Professional Documents
Culture Documents
D e signatio n c o d e
M e asure m e nt
ac c ord ing to
MAES TR O
E TI CS GF
EN 13164
E TI CS BT
stand ard
300 - L
400 - L
500 - L
600 - L
700 - L
FAB R I C
300 - I
units
TECHNICAL DATA FIBRANxps
Thickness tolerance Ti T1 T1 T1 T1 T1 T1 T1 T3 T3 T3 EN
823
Thermal conductivity (after 90 days) λ 0,032 0,032 0,033 0,033 0,033 0,032 0,032 0,032 0,032 0,032
smooth surface WL( T )0,7 0 ,3 0,3 0,4 0,4 0,4 0,3 0,3
Long term water EN
absorption by vol.% 12087
total immersion rough surface WL( T )1,5 ≤1,5 ≤1,5 ≤1,5
Water absorption by diffusion WD( V )3 vol.% 1 ,5 1,5 1,2 1,2 1,2 1,5 1,5 EN
12088
Water vapour diffusion resistance factor MUi - 150-50 150-50 150-50 150-50 150-50 150-50 100-50 50 50 50 EN
12086
Tensile strength perpendicular to the faces σmt TR400 kPa >400 >400 >400 EN
1607
Linear coefficient of thermal expansion α+20-+70ºc - mm/mK 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075
E EN
13501-1
Reaction to fire - Class
B1 DIN
4102
MAES TR O
E TI CS GF
E TI CS BT
300 - L
400 - L
500 - L
600 - L
700 - L
FAB R I C
300 - I
FIBRANxps extruded polystyrene boards:
recommended applications
ROOFS
Green roofs
Roof terraces
FLOORS
Basement floors
Floor heating
Cold rooms
Skating rings
Antiseismic application
WALLS
Façade plinths
Sandwich panels
Thermal bridges (balconies, window and door jambs, concrete
columns and tie-beams
Internal walls located next to colder spaces
Thermal insulation in combination with gypsum boards
and other materials
Swimming pools
Foundation slabs
FROST PROTECTION
INDUSTRIAL APPLICATIONS
D e signatio n c o d e
M e asure m e nt
ac c ord ing to
FIBRANxps extruded polystyrene panels are produced with various physical characteristics, surface and edge formations to be
MAES TR O
E TI CS GF
EN 13164
E TI CS BT
stand ard
300 - L
400 - L
500 - L
600 - L
700 - L
FAB R I C
300 - I
suitable for different applications. They are the only boards capable of withstanding high levels of humidity and heavy loads.
units
TECHNICAL DATA FIBRANxps
FIBRANxps in a humid environment
Extruded polystyrene solved the problem of thermal insulation in environments with a high humidity index or presence of water.
FIBRANxps extruded polystyrene boards with their closed-cell structure are excellent for insulation of environments with high
Shape of edge profile L L L L L I D L L I humidity (basements, inverted roofs, indoor swimming pools, façades, etc.)
rough A small roof insulated with FIBRANxps ETICS FIBRANxps under heavy loads
Surface smooth sur face waffled sur face rough RECOMMENDED USES
sur face with sur face The closed-cell structure of extruded polystyrene boards gives the material a very high compressive strength. It can thus, be used
channels
in insulated floors which have to carry heavy permanent loads.
1250 1250- 1250 1250 1250 1250 2500 1250 2500 upon EN
Board’s dimensions mm /600 2500 /600 /600 /600 /600 /600 /600 /600 request 822
ROOFS:
/600 • Circumferential low walls of flat roofs FIBRANxps with processed surface
EN • Eaves of pitched roofs An Etics plinth façade with FIBRANxps ETICS ... is specially designed for applications combined with coatings (plasters, adhesives, etc.), glue and concrete. The advantages are
Thickness tolerance Ti T1 T1 T1 T1 T1 T1 T1 T3 T3 T3 823 high vapour permeability, adherence to coatings and concrete, maintenance of low water absorption, high compression and
WALLS:
tensile strength.
Declared compressive strength
• Façade plinths
CS(10\Y )i kPa 3 00 400 500 600 700 300 1 250-300 200-300 200-300 300-700 EN FIBRANxps extruded polystyrene products have obtained European
at 10% deformation 826 • «ETICS» - rendered façades
• Blind insulated formwork Technical Approval for External Thermal Insulating Composite
• Internal or sandwich wall insulation Systems - ETICS.
20 mm < d < 30 mm 0,033 0,033 0,033 0,033 • Thermal bridges (balconies, windows and
Declared
thermal conductivity EN door-jambs, concrete columns and tie-beams)
λD 12667 • Rendered internal walls next to cold rooms
(after 25 years)
W/mK
40 mm < d < 200 mm 0,035 0,035 0,035 0,035 0,035 0,035 0,035 0,035 0,035 0,035 FIBRANxps EXTRUDED POLYSTYRENE
INSTRUCTIONS FOR USE
EN All construction requirements should be taken into account during the application of FIBRANxps panels.
