIMBER 80 SDTW-A16-6.5 × 135 SXCW-S16-6.5 × 135 — TDA-S-S16-6.5 × 127
100 SDTW-A16-6.5 × 135 SXCW-S16-6.5 × 185 — TDA-S-S16-6.5 × 152
120 — SXCW-S16-6.5 × 185 — TDA-S-S16-6.5 × 178
150 — SXCW-S16-6.5 × 205 — TDA-S-S16-6.5 × 215
170 — SXCW-S16-6.5 × 235 — TDA-S-S16-6.5 × 215
200 — SXCW-S16-6.5 × 275 — TDA-S-S16-6.5 × 250
6.40
Fastener Selection
Guide SFS intec
Note:
*) Screws are regulated in Germany by Z-14.4-407. This approval provides only the use of corrosion-resistant fasteners before, what the use of steel for outdoor
applications excludes.
1) A direct anchoring in concrete structures is not currently regulated in Germany.
KS1150 TL
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1150 FR
Standard* High Wind Load* (depending on wind loading / building location & size)
KS1000 RW
Standard* Ridge / Eaves*
KS1150 FA
Standard* High Wind Load* (depending on wind loading / building location & size)
6.41
Fastener Selection
Guide SFS intec
6.42
Fastener Selection
Guide SFS intec
6.43