You are on page 1of 3

Site Visit required:91008;Climb:No;Specific Tools required:No;Pre-Ordering of

Spares required:No;

#CHARIOT#FMT#ROT008 - TMA issue on S3 L800

1. MBNL Site ID - ROT008


2. Fault Summary - TMA S3 L800 not scannable
3. Fault Priority - P4
4. Impact - N/A
5. FYI Ticket Reference - N/A
6. Diagnostics to date

Display Antenna Port Dynamic Information


----------------------------------------
Cabinet No. Subrack No. Slot No. Antenna Port No. ALD Actual Power Switch ALD
Current Value(mA)

0 60 0 R0A ON 136
0 60 0 R0B OFF NULL
0 60 0 R0C OFF NULL
0 60 0 R0D OFF NULL
0 61 0 R0A ON 136
0 61 0 R0B ON 111
0 61 0 R0C OFF NULL
0 61 0 R0D OFF NULL
0 80 0 R0A OFF NULL
0 80 0 R0B OFF NULL
0 80 0 R0C OFF NULL
0 80 0 R0D OFF NULL
0 81 0 R0A OFF NULL
0 81 0 R0B OFF NULL
0 81 0 R0C OFF NULL
0 81 0 R0D OFF NULL
0 82 0 R0A OFF NULL
0 82 0 R0B OFF NULL
0 82 0 R0C OFF NULL
0 82 0 R0D OFF NULL
(Number of results = 20)

--- END

Report Type = Scan ALD


Status = Success
Session ID = 66445

Result
------
Control Port Cabinet No. Control Port Subrack No. Control Port Slot No. Control
Port No. Result ALD Device Type Vendor Code Serial No. Protocol
Version Configure Status Number of Subunits Failure Cause

0 60 0 R0A
SUCCESS SINGLE_RET AN 0000CN10151808054 AISG2.0
CONFIGURED 1 NULL
0 60 0 R0A
SUCCESS STMA AN 0000a004K2065848a AISG2.0
CONFIGURED 2 NULL
0 61 0 R0A
SUCCESS SINGLE_RET AN 0000CN10151808066 AISG2.0
CONFIGURED 1 NULL
0 61 0 R0A
SUCCESS STMA AN 0000a004K1998499a AISG2.0
CONFIGURED 2 NULL
0 80 0 NULL
FAILURE NULL NULL NULL NULL NULL
NULL Power switches of all ports are turned off.
0 81 0 NULL
FAILURE NULL NULL NULL NULL NULL
NULL Power switches of all ports are turned off.
0 82 0 NULL
FAILURE NULL NULL NULL NULL NULL
NULL Power switches of all ports are turned off.
(Number of results = 7)

--- END

List TMA Configuration


----------------------
Device No. Device Name TMA Type Control Port Cabinet No. Control Port Subrack
No. Control Port Slot No. Number of TMA Subunits Vendor Code Serial No.

50 TMA_L8_S1_A Normal TMA 0 60


0 1 AN 0000a004K2065848a
52 TMA_L8_S2_A Normal TMA 0 61
0 1 AN 0000a004K1998499a
54 TMA_L8_S3_A Normal TMA 0 61
0 1 AN 0000a004K2088025a
(Number of results = 3)

--- END

Display TMA Dynamic Information


-------------------------------
Device No. Device Name Actual Vendor Code Actual Device Serial No. Actual
Number of Subunits Control Port Cabinet No. Control Port Subrack No. Control
Port Slot No. Control Port No.

50 TMA_L8_S1_A AN 0000a004K2065848a 2
0 60 0 R0A
52 TMA_L8_S2_A AN 0000a004K1998499a 2
0 61 0 R0A
54 TMA_L8_S3_A NULL NULL NULL
0 61 0 NULL
(Number of results = 3)

--- END

7. Activity requested
FE need to check the AISG cable between RRU and antenna. FE need to bring a spare
TMA and replaced if is case.

8. Hardware details - N/A


9. Firmware/Software details - N/A
10. Link IDs - N/A

Point of Contact (Engineer dealing and contact number): e-mail:


chariotnocfo@ms.huawei.com Tel: +442038599216

Do not close WFM without Huawei NOC confirmation


Once at site please call the Huawei NOC on +442038599216