Professional Documents
Culture Documents
(OIPM-IND-0416)
Operating Instructions and Parts Manual
Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
S
4. All Federal, State, and local safety codes
Description should be followed.
Standard’s Drum Pumps are designed to 5. Verify that the motor voltage
transfer a variety of materials from 55 gallon corresponds to proper electrical supply.
drums and tanks. Standard Pump offers 6. Before plugging motor into power WARNING: The speed control
several different pumps, each designed supply, make sure the motor switch is in should not be used as the main ON/OFF
for specific applications. Before operating, the OFF position. For Air Motors ensure switch. Using the speed control switch in
please confirm that the pump’s materials of inlet valve is closed before attaching air this manner causes excessive wear to
construction are suitable for the application. line. the potentiometer and may result in
Unpacking 7. Before operation, confirm all pump premature failure. The use of the speed
connections are properly tightened. control switch does not cut power to the
Cartons should be handled with care to avoid motor and inadvertent activation could
damage from dropping, etc. After unpacking, 8. First pump clean water in order to
result in injury or death if the motor is
inspect carefully for any damage that may familiarize yourself with the pump’s
activated when not properly attended
have occurred during transit. Check for loose, operation, flow rate, discharge pressure
and secured. (Only applies to SP-280P
damaged or missing parts. and motor speed.
and SP-ENC Series)
9. Before starting the pump, confirm the
General Safety Information discharge hose is securely fastened to
The responsibility for safe assembly, the receiving vessel in order to prevent
installation, and operation ultimately rests splashing.
with the operator. Read and understand ALL 10. Never leave pump unattended during
safety precautions and operating instructions operation.
before operation. Careless pump operation WARNING: When pumping
11. Do not submerge the motor in any liquid. flammable or combustible products or
can result in serious injury.
12. When finished using the pump, flush operating in a hazardous duty
1. Before operating the pump, read and
the pump by pumping water or an environment, the SP-AL or SP-SS Series
understand these operating instructions. pump must be used in conjunction with
appropriate cleaning solution. Do not
2. The operator should wear suitable use flammable or combustible cleaning an explosion proof motor. Please contact
protective clothing including the solutions. the factory or an authorized distributor
following: face mask, safety shield or with any questions regarding this matter.
13. Never carry the motor by the power
goggles, gloves, apron, and safety
cord.
shoes.
14. Never store pump in a container or drum.
3. Before operating, verify the materials
Always rinse pump thoroughly and hang
being pumped are compatible with the
on wall bracket or ensure pump tube is
pump’s “wetted components.”
stored in an upright and vertical position.
SP-280 SP-ENC
7
8
9
2
10
5
*
*
4
*
*
*
11 3
12
13
Model HP Air Consumption Meter Wetted Components Immersion Length Hose Length Nozzle Material
9604 0.5 27 CFM (13 L/sec) @ 80 psi (5,51 bar) No SS316, PTFE, Carbon, UHMWPE, PTFE 39" (1000 mm) 6 ft. (1,83 meters) SS316
9605 0.75 28 CFM (13.2 L/sec) @ 90 psi (6,2 bar) No SS316, PTFE, Carbon, UHMWPE, PTFE 39" (1000 mm) 6 ft. (1,83 meters) SS316
9606 0.05 27 CFM (13 L/sec) @ 80 psi (5,51 bar) No SS316, PTFE, Carbon, UHMWPE, PTFE 47" (1200 mm) 6 ft. (1,83 meters) SS316
9607 0.75 28 CFM (13.2 L/sec @ 90 psi (6,2 bar) No SS316, PTFE, Carbon, UHMWPE, PTFE 47" (1200 mm) 6 ft. (1,83 meters) SS316
9464 0.75 28 CFM (13.2 L/sec @ 90 psi (6,2 bar) No Aluminum, Carbon, PTFE & SS316 39" (1000 mm) 6 ft. (1,83 meters) Aluminum
9465 0.75 28 CFM (13.2 L/sec @ 90 psi (6,2 bar) No Aluminum, Carbon, PTFE & SS316 47" (1200 mm) 6 ft. (1,83 meters) Aluminum
Operation
1. Once the pump is fully assembled and all connections are
4. While holding the drive shaft with pliers (factory suggests
securely fastened, insert the pump into the drum or tank.
using grip-locks to avoid scarring shaft) remove the impeller
2. Turn the motor switch to the “ON” position or open air inlet by turning counter clockwise (see Figure 4).
valve.
3. If your package contains a flow meter (Package numbers
9500-9503 or 9510-9513) please reference the factory
operating instructions which are located in your carton.
4. After use, clean the pump and store vertically.
Maintenance
Disassembly / Cleaning Procedures
1. In order to clean a majority of the residue from the pump
tube, immerse the pump into a 55 Gallon Drum of water.
Allow the pump to circulate the water for 3 minutes.
2. For a more thorough cleaning remove the motor from the
pump tube by loosening the hand wheel (see Figure 2).
Figure 4
Figure 2
Standard Pump Operating Instructions and Parts Manual (OIPM-IND-0416)
Figure 7
Inner Tube
Inner Tube
SP-PP, SP-PHT, SP-CPVC, SP-PVDF pumps should not be used to pump flammables.
