Professional Documents
Culture Documents
RICi-155GE
Gigabit Ethernet over STM-1/OC-3c NTU
Ethernet LANs over up RICi-155GE is a state-of-the-art network Typical applications include IP DSLAM
termination unit (NTU) that bridges backhauling (Figure 1), enterprise
to two STM-1/OC-3c between Gigabit Ethernet networks and connectivity (Figure 2), and
STM-1/OC-3c networks, providing simple, high-bandwidth private line services.
links efficient, and cost-effective Gigabit RICi-155GE is equipped with two
Ethernet connectivity over SDH/SONET STM-1/OC-3c ports with SFP-based optical
networks. The device offers a migration interfaces, offering either 300 Mbps with
path for connecting future-ready IP link bonding using VCAT (G.707/Y.1322)
devices to existing SDH/SONET networks and LCAS (G.7042), or 1+1 link protection
at up to 300 Mbps access rates. mechanism (unidirectional MSP/APS) to
RICi-155GE complies with RAD’s unique increase service uptime. The unit has two
set of EtherAccessTM features. This feature Gigabit Ethernet ports that support Gigabit
set provides carrier-grade Ethernet Ethernet link redundancy based on link
services and backhaul applications over aggregation protocol IEEE 802.3ad. The
low and high-speed SDH/SONET and PDH Gigabit Ethernet ports can be ordered with
circuits, from fractional and full E1/T1 or SFP-based optical interfaces or
E3/T3 over STM-1/OC-3c or STM-4/OC-12 10/100/1000BaseT interfaces.
to Gigabit Ethernet.
FLEXIBLE TRAFFIC MAPPING The preceding capabilities allow service SDH/SONET alarms can optionally
providers to offer different services and propagate and cause the Gigabit Ethernet
The incoming customer traffic is mapped
traffic types over the same link. link to shut down. The Gigabit Ethernet
to the Ethernet flows (EVCs) using the
following per-port criteria: alarms can also be propagated over the
SDH/SONET TIMING OPTIONS
• Port-based (All-in-one bundling) SDH/SONET link.
The user can define the following
• User port + CE-VID SDH/SONET clock sources: ETHERNET OAM
• User port + CE-VLAN priority. • Internal RICi-155GE provides two types of Ethernet
Each Ethernet flow can either have a • Recovered from STM-1/OC-3c OAM:
single service assigned to it or up to eight interface. • OAM Connectivity Fault Management
services that are differentiated by the
(CFM) based on IEEE 802.1ag and ITU T
CE-VLAN P-bits (EVC.CoS). SDH/SONET LINK REDUNDANCY Y.1731 enables Ethernet service
The unit supports a 1+1 link protection providers to monitor their services
ENCAPSULATION proactively, measure end-to-end
mechanism (APS), according to the
Traffic is encapsulated with: performance, and guarantee that
ITU-T G.841 requirements (unidirectional
customers receive the contracted SLA.
• Generic Framing Procedure (ITU-T MSP). Additional protection is provided by
• Single segment (link) OAM according to
G.7041, ANSI T1-105.02), framed the VCAT and LCAS protocols. IEEE 802.3ah for remote management
mode and fault indication.
• Link Access Procedure for SDH/SONET GIGABIT ETHERNET LINK REDUNDANCY
(LAPS) protocol following draft To allow reliable and uninterrupted MANAGEMENT
recommendation ITU-T X.86. service, the Gigabit Ethernet ports can be The unit can be managed with the
set to work in 1:1 or 1+1 automatic following ports and applications:
QUALITY OF SERVICE – QoS protection switching mode, according to
link aggregation protocol (IEEE 802.3ad). • Out-of-band management via Fast
Different service types require different
Ethernet or RS-232 port
levels of QoS to be provided end-to-end.
