You are on page 1of 2

Cement Mill Test Report

Date of Issue: May 12, 2017


Plant: Exshaw AB
Product: Portland Cement Type I/II
Mill Test Report Number: MTR-I/II-2017-04
Manufactured: April 2017

ASTM C 150-16 and AASHTO M 85-16 Standard Requirements

CHEMICAL ANALYSIS PHYSICAL ANALYSIS

Item Spec limit Test Result Item Spec limit Test Result
Rapid Method, X-Ray (C 114) Air content of mortar (%) (C 185) 12 max 8
SiO2 (%) --- 19.9
Al2O3 (%) 6.0 max 4.7 Blaine Fineness (m2/kg) (C 204) 280 - 430 398
Fe2O3 (%) 6.0 max 3.2
CaO (%) --- 62.7 Passing 45 um (%) (C 430) --- 98.8
MgO (%) 6.0 max 4.4
SO3 (%) 3.0 max * 3.1 Autoclave expansion (%) (C 151) 0.80 max 0.11
Loss on ignition (%) 3.5 max 1.4
Insoluble residue (%) 1.5 max 0.09 Compressive strength (MPa, [PSI]) (C 109)
CO2 (%) --- 0.9
Limestone (%) 5.0 max 2.2 3 days 12.0 [1740] min 28.4 [4110]
CaCO3 in Limestone (%) 70 min 94 7 days 19.0 [2760] min 35.5 [5140]
Inorganic Process Addition 5.0 max 0 28 days (Reflects previous month's data) 46.5 [6740]
(Lafarge Cement Kiln Dust)
Time of setting (minutes)
Adjusted Potential Phase Composition (C 150) Vicat Initial (C 191) 45 - 375 103
C3S (%) --- 51
C2S (%) --- 19 Heat of Hydration (KJ/Kg, [cal/g]) (C 186)
C3A (%) 8 max 7 7 days (for information only)** --- 347 [83]
C4AF (%) --- 10
C3S+4.75*C3A (%) 100 max 84 Mortar Bar Expansion (%) (C 1038) ** 0.020 max 0.014 (4th Q)
ASTM C 150-15 and AASHTO M 85-15 Optional Chemical Requirements:
NaEq (%) 0.60 max 0.50
* May exceed 3.0% SO3 maximum based on our C 1038 results of <0.020% expansion at 14 days.
** Current Production run not available - most recent provided

We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements
ASTM C 150-16 & AASHTO M 85-16 STANDARD SPECIFICATIONS FOR TYPE I AND TYPE II CEMENT;
ASTM C 150-16 & AASHTO M 85-16 OPTIONAL CHEMICAL REQUIREMENTS FOR TYPES I & II LOW ALKALI CEMENT.

Certified By:

Western Canada BU - Exshaw Plant


P.O. Box 160, Highway 1A, Exshaw AB, T0L 2C0 _____________________________________
Phone: 403-673-3815 Joanne Leclerc - Quality Assurance Coordinator
Cement Mill Test Report
Date of Issue: May 12, 2017
Plant: Exshaw, AB
Product: Portland Cement Type I/II
Mill Test Report Number: MTR-I/II-2017-04
Manufactured: April 2017

Additional ASTM C 150-16 and AASHTO M 85-16 Standard data

Additional Data

Item Test Result


Limestone Inorganic Process Addition
Lafarge Cement Kiln Dust
Amount (%) 2.2 0
SiO2 (%) 0.7 n/a
Al2O3 (%) 0.6 n/a
Fe2O3 (%) 0.3 n/a
CaO (%) 51.3 n/a
SO3 (%) 0.2 n/a
CO2 (%) 41.5 n/a

Base Cement Phase Composition

Item Test Result


C3S (%) 52
C2S (%) 19
C3A (%) 7
C4AF (%) 10

We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements
ASTM C 150-16 & AASHTO M 85-16 STANDARD SPECIFICATIONS FOR TYPE I AND TYPE II CEMENT;
ASTM C 150-16 & AASHTO M 85-16 OPTIONAL CHEMICAL REQUIREMENTS FOR TYPES I & II LOW ALKALI CEMENT.

Note: Specifc Gravity for Portland Cements is 3.15

Certified By:

Western Canada BU - Exshaw Plant


P.O. Box 160, Highway 1A, Exshaw AB, T0L 2C0 _____________________________________
Phone: 403-673-3815 Joanne Leclerc - Quality Assurance Coordinator

You might also like