Caùc Leänh Vaø Caùc Dòch Vuï Cuûa Ñaøi Neax
Caùc Leänh Vaø Caùc Dòch Vuï Cuûa Ñaøi Neax
Dd_no for OGT & OGT loop back test : local call :820060
Dd_no for ICT loop back test : intraoffice call : 520060
MFC TEST
Swsh>view rlst data
Swsh>view rlst data id_fact=term_user_busy rtt=0
Swsh>view rt rn=vnhi dtl
Swsh>mod rlst id_fact=term_user_busy rtt=0 id_mfc=b5 aud_prvd=no
Swsh>view rlst data id_fact=term_user_busy
Swsh>view rt rn=vnho dtl
Swsh>view rt rn=vnhi dtl
Swsh>mod rlst id_fact=term_user_busy rtt=0 id_mfc=b2 aud_prvd=no
Swsh>reg smon n=520013
Swsh>view smon
Swsh>view rlst data id_fact=blocked
Swsh>blk subl n=520014
Swsh>mod rlst id_fact=blocked rtt=0 id_mfc=b5 aud_prvd=no
CREATE ROUTING
Cre rtng idx_rut=lclc rut=1test#1
View rtng idx_rut=lclc
Mod rtng idx_rut=lclc rut_01=2test#1
View rtng idx_rut=lclc
(before create rtng must create sndd idx_edit=1)
CREATE TRANSLATOR
Cre trn trid=subl n=92 ac=lcl d=4-4 dst=lcl type_chrg=ncg… idx_rut=lclc
Act trn area_ofd=new
CREATE TRUNK
Cre trk et=000011* cn=1test0001 cic=0001
Cre trk et=000211* cn=2test0001 cic=0001
Ins trk rn=1test
Cre lgn lgn=1 kind_adjct=sp sig_atrb=itu_64k nwind_main=2
Cre lgn lgn=1 kind_adjct=sp sig_atrb=itu_64k nwind_main=2
View lgn kind=data
SIGNALLING LINK
Cre slk slk_no=0001 lgn=001 slk_code=0 csc_no=cp00_n7l0000 ch=00001116
Cre slk slk_no=0002 lgn=002 slk_code=0 csc_no=cp00_n7l0001 ch=00021116
(cp00_n7lxxxx : 04 digits : first 03 digit for URTC number, last digit for csc number)
(slk_code : same value in both side of signalling)
View slk kind=data
NO7 ROUTE
Swsh>cre n7rt node=node1 nwind=2 pc=00010 lgn_adjct=000 lgn_main=000
Swsh>cre n7rt node=node2 nwind=2 pc=00020 lgn_adjct=001 lgn_main=001
Swsh>reg n7lb slk slk_no=0 idx=0
Swsh>reg n7lb slk slk_no=1 idx=1
Swsh>view n7lb slk
NO7 LOOP BACK POINT CODE
Reg n7lb pc idx=00 nwind=2 dpc_fwd=00010 dpc_bwd=00011 opc_bwd=00020
Reg n7lb pc idx=01 nwind=2 dpc_fwd=00020 dpc_bwd=00021 opc_bwd=00010
View n7lb pc
(dpc : destination point code opc : origination point code )
SIGNALLING LEVEL
Cre n7l2a slk_opt=itu 64k slk_atrb=itu_64k
Cre n7l3a ptcl_opt=itu nwind=2
Slk_opt : signalling option
Ptcl_opt : protocol option
Level 2 and level 3 of No7 signalling for VN network
View n7l2a
View n7l3a