VACCUM EQUIPMENT 4

Vacuum generators GVS series

Type................................. Venturi effect vacuum generator


Fluid................................. Filtered compressed air
(lubrication not recommended)
Installation position.......... Any
Nozzle.diameters............. Blast nozzle: 1 mm
Injector nozzle: 2,5 mm
Port size.......................... G 1/4”
Working pressure............ 1,5...10 bar (22...145 psi)
Rated temperature.......... -20...80 °C (-4...176 °F)
Materials.......................... Aluminum housing and nozzles

Note: it is recommended to attach a silencer to the exhaust port for noise reduction.

1: Air supply
2: Exhaust
0.400.001.100 3: Vacuum
Aspirating flow (Nl/min)

Air consumption (Nl/min)


Vacuum (bar)

Pressure supply (bar) Pressure supply (bar) Pressure supply (bar)

4.1.1.1
Vacuum generators Push-in series

Type................................. Push-in connection venturi effect


vacuum generator
Fluid................................. Filtered compressed air
(lubrication not recommended)
Installation position.......... Any
Connections.................... Push-in Ø4 mm (male-female-female)
Push-in Ø6 mm (female-female-female)
Working pressure............ 2...8 bar (29...116 psi)
Rated temperature.......... -5...50 °C (23...122 °F)

4
Ø

4 0.481.545.001
6 0.481.545.005
Aspirating flow (Nl/min)
Vacuum (bar)

Pressure supply (bar) Pressure supply (bar)

4.1.4.1
Suction cups VN series

Type................................. The suction cups can be used to pick up


and hold workpieces with smooth and
impervious surfaces
Fluid................................. Filtered compressed air
(lubrication not recommended)
Working position.............. Vertical (preferrable)
Connections.................... M5, G1/8” and G1/4” (according cup size)
Vaccum rate..................... 0...-1 bar
Rated temperature.......... -20...80 °C (-4...176 °F)
Materials.......................... NBR suction cup, aluminum connection
(zinc alloy for Ø 75 and 100 mm cups)

Note: it is recommended to mount suction cups using suction cup holders CV series (see
page 4.2.2.1).

4
Type ØD Effective Ø A B ØR

VN 8 8 0.400.001.112 5,5 14 5 M 5 x 0,8 8


VN 15 15 0.400.001.113 12 20 8 G 1/8” 13
VN 30 30 0.400.001.114 25 20 8 G 1/8” 13
VN 40 40 0.400.001.115 32 30 10 G 1/4” 17
VN 55 55 0.400.001.116 44 30 10 G 1/4” 17
VN 75 75 0.400.001.117 60 30 10 G 1/4” 19
VN 100 100 0.400.001.118 85 30 10 G 1/4” 19 Ø 8-15-30

Ø 40-55
Theoretical suction force (N)

Theoretical suction force (N)

Vacuum (bar) Vacuum (bar)

(1) VN 8 Ø 75-100
(2) VN 15
(3) VN 30
(4) VN 40
(5) VN 55
(6) VN 75
(7) VN 100

4.2.1.1
Suction cups holders CV series

Type................................. Suction cup holders allow to compensate and


regulate suction cups position in a device
Fluid................................. Compressed air
Working position.............. Vertical (preferrable)
Connections.................... M5, G1/8” and G1/4” (according holder size)
Rated temperature.......... -20...80 °C (-4...176 °F)
Materials.......................... SAE 1020 zinc plated body, brass mounting
nuts

Note: use each suction cup holder only with the recommended suction cups sizes.

4
Type Suction cup Ø ØA B C D E F ØR
1 2

CV 8 0.400.001.119 8 M 12 x 1 67 12 25 4 12 8 8 M5
CV 30 0.400.001.120 15 / 30 M 16 x 1,5 88 17 30 5 14 14 13 G1/8”
CV 55 0.400.001.121 40 / 55 M 22 x 1,5 109 24 40 5,5 14 17 17 G1/4”
CV 100 0.400.001.122 75 / 100 M 22 x 1,5 109 24 40 5,5 16 17 17 G1/4”

4.2.2.1
Signal emitters Vacuum switches

Type................................. Vacuum switch emits a pneumatical or


electrical signal when vacuum is present.
The switching vacuum level can be adjusted
Signal type....................... Pneumatical or electrical. The electrical
model has both NA and NC contacts, 5A and
220V resistive
Fluid................................. Filtered compressed air (lubrication not
recommended)
Nominal flow.................... 200 Nl/min (at 6 bar)
Hysteresis........................ 80 mbar (pneumatic) - 250 mbar (electric)
Mounting.......................... Sub-base mounting (see sub-bases below)
Electrical output model: on DIN rail
Adjust. of switching pressure... -0,1...-0,9 bar (pneumatic output)
-0,3...-0,8 (electric output)
Degree of protection........ IP20 (electric output)
Rated temperature.......... -5...50 °C (23...122 °F)

4
NC NA
(Positive) (Negative)
Pneumatic signal 0.481.505.110 0.481.502.110

Electrical signal 0.481.513.522

Sub-bases
Ø4 mm tube push-in connections included

Single sub-base Single sub-base or end Manifold sub-base for


with rear connection base for DIN-Omega EN DIN-Omega EN 50022
0.481.532.001 0.481.532.104 50022 profile 0.481.532.102 profile

4.3.1.1