QoS can be defined per subscriber as well MEF COMPLIANCE • Remote inband management via
as per service. QoS has two aspects: rate RICi-155GE is certified by the Metro SDH/SONET or Gigabit Ethernet port.
limitation and traffic prioritization. Ethernet Forum (MEF) for the following Remote management is performed
services: using Telnet, Web browser, or an
Two policing mechanisms (upstream and SNMP-based management system.
downstream) are applied per service. The MEF 9: EPL, EVPL
policing mechanisms operate according to MEF 14: EPL, EVPL SECURITY
the dual leaky bucket mechanism
RICi-155GE supports the following security
(CIR+CBS, EIR + EBS: two rates, three FAULT PROPAGATION
protocols, to provide a high level of
colors). The unit features a user-configurable client-server communication security:
For prioritizing user traffic, RICi-155GE bidirectional fault propagation mechanism
• SNMPv3
features up to four separate queues. that notifies local and remote equipment
of faulty conditions.This enables routers • RADIUS authentication
The queues handle traffic with different
and switches on both ends of the link to • SSL for Web-based managemen
service demands, such as real-time traffic,
premium data, or best-effort data. reroute traffic. • SSH for Secure Shell communication.
product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.
414-100-06/09 Specifications are subject to change without prior notice. © 1988–2009 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the
CBL-DB9F-DB9M-STR
Ordering 2XSFP1 Dual SFP-1 transceivers Control port cable
RICi-155GE/*/%/&/S 2XSFP2 Dual SFP-2 transceivers
OPTIONAL ACCESSORIES
2XSFP2D Dual SFP-2D transceivers
Legend
NULL Two empty SFP slots RICi-155GE-PS/AC
* Power supply: Note: 100-240 VAC power supply module
AC 100 to 240 VAC • If a single SFP is ordered, the second slot is
48 –48 VDC empty. RICi-155GE-PS/48
ACR Dual 100 to 240 VAC • It is strongly recommended to order this device -48 VDC power supply module
48R Dual –48 VDC with original RAD SFPs installed. This will ensure
that prior to shipping, RAD has performed RM-34
% Gigabit Ethernet port interface: Hardware kit for mounting one regular
comprehensive functional quality tests on the
SFP5 Single SFP-5 transceiver: RICi-155GE unit in a 19-inch rack
entire assembled unit, including the SFP devices.
Gigabit Ethernet, 850 nm,
RAD cannot guarantee full compliance to product (if non-NEBS option is ordered)
multimode, VCSEL, 0.55 km
specifications for units using non-RAD SFPs.
(0.3 mi) RM-34-23
SFP6 Single SFP-6 transceiver: S NEBS-3 compliancy
Hardware kit for mounting one
Gigabit Ethernet, 1310 nm, (Default= Unit supplied is 19-inch, not NEBS-compliant RICi-155GE unit in a
single mode, laser, 10.0 km NEBS-3 compliant): 23-inch rack (if NEBS option is ordered)
(6.2 mi) N3 NEBS-3 compliant
SFP6D Single SFP-6D transceiver: WM-34
Gigabit Ethernet, DDM, Hardware kit for mounting one regular
internal calibration, SUPPLIED ACCESSORIES
RICi-155GE unit on a wall (if the non-NEBS
1310 nm, single mode, laser, AC power cord option is ordered)
10.0 km (6.2 mi) DC power connection kit (if DC power
2XSFP5 Dual SFP-5 transceivers supply is ordered)
2XSFP6D Dual SFP-6D transceivers
2XUTP Dual UTP ports
Product Comparison Table
NULL Two empty SFP slots
& SDH/SONET port interface:
Feature RICi-155GE RIC-155GE
SFP1 Single SFP-1 transceiver:
Fast Ethernet/STM-1, (Ver. 2.0) (Ver. 2.0)
1310 nm, multimode, LED, Frame Size (Bytes) 64–9600 64–1664
2 km (1.2 mi)
Ethernet Flows Yes No
SFP2 Single SFP-2 transceiver:
Fast Ethernet/STM-1, QoS 802.1p 802.1p
1310 nm, single mode, laser, Port-based
15 km (9.3 mi) MEF Certification MEF 9, MEF 14:EPL, EVPL No
SFP2D Single SFP-2D transceiver: Number of Queues 4 (strict) 4 (strict)
Fast Ethernet/STM-1, DDM,
Encapsulation GFP (G.7041), Packet-over-SDH/SONET (POS)
internal calibration,
1310 nm, single mode, laser, LAPS (X.86)
15 km (9.3 mi) Traffic Mapping Port-based (All-in-one bundling) N/A
User port + CE-VID
User port + CE-VLAN priority
SDH/SONET APS 1+1 No
Redundancy
Gigabit Ethernet Yes No
Redundancy
Hot-Swappable Power Yes Yes
Supplies