Requirements of the PROP A (Customer If this message is not present, the transmission
Controller Throttle Interface) assumes that the engine has a standard throttle
interface. In the TH55 application, the engine must
Some of the engines that are used with this be configured to utilize a CAN-based engine throttle
transmission do not arbitrate properly between a with the PROP A message. This function is required
simultaneous J1939 TSC1 speed command from a for speed/torque limiting in 1F converter drive. The
J1939 throttle and a transmission speed or torque PROP A message commands the desired speed and
limit command. the transmission commands the desired torque limit
and controls the engine throttle.
In order to support these configurations, a proprietary
message is provided. This message will permit the Operation with a J1939 TSC1 throttle that sends
J1939 throttle controller to send a speed request to commands directly to the engine is not supported.
the transmission. As a result, using this throttle may lead to damage
to the transmission.
If this message is present and limiting is required,
the transmission will transmit a simultaneous
remote throttle command to the engine. Also, the
transmission will transmit a TSC1 speed and torque
limit command to the engine. The limit command
overrides the remote throttle command in order to
provide the desired engine speed and/or torque.
16