You are on page 1of 6

[root@CS0-AYA ~]# /nas/bin/nas_checkup

Check Version: 7.1.76.4


Check Command: /nas/bin/nas_checkup
Check Log : /nas/log/checkup-run.180323-152750.log

-------------------------------------Checks-------------------------------------
Control Station: Checking statistics groups database....................... Pass
Control Station: Checking if file system usage is under limit.............. Pass
Control Station: Checking if NAS Storage API is installed correctly........ Pass
Control Station: Checking if NAS Storage APIs match........................ Pass
Control Station: Checking if NBS clients are started....................... Pass
Control Station: Checking if NBS configuration exists...................... Pass
Control Station: Checking if NBS devices are accessible.................... Pass
Control Station: Checking if NBS service is started........................ Pass
Control Station: Checking if PXE service is stopped........................ Pass
Control Station: Checking if standby is up................................. Pass
Control Station: Checking integrity of NASDB............................... Pass
Control Station: Checking if primary is active............................. Pass
Control Station: Checking all callhome files delivered..................... Pass
Control Station: Checking resolv conf...................................... Pass
Control Station: Checking if NAS partitions are mounted.................... Pass
Control Station: Checking ipmi connection.................................. Pass
Control Station: Checking nas site eventlog configuration.................. Pass
Control Station: Checking nas sys mcd configuration........................ Pass
Control Station: Checking nas sys eventlog configuration................... Pass
Control Station: Checking logical volume status............................ Pass
Control Station: Checking valid nasdb backup files......................... Pass
Control Station: Checking root disk reserved region........................ Pass
Control Station: Checking if RDF configuration is valid.................... N/A
Control Station: Checking if fstab contains duplicate entries.............. Pass
Control Station: Checking if sufficient swap memory available.............. Pass
Control Station: Checking for IP and subnet configuration.................. Pass
Control Station: Checking auto transfer status............................. Warn
Control Station: Checking for invalid entries in etc hosts................. Pass
Control Station: Checking for correct filesystem mount options............. Fail
Control Station: Checking the hard drive in the control station............ Pass
Control Station: Checking if Symapi data is present........................ Pass
Control Station: Checking if Symapi is synced with Storage System.......... Pass
Blades : Checking boot files....................................... Pass
Blades : Checking if primary is active............................. Fail
Blades : Checking if root filesystem is too large.................. ?
Blades : Checking if root filesystem has enough free space......... ?
Blades : Checking Server IfConfig.................................. Pass
Blades : Checking network connectivity............................. Pass
Blades : Checking status........................................... Pass
Blades : Checking dart release compatibility....................... Pass
Blades : Checking dart version compatibility....................... Pass
Blades : Checking server name...................................... Pass
Blades : Checking unique id........................................ Pass
Blades : Checking CIFS file server configuration................... Warn
Blades : Checking domain controller connectivity and configuration. Pass
Blades : Checking DNS connectivity and configuration............... Pass
Blades : Checking connectivity to WINS servers..................... Pass
Blades : Checking I18N mode and unicode translation tables......... Pass
Blades : Checking connectivity to NTP servers...................... Warn
Blades : Checking connectivity to NIS servers...................... Pass
Blades : Checking virus checker server configuration............... Pass
Blades : Checking if workpart is OK................................ Pass
Blades : Checking if free full dump is available................... Pass
Blades : Checking if each primary Blade has standby................ Info
Blades : Checking if Blade parameters use EMC default values....... Pass
Blades : Checking VDM root filesystem space usage.................. N/A
Blades : Checking if file system usage is under limit.............. Warn
Blades : Checking slic signature................................... Pass
Storage System : Checking disk emulation type.............................. Pass
Storage System : Checking disk high availability access.................... Pass
Storage System : Checking disks read cache enabled......................... Pass
Storage System : Checking disks and storage processors write cache enabled. Pass
Storage System : Checking if FLARE is committed............................ Pass
Storage System : Checking if FLARE is supported............................ Pass
Storage System : Checking array model...................................... Pass
Storage System : Checking if microcode is supported........................ N/A
Storage System : Checking no disks or storage processors are failed over... Pass
Storage System : Checking that no disks or storage processors are faulted.. Pass
Storage System : Checking that no hot spares are in use.................... Pass
Storage System : Checking that no hot spares are rebuilding................ Pass
Storage System : Checking minimum control lun size......................... Pass
Storage System : Checking maximum control lun size......................... N/A
Storage System : Checking maximum lun address limit........................ Pass
Storage System : Checking system lun configuration......................... Pass
Storage System : Checking if storage processors are read cache enabled..... Pass
Storage System : Checking if auto assign are disabled for all luns......... N/A
Storage System : Checking if auto trespass are disabled for all luns....... N/A
Storage System : Checking storage processor connectivity................... Pass
Storage System : Checking control lun ownership............................ N/A
Storage System : Checking if Fibre Channel zone checker is set up.......... N/A
Storage System : Checking if Fibre Channel zoning is OK.................... N/A
Storage System : Checking if proxy arp is setup............................ Pass
Storage System : Checking if Product Serial Number is Correct.............. Pass
Storage System : Checking SPA SPB communication............................ Pass
Storage System : Checking if secure communications is enabled.............. Pass
Storage System : Checking if backend has mixed disk types.................. Pass
Storage System : Checking for file and block enabler....................... Pass
Storage System : Checking if nas storage command generates discrepancies... Pass
Storage System : Checking if Repset and CG configuration are consistent.... Pass
Storage System : Checking block operating environment...................... Pass
Storage System : Checking thin pool usage.................................. N/A
Storage System : Checking for domain and federations health on VNX......... Pass
--------------------------------------------------------------------------------

