‘Section 900 Quality Control for Road Works
S. | Type of Construction Test Frequency (min)
No.
vii) Soundness(Magnesium — |Same as mentioned under Serial No. 2
Suiphate and Sodium
Sulphate)
ix) Polished stone value |Same as mentioned under Serial No. 2
x) Temperature of binder at | At reguler interval
application
xi) Binder content ‘Two tests per day per plant
xi) Peroentage of fractured | Same as mentioned under Seriat No. 2
faces
4) [Bituminous Macadam |i) Quality of binder ‘Same as mentioned under Serial No. 4
ji) Aggregate Impact Value or | Same as mentioned under Serial No. 2
Los Angeles Abrasion Value
ii) Combined Flakiness and | One test per 350 cu.m for each source
Elongation Indices
iv) Stripping value [Same as mentioned under Serial No. 2
Vv) Water absorption of [Same as mentioned under Serial No. 2
‘aggregates
Water Sensitivity of mix
Grading of aggregates
‘Soundness (Magnesium
‘Sulphate/ Sodium Sulphate)
Percentage of fractured
faces
‘Same as mentioned under Serial No. 2
|Same as mentioned under Serial No. 2
‘Same as mentioned under Serial No. 2
[Same as mentioned under Serial No. 2
1x) Binder content ‘Same as mentioned under Serial No. 3
x3) Control of temperature of | Same as mentioned under Serial No. 2
binder and aggregate for
‘mix and of the mix at the
time of laying and roling
i) Density of Comp layer —_| One test per 700 se.m area
xl) Rate of spread of Mixed [At regular intervals
Material
5) [Dense Bituminous |i) Quality of binder Number of samples per lot and tests as per
/MacadamiBituminous 18:73 or IRC:SP:53, 18:15462
‘Concrete
§) Aggregate Impact Value/ | One test per 350 cu.m of aggregate for
Los Angeles Abrasion Value | each source and whenever there is change
in the quality of aggregate
i) Flakiness and Elongation | One test per 350 cu.m of aggregate for
Indices Jeach source and whenever there is change
in the quality of aggregate
¥) _ Soundness test (Sodium or | One test for each source and whenever
Megnesium Sulphate test) |there is change in the quality of aggregate
'v) Water absorption of JOne test for each source and whenever
aggregates there is change in the quality of aggregate
424