I a ERS = (72.5-420 kV) = | ee, & } > GT1-125 p—- GT1-145 ; -GT1-170 t+ GT1-245 ;-GT1-300 ; > GT1-362 — GT1-420 EMEK ELEKTRIK ENDUSTRISi A.S. TY PE sicnation Inductive Voltage Transformers ; GT1-72.5 Inductive Voltage Transformers. : GT1-125 : GT1-145 Inductive Voltage Transformers : GT1-170 Inductive Voltage Transformers : GT41-245 Inductive Voltage Transformers : GT1-300 Inductive Voltage Transformers : GT1-362 Inductive Voltage Transformers : GT1-420 Inductive Voltage Transformers DESCRIPTION Production EMEK voltage transformers are manufactured in Ankara Turkey. Special Design Non standard core data, creepage, seismic, atc. designs are available on request. Standards All transtormers are subjected to full routine tests as describad in the relevant standards. Type tests can also be performed In our own testing laboratories but should be negotiated during the order slage. Quality Assurance Emak is 1SO 9001 certified by both ABS Qual Evaluation Inc. and TSE, Turkish Standards Institute. DAT Accauireo TO MAKE AN OFFER ———— General + Quantity * Insulation Level + Delivery Time: + Frequency * Destination « Number of Windings + Service Conditions» Voltage Ratio + Others + Rated Burden ElectriCal Data + Accuracy Class for Each Winding. + Standards + Voltage Rating Factor + Creepage Distance for Each Winding EE General Description * Primary and secondary windings are housed in a porcetain bushing. * Including and above 245 kV EMEK VT's are _twa piece designs, commonly known as ‘Cascade’. These are basically two independent VT'S connected in series. They ‘re named the top unit and bottom unl + Transformers are hermotically sealed. Frequency #50 Hz, 60 Hz Rated Secondary Voltage #11013, 10043 V'etc. in conformity with customer requirement. Rated Tertiary Voltage #110/N3, 1003, 110/3, 100/3, 100, 140 V etc. fn conformity with customer requirement, Highest System Voltage ‘+ Highest system voltage from 72.5 te 420 KV. Number of Secondary Windings * In conformity with customer requirements. Voltage factor 4.2.x Un continuous / 1.9 x Un for 30 sec, ‘Standards IEC, BS, ANSI, AS, other standards on request Hermetic Seal * Oil volume variations are compensated with stainless steel balinws placad in the head of the current transformers. ‘= With this facility there will be no contact between air and ol. * The dielectric strength will remain unchanged for the life time ofthe VT. a __— Primary Terminals. * Primary terminals are made from tin plated brass. * Vertical and horizontal primary terminals are available. * Dimensions of stud typa are 30x 80 im. Nema ped or amp type primary terminals are avallable on request Core * High quality stieet sleet cores. are used. Paper Insulation " Olimpregnated peper high alecc tang, low delectic losses. Bushing = ** Brown glazed porcelain (other colours on request). * Extra high creepage aistance is also possible on raquest. Oil Insulation ** The insulating oi! is mineral oil in conformity with IEC 296. Before impregnation, moisture and gases are removed from the oll by special processes, * Drain plug for taking samples and oll refiling facilities are, provided on request. * Floating type oll level indieatoris standard supply. ‘Oil Impregnation * Heat and vacuumiare applied ta the fully insulated windings afler assembly of the magritic unit for drying purposes, followed inimédiately by oil impregnation procedure. Accessories * Fixing holes, lifting holes, secondary terminal box, name Blate, warning plates are aso provided in our staridare ign. Secondary Terminal Box * Hinged type boxes are Used and aré sealable on request * Secondary terminals are-clamp type, other types are also available on request * Fuses or MB's are also available on request. Name Plate * Name plates are stainless stee! and weatherproof. Primary Windings + Enameled electrolyte copper wire is used for pamary windings of intermediate votlage transformer Secondary Windings + Enamelied ‘copper wire is used for secondary windings of intermediate voltage trafisformer. External Binding Elements, * All extemal bolts, nuts, washers atc: are either stainioss steel or hot dip galvanised steel. Painting + External surface of the transformers, which ara already Corrosion protected (e.g. by galvanising), are additional painted grey colour. Other colours are available on request, Earthquake Design + Standard design is up to 0.69. Mechanical Strength + Applied load to the primary terminal in horizontal and vertical is in conformity with IEC 6004.42 Ambient Temperature * Standard design is suitable for temperature range -25°C to0 *C Other ranges on requast. Altitude * Standard dasign is suitable up to 1000 m above sea level. Higher values on request, Bracelet * All bracelets used on transformers are made from aluminium alloy. ‘Optional Accessories » Steel support siructure Primary connectors * Marshailing box. Storage + itis recommended to store the transformers in their factory packed condition prior to installation. Packing * The transformers are packed in rugged wooden erates: ‘Which are suitable for transportation. + The transformers ore encapsulated in polyethylene covers to keep them from environmental effects such as rain‘, dust and sand etc. (during transport and storage) + Wooden crates can be lifted by elther