Culture Documents
Currently Used on YCI Modification required on YCI Impact for YCI if followed
or Dimension 29CFR1910 - OSHA 29CFR1910 - OSHA
1910.23(e)(2) 1910.29(f)(1)(ii)(B) Update standard drawings
Guard Height Max 34", 34" 42", 42" Update of Vendor information
Min 30". 1910.29(b)(1), 42" +/- 3". Price impact of vendor???
1910.29(f)(1)(iii)
Not Permitted (Additional rail
Combined Guard/Handrail Height Permitted. Permitted Not permitted after 17Jan17 per
Stair system
1910.23(e)(2) 1910.29(f)(1)(i)
34" (Combined guard and Additional Hand rail at a height of
Hand rail height Max 34", Min 30"
handrail) 34" from walking surface
Min 30". Max 38"
1910.29(b)(9),
1910.23(e)(3)(i),
1-1/2" nominal schedule 40 pipe, Minimum 0.25 thickness or dia. 1-1/2" nominal schedule 40 pipe,
Minimum 1-1/2"nominal diameter.
Midrail Located midway between top 1910.29(b)(2)(i), Located midway between top
1910.23(e),
edge and floor (1'-5" from floor) Mounted midway between top edge and floor (1'-9" from floor)
Mounted aproximately midway.
edge and floor.