Professional Documents
Culture Documents
13-Purlins Upn Channel
13-Purlins Upn Channel
Job Ref.
Engineering Consultants Group CHECKING AND PACKING HALL
Bldg. 2, Block 10, El Sefarat District Calc. By Date Checked By Date Rev.
PURLINS ID :- ( P-1 )
Span = 11.00 m
Spacing = 2.00 m
α = 10.00
Using tie rods = No tie rod
1)- APPLIED FORCES :-
DEAD LOAD
O.W of C.sheets = 20.00 Kg/m2
WDL = 40.62 Kg/m\
WXDL = 0.0855 t/m\ WYDL = 0.0151 t/m\
MXDL = 1.2932 m.t MYDL = 0.2280 m.t
QXDL = 0.4702 t
LIVE LOAD
a)Uniform load
Roof is inaccessible
L.L. = 48.24 Kg/m2
WLL = 96.49 Kg/m\
WXLL = 0.0950 t/m\ WYLL = 0.0168 t/m\
MXLL = 1.4372 m.t MYLL = 0.2534 m.t
QXLL = 0.5226 t
b)100 Kg concentrated load
PX = 98.48 Kg PY = 17.36 Kg
MXLL = 0.2708 m.t MYLL = 0.0478 m.t
QXLL = 0.0492 t
MAX LIVE LOAD :-
MXLL = 1.4372 m.t MYLL = 0.2534 m.t
QXLL = 0.5226 t
WIND LOAD
Ce = -0.60
K = 1.10
q = 50.00 Kg/m2
WXWL = -0.3743 t/m\
MXWL = -5.6614 m.t Neglect wind load
QXWL = 0.00 t
2)-CHOICE OF SECTION :-
U.P.N. 300
Shear Stress
qw = 0.26 t/cm2 < 0.35xFy SAFE
h
4)- CHECK DEFLECTION :- X
W