a fork lit or by a Grane with slings, ‘Spare Part + There are_no user serviceable par, therefore no spare parts are required, Maintenance: ‘+ Maintenance free, simple recommendations > * A. Complete and thorough inspection should be carried out invevery year * Clean the porcelain bushiny al teyular intervals depending On the dagres of potlution, “Ensure that there is 110 oll ieakage. + Periodical measurement of capacitance and power factor are recommended, Special Tools + No special tools are required for the maintenance. Assembly € Foes assembly, the following visual chacks should be m ‘There are no oll leaks ‘+The poteelain is not damaged ‘There is no damage'on the primary terminals + The oll level indicator indicates sufficient oil evel + Lifting holes are provided on the base plate. These should be used for iting and assembly. TRANSPORTATION ‘Transportation is only possible in the upright (vertical) position. The VT should never be transported or stored in the horizontal position. The crates should not be put on top of each other. Attention should be paid to the red "UP" arrows on the crate. HANDLING For transformers which have been transported and/or stored in horizontal position for any reason, fectory level re- conditioning and testing is necessary. ‘The vehicle used for transportation must be of adequate size. The packing must be tightly secured to the chassis of the transportation vehicle. Hfunpaved and rough roads are to be travelled, care should be given to prevent rigorous vibration, Prolonged and rough vibration may lead to oil disturbances CORRECT MAX INCLINATION WRONG. ASSEMBLY NEVER Use the primary terminals, bracelets or porcelain bushing forlifting the transformers Lift the transformers d by using the holes : provided on the base. TE WRONG CORRECT | f MAIN FEATURES OF NOUC NOETAGr. 245 - 420 kV Cascade type inductive voltage transformers are made up from two individual and independent VT's which are connected in series. The upper and lower part have independent oll compartments therefore no oil connection is made between the units. Each unit has its own stainless steel bellow for compensating the change in the oil volume due to temperature variation. The height of the units is suitable for upright (vertical) transport on normal trucks and they will pass under standard bridges. This way complications of horizontal transport are avoided. Both units are assembled on site. Simple electrical connection is made between the upper part and the lower part. No special tools are required for connection. The line (and test) voliage is shared equally by both units. The insulation task of each unit is actually half of the task of a single piece unit. Therefore there \s considerably less strain on the insulation. Less insulation strain means longer life. Minimum ferrous surfaces are subjected to the environment to minimise corrosion. Ferrous surfaces are hot dip galvanised and painted. A & & - < Single line | . diagram ue of 5 cascade j iE a inductive voltage t i < transformer 2a mn 2 CROSS SECTION, INDUCTIVE VOLTA 420 kV VT 4 12 13. 14, 18. TRANSFORMERS 72.5-170 kV VT as 10] 1) Filing Tap ‘Aluminium Cover Stainless Steel Bellows Oi Laval indicator Primary Terminals Heac oi Primary Winding and Paper Insulation Magnetic Core Winding and Paper Insulation, Porcelain Bushing. ‘Secondary terminal box Lifing holes il Sampling Vave Base DATA, wes Desenation arts | ati25 | orttas | atia70 Highest System Votlage | WV | 726 | 123 [tas] 170 Rated Frequency Hz 50 or 60 | Fated primary Volage Kv ‘fom 60 KV up to 54K Rated Secondary Votage_| V | _100N6, 110A, 1008, 1108, 100,170 6a Test votages iy | wa0es [220860 | arseso | sesran Reted Votage Facior A | 4.2 Un Gontinicusri ox Un for30 sec Type of cannetion Phase to Ground Greopane isancet) | am | 160] paco [6600] a, Dimensions ~_[ mm | 1336 40 | _vea0 | 2205 B [mn] tao | 1640 | 1500 | 1908 & [mn | 900 | 1300 | 100 | ase ; o [mm] ms [7s [ae | avs (")Highor creepage distance are also avaliable on request ae Saati es Ee Highest System Voltage 300, 362] 420 Rated Frequency [ve 50 or 60 ates pray Votage [wv TORE Vip w OT Rated Secondary Voltage v 110W3, 100/V3, 10073, 110/3, 100, ect Test Vato hey faeonoso [siomt76 | sronaoo | esaraes fied Youge Fee 2 Conncue Creepage distance(") [mm | 4800 ‘6000 7240 Ea ar Aelia meas Soo [om | a aid iene aa [S| Galleri aoa | exces | neaeoe fear ‘00 [7600 | 800 (() Higher creepage distance are also avaliable on ales! ee BLES DATA, | PACKING DETIALS (Approximate values) “The eennicatanterane Diecsion ern) Weight imensions provided in Gross this document aro for ee | wef | wis ai GT1-72.5 ‘The exact data and GT1-125, dimensions can be GT1-145 verified once the client's GT1-170 fal specs are known, GT1-245 Upper Furthermore as efforts Lower are constantly made to GT1-300 Upper improve design and Lower methods of manufacture, GT1-362 Upper the equipment offered ese say difer fom the GT1-420 Upper equipment described in te this document, EMEK ELEKTRIK ENDUSTRISi A.S. Post Address: P.O Box 648, Ulus 08044, Ankara Turkey Factory Address : Esenboga Yolu 23 Km Cubuk Ankara Turkey Phone + 90312 398 07 95 398 07 96 398 05 05 Fax :+90312 398 07 58 e-mail emekeeas@ada.nettr web site :www.emek.com.tr September, 2004

You might also like