PROPOSED BUS STAND AT MINI

SMART CITY SIDHI (M.P.)


M.P.URBAN DEVELOPMENT CO.LTD., BHOPAL (M.P.)
M/S:- B.R.CIVIL CONCTRUCTION CO.
KEY NOTES:-
DWG.NO.:- MPUDCL/MSC/SIDHI/B.R.C./13 GRADE OF CONCRETE M-20
GRADE OF STEEL FE-415
DESIGN METHOD-L.S.M & STAAD PRO
AS PER IS 456:2000
COLUMN C-1 = 400MM X 600 MM
COLUMN C-2 = 600MM Ø
COLUMN C-3 = 300MM X 300 MM
COLUMN C-4 = 500MM Ø
COLUMN C-5 = 400MM X 400 MM
COLUMN C-6 = 300MM X 500 MM
LAP LENGTH = 32 Ø
SEISMIC ZONE-3
EXPANSION JOINT 20 MM SBC @2.5 M = 150 KN/M2,
3700 1250 2600 2600 2200 3000 2300 4480 3300 3300 3300 3300 3300 3300 3300 3300 3300 3300
SBC @2.0 M = 165.4 KN/M2, AS IN REPORT
C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3

3000
STAEMENT OF AREA
4300

C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 C-3 total plot area 26.0M X 62.0 M 1612.00 sqm.
C-3 C-3 C-5 C-3 C-3 C-5 C-3 C-5
ground floor area 1112.50 sqm.

3000
first floor area 1112.50 sqm.
C-3 C-6 C-3 C-3 C-3 C-3 C-3 second floor area 1112.50 sqm.
C-1 C-1 C-1 C-1 C-1 C-1 total floor area 3337.50 sqm.
EXPANSION JOINT 20 MM
6050

C-3 C-3 C-3

CLIENT'S SEAL & SIGN

2600
C-3 C-5 C-3 C-5 C-3
C-5 C-5 C-5

3500
6600

3500
C-3 C-5 C-3 C-5 C-3

C-5 C-5 C-5


4300

3300 3300 APPROVAL AGENCY SEAL & SIGN


C-4 C-2 C-2 C-2 C-2 C-2 C-2

3300
C-3 C-3 C-3 C-3 C-3
4950 3700 3700 5300
6600

C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4 C-4C-4 C-4

6600 6600 6600 6600 6580 6600 6600 6600 6620 6520 6600

all dimensions are in mm


SLAB FOR SHED 6.6 M WIDE COLUMN LAY OUT DETAILS scale NTS dwg.no.:- 13
date 16-12-19
dealt
appd. Ankesh

AATVIK CONSULTANCY
&
INFRASTRUCTURE
Add-95 Rachna nagar bhopal (M.P)
Email ID- aatvik.aatvik@gmail.com Foundation of Excellence
Mob No-9425463303

1. DO NOT SCALE THE DRAWING AND NOT COUNT THE BARS


2. ALL DIMENSIONS ARE IN MILI METER
3. S.B.C. OF SOIL = 150.0 KN/Sq.M
4. DEPTH OF FOUNDATION - 2.5 METER

this drg.is property of architects and is not to


be used or reproduced without their prior
written permission.

You might also like