You are on page 1of 5
CREATE CLEAN AND SMe Sa Se ese pa eer rE en Beets Beemer Ce nn Rens nei Rte ocean g Seen RU ee ena ec STC Nea Tice earner + the use of " heat recovery" leads to significant energy saving and reductions of heat loss; Seeman neue mac ec Cea og ee ees many of his health problems are caused by air in his own home or workplace. Ithas been shown that the air quailty in our well sealed and wel-insulated homes ES one eae ie ao ee eases Cee eee ee ar cu) of fiters the airis purified from dust, soot, bacteria, etc. When needed in the cold winter days the incoming air is heated to room Ort Hydrostatic system controls humidity, keeping itn the range below 75%, whick limits the humidification and aging of the premises, and prevents the formation of ee The built-in ionizer fils the air with negative ions, which has antiseptic effect, kills Ce er eee coe ea) Pens ee earn ee ac ee eee coed rR Reece ene cay The airflow system "Eco-Fresh 01 LUX” is composed of: Abb. 1 /Remote control / 41, Outer protective grile protects the system from humility even during heavy rains. 2, Extensible aie fur allows regulation of the system length, depending on wall thickness, 3. Exhaust fan 5-speed, allows regulation of fan duty rom 35m in night slent made, up to 85m in day mode, 4. Filter with charcoal - guarantees the clean airlow even in strong polluted urban areas and industrial egions. Cleans the ai rom smell, dust bacteria, soo, car exhaust gases and other 5, Heal exchanger — conirbules to sigifeant reduction of heat loss during vention, 6. onizer— fing up the ar with negative ions 7. Blast fan ~ 5-speed, allows regulation of fan duty from 36m in ight silent mode, up to 8Sm"mh in day mode. 8, Decorative gle ~ does not take any space inthe room, canbe executed in diferent colors 8. Control unit wth humicty sensor ~ sitches on the ventilation when humidity exceeds 75% 410, Ceramic heater (Heater wih postive temperature coefcient, selt-regulaing(50~400W) and economical) 11. Remote control (Fig): starisiop @) ~ suis ono he sytem AIR FLOW == “Mode (reversible ventlation with thermal energy recovery) ‘The system biasts clean air from outside to inside and d'sposes polluted ar out ofthe room. Aheat recovery is observed — process of recovering hea from outgoing warm but polluted arr. The warm air which is going out trough exchanger i rendering is heat tothe incoming clean ai. ‘This continues toa significant eduction of heat loss curing winter days. In summer the opposite process is observed - the coo ai from air-conditioning whichis going out through exchanger is ching the incoming clean but warm air, In the exchanger is achieved effciency of heat regeneration that exceeds 90%. AIR FLOW —=— ‘made “Air Infx’— the eystem is constant submiting clean air rom outside ta inside. The heater can be switched on only in this mode and elivers fresh air with temperature 23°C. AIR FLOW— mode “Air Exhaust" ~ by protracted press over 10 seconds the system is working aa fan SLEEP in sloop mode and without ight inthe room the system tums of automaticaly after 10 minutes, [At ightening the system wil bain working mode after 2 hours retaining the previous settings. ‘STANDBY Heater, fan and ionizer are stopped. But the hydrostatic system monitors the humiily and wher i excaeds 75% the fan and ionizer are ‘sutomaticaly switched on. They stop working 10 minutes after the humid level crops below 75% FAN SPEED ‘operate the fan speed. A selection between 6 speeds ~ fi speed ~ 35m" in night silent mode, and last ith speed ~ max. mh in day mode. ONIOFF 4 - switch onfff the hydrostatic system: ONIOFF © - switches onfoff the ionizer, ONIOFF 3 - switcnes on/off the mode “heating of incoming ai CAUTION: only AIR FLOW == must be used with working fireplace, From producer: \With unit fireplace "Eco-Fresh 01 LUX" is recommended to work in AIR FLOW <= mode a fst speed 24 hours 9 day. LIGHT EMITTING DIODES Green diode + when isnot Ft the system does not work (or work as a fen) Air Flow —— when itis “the systom isin mode Air Flow === “ifflashes the system is in mode Alr Flow <== Red diode + when is not Ft the heaters off whan iti it “the system is in mode of heating the air, but the heater dass not operate if the temperature of incoming aris over 23° =i flashes the incoming air temperature Is below 17°C (ony in mode “Arr Influx") Blue diode ‘when isnot litte lonzer i of + when its it the ionizer is on Orange diode ‘When Is not tthe humidity sensor i of When itis it “the system isn mode of controling the humity when flashes the humidity level exceeds 70% atures in Standby made are lit green, blue and orange diodes, andthe system is not working if the humicty is below 70%. When the humidity exceeds that level the ionizer and fan slat working automatically on speed 3. The sensor monitors the humidly and 10 minutes after itis reduced below 70% the ionizer anc fan stop working: - The heator can be optionally switched on (fed diode i It), which guarantoes warm ai invtow when the system Is working du to high humidity. “Desired combination of functions can be chosen from the remote conta Technical data acs Fan (ea Cee) Dimensions / mm/ @100 o150 min270 / max 500 imal wall thickness 27 cm. ‘Maximal wall thickness 50 cm. “The elaboration ofa ventilation system, adjusted to other than the above wall thickness is possible by a clients request. Fy Eieaterr eee eri See U eee ae ae ee)

You might also like