One or more errors have occurred. Follow the instructions provided to correct
the problem and try again.

-----------------------------------Information----------------------------------
Control Station: Check if standby is up
Information HC_CS_27389984778: The standby Control Station is
currently powered on. It will be powered off during upgrade, and then
later restarted and upgraded.

Blades : Check if each primary Blade has standby


Information HC_DM_27390050395: The following primary Blade(s) server_2
do(es) not use automatic failover policy. It is recommended that each
primary Blade have a standby configured for it with automatic failover
policy for high availability.

--------------------------------------------------------------------------------

------------------------------------Warnings------------------------------------
Control Station: Check auto transfer status
Warning HC_CS_18800050420: Cannot establish connection to FTP server
sftphost sftp.emc.com
Action : Command "/nas/tools/automaticcollection -verifyftp" failed to
connect to FTP connection. Check the configuration in
/nas/site/automaticcollection.cfg file. For more information, search
the Knowledgebase on Powerlink as follows:
1. Log in to http://powerlink.emc.com and go to Support >
Knowledgebase Search> Support Solutions Search.
2. Use ID emc221733 to search.

Blades : Check CIFS file server configuration


Warning HC_DM_18800115743:
* server_2: The CIFS server 'AYACIFS' has not joined its domain. The
CIFS clients will not be able to access the shares of this server
using a domain user.
Action : Join the server in the domain using the server_cifs -
Join command.

Blades : Check CIFS file server configuration


Warning HC_DM_18800115743:
* server_2: The DNS server is not up-to-date. The IP address
10.158.214.3 of the CIFS server 'ayacifs.entelsn.local' is not
registered in DNS. Depending on the configured update mode
(parameter dns.updateMode), the issue may concern a manual update
that has not occurred on the DNS server or a Kerberos problem.
Action : If the DNS update mode is manual (dns.updateMode=0), update
the IP address of the CIFS server in the DNS manually. If not, try a
'server_cifs' command to figure out the problem with the FQDN. Take a
look also in the logs using server_log to figure out the Kerberos
issue, if any.

Blades : Check connectivity to NTP servers


Warning HC_DM_18800115743:
* server_2: Only one NTP server is configured. It is recommended to
define at least two different NTP servers for a high availability.
If the clock of the Data Mover is not correct, potential errors
during Kerberos authentication may happen (timeskew).
Action : Use the server_date command to define another NTP server on
the Data Mover. Read the man pages for details and examples.

Blades : Check if file system usage is under limit


Warning HC_DM_18800115861: The following mounted file systems are
full. At least 128K bytes of free space are required.
* ldap1LP
Action :

To resolve the problem, perform the following:


1. Remove unnecessary files from the specified file systems.
2. Run the "/nas/bin/server_df ALL" command to verify that the file
systems have met the minimum free space requirement.
3. If the minimum free space requirement is not met, extend the file
systems using the Unisphere or CLI and by referring to the
"Managing VNX Volumes and File Systems Manually" technical module
that can be found on http://powerlink.emc.com/

--------------------------------------------------------------------------------

-------------------------------------Errors-------------------------------------
Control Station: Check for correct filesystem mount options
Error HC_CS_14505082982: The following file systems were found to be
corrupted:
* prepago on server_2
Action :

Run "/nas/bin/server_mount ALL" manually to find the corrupted file


system. If the problem persists, escalate this issue through your
support organization if needed. Provide this output in the
escalation.