10
11
12
SP-AL Series Spare Parts List
9
4 1038* 1
Spacer, Snap Ring, Bearing Can
5 V-Seal, PTFE 4000 1
1
6 Connection Flange, Aluminum 3723 1
2
3
7 Drive Shaft, SS316
27" (700 mm) 2027 1
4
39" (1000 mm) 2028 1
5
47" (1200 mm) 2029 1
6
60" (1500 mm) 2709 1
72" (1800 mm) 2710 1
8 Guide Sleeve, PTFE
7
27" (700 mm) 2031 1
39" (1000 mm) / 47" (1200 mm) 2032 1
60" (1500 mm) 2711 1
72" (1800 mm) 2712 1
9 Discharge Housing, Aluminum 3724 1
8
10 Seal, PTFE 2195* 1
11 Wing Nut, Aluminum 3709 1
14
12 Hose Barb, Aluminum
.75" (19 mm) 3708 1
1" (25 mm) 3707 1
13 Inner Tube, Aluminum
27" (700 mm) 3712 1
39" (1000 mm) 3714 1
47" (1200 mm) 3716 1
60" (1500 mm) 3718 1
72" (1800 mm) 3720 1
14 Seal, PTFE 730 1
15 Outer Tube, Aluminum
27" (700 mm) 3713 1
39" (1000 mm) 3715 1
47" (1200 mm) 3717 1
15
60" (1500 mm) 3719 1
72" (1800 mm) 3721 1
16 O-Ring, Viton (2 per set) 2707 1
17 Pump Housing, Aluminum 3725* 1
(Includes Carbon Bushing)
18 High Volume Impeller, PTFE 2706* 1
16 19 High Pressure Impeller, PTFE 4608HH 1
17
20 High Volume Pump Foot, Aluminum 3726 1
High Pressure Pump Foot, Aluminum 3726HH 1
18 19 21 Repair Kit (*Includes Items 3,4,10,17 & 18) 9057 1
20
When pumping flammables or combustible liquids, this pump must be used in conjunction with an explosion proof motor.
11
12
13
SP-6600 & 6700 Spare Parts List
10
Ref.
Description P/N Qty
Number
1 Handwheel, Polypropylene 1842 1
2 Snap Ring, Steel 1508 1
14
3 Pump Coupling, Nylon 1004 1
4 Bearing, Viton Shielded 1038-2 2
5 Bearing Spacer, SS316L 8838-4 1
6 V Seal, PTFE 4000 1
1 7 Connection Flange, AL 6061 6650 1
2 8 Drive Shaft, SS316L 1
3
27" (700mm) 6661
4 5
39" (1000mm) 6662
6
47" (1200mm) 6663
7
60" (1500mm) 6664
72" (1800mm) 6665
9 Guide Sleeve, PTFE 1
8 27", 39", 47" (700mm, 1000mm, 1200mm) 7659
60", 72" (1500mm), 1800mm) 7660
10 Discharge Housing, AL 6061 6651 1
11 Seal, PTFE 2195 1
9 12 Knurled nut, AL 6061 6656 1
13 Hose Barb, AL 6061 1
Hose Barb, 1", (19mm) 6657
Hose Barb, 3/4" (25mm) 6658
14 Inner Tube, AL 6061 1
27" (700mm) 6670
39" (1000mm) 6671
47" (1200mm) 6672
60" (1500mm) 6673
72" (1800mm) 6674
15 Outer Tube, AL 6061 1
27" (700mm) 6680
39" (1000mm) 6681
47" (1200mm) 6682
60" (1500mm) 6683
72" (1800mm) 6684
15
16 O-Ring Set, Viton 7655 2
17 Pump Housing, AL 6061 6685 1
18 Bushing, Carbon Graphite 7606 1
19 Rotor, Impeller, PTFE 1
High Volume Rotor (for 6600 Series) 7706
High Pressure Impeller (for 6700 Series) 4608HH
20 Pump Foot, AL 6061 1
16
High Volume (for 6600 Series) 6686
17 High Pressure (for 6700 Series) 6786
18 21 Repair Kit (Includes Items 3, 4, 5, 11, 17, 18) 6057 1
19
20
When pumping flammables or combustible liquids, this pump must be used in conjunction with an explosion proof motor.
Grounding Procedures Bonding and grounding are required when before starting). Always check with a safety
pumping flammable materials or in hazardous engineer when any question arises and
Transferring of duty environments. Failure to bond and periodically check safety procedures with a
flammables or use in ground properly can cause a discharge of safety engineer.
hazardous duty. Bonding is an electrical static electricity resulting in fire, injury or
connection between a primary metal vessel death. Follow NFPA 77 and 30 procedures
and a metal receiving vessel. See schematic. at all times. If in doubt, do not start pump!
Grounding is an electrical connection Be sure bonding and grounding wires are
between a metal vessel, pump, motor and a secure before starting operation. (Ground
constant ground; i.e. a metal rod driven into and bond wires must have less than one ohm
the earth. resistance for safe usage. Check continuity
Air Line
Exhaust Line
Bond Wire
Bond Wire
(Not Included)
No Splashing
Rod Rod
Designation: SP-280P
SP-280P-V
SP-ENC
SP-ENC-V
Item No:
SP-280P
SP-280P-V
SP-ENC
SP-ENC-V
Standard Pump Inc. | 1610 Satellite Blvd., Duluth, GA 30097 | ph. 770.307.1003 | fax 770.307.1009 | www.StandardPump.com
Standard Pump Operating Instructions and Parts Manual (OIPM-IND-0416)
EC Declaration of Conformity
Christopher Murphy
Director of Operations
Standard Pump Operating Instructions and Parts Manual (OIPM-IND-0416)
STANDARD PUMP
1610 Satellite Blvd . Suite D ., Duluth, Georgia 30097 USA
TOLL FREE 866–558–8611 • Phone 770–307–1003 • Fax 770–307–1009
info@standardpump .com