Compressive modulus of elasticity E - MPa 20 25 30 35 40 20 15 15 15 15 826 FIBRANxps panels should be placed on flat and clean surfaces. They can easily be cut using a sharp knife or heated wire.
Thermal insulation of thermal bridges (antiseismic An ETICS façade with FIBRANxps ETICS Most FIBRANxps product edges are “L”- or “D”-shaped. The panels are usually installed in a single layer. The application of a double layer is
EN
Shear strength τ - MPa 0,15 0,15 0,15 12090 tie-beams) with FIBRANxps ETICS desirable for “I”-shaped panels, to avoid the consequent formation of thermal bridges at the joins.
EN Thermal insulation in the reversed rooftop application should be installed in a single layer.
Shear modulus G - MPa 2,6 2,6 2,6 12090 No naked flames should be used during the installation of FIBRANstick extruded polystyrene panels. Whenever FIBRANxps panels are to
be applied over waterproofing film on basement walls, FIBRANstick adhesive tape should also be used. In the event of basements with a
Tensile strength perpendicular to the faces σmt TR400 kPa >400 >400 >400 EN high water table, the damp proofing product (e.g. tar) should be applied to the entire wall surface.
1607
When using FIBRANxps on larger surfaces, especially on warm flat roofs, the dilation or contraction of the panels due to temperature must
WALLS:
be taken into account. The construction of expansion joins with GEOLAN stonewool is recommended in such cases.
Linear coefficient of thermal expansion α+20-+70ºc - mm/mK 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 0,075 • Sandwich panels
Please note: The cross sections and compositions of construction details presented in the leaflet are indicative and should be adapted wherever
• Thermal bridges (balconies, window and
necessary.
Freeze-thaw resistance FT2 0,5 0,5 0,6 0,6 0,6 0,5 0,5 EN door-jambs, concrete columns and tie-
12091 beams) 3. PROTECTION AND DURATION OF APPLICATION
• Internal walls next to cold rooms It is recommended that applicators of FIBRANxps extruded polystyrene boards should apply all necessary self-protection measures when
Temperature range of use - ºC from -50 to +75 cutting with heated wire.
• Ιn combination with gypsum boards
E EN INDUSTRIAL USES:
13501-1
Reaction to fire - Class • Material to cut various profiles for civil
B1 DIN engineering and industrial applications FIBRANxps FABRIC internal thermal insulation The quality of FIBRANxps products is assured by EN 13164 and EN 13172 standards. These standards
4102 • Window and door frame filling establish the type and frequency of measurements executed by recognized and independent institutions,
in combination with gypsum boards
• Filling for door leaves (PVC doors) as well as by FIBRAN laboratories.
• Containers/vehicles FIBRAN S.A. shall not be held liable for any damage caused by improper use of the products,
transportation, storage and handling.
FIBRANxps is an environmental friendly material 1
Compressive strength of 200 kPa in the case of 20 mm thick boards
In the event of special applications, products with special dimensions can be produced.
Compressive strength of 250 kPa in the case of 30 mm thick boards
• Ship-lap edge, “L” profile • Smooth surface • Board’s dimensions: 1250 / 600 [mm]
Mechanical protection of the waterproofing Thermal protection of underground Thermal insulation of loaded floors with
membrane and simultaneous thermal protec- perimeter walls with FIBRANxps 300-L FIBRANxps 300-L
tion of a basement with FIBRANxps 300-L – inversed construction of a basement wall
FIBRANstick stickers are special butyl rubber sticker pads for fixing FIBRANxps thermal insulation
boards on waterproofing membrane in basement wall application. During the gluing process the
XPS boards as well as the waterproofing membrane must be clean and dry.
02
Construction of an inverted green roof
with FIBRANxps 300-L
ROOFS:
• Inverted warm flat roofs • PLUS roofs (renovations, energy class upgrade)
• Warm flat roofs • Green roofs
• DUO roofs (low energy and • Roof terraces A flat roof insulated with FIBRANxps 300-L
passive houses)
Fixing FIBRANxps 300-L boards with FIBRANstick sticker pads on the waterproofing membrane of a basement wall
03
XPS - EN 13164 - T1 - CS(10\Y)400 - DS(TH) - DLT(2)5 - WL(T )0,7 - WD(V)3 - FT2
• Ship-lap edge, “L” profile • Smooth surface • Board’s dimensions: 2500 / 600 [mm]
• Dimensions upon request: 1250/600 [mm]
EAN code
thickness of boards in one packages on one compressive
52053811____
in one package on one pallet strength
[mm] package [m²] pallet [m²] [kPa]
• Ship-lap edge, “L” profile • Smooth surface • Board’s dimensions: 1250 / 600 [mm]
• Ship-lap edge, “L” profile • Smooth surface • Board’s dimensions: 1250 / 600 [mm]
• Ship-lap edge, “L” profile • Smooth surface • Board’s dimensions: 1250 / 600 [mm]
04
RECOMMENDED USES
FLOORS:
• Heavy loaded floors
(warehouses and industrial buildings)
• Skating rings
BELOW GRADE CONSTRUCTIONS:
• Foundation slabs
• Swimming pools FIBRANxps 400-L thermal insulation
• Antiseismic insulation under a foundation slab
ROOFS:
• Inverted flat roofs
• Green roofs with heavy load
• Flat roof parking
FLOORS: A roof garden on top of an inverted roof of an FIBRANxps 400-L under a swimming pool
• Heavy loaded floors underground garage foundation slab
• Cold rooms
BELOW GRADE CONSTRUCTIONS: FIBRANxps 600-L
• Foundation slabs for the thermal
insulation of cold
rooms
ROOFS:
• Parking on inverted flat roofs
FLOORS:
• Extra loaded floors of warehouses and
industrial buildings
• Cold rooms
BELOW GRADE CONSTRUCTIONS:
• Foundation slabs
FROST PROTECTION:
• Bridges, roads and railways
ROOFS:
• Parking on inverted flat roofs
FLOORS:
• Extra loaded floors
BELOW GRADE CONSTRUCTIONS:
• Foundation slabs
FROST PROTECTION:
• Bridges, roads and railways XPS thermal insulation under a railway
• Airport hangers and runways
05
XPS - EN 13164 - T1 - CS(10\Y)* - DS(TH) - DLT(2)5 - WL(T )0,7 - WD(V)3 - FT2
thermal insultation for heavy loads
• Straight edge, “I” profile • Smooth surface • Board’s dimensions: 1250 x 600 [mm]
Quantity
FIBRANxpe Thickness
[mm]
Width
[mm]
Lenght
[m]
in one packet
[m2]
sponge foil
In floor application, one layer of FIBRANxpe foil beneath or on top of thermal insulation can reduce
the apparent level of impact noise by at least 18 dB
• Tongue and grooved edge, • Smooth surface • Board’s dimensions: 2500 x 600 [mm]
“D” profile
FIBRANfix UFS
10-150 6-9
fasteners
4/300-700
fasteners for thermal insulation
SP 140 100-120 6-9
06
FIBRANxps 300-I
RECOMMENDED USES
thermal insulation for
underfloor heating
ROOFS:
• Pitched roofs – combined insulation
FLOORS:
• Floors between storeys
• Basement floors
• Attic floors under pitched roofs
• Underfloor heating
ROOFS:
• Pitched roofs
• Visible ceilings
• Ceilings for warehouses, sports structures
and agricultural buildings
• Swimming pools
WALLS:
• Overcladded and cavity walls
SP - anchor for the use of thermal PP - ETICS façade anchor PSK - anchor with metal core SS - hidden anchor for visible
insulation as a blind formwork thermal insulation
07
XPS - EN 13164 - T3 - CS(10\Y)* - TR400 - DS(TH) - DLT(2)5 - WL(T )1,5 - FT2
• Ship-lap edge, • Rough surface with • Board’s dimensions: 2500 x 600 [mm]
“L” profile channels • Tongue and grooved, “D” profile
upon request
Possibilities:
• Thickness from 30 to 180 [mm]
• Length from 1000 to 3100 [mm]
• Width from 500 to 1250 [mm]
• Cutting boards: thickness from 9 to 40 [mm]
• Boards with different grooves
• * Boards with higher compressive strength
08
High tensile strength, water-repellent
thermal insulation produced with a rough
surface for good adhesion to plasters, con-
crete, glue, and other materials
ROOFS:
• Circumferential low walls of flat roofs
• Eaves of pitched roofs An Etics plinth façade with FIBRANxps ETICS
WALLS:
• Façade plinths
• «ETICS» - rendered façades
• Blind insulated formwork
• Internal or sandwich wall insulation
• Thermal bridges (balconies, windows and
door-jambs, concrete columns and tie-beams)
• Rendered internal walls next to cold rooms
Thermal insulation of thermal bridges (antiseismic An ETICS façade with FIBRANxps ETICS
tie-beams) with FIBRANxps ETICS
WALLS:
• Sandwich panels
• Thermal bridges (balconies, window and
door-jambs, concrete columns and tie-
beams)
• Internal walls next to cold rooms
• Ιn combination with gypsum boards
INDUSTRIAL USES:
• Material to cut various profiles for civil
engineering and industrial applications FIBRANxps FABRIC internal thermal insulation
• Window and door frame filling in combination with gypsum boards
• Filling for door leaves (PVC doors)
• Containers/vehicles
0130 FAÇADE
FIBRAN S.A.
Production of insulation materials
info@fibran.com
www.fibran.com