1. ALL WORKS SHALL CONFORM IN ACCORDANCE WITH THE LATEST EDITION OF PHILIPPINE ELECTRICAL CODE, C1 S1
THE RULES AND REGULATIONS OF LOCAL AND NATIONAL AUTHORITIES CONCERNED WITH ENFORCEMENT OF CR CR
C2
RULES AND REGULATIONS OF LOCAL UTILITY COMPANY.
7.6m 7.6m
2. ALL MATERIALS AND EQUIPMENT SHALL BE BRAND NEW AND APPROVED FOR THAT PURPOSE. C6
S1
3. ALL ELECTRICAL CONDUCTORS TO BE USED SHALL BE STRANDED COPPER AS MANUFACTURED BY ANY ACU 2
C4
APPROVED BRAND. ATM
ELECTRICAL
S1
4. SWITCHES AND CONVENIENCE OUTLETS SHALL BE RATED 10 AND 15 AMPERES RESPECTIVELY, 240 V, FLUSH
ATM ATM
TYPE.
S3
A. PANEL BOARDS
B. LIGHTING SWITCHES
1.7m ABOVE FINISHED FLOOR LINE.
1.4m ABOVE FINISHED FLOOR LINE. LIGHTING LAYOUT POWER LAYOUT
C. CONVENIENCE OUTLETS & AUXILIARY OUTLETS 0.3m ABOVE FINISHED FLOOR LINE.
D. MAIN DISTRIBUTION PANEL 1.0m ABOVE FINISHED FLOOR LINE.
6. EQUIPMENT GROUND WIRE SHALL BE COLOR GREEN AND THIS COLOR SHALL NOT BE USED ELSEWHERE.
SCALE: 1:80 SCALE: 1:80
7. EFFECTIVE GROUNDING SYSTEM SHOULD BE PROVIDED IN ACCORDANCE WITH THE PROVISIONS OF PHILIPPINE
ELECTRICAL CODE.
2 KWH ILECO II
2 - 14mm THHN CU. WIRE
8. ELECTRIC SERVICE SHALL BE OVERHEAD, 230 V, 1-PHASE, 2-WIRE, 60 CYCLES PER SECOND. M SERVICE ENTRANCE
SINGLE PHASE, 230V
9. BRANCH CIRCUIT PROTECTION, CONDUCTORS, CONDUIT PIPE, ETC. SHALL BE BASED ON THE SCHEDULE OF KWH METER
LOADS AND SINGLE LINE DIAGRAM.
10. BRANCH CIRCUIT HOMERUNS SHALL NOT BE COMBINED IN THE SAME RACEWAY AND RACEWAY FOR AUXILIARY
LINES SHALL NOT CONTAIN POWER LINES. 60AT, 2P
SINGLE LINE DIAGRAM
11. TYPE OF WIRING SHALL BE CONCEALED ON WALLS AND CEILING FOR LIGHTING AND POWER LOADS.
C1 C2
15AT, 2P 20AT, 2P
12. MAIN CIRCUIT BREAKER SHALL BE 60 AT, 240 V, 1O K.A.I.C., 2P PLUG-IN TYPE.
C3 C4
20AT, 2P 20AT, 2P
13. SERVICE ENTRANCE CONDUCTOR SHALL BE 14mm2 THHN COPPER WIRE IN 32mm dia. uPVC CONDUIT TYPE.
C5 C6
20AT, 2P 30AT, 2P
LEGEND C7
30AT, 2P
PREPARED FROM THE OFFICE OF: CERTIFIED AND SEALED BY: P. R. C. NO.: PROJECT TITLE: APPROVED BY: SHEET CONTENTS: SHEET NO:
P. T. R. NO.: SPECIFICATIONS
T. I. N. NO.:
ONE STOREY RESIDENTIAL LEGEND
LIGHTING LAYOUT E
1
ELECTRICAL ENGINEER
ADDRESS:
DATE: BUILDING POWER LAYOUT
SINGLE LINE DIAGRAM
1
SCHEDULE OF LOAD AND DESIGN
MOBILE: ISSUED: LOCATION: OWNER DRAWN BY:
EMail: PROFESSIONAL ELECTRICAL ENGINEER ANALYSIS