Blades : Check if primary is active


Error HC_DM_14505148434: Blade in slot 2 is failed over
Action :

Use command "/nas/bin/server_standby server_2 -restore mover" to


failback the server to slot 2.

Blades : Check if root filesystem is too large


Error HC_DM_14505148436: Output from command "/nas/bin/server_df
server_2" has no information on file system root_fs_3
Action :

1. See if a Blade has failed over to slot 3 by checking the


following:
- Did the "Blade: Check if primary is active" check fail?
- Does "/nas/bin/nas_server -l" list the Blades as faulted?
2. If this is the case, fail back the Blade with
"/nas/bin/server_standby <server_name> -restore mover" command.
3. Otherwise check with the /nas/bin/server_df command that the root
file system for Blade server_2 has the default name root_fs_3.
4. If it does not, rename the file system with the
/nas/bin/nas_fs command.

Blades : Check if root filesystem has enough free space


Error HC_DM_14505148440: Output from command "/nas/bin/server_df
server_2" has no information on file system root_fs_3
Action :

1. See if a Blade has failed over to slot 3 by checking the


following:
- Did the "Blade: Check if primary is active" check fail?
- Does "/nas/bin/nas_server -l" list the Blades as faulted?
2. If this is the case, fail back the Blade with
"/nas/bin/server_standby <server_name> -restore mover" command.
3. Otherwise check with the /nas/bin/server_df command that the root
file system for Blade server_2 has the default name root_fs_3.
4. If it does not, rename the file system with the
/nas/bin/nas_fs command.

--------------------------------------------------------------------------------

[root@CS0-AYA ~]#

[root@CS0-AYA /]# /nas/bin/nas_server -info -all


id = 1
name = server_2.faulted.server_3
acl = 0
type = standby
slot = 2
member_of =
standbyfor= server_2
status :
defined = out_of_service
actual = online, ready

id = 2
name = server_2
acl = 0
type = nas
slot = 3
member_of =
standby = server_2.faulted.server_3, policy=manual
status :
defined = enabled
actual = online, active
salida desde CLI de los comandos

/nas/bin/nas_checkup
/nas/bin/nas_server -info -all
/nas/bin/nas_storage -list
/nas/bin/nas_disk -list
nas_fsck -info -all

[root@CS0-AYA /]#

[root@CS0-AYA /]# /nas/bin/nas_storage -list


id acl name serial_number
1 0 CKM00122100990 CKM00122100990

[root@CS0-AYA /]#

[root@CS0-AYA /]# /nas/bin/nas_disk -list


id inuse sizeMB storageID-devID type name servers
1 y 11260 CKM00122100990-2007 CLSTD root_disk 1,2
2 y 11260 CKM00122100990-2008 CLSTD root_ldisk 1,2
3 y 2038 CKM00122100990-2009 CLSTD d3 1,2
4 y 2038 CKM00122100990-200A CLSTD d4 1,2
5 y 2044 CKM00122100990-200B CLSTD d5 1,2
6 y 65526 CKM00122100990-200C CLSTD d6 1,2
47 y 1096363 CKM00122100990-006E CLSAS d47 1,2
48 y 1096363 CKM00122100990-006F CLSAS d48 1,2
49 y 1096369 CKM00122100990-0064 CLSAS d49 1,2
50 y 1096363 CKM00122100990-0066 CLSAS d50 1,2
51 y 1096363 CKM00122100990-0068 CLSAS d51 1,2
52 y 1096363 CKM00122100990-006A CLSAS d52 1,2
53 y 1096363 CKM00122100990-006C CLSAS d53 1,2
54 y 1096369 CKM00122100990-0065 CLSAS d54 1,2
55 y 1096363 CKM00122100990-0067 CLSAS d55 1,2
56 y 1096363 CKM00122100990-0069 CLSAS d56 1,2
57 y 1096363 CKM00122100990-006B CLSAS d57 1,2
58 y 1096363 CKM00122100990-006D CLSAS d58 1,2
59 y 1096347 CKM00122100990-0070 CLSAS d59 1,2
60 y 1096363 CKM00122100990-0071 CLSAS d60 1,2
61 y 1095679 CKM00122100990-0072 CLSAS d61 1,2
62 y 1096363 CKM00122100990-0075 CLSAS d62 1,2
63 y 1096363 CKM00122100990-0074 CLSAS d63 1,2
64 y 1095679 CKM00122100990-0073 CLSAS d64 1,2

[root@CS0-AYA /]#