Professional Documents
Culture Documents
SPAM150C - Motor Protection Relay PDF
SPAM150C - Motor Protection Relay PDF
Product Guide
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide Issued: April 1999
Status: Updated
Version: C/19.04.2006
Data subject to change without notice
Features • Versatile multifunction relay for the protec- • Continuous self-supervision of hardware
tion of circuit breaker or contactor con- and software
trolled a.c. motors
• Current range handled meets the require-
• The relay can also be used for the protec- ments for ExE motor drives of Zone 1
tion of feeders and transformers
• Sophisticated self-supervision system with
• Three-phase thermal overload protection auto-diagnostics
• High-set overcurrent protection with instan- • Interface for extensive data exchange with
taneous or with definite time operation the substation level data acquisition and
control system over fibre-optic bus
• Phase unbalance and single-phasing pro-
tection with inverse time characteristic • Powerful software support for parametriza-
tion of the relay, for reading measured and
• Fast operating incorrect phase sequence
recorded values, events, etc. and for stor-
protection
ing readings
• Sensitive earth-fault protection with definite
• Member of the SPACOM product family
time characteristic
and ABB’s Distribution Automation system
• Undercurrent protection with definite time
• CE marking according to the EC directive
characteristic
for EMC
• Several selectable motor start-up supervi-
sion methods
Application The numerical motor protection relay available in two versions, one with a making
SPAM 150 C is an integrated design current trip contact and the other with a breaking trip
measuring multifunction relay for the com- contact.
plete protection of a.c. motors. The main area
of application covers large or medium-sized The relay can also be used for the protection
three-phase motors in all types of conven- of other objects, such as transformers and
tional contactor or circuit-breaker controlled feeders, requiring a single-, two- or three-
motor drives. The motor protection relay is phase overcurrent and/or overload protection
and non-directional earth-fault protection.
3
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
The undercurrent unit is used for the protec- The auxiliary power modules also hold the
tion of motors at sudden loss of load in cer- output relays of the relay. The types
tain applications, such as conveyors and SPTU 240R2 and SPTU 48R2 incorporate a
submersible pumps. The unit features definite normally open trip contact and the types
time characteristic. SPTU 240R3 and SPTU 48R3 a normally
closed trip contact.
4
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
5
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
Technical data (cont´d) Table 4: Motor protection relay module SPCJ 4D34
Thermal overload Full load current Iθ 0.50…1.50 × In
unit Weighting factor for thermal unit curves p 20…100%
Safe stall time setting t6x, i.e. trip time at locked rotor from cold 2.0…120 s
motor
Cooling time multiplier kc, for motor at standstill 1…64 × τh
(τh = heating time
constant)
Thermal prior alarm level θa 50…100% of θt
(θt = thermal trip
level)
Motor restart inhibit level θi 20…80% of θt
Thermal initialization level on restoration of auxiliary supply 70% of θt, i.e. hot
motor
Start-up Start current Is 1.0…10.0 × In
supervision unit Start-up time ts 0.3…80.0 s
Two operation principles definite time
principle
(I & t)
thermal stress
principle
(I2 × t)
High-set phase Start current I>> 0.5…20.0 × In
overcurrent unit or ∞, infinite
Operate time t>> 0.04…30.0 s
Earth-fault unit Start current I0> 1.0…100% of In
Operate time t0> 0.05…30.0 s
Phase Start current ∆I 10…40% of IL
unbalance/incorrect (IL = Load current)
phase sequence Operate time t∆, at lowest possible setting, i.e. 10% 20…120 s
unit Operation characteristic Inverse time
Operate time at 100% phase unbalance (single phasing) 1s
Operate time at incorrect phase sequence 600 ms
Undercurrent unit Start current I< 30…80% of Iq
Operation inhibit level <12% of Iq
Operate time t< 2…600 s
Cumulative start-up Restart inhibit level of cumulative start time counter ∑tsi 5…500 s
time counter unit Countdown rate of start-up time counter ∆∑ts/∆t 2…250 s/h
6
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
7
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
Block diagram
L1
L2
L3
0 -
- I
I 0
+
Rx Tx
SPA-ZC
+ (~)
U +
- (~) aux ESIHÄLYTYS
UUDELLEEN- LAUKAISU-
OHJAUS- KÄYNNISTYS- START LAUKAISU- LAUKAISU
ESIHÄLYTYS HÄLYTYS 2 HÄLYTYS 1 SARJA-
TULO IRF LUPA LIITÄNTÄ-
+ PORTTI
Rx Tx
63 1 23 4 56 7 89 25 26 27 11 10 61 62 70 71 72 74 75 77 78 80 81 68 69 65 66
+ + + + + +
5A
5A
5A
5A
1A
1A
1A
1A
+ -
F E D C B A
U2 SPTU _ R2
TRIP
R
1 1 1 1 1
ITSEPITO
U1/SGR2/1
U1/SGR2/2
U1/SGR2/3
U1/SGR1/1
U1/SGR1/2
U1/SGR1/3
U1/SGR1/4
U1/SGR1/5
U1/SGR1/6
U1/SGR1/7
U1/SGR2/4
U1/SGR2/5
U1/SGR2/6
U1/SGR2/7
U1/SGR2/8
U1/SGR1/8
IRF
3 q>q
i
q>q a
q>q t
START
U1/SGB/1
JUMI I s2 t s
U1/SGB/2 UUDELL. UUDELL.
KÄYNNIST. KÄYNNIST.
ESTO ESTO
S ts >
I
ÐI
U1/SGB/3
Io>
U2/SGB/4
I<
U1/SGB/6 RELEEN
SPAM 150 C KUITTAUS I/O
U1 SPCJ 4D34
SPAM150block
SPAM150block
8
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
139 ±1
Panel cut-
136
162
out
dim100
Semi-flush mounting
a b
Raising frame a b
SFM100_1
SPA-ZX104 SPA-ZX110
SPA-ZX105 SPA-ZX115
SPA-ZX106
+0,4 158 263
482,6 –0 (19")
115
ø6
10
177 –0 (4U)
101,6
7
+0,4
312
292
21,5
6
115 98
104_6_10
Fig. 4 Mounting cabinets and frames as well as projecting mounting (dimensions in mm)
9
Motor Protection Relay SPAM 150 C
1MRS750384-MBG
Product Guide
Order numbers
Motor protection relays SPAM 150
SPAM 150 C with NO trip contact RS 641 014-AA, CA, DA, FA
SPAM 150 C with NC trip contact RS 641 015-AB, CB, DB, FB
The last two letters of the order number indicate the AA and AB equal fn = 50 Hz and Uaux = 80…265 V
rated frequency fn and the auxiliary voltage Uaux of ac/dc
the relay as follows: CA and CB equal fn = 50 Hz and Uaux = 18…80 V dc
DA and DB equal fn = 60 Hz and Uaux = 80…265 V
ac/dc
FA and FB equal fn = 60 Hz and Uaux = 18…80 V dc
References
Additional information
Manual “Motor Protection Calculation Tool for 1MRS 750593-EEG EN
SPAM 150 C”
Manual “Motor protection relay SPAM 150 C” 1MRS 750637-MUM EN
10
ABB Oy, Distribution Automation ABB Limited, Distribution Automation
P.O. Box 699 Maneja , Vadodara - 390013, India
FI-65101 Vaasa, FINLAND Tel +91 265 260 4386
Tel +358 10 22 11 Fax +91 265 263 8922
Fax +358 10 224 1094 www.abb.com/substationautomation
www.abb.com/substationautomation