You are on page 1of 1

T1-G T1-F T1-E T1-D T1-C T1-B T1-A

30200

6950 4330 6700 2070 7250 2900


173.60
T1 _ CROWN LEVEL

11730
11730
UPPER ROOF
FFL 161.88 SSL 161.600
T1 _ UPPER ROOF LEVEL

6080
6080
ROOF
FFL 155.80 SSL 155.525
T1 _ ROOF LEVEL

4000
FFL 151.80 SSL 151.650
T1 _ LEVEL-43 (PENTHOUSE-02)

8000
PENTHOUSE

4000
FFL 147.80 SSL 147.650
T1 _ LEVEL-42 (PENTHOUSE-01)

4200
FFL 143.60 SSL 143.550
T1 _ LEVEL-41

FFL 140.20 SSL 140.150

3400
T1 _ LEVEL-40

FFL 136.80 SSL 136.750

3400
T1 _ LEVEL-39

FFL 133.40 SSL 133.350

3400
T1 _ LEVEL-38

FFL 130.00 SSL 129.950

3400
T1 _ LEVEL-37

FFL 126.60 SSL 126.550

3400
T1 _ LEVEL-36

FFL 123.20 SSL 123.150

3400
T1 _ LEVEL-35

FFL 119.80 SSL 119.750


3400
T1 _ LEVEL-34

FFL 116.40 SSL 116.350


3400

T1 _ LEVEL-33
62000
TIER 2

FFL 113.00 SSL 112.950


3400

T1 _ LEVEL-32

FFL 109.60 SSL 109.550


3400

T1 _ LEVEL-31

FFL 106.20 SSL 106.150


3400

T1 _ LEVEL-30

FFL 102.80 SSL 102.750


3400

T1 _ LEVEL-29

FFL 99.40 SSL 99.350


3400

T1 _ LEVEL-28

FFL 96.00 SSL 95.950


3400

T1 _ LEVEL-27

FFL 92.60 SSL 92.550


3400

T1 _ LEVEL-26

FFL 89.20 SSL 89.150


3400

T1 _ LEVEL-25

FFL 85.80 SSL 85.750


3400

T1 _ LEVEL-24 TO 41
5500
5500

FFL 80.30 SSL 80.300


T1 _ LEVEL-23 (MECHANICAL-01)
MECHANICAL FLOOR

FFL 76.90 SSL 76.850


3400

T1 _ LEVEL-22

FFL 73.50 SSL 73.450


3400

T1 _ LEVEL-21

FFL 70.10 SSL 70.050


3400

T1 _ LEVEL-20

FFL 66.70 SSL 66.650


3400

T1 _ LEVEL-19

FFL 63.30 SSL 63.250


3400

T1 _ LEVEL-18

FFL 59.90 SSL 59.850


3400

T1 _ LEVEL-17

FFL 56.50 SSL 56.450


3400

T1 _ LEVEL-16

FFL 53.10 SSL 53.050


3400

T1 _ LEVEL-15

FFL 49.70 SSL 49.650


3400

T1 _ LEVEL-14

FFL 46.30 SSL 46.250


3400

T1 _ LEVEL-13

FFL 42.90 SSL 42.850


3400
71400
TIER 1

T1 _ LEVEL-12

FFL 39.50 SSL 39.450


3400

T1 _ LEVEL-11

FFL 36.10 SSL 36.050


3400

T1 _ LEVEL-10

FFL 32.70 SSL 32.650


3400

T1 _ LEVEL-09

FFL 29.30 SSL 29.250


3400

T1 _ LEVEL-08

FFL 25.90 SSL 25.850


3400

T1 _ LEVEL-07

FFL 22.50 SSL 22.450


3400

T1 _ LEVEL-06

FFL 19.10 SSL 19.050


3400

T1 _ LEVEL-05

FFL 15.70 SSL 15.650


3400

T2_ LEVEL-04

FFL 12.30 SSL 12.250


3400

T1 _ LEVEL-03

FFL SSL 8.850


3400

T18.90
_ LEVEL-02 TO 22 / T2 _L02 TO
L03
3900
3900

FFL 5.00 SSL 4.950


PODIUM

LEVEL-01
GF

FFL 1.20 SSL 1.050


LEVEL-1.2M
1200 3800
1200 3800

FFL 0.00 SSL -0.150


GROUND FLOOR

FFL -5.00 SSL -5.000


BASEMENT-01

FFL -8.80 SSL -8.800


BASEMENT-02
Rev.

Job No.
1 : 300

71380
CLIENT
SITE.

Scale @ A1
Date
KEYPLAN

P.O. Box 282478


CONSULTANT

R0 10/05/2018
PROJECT TITLE

DRAWING TITLE

C
GENERAL NOTES

TOWER 1

Date
SPECIFICATION.
B

Marina Plaza, Level 8


DESIGN ARCHITECT
DESIGN MANAGEMENT

Drawing No.
Description

01/31/2018
SHEET ISSUE DATE: 01/31/18

FS-105
ARE FULLY COORDINATED.
ARE FULLY COORDINATED.
CONSULTANTS APPROVAL.
D

Tower 2 - 2B+G+4 Storey

PERKINS EASTMAN
Tower 1 - 2B+G+43 Storey

A
Sheikh Zayed Road, Dubai, United Arab Emirates
Gold and Diamond Park Building 5, Office 125-126

Drawn
T. +971.4.343.3632 | F. +971.4.343.3604
DIMENSIONS ARE TO BE FOLLOWED.

Dubai Marina, PO Box 212763 | Dubai, UAE


METERS UNLESS NOTED OTHERWISE.

MEINHARDT FACADE TECHNOLOGY


1. THIS DRAWING IS COPYRIGHT PROTECTED.

DCH PLOT NUMBER : A017

CALLOUTS ELEVATION B
Tower on DCH Island District

-
Q

Checked
4. ANY DISCREPANCIES BETWEEN ARCHITECTURAL,
STRUCTURAL & SERVICES SHALL BE BROUGHT TO

OTHER RELEVANT DRAWINGS, TOGETHER WITH THE

THE LAGOONS PHASE ONE LLC


3. DO NOT SCALE FROM THIS DRAWING. ONLY WRITTEN

100% TENDER DOCUMENTS SUBMISSION


A COMPLETE SET OF DETAILED SHOP DRAWINGS FOR
ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK AT
2. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN

5. ALL DIMENSIONS AND LEVELS ARE TO BE CONFIRMED AND

-
ANY DISCREPANCIES OF ERRORS, SHALL BE INFORMED TO

Emaar Plot A017 Icon Bay Residential


9. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH
8. THESE DRAWINGS ARE TO BE READ IN CONJUNCTION WITH

Rev.
THE SITE ENGINEER PRIOR TO COMMENCEMENT OF WORK.

0
6. ALL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ALL
N

7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PRODUCING

F: +971 4 323 7592

Approved
T: +971 4 380 9422
FACADE ACCESS DRAWINGS. CONTRACTOR TO ENSURE THESE
FACADE LIGHTING DRAWINGS. CONTRACTOR TO ENSURE THESE

You might also like