You are on page 1of 4
6406-001 (andar out 08-1001 paar output) Eliminates Ground Loops Field Configurable Input Ranges: 10mV to 100V, mA to 100mA Field Configurable Output Ranges: 0-5V, 0-10V, O-1mA, 0-20mA, 4-20mA, +5y, +10V ULTRA SLIMPAK® G408-0001 & G408-1001 DC Powered DC Input Field Configurable Isolator Provides a Fully Isolated DC Output in Proportion to a DC Input Ai; CE Ultra Slim Housing for High Density Installations Flexible Power Supply Accepts 9 to 30 VDC ASIC Technology RoHS Compliant Description The Ultra SlimPak G408 is a DIN rail mount, DC input signal conditioner with 1200VDC isolation between input, output and power. The field configurable input and output offers flexible, wide ranging capability for DC current and voltage signals. Theinput can be configured for any one of 12 voltage ranges from Om to 100V oF & current ranges from ImA to 100mA (see Table 1). The output is linear to the input and can be set for either O- 5V, 0-10V, O-1mA, 0-20mA or 4-20mA (for models G408-0001) and-5 to #5V oF -10 to +10V (for model G408-1001) Wide ranging, precision ero and span pots allow 50% adjustability of offset and span turn-down within each of the 18 switch selectable ranges. For example, the 0-2mA input range could be turned down to 0-ImA and provide a full scale output signal (eg 4-20mA), or turned down and offset to achieve a 1-2mA/4-20mA VO combination. ‘The G408 aso accepts bipolar inputs (eg. 10V range set to bipolar = =10 0 +10V) and offers selectable normal or reverse operation (eg, 4-20mW20-4mA).The ASIC based VO channel is opticaly isolated to 1800VDC and is transformer isolated from the power supply. Application “The G408 is useful in eliminating ground loops, converting signal levels, and providing signal drive. The field configurable, wide ranging capability ensures maximum flexibility for most OC to DC applications, minimizing spare part requirements Diagnostic LED The G408s equipped with a dual function LED signal monitor. The green, front mounted LED indicates both DC power and input signal status. Active DC power is indicated by an illuminated LED. Ifthe input signalismore than 110% ofthe fullscale range, the LED. will lash at 8H, Below -10%, the flash rate is 4Hz Configuration ‘The G408 has 18 input range settings. Trim potentiometers allow 50% input zero and span adjustability within each of the 18 full scale input ranges. Unless otherwite specified, the factory presets the Model G408- (001 and G408-1001 as follows: 408-0001 Input Range: ‘output Range: 420m 4208 6408-1001 Input Range: ‘output Range: 420A “10 to +10, The DC power input accepts any source between 9 and 30V; typically 8 12V or 24VDC source is used (see Accessories) Tominumize interference from electrical and magnetic fields, the use of shielded, twisted pair wires on the input and output is recommended. WARNING! Do not change switch settings with power applied, Severe damage wil result! Refer to Tables 1 through 4for the proper switch settings. Use the switches on SWI to select the input type (voltage or current) and also to select the desired input range and function setting. Use ‘SW2 to select the desired output type. EUROTHERM Figure 1: G408 Block Diagram Table 1: G408 Input Range Settings Ranges Selector SWI covet 1] 2[ 3] 4 ama ale Smal | zomal [a] somal [ofa e joa Table 2: G408 Function Settings Selector St s[s[7]s ‘riparia Reverse Ovpull | = ret nput * Votage nou = ON or Coed Calibration 1LAfter configuring the DIP switches, connectthe inputto.acalibrated DC source. Connect the output to the actual device load (or a load approximately equivalent to the device load) and apply power. Note: To maximize thermal stability, final calibration should be performed inthe operating installation, allowing approximately 1 to 2 hours for warm up and thermal equilibrium of the system. 2,Setthe calibrator to the desired minimum Input and adjust the eto potentiometer for the desired minimum output. 3, Setthe calibrator to the desired maximum input and adjust the span potentiometer for the desired maximum output. 4, Repeat steps 2 and 3, as necessary, for best accuracy, Table 3: 6408-0001 Output Settings ‘408-0004 Selector SW2 Renoes [a] 2] 3] «[ slo] 7] 8 rr fel] ow 107 fal dwimal_[afel = 020m tele 210208] @| © =e Table 4: 408-1001 Output Settings ‘oaoo-t00r | Selector SW Ranges [9 [10 BV 0 +8 . “ovt0+10V Koy m1 = ON or Closed Figure 2: 6408-0001 Factory Cal; 4-20mA, Unipolar Input, Normal Operation, 4-20mA Output. Figure 3: 6408-1001 Factory Cal: -20mA, Unipolar Input, Normal Operation -10 to TOV Output oviot() 2. PBB] St ovine Dein) 42 Poe] =A! OC won) are = ° 2 2] oc Power) 12_ FggH 11 0c Pover Dc Power) 22. FEO] «21 DC Power (+) Figure 4: Wiring Diagram for 6408-0001 and G408-1001 os: At Ui SinPak mods ae desired to pean ait ‘Swoon 5° wan mer a Wa ‘asin (o721-906.20) oF conta tay Sor asssance Figure 5: Mounting Multiple Modules Specifications Input: Voltage: Vottage: Range Limits 10m to 100 Impedance: >100K Ohms Output aoe-1001): ‘Output -5V to 5,10 to +10 Source Impedance: <10 Ohms Drive: 10mA, max Humigity (Nor-Condensing): Operating: 15 to 953 @ 45°C Soak: 90% for 26 hours @ 65°C ‘Temperature Range: Operating Oto $5°C G2 to 131°F) vervotage: LED Indication (greer Storage: -25 to 70°C (13 to 158'F) 400 Ves, max lntermitend, Input Range Wire Terminals: 264 Vimsmax (Continous) >10Rappron input fash ‘Screw termina for 12-2206 current: < -1O€appro¥ input: 4 flash Power: Range Limits: Im to 100m Impedance: 20 Ohms. ypc ‘Overcurrent: 170m RMS, max (vervoltage:6OVOC Zero TurnUp:50% of fl sae input Span Tutn-Donm: SOR of ull ale input (Cmmen Mode putt Gd 1800 0G mae output (6408-0000): Voltage: Output 0-5, 0-10 Source impedance: <10 Ohms Drive: 10maA, max. current (Output OIA 4. 20mA0-20mA ‘Accuracy (Including Linearity, Hysteresis) amA/amA>20niV 01% of fl sae ‘typical 02%, max Response Time (10-50%): 200mSec, typial Stability (emperatu 00254 ofl cc ypc 40054C, max ‘Common Mode Rejection: DC to 60He: 10048 ation (Input to Outpud): ‘18OOVDC between input, output & power EMC Compliance (CE Mark): ‘Consumption: 15 typical, 25 max Range: 9 to 30V0C Weight: 05 ths, ‘Agency Approvals: UL recognized pe standard ULSO8 le No £98775). (CConfermarce per NC rcv B/367EC nd Low Wattage 3/2378 AUnput-<75¥DC. on. Rots Compliant Emissions: ENSOOS-1 Source impedance: >100K Ohms Compliance: D-ImA 75, max 0.5K Ohms) Irvmunty ENS0082-2 Safety ENSOT78 ‘Mean Time Between Fares: {-20mA:12V, max 00 Ohms) 0-20mA: 12V, max (600 Ohms) cok Hours Ordering Information Models & Accessories Speci To Modet Ga0e.0001 standard outputs) oF {G408-1001 bypolar output) 2 Accessories: (se Accessories) 53. Options custom Factory Calbration: spety C520 with desired input and output ange Accessories SimPak"G* sees medules will mount an standard 7832 (model MDO2) (0 TS35 (model M03) DIN ral and include model HSOT heatsink. In Seton, the folowing accesories ae avaiable MDO3 1535475 DIY rail. W305. 24V3CPoner Supply (05 Amp) 1H9t024VDC Power Supply (1 Amp) BIS 24VDC Power Supply (23 Amp) MB03 End Gracket for MODS 664 VO Deserve Tags 6006 01 Ohm SH 1K shunt resistor Dimensions Toomin Scrws We Ey apacees) —(¢tach as) | BleurotHerm ae Eurotherm, Inc TAL ler ve lnfoseurotherm com or woa.eurotharmconvectione Factory Assistance For additional information on cabbration, operation and instalation contact our Technica Services Group 703-669-1318 ‘actionsupport@eurotherm.com 1721.0657-004 02/09 Copyright Eurotherm, ne 2009 ‘Aetion Instruments Barber-Colman + Chessell + Continental + Eurotherm